期刊文献+
共找到47篇文章
< 1 2 3 >
每页显示 20 50 100
Impact of surface-reflected seismic waves on the seismic isolation performance of circular tunnel isolation layers
1
作者 LU Jiahui LUO Junjie +3 位作者 HUANG Xiangyun HONG Junliang HE YanXin ZHOU Fulin 《Journal of Mountain Science》 SCIE CSCD 2024年第3期901-917,共17页
Seismic isolation is an effective strategy to mitigate the risk of seismic damage in tunnels.However,the impact of surface-reflected seismic waves on the effectiveness of tunnel isolation layers remains under explored... Seismic isolation is an effective strategy to mitigate the risk of seismic damage in tunnels.However,the impact of surface-reflected seismic waves on the effectiveness of tunnel isolation layers remains under explored.In this study,we employ the wave function expansion method to provide analytical solutions for the dynamic responses of linings in an elastic half-space and an infinite elastic space.By comparing the results of the two models,we investigate the seismic isolation effect of tunnel isolation layers induced by reflected seismic waves.Our findings reveal significant differences in the dynamic responses of the lining in the elastic half-space and the infinitely elastic space.Specifically,the dynamic stress concentration factor(DSCF)of the lining in the elastic half-space exhibits periodic fluctuations,influenced by the incident wave frequency and tunnel depth,while the DSCF in the infinitely elastic space remain stable.Overall,the seismic isolation application of the tunnel isolation layer is found to be less affected by surface-reflected seismic waves.Our results provide valuable insights for the design and assessment of the seismic isolation effect of tunnel isolation layers. 展开更多
关键词 Circular tunnel seismic isolation Surface reflection Response of liners Wave-function expansion method
下载PDF
Development and performance evaluation of an innovative low-cost seismic isolator 被引量:5
2
作者 TAN Ping XU Kai +3 位作者 WANG Bin CHANG ChiaMing LIU Han ZHOU FuLin 《Science China(Technological Sciences)》 SCIE EI CAS 2014年第10期2050-2061,共12页
This paper proposes an innovative low-cost isolator with lightweight and cost-effective features for use in low-rise residential buildings.The low-cost laminated isolator is formed by plastic shims with unsaturated po... This paper proposes an innovative low-cost isolator with lightweight and cost-effective features for use in low-rise residential buildings.The low-cost laminated isolator is formed by plastic shims with unsaturated polyester fiber reinforcement between rubber layers.Performance tests are systematically carried out to characterize the isolator in terms of mechanic behavior(e.g.,compression,shear,and their relationship),dynamic properties(e.g.,damping),and ultimate states.A design guideline and associated criteria of the low-cost isolator are also provided and discussed in this study.To investigate more detailed behavior,a finite element model of the isolator is developed in ABAQUS and calibrated by the experimental data.The research presented in this paper makes significant contributions to the evaluation of the peak stress and strain demands on isolator’s components and provides technical support for the design and manufacturing of this new type of isolator. 展开更多
关键词 seismic isolation technology elastomeric isolator simple isolator finite element analysis
原文传递
Polynomial friction pendulum isolators(PFPIs)for seismic performance control of benchmark highway bridge 被引量:3
3
作者 Arijit Saha Pumachandra Saha Sanjaya Kumar Patro 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2017年第4期827-840,共14页
The seismic response of a benchmark highway bridge isolated with passive polynomial friction pendulum isolators (PFPIs) is investigated and subjected to six bidirectional ground motion records. The benchmark study i... The seismic response of a benchmark highway bridge isolated with passive polynomial friction pendulum isolators (PFPIs) is investigated and subjected to six bidirectional ground motion records. The benchmark study is based on a lumped mass finite-element model of the 91/5 highway overcrossing located in Southern California. The PFPI system possesses two important parameters; one is horizontal flexibility and the other is energy absorbing capacity through friction. The evaluation criteria of the benchmark bridge arc analyzed considering two parameters, time period of the isolator and coefficient of friction of the isolation surface. The results of the numerical study are compared with those obtained from the traditional friction pendulum system (FPS). Dual design performance of the PFPI system suppressed the displacement and acceleration response of the benchmark highway bridge. The dual design hysteresis loop of the PFPI system is the main advantage over the linear hysteresis loop of the FPS. The numerical result indicates that the seismic performance of the PFPI system is better than that of the traditional FPS isolated system. Further, it is observed that variations of the isolation time period and coefficient of friction of the FPS and PFPI systems have a significant effect on the peak responses of the benchmark highway bridge. 展开更多
