Dear Editor,In a recent interventional case report,Allon et al )hydrated corneal stroma with cefuroxime to seal a small traumatic leaky corneal perforation that was unresponsive to prior soft bandage contact lens app...Dear Editor,In a recent interventional case report,Allon et al )hydrated corneal stroma with cefuroxime to seal a small traumatic leaky corneal perforation that was unresponsive to prior soft bandage contact lens application for 6d.展开更多
Sealing analysis of sealing system in reactor pressure vessels is relevant with multiple nonlinear coupled-field effects, so even large-scale commercial finite element software cannot finish the complicated analysis. ...Sealing analysis of sealing system in reactor pressure vessels is relevant with multiple nonlinear coupled-field effects, so even large-scale commercial finite element software cannot finish the complicated analysis. A finite element method of 3D transient coupled thermo-elastic-plastic contact sealing analysis for reactor pressure vessels is presented, in which the surface nonlinearity, material nonlinearity, transient heat transfer nonlinearity and multiple coupled effect are taken into account and the sealing equation is coupling solved in iterative procedure. At the same time, a computational analysis program is developed, which is applied in the sealing analysis of experimental reactor pressure vessel, and the numerical results are in good coincidence with the experimental resuits. This program is also successful in analyzing the practical problem in engineering.展开更多
As one of the main reasons causing leakage heat load in a refrigerator,mass and heat transfer through refrigerator door seal is of great importance to be studied.In this paper,a model is presented for numerical simula...As one of the main reasons causing leakage heat load in a refrigerator,mass and heat transfer through refrigerator door seal is of great importance to be studied.In this paper,a model is presented for numerical simulation of mass and heat transfer process through refrigerator door seal,and an experiment apparatus is designed and set up as well for comparison.A two-dimensional model and tracer gas method are used in simulation and experiment,respectively.It can be found that the relative deviations of air infiltration rate between the simulated results and experimental results were less than 1%,and the temperature difference errors at two special points of the door seal were less than 2.03℃.In conclusion,the simulated results are in good agreement with the experimental results.This paper initially sets up a model that can accurately simulate the heat and mass transfer through the refrigerator door seal,and the model can be used in refrigerator door seal optimization research in the follow-up study.展开更多
文摘Dear Editor,In a recent interventional case report,Allon et al )hydrated corneal stroma with cefuroxime to seal a small traumatic leaky corneal perforation that was unresponsive to prior soft bandage contact lens application for 6d.
文摘Sealing analysis of sealing system in reactor pressure vessels is relevant with multiple nonlinear coupled-field effects, so even large-scale commercial finite element software cannot finish the complicated analysis. A finite element method of 3D transient coupled thermo-elastic-plastic contact sealing analysis for reactor pressure vessels is presented, in which the surface nonlinearity, material nonlinearity, transient heat transfer nonlinearity and multiple coupled effect are taken into account and the sealing equation is coupling solved in iterative procedure. At the same time, a computational analysis program is developed, which is applied in the sealing analysis of experimental reactor pressure vessel, and the numerical results are in good coincidence with the experimental resuits. This program is also successful in analyzing the practical problem in engineering.
基金Supported by the National Science Fund for Distinguished Young Scholar(51525604)111 project B16038
文摘As one of the main reasons causing leakage heat load in a refrigerator,mass and heat transfer through refrigerator door seal is of great importance to be studied.In this paper,a model is presented for numerical simulation of mass and heat transfer process through refrigerator door seal,and an experiment apparatus is designed and set up as well for comparison.A two-dimensional model and tracer gas method are used in simulation and experiment,respectively.It can be found that the relative deviations of air infiltration rate between the simulated results and experimental results were less than 1%,and the temperature difference errors at two special points of the door seal were less than 2.03℃.In conclusion,the simulated results are in good agreement with the experimental results.This paper initially sets up a model that can accurately simulate the heat and mass transfer through the refrigerator door seal,and the model can be used in refrigerator door seal optimization research in the follow-up study.