期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Interaction between Cationic Surfactants and Bromopyrogallol Red as well as Its Application for the Sensitive and Selective Determination of Mo in Mo/W Binary Mixtures
1
作者 Xi Rong HUANG Shu Hua HAN +2 位作者 Wen Juan ZHANG Yong Quan YIN Gui Ying XU (Department of Chemistry, Shandong University, Jinan 250100) 《Chinese Chemical Letters》 SCIE CAS CSCD 1997年第6期523-526,共4页
Prior to formation of the micelles of cationic surfactant (CSF), bromopyrogallol red (BPR) could exist in the forms of both monomer and oligomer After that, however, only BPR monomer existed. Nonionic surfactant OP-10... Prior to formation of the micelles of cationic surfactant (CSF), bromopyrogallol red (BPR) could exist in the forms of both monomer and oligomer After that, however, only BPR monomer existed. Nonionic surfactant OP-10 favoured the oligomerization of BPR monomer. The mixed micellar media prepared by mixing CSF and OP-10 in an appropriate ratio could be used for the sensitive and selective determination of Mo in Mo/W binary mixtures. 展开更多
关键词 well MO Interaction between Cationic Surfactants and Bromopyrogallol Red as well as Its Application for the Sensitive and selective determination of Mo in Mo/W Binary Mixtures
下载PDF
SELECTIVE SULFUR DIOXIDE DETERMINATION BY GAS DIFFUSION FLOW INJECTION ANALYSIS WITH CHEMILUMINESCENT DETECTION
2
作者 Yong He BAO Qi Jun SONG Department of Chemistry,XingJiang University,Urumchi,830046 《Chinese Chemical Letters》 SCIE CAS CSCD 1991年第4期313-314,共2页
Sulfur dioxide has been found to decrease the chemiluminescence of luminol-iodine system.A new determination method for sulfur dioxide in atmosphere is developed by applying this reaction to a flow injection gas diffu... Sulfur dioxide has been found to decrease the chemiluminescence of luminol-iodine system.A new determination method for sulfur dioxide in atmosphere is developed by applying this reaction to a flow injection gas diffusion separation system.This permits the determination of sulfur dioxide selectively and rapidly. 展开更多
关键词 FLOW selective SULFUR DIOXIDE determination BY GAS DIFFUSION FLOW INJECTION ANALYSIS WITH CHEMILUMINESCENT DETECTION GAS
下载PDF
DETERMINATION OF SERUM ALBUMIN USING A SILVER ION SELECTIVE ELECTRODE
3
作者 Feng Lian LU (Department of Chemistry, Zhengzhou University, Zhengzhou, 450052) 《Chinese Chemical Letters》 SCIE CAS CSCD 1994年第10期879-880,共2页
In this paper is reported a new method of determining serum albumin with potentiometry. The silver ion selective electrode was used as working electrode and S. C. E as reference electrode. By controlling the ionic s... In this paper is reported a new method of determining serum albumin with potentiometry. The silver ion selective electrode was used as working electrode and S. C. E as reference electrode. By controlling the ionic strength, PH and temperature constant, a good linear relationship was obtained between the cell potential and albumin concentration. This method .possessed characters-of operating simplicity, rapidity and directness. The samples could be detected directly and the results were in accordance with the values detected by classic K method. 展开更多
关键词 ION determination OF SERUM ALBUMIN USING A SILVER ION selective ELECTRODE
下载PDF
Two-Stage Planning of Distributed Power Supply and Energy Storage Capacity Considering Hierarchical Partition Control of Distribution Network with Source-Load-Storage
4
作者 Junhui Li Yuqing Zhang +4 位作者 Can Chen Xiaoxiao Wang Yinchi Shao Xingxu Zhu Cuiping Li 《Energy Engineering》 EI 2024年第9期2389-2408,共20页
Aiming at the consumption problems caused by the high proportion of renewable energy being connected to the distribution network,it also aims to improve the power supply reliability of the power system and reduce the ... Aiming at the consumption problems caused by the high proportion of renewable energy being connected to the distribution network,it also aims to improve the power supply reliability of the power system and reduce the operating costs of the power system.This paper proposes a two-stage planning method for distributed generation and energy storage systems that considers the hierarchical partitioning of source-storage-load.Firstly,an electrical distance structural index that comprehensively considers active power output and reactive power output is proposed to divide the distributed generation voltage regulation domain and determine the access location and number of distributed power sources.Secondly,a two-stage planning is carried out based on the zoning results.In the phase 1 distribution network-zoning optimization layer,the network loss is minimized so that the node voltage in the area does not exceed the limit,and the distributed generation configuration results are initially determined;in phase 2,the partition-node optimization layer is planned with the goal of economic optimization,and the distance-based improved ant lion algorithm is used to solve the problem to obtain the optimal distributed generation and energy storage systemconfiguration.Finally,the IEEE33 node systemwas used for simulation.The results showed that the voltage quality was significantly improved after optimization,and the overall revenue increased by about 20.6%,verifying the effectiveness of the two-stage planning. 展开更多
关键词 Zoning control two-stage planning site selection and capacity determination optimized scheduling improved ant lion algorithm
下载PDF
上一页 1 下一页 到第