关键词 benchmark highway bridge seismic isolation FPS PFPI evaluation criteria
下载PDF
Improving the Seismic Performance of Staircases in Building Structures with a Novel Isolator
4
作者 Yafei Zhang Ping Tan +1 位作者 Haitao Ma Marco Donà 《Computer Modeling in Engineering & Sciences》 SCIE EI 2020年第8期415-431,共17页
A staircase provides the main escape way from a building in an emergency.Unfortunately,it may suffer severe damages or even collapse during an earthquake.For improving the seismic performance of staircases,this paper ... A staircase provides the main escape way from a building in an emergency.Unfortunately,it may suffer severe damages or even collapse during an earthquake.For improving the seismic performance of staircases,this paper proposes an innovative staircase isolator with the features of lightweight,costeffective and ease of construction and replacement,which is formed by suitable engineering plastic shims between rubber layers.A connection construction scheme is also proposed for the isolated staircase.Systematic performance tests have been carried out to characterize the isolator in terms of mechanic behavior and ultimate states.The test results show that mechanical properties of the proposed staircase isolator are excellent and suitable for staircase in building structure.In order to investigate the influence of staircase on building structural responses,time history analyses of a typical building structure without staircase(WS),with fixed staircase(FS)and with isolated staircase(IS)are conducted and compared within the environment of SAP2000.Results show that staircase isolation can effectively eliminate the diagonal bracing effect of staircase slab and make structural components uniformly stressed.When the novel isolator is employed for staircase in a building structure,there is no vulnerable position in staircase and the performance of staircase in building structure can be greatly enhanced. 展开更多
关键词 seismic isolation seismic performance of staircases staircase isolation engineering-plastics rubber isolator rubber isolator
下载PDF
Uncertainty in the seismic performance of semi-active base isolation systems
5
作者 Xiaoyue Wang Zhe Qu 《Earthquake Research Advances》 CSCD 2023年第2期62-70,共9页
In a conventional base isolation system,minimizing the seismic responses of the superstructure is always at the cost of increasing the isolator's response.The semi-active control of the isolator has been considere... In a conventional base isolation system,minimizing the seismic responses of the superstructure is always at the cost of increasing the isolator's response.The semi-active control of the isolator has been considered an effective solution to such a dilemma.It tunes the real-time properties of the isolator according to preset rules to further reduce the superstructure's seismic responses without increasing that of the isolator or vice versa.However,the number of ground motion records used to design and validate the controller,i.e.,the preset rules,in existing studies is usually very small and therefore is suspectable if it is adequate to address the significant uncertainty in the shaking of future earthquakes.This paper critically reviews the performance of the proportional-integralderivative(PID),linear-quadratic regulator(LQR),and fuzzy controllers in semi-active base isolation systems with magnetorheological(MR)dampers subjected to highly uncertain ground motion inputs through numerical simulations.The results show that the control performance of the controllers varies significantly with the increasing number of input records,suggesting the necessity of using at least 50 ground motion records to appropriately assess the performance uncertainty of semi-active base isolation systems.More importantly,the superior performance of the optimized controllers is not guaranteed if the system is subjected to ground motions that are new to the controller,even if the controller has been optimized for thousands of existing ground motions.It highlights the need of improving the adaptability of the semi-active systems for uncertain ground motion inputs. 展开更多
关键词 seismic isolation Semi-active control MR damper Control performance UNCERTAINTY
下载PDF
Optimal design for rubber concrete layered periodic foundations based on the analytical approximations of band gaps and mapping relations
6
作者 Wu Qiaoyun Xu Zhifeng +2 位作者 Xu Peishan Zeng Wenxuan Chen Xuyong 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第3期593-608,共16页
The seismic performance of rubber concrete-layered periodic foundations are significantly influenced by their design,in which the band gaps play a paramount role.Aiming at providing better designs for these foundation... The seismic performance of rubber concrete-layered periodic foundations are significantly influenced by their design,in which the band gaps play a paramount role.Aiming at providing better designs for these foundations,this study first proposes and validates the analytical formulas to approximate the bounds of the first few band gaps.In addition,the mapping relations linking the frequencies of different band gaps are presented.Furthermore,an optimal design method for these foundations is developed,which is validated through an engineering example.It is demonstrated that ensuring the superstructure’s resonance zones are completely covered by the corresponding periodic foundation’s band gaps can achieve satisfactory vibration attenuation effects,which is a good strategy for the design of rubber concrete layered periodic foundations. 展开更多
关键词 periodic foundation band gap vibration attenuation seismic isolation optimal design
下载PDF
Study on a conical bearing for acceleration-sensitive equipment
7
作者 Pang Hui Xu Wen +1 位作者 Dai Junwu Jiang Tao 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第1期103-128,共26页
Seismic isolation effectively reduces seismic demands on building structures by isolating the superstructure from ground vibrations during earthquakes.However,isolation strategies give less attention to acceleration-s... Seismic isolation effectively reduces seismic demands on building structures by isolating the superstructure from ground vibrations during earthquakes.However,isolation strategies give less attention to acceleration-sensitive systems or equipment.Meanwhile,as the isolation layer’s displacement grows,the stiffness and frequency of traditional rolling and sliding isolation bearings increases,potentially causing self-centering and resonance concerns.As a result,a new conical pendulum bearing has been selected for acceleration-sensitive equipment to increase self-centering capacity,and additional viscous dampers are incorporated to enhance system damping.Moreover,the theoretical formula for conical pendulum bearings is supplied to analyze the device’s dynamic parameters,and shake table experiments are used to determine the proposed device’s isolation efficiency under various conditions.According to the test results,the newly proposed devices have remarkable isolation performance in terms of minimizing both acceleration and displacement responses.Finally,a numerical model of the isolation system is provided for further research,and the accuracy is demonstrated by the aforementioned experiments. 展开更多
关键词 seismic isolation acceleration-sensitive equipment the conical pendulum bearing shake table tests isolation performance numerical model
下载PDF
Three-dimensional seismic isolation bearing and its application in long span hangars 被引量:13
8
作者 Li Xiongyan Xue Suduo Cai Yancheng 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2013年第1期55-65,共11页
Based on the seismic response characteristics of space frame structures,a new type of seismic isolation bearing defined as a three-dimensional seismic isolation bearing(3DSIB) is developed in this paper.The bearing ... Based on the seismic response characteristics of space frame structures,a new type of seismic isolation bearing defined as a three-dimensional seismic isolation bearing(3DSIB) is developed in this paper.The bearing offers excellent properties such as multi-dimensional seismic isolation,reasonable rotation capability,good ability to resist lifting load,uncoupled stiffness in horizontal and vertical directions,etc.In the 3DSIB,the horizontal dimension is designed by combining the Teflon sliding device and helical spring,while the vertical dimension is developed by introducing disk springs or helical springs.The mathematical model of the 3DSIB was established and its performance with the critical parameters was tested on a shaking table.Furthermore,the 3DSIB was applied in a 120 m span hangar structure and simulated using SAP2000 software to evaluate its performance in practical structures.The performance of the structures with and without 3DSIB was compared.It is shown that the hangar structure with 3D bearings achieves a better performance.The axial force and acceleration response of the structures with 3DSIB are effectively reduced,while the displacement response of the bearing is within the predetermined range. 展开更多
关键词 three-dimensional seismic isolation bearing (3DSIB) seismic isolation HANGAR axial force acceleration response
下载PDF
Seismic isolation analysis of FPS bearings in spatial lattice shell structures 被引量:14
9
作者 Yong-Chul Kim Xue Suduo +2 位作者 Zhuang Peng Zhao Wei Li Chenghao 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2010年第1期93-102,共10页
A theoretical model of a friction pendulum system (FPS) is introduced to examine its application for the seismic isolation of spatial lattice shell structures. An equation of motion of the lattice shell with FPS bea... A theoretical model of a friction pendulum system (FPS) is introduced to examine its application for the seismic isolation of spatial lattice shell structures. An equation of motion of the lattice shell with FPS bearings is developed. Then, seismic isolation studies are performed for both double-layer and single-layer lattice shell structures under different seismic input and design parameters of the FPS. The influence of frictional coefficients and radius of the FPS on seismic performance are discussed. Based on the study, some suggestions for seismic isolation design of lattice shells with FPS bearings are given and conclusions are made which could be helpful in the application of FPS. 展开更多
关键词 seismic isolation friction pendulum system spatial structure lattice shell parameter analysis
下载PDF
Resilience-based retrofitting of existing urban RC-frame buildings using seismic isolation 被引量:12
10
作者 Yang Cantian Xie Linlin +4 位作者 Li Aiqun Zeng Demin Jia Junbo Chen Xi Chen Min 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2020年第4期839-853,共15页
The improvement of the seismic resilience of existing reinforced-concrete(RC) frame buildings, which is essential for the seismic resilience of a city, has become a critical issue. Although seismic isolation is an eff... The improvement of the seismic resilience of existing reinforced-concrete(RC) frame buildings, which is essential for the seismic resilience of a city, has become a critical issue. Although seismic isolation is an effective method for improving the resilient performance of such buildings, target-oriented quantitative improvements of the resilient performance of these buildings have been reported rarely. To address this gap, the seismic resilience of two existing RC frame buildings located in a high seismic intensity region of China were assessed based on the Chinese Standard for Seismic Resilience Assessment of Buildings. The critical engineering demand parameters(EDPs) affecting the seismic resilience of such buildings were identified. Subsequently, the seismic resilience of buildings retrofitted with different isolation schemes(i.e., yield ratios) were evaluated and compared, with emphasis on the relationships among yield ratios, EDPs, and levels of seismic resilience. Accordingly, to achieve the highest level of seismic resilience with respect to the Chinese standard, a yield ratio of 3% was recommended and successfully applied to the target-oriented design for the seismic-resilience improvement of an existing RC frame building. The research outcome can provide an important reference for the resilience-based retrofitting of existing RC frame buildings using seismic isolation in urban cities. 展开更多
关键词 existing urban RC frame building retrofitting using seismic isolation seismic resilience yield ratio
下载PDF
Equivalent series system to model a multiple friction pendulum system with numerous sliding interfaces for seismic analyses 被引量:7
11
作者 C.S.Tsai H.C.Su T.C.Chiang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2014年第1期85-99,共15页
Current structural analysis software programs offer few if any applicable device-specifi c hysteresis rules or nonlinear elements to simulate the precise mechanical behavior of a multiple friction pendulum system(MFPS... Current structural analysis software programs offer few if any applicable device-specifi c hysteresis rules or nonlinear elements to simulate the precise mechanical behavior of a multiple friction pendulum system(MFPS) with numerous sliding interfaces.Based on the concept of subsystems,an equivalent series system that adopts existing nonlinear elements with parameters systematically calculated and mathematically proven through rigorous derivations is proposed.The aim is to simulate the characteristics of sliding motions for an MFPS isolation system with numerous concave sliding interfaces without prior knowledge of detailed information on the mobilized forces at various sliding stages.An MFPS with numerous concave sliding interfaces and one articulated or rigid slider located between these interfaces is divided into two subsystems: the fi rst represents the concave sliding interfaces above the slider,and the second represents those below the slider.The equivalent series system for the entire system is then obtained by connecting those for each subsystem in series.The equivalent series system is validated by comparing numerical results for an MFPS with four sliding interfaces obtained from the proposed method with those from a previous study by Fenz and Constantinou.Furthermore,these numerical results demonstrate that an MFPS isolator with numerous concave sliding interfaces,which may have any number of sliding interfaces,is a good isolation device to protect structures from earthquake damage through appropriate designs with controllable mechanisms. 展开更多
关键词 seismic isolation base isolation earthquake engineering multiple friction pendulum system structural control mathematical modeling equivalent series system
下载PDF
Study of the seismic performance of expansion double spherical seismic isolation bearings for continuous girder bridges 被引量:11
12
作者 Peng, Tianbo Yu, Xuntao +1 位作者 Wang, Zhennan Han, Lei 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2012年第2期163-172,共10页
The development of an expansion double spherical seismic isolation (DSSI) bearing by modifying the fixed DSSI bearing is described in this paper. The expansion DSSI bearing is characterized by its good energy dissipat... The development of an expansion double spherical seismic isolation (DSSI) bearing by modifying the fixed DSSI bearing is described in this paper. The expansion DSSI bearing is characterized by its good energy dissipation and horizontal displacement capacity and has been successfully integrated into the seismic design of several important engineering projects in China. It is envisioned to be used as a substitute for ordinary expansion bearings in continuous girder bridges to distribute the longitudinal earthquake action among all the piers. Its development, configuration and working mechanism are introduced first. The test method and the seismic performance of an expansion DSSI bearing are then briefly described. A theoretical analysis followed by a numerical analysis for an actual four-span continuous girder bridge are provided as an example, and it is concluded that the expansion DSSI bearing can be integrated into the seismic design of continuous girder bridges. 展开更多
关键词 double spherical seismic isolation (DSSI) bearing seismic isolation seismic performance continuous girder bridge
下载PDF
A new seismic isolation system and its feasibility study 被引量:8
13
作者 Jia Gaofeng~+ and Shi Zhifei~(++) School of Civil Engineering,Beijing Jiaotong University,Beijing 100044,China Graduated Student ++ Professor 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2010年第1期75-82,共8页
This paper introduces a new seismic isolation system called a periodic foundation (PF), where inclusions are periodically arranged. The PF is different from traditional base isolation in that it causes a fundamental... This paper introduces a new seismic isolation system called a periodic foundation (PF), where inclusions are periodically arranged. The PF is different from traditional base isolation in that it causes a fundamental frequency shift in the structure, thus reducing its response and generating a frequency gap. If the frequency contents of a seismic wave fall into the gap, it can not propagate in the foundation. Thus, it will exert no influence on the structure above. A systematic study of the band of frequency gap for a 2D PF is conducted. The influence of physical and geometrical parameters such as density and elastic modulus as well as filling fraction of the PF and its materials on the band of frequency gap are investigated, and a design with a frequency gap as low as 2.49-3.72 Hz is achieved. This band of frequency gap corresponds well to the design spectra in earthquake engineering. Numerical simulations of a six-story frame structure with different foundations demonstrate that a proposed PF can greatly reduce the seismic response of an isolated structure. This investigation shows that PFs have great potential in future applications of seismic isolation technology. 展开更多
关键词 seismic isolation periodic foundation band of frequency gap
下载PDF
Reduction of structural response to near fault earthquakes by seismic isolation columns and variable friction dampers 被引量:5
14
作者 Y.Ribakov 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2010年第1期113-122,共10页
This paper focuses on the investigation of a hybrid seismic isolation system with passive variable friction dampers for protection of structures against near fault earthquakes. The seismic isolation can be implemented... This paper focuses on the investigation of a hybrid seismic isolation system with passive variable friction dampers for protection of structures against near fault earthquakes. The seismic isolation can be implemented by replacing the conventional columns fixed to the foundations by seismic isolating ones. These columns allow horizontal displacement between the superstructure and the foundations and decouple the building from the damaging earthquake motion. As a result, the forces in the structural elements decrease and damage that may be caused to the building by the earthquake significantly decreases. However, this positive effect is achieved on account of displacements occurring in the isolating columns. These displacements become very large when the structure is subjected to a strong earthquake. In this case, impact may occur between the parts of the isolating column yielding their damage or collapse. In order to limit the displacements in the isolating columns, it is proposed to add variable friction dampers. A method for selecting the dampers' properties is proposed. It is carried out using an artificial ground motion record and optimal active control algorithm. Numerical simulation of a sevenstory structure shows that the proposed method allows efficient reduction in structural response and limits the displacements at the seismic isolating columns. 展开更多
关键词 seismic isolating columns variable friction dampers hybrid seismic isolation near fault earthquakes control algorithm
下载PDF
Improving the seismic performance of base-isolated liquid storage tanks with supplemental linear viscous dampers 被引量:6
15
作者 Alexandros Tsipianitis Yiannis Tsompanakis 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2022年第1期269-282,共14页
Large tanks are extensively used for storing water,petrochemicals and fuels.Since they are often cited in earthquake-prone areas,the safe and continuous operation of these important structures must be ensured even whe... Large tanks are extensively used for storing water,petrochemicals and fuels.Since they are often cited in earthquake-prone areas,the safe and continuous operation of these important structures must be ensured even when severe earthquakes occur,since their failure could have devastating financial and socio-environmental consequences.Base-isolation has been widely adopted for the efficient seismic protection of such critical facilities.However,base-isolated tanks can be located relatively close to active faults that generate strong excitations with special characteristics.Consequently,viscous dampers can be incorporated into the isolation system to reduce excessive displacement demands and to avoid overconservative isolator design.Nonetheless,only a few studies have focused on the investigation of seismic response of base-isolated liquid storage tanks in conjunction with supplemental viscous dampers.Therefore,the impact of the addition of supplemental linear viscous dampers on the seismic performance of tanks isolated by single friction pendulum devices is investigated herein.Four levels of supplemental damping are assessed and compared with respect to isolators′displacement capacity and accelerations that are transferred to the tanks. 展开更多
关键词 liquid storage tanks linear viscous dampers seismic isolation concave sliding bearings seismic vulnerability
下载PDF
Nonlinear dynamic analysis of multi-base seismically isolated structures with uplift potentialⅡ:verification examples 被引量:5
16
作者 Panayiotis C.Roussis Panos C.Tsopelas Michael C.Constantinou 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2010年第1期83-91,共9页
The work presented in this paper serves as numerical verification of the analytical model developed in the companion paper for nonlinear dynamic analysis of multi-base seismically isolated structures. To this end, two... The work presented in this paper serves as numerical verification of the analytical model developed in the companion paper for nonlinear dynamic analysis of multi-base seismically isolated structures. To this end, two numerical examples have been analyzed using the computational algorithm incorporated into program 3D-BASIS-ME-MB, developed on the basis of the newly-formulated analytical model. The first example concerns a seven-story model structure that was tested on the earthquake simulator at the University at Buflhlo and was also used as a verification example for program SAP2000. The second example concerns a two-tower, multi-story structure with a split-level seismic-isolation system. For purposes of verification, key results produced by 3D-BASIS-ME-MB are compared to experimental results, or results obtained from other structural/finite element programs. In both examples, the analyzed structure is excited under conditions of bearing uplift, thus yielding a case of much interest in verifying the capabilities of the developed analysis tool. 展开更多
关键词 seismic isolation nonlinear dynamic analysis UPLIFT VERIFICATION multiple superstructures/bases
下载PDF
Seismic fragility of structures isolated by single concave sliding devices for different soil conditions 被引量:5
17
作者 P.Castaldo G.Amendola M.Ripani 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2018年第4期869-891,共23页
This study deals with the seismic fragility of elastic structural systems equipped with single concave sliding(friction pendulum system(FPS)) isolators considering different soil conditions. The behavior of these ... This study deals with the seismic fragility of elastic structural systems equipped with single concave sliding(friction pendulum system(FPS)) isolators considering different soil conditions. The behavior of these systems is analyzed by employing a two-degree-of-freedom model, whereas the FPS response is described by means of a velocity-dependent model. The uncertainty in the seismic inputs is taken into account by considering artificial seismic excitations modelled as timemodulated filtered Gaussian white noise random processes of different intensity within the power spectral density method. In particular, the filter parameters, which control the frequency content of the random excitations, are calibrated to describe stiff, medium and soft soil conditions. The sliding friction coefficient at large velocity is also considered as a random variable modelled through a uniform probability density function. Incremental dynamic analyses are developed in order to evaluate the probabilities of exceeding different limit states related to both the reinforced concrete(RC) superstructure and isolation level, defining the seismic fragility curves within an extensive parametric study carried out for different structural system properties and soil conditions. The abovementioned seismic fragility curves are useful to evaluate the seismic reliability of base-isolated elastic systems equipped with FPS and located in any site for any soil condition. 展开更多
关键词 friction pendulum devices seismic isolation soil condition frequency content seismic fragility
下载PDF
Study on the seismic performance of a double spherical seismic isolation bearing 被引量:4
18
作者 Peng Tianbo Li Jianzhong Xu Yan Fan Lichu 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2008年第4期439-446,共8页
In this paper, the configuration and working mechanism of the recently developed double spherical seismic isolation (DSSI) bearing are introduced in detail. Then, vertical displacement of the DSSI bearing due to sli... In this paper, the configuration and working mechanism of the recently developed double spherical seismic isolation (DSSI) bearing are introduced in detail. Then, vertical displacement of the DSSI bearing due to sliding on a spherical surface is analyzed. The results from seismic performance testing of the bearing are given, and a numerical analysis of a four span continuous girder bridge is performed. The numerical analysis compares the influence of three different bearing arrangement schemes on the structural seismic response, and the results show that the DSSI bearing is effective in increasing the vertical load bearing capacity, reducing the vertical displacement, and controlling the energy dissipation capacity within a certain range. 展开更多
关键词 DSSI bearing seismic isolation vertical displacement energy dissipation continuous girder bridges
下载PDF
Research and application on three-dimensional seismic and vibration isolation for building 被引量:5
19
作者 魏陆顺 周福霖 +1 位作者 谭平 任珉 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2011年第1期62-66,共5页
This paper presents the study of a three-dimensional(3D) isolation system.Firstly,the authors investigated the effects of an innovative 3D isolator,which was composed of a connecting plate,a rubber pad for vibration i... This paper presents the study of a three-dimensional(3D) isolation system.Firstly,the authors investigated the effects of an innovative 3D isolator,which was composed of a connecting plate,a rubber pad for vibration isolation in the vertical direction and a horizontal rubber bearing for seismic isolation in both horizontal directions.Secondly,the authors designed such a vibration isolation system and installed it underneath two specific residential buildings which were built directly over an existing subway communication hub platform in Beijing.These buildings required good performance vibration and seismic isolation system to reduce the impact from the running of nearby subway trains.Finally,in situ tests were conducted for both the isolated and the non-isolated buildings for the purpose of comparison.The test results showed that the maximum acceleration response level of the isolated superstructure is reduced by 10% as compared to that of the platform.The maximum attenuation of vibration reaches up to 25 dB.The 3D system explored in this paper is very effective in control and suppression of building vibration induced by earthquakes or running of trains. 展开更多
关键词 three-dimensional seismic and vibration isolator vertical vibration isolation horizontal seismic isolation engineering application
下载PDF
Recent progress and application on seismic isolation energy dissipation and control for structures in China 被引量:20
20
作者 Zhou Fulin Tan Ping 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2018年第1期19-27,共9页
China is a country where 100% of the territory is located in a seismic zone. Most of the strong earthquakes are over prediction. Most fatalities are caused by structural collapse. Earthquakes not only cause severe dam... China is a country where 100% of the territory is located in a seismic zone. Most of the strong earthquakes are over prediction. Most fatalities are caused by structural collapse. Earthquakes not only cause severe damage to structures, but can also damage non-structural elements on and inside of facilities. This can halt city life, and disrupt hospitals, airports, bridges, power plants, and other infrastructure. Designers need to use new techniques to protect structures and facilities inside. Isolation, energy dissipation and, control systems are more and more widely used in recent years in China. Currently, there are nearly 6,500 structures with isolation and about 3,000 structures with passive energy dissipation or hybrid control in China. The mitigation techniques are applied to structures like residential buildings, large or complex structures, bridges, underwater tunnels, historical or cultural relic sites, and industrial facilities, and are used for retrofitting of existed structures. This paper introduces design rules and some new and innovative devices for seismic isolation, energy dissipation and hybrid control for civil and industrial structures. This paper also discusses the development trends for seismic resistance, seismic isolation, passive and active control techniques for the future in China and in the world. 展开更多
关键词 seismic isolation energy dissipation passive contro hybrid control
下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部