We first experimentally demonstrate a laser-diode end-pumped self-Q-switched and mode-locked Nd,Cr:YAG green laser with a KTP crystal as the intra-cavity frequency doubler. The device produces an average output power...We first experimentally demonstrate a laser-diode end-pumped self-Q-switched and mode-locked Nd,Cr:YAG green laser with a KTP crystal as the intra-cavity frequency doubler. The device produces an average output power of 680 mW at 532 nm. The corresponding pulse width of the Q-switched envelope of the green laser is 170 + 20 ns. The mode-locked pulses have a repetition rate of approximately 183 MHz and the average pulse duration is estimated to be around sub-nanosecond. It is found that the intra-cavity frequency doubling greatly improves the modulation depth and stability of the mode-locked pulses within the Q-switched envelope.展开更多
A self-balanced charge pump (CP) with fast lock circuit to achieve nearly zero phase error is proposed and analyzed. The proposed CP is designed based on the SMIC 0.25μm 1P5M complementary metal oxide semiconductor...A self-balanced charge pump (CP) with fast lock circuit to achieve nearly zero phase error is proposed and analyzed. The proposed CP is designed based on the SMIC 0.25μm 1P5M complementary metal oxide semiconductor (CMOS) process with a 2.5 V supply voltage, HSPICE simulation shows that even if the mismatch of phase/frequency detector (PFD) was beyond 10%, the charge pump could still keep nearly zero phase error, Incorporated fast lock circuit can shorten start-up time to below 300 ns.展开更多
In this paper, we adopt cloud computing in a specific scientific computing field for its virtualization, distribution and dynamic extendibility as follows: We obtain high-energy parabolic self-similar pulses by numeri...In this paper, we adopt cloud computing in a specific scientific computing field for its virtualization, distribution and dynamic extendibility as follows: We obtain high-energy parabolic self-similar pulses by numerical simulation using our non-distributed passively mode-locked Er-doped fiber laser model. For researching characteristics of these wave-breaking-free self-similar pulses, chirp of them must be extracted. We propose several time-frequency analysis methods adopted in chirp extraction of ultra-short optical pulses for the first time and discuss the advantages and disadvantages of them in this particular application.展开更多
目的:颈前路减压融合术是治疗退行性颈椎病的经典手术方式,钉板的使用增加了融合率及稳定性的同时,间接导致了邻近椎体退变和术后吞咽困难的发生。文章通过Meta分析方法比较ROI-C^(TM)自锁系统和传统融合器联合钉板内固定治疗退行性颈...目的:颈前路减压融合术是治疗退行性颈椎病的经典手术方式,钉板的使用增加了融合率及稳定性的同时,间接导致了邻近椎体退变和术后吞咽困难的发生。文章通过Meta分析方法比较ROI-C^(TM)自锁系统和传统融合器联合钉板内固定治疗退行性颈椎病患者的临床结果和并发症情况,为颈前路减压融合术中内固定方式的选择提供循证学支持。方法:检索中国知网、万方、维普、PubMed、Cochrane Library、Web of Science和Embase数据库,检索关于颈前路减压融合术中应用ROI-C^(TM)自锁系统与融合器联合钉板内固定治疗退行性颈椎病的中英文文献。检索时间范围为各数据库建库至2023年7月。由2名研究者严格按照纳入与排除标准选择文献,采用Cochrane偏倚风险工具对随机对照试验进行质量评价,NOS量表对队列研究进行质量评价。采用RevMan 5.4软件进行Meta分析。结局指标包括手术时间、术中出血量、日本骨科协会(Japanese Orthopaedic Association Scores,JOA)评分、颈椎功能障碍指数、C_(2)-C_(7)Cobb角、融合率、邻近椎体退变发生率、融合器沉降率和吞咽困难发生率。结果:共纳入13项研究,其中回顾性队列研究11项,随机对照试验2项,共1136例患者,ROI-C组569例,融合器联合钉板组567例。Meta分析结果显示:ROI-C组与融合器联合钉板组在手术时间(MD=-15.52,95%CI:-18.62至-12.42,P<0.00001),术中出血量(MD=-24.53,95%CI:-32.46至-16.61,P<0.00001),术后邻近节段退变率(RR=0.40,95%CI:0.27-0.60,P<0.00001)和术后总吞咽困难发生率(RR=0.18,95%CI:0.13-0.26,P<0.00001)均具有显著性差异。两者在术后JOA评分、颈椎功能障碍指数、C_(2)-C_(7)Cobb角、融合率和融合器沉降率方面无显著性差异(P≥0.05)。结论:在颈椎前路减压融合术中应用ROI-C^(TM)自锁系统与传统融合器联合钉板内固定治疗退行性颈椎病均可达到满意的临床效果,ROI-C^(TM)自锁系统操作更加简单,相比融合器联合钉板内固定能明显减少手术时间及术中出血量,在减少术后吞咽困难及邻近节段退变发生率等方面具有明显优势,对于跳跃型颈椎病及邻椎病翻修患者,更加推荐使用ROI-C^(TM)自锁系统。但鉴于其可能存在较高的沉降率,对于多节段且合并融合器沉降高危因素如骨质疏松、椎体终板破损的退行性颈椎病患者,仍建议使用融合器联合钉板内固定。展开更多
致密砂岩气藏孔隙度、渗透率较低,微观孔喉尺度细小,在生产及压裂过程中极易产生水锁伤害。为开展致密储层防水锁作用机理研究,将常规岩心自吸实验、防水锁剂抑制水锁伤害实验与低场核磁共振技术(nuclear magnetic resonance,NMR)相结合...致密砂岩气藏孔隙度、渗透率较低,微观孔喉尺度细小,在生产及压裂过程中极易产生水锁伤害。为开展致密储层防水锁作用机理研究,将常规岩心自吸实验、防水锁剂抑制水锁伤害实验与低场核磁共振技术(nuclear magnetic resonance,NMR)相结合,从微观角度揭示致密砂岩储层微纳米级孔喉中的防水锁作用机理,为致密砂岩气藏防水锁相关研究提供理论依据。结果表明:加入防水锁添加剂后,流体表面张力下降,接触角增大,自吸速率变慢,渗透率有一定程度恢复;在此基础上,通过核磁共振T 2谱从微观角度评价缓慢自吸阶段液体在不同孔喉尺度范围内的液相水锁滞留现象,其中加入防水锁添加剂后在自吸20 h时在较小孔喉处自吸液相平均占比为38.61%,整体孔喉平均液相占比为35.79%。而在未加入防水锁试剂的样品中在自吸20 h时在较小孔喉处液相占比为67.48%,整体孔喉占比为54.52%;通过防水锁剂抑制水锁伤害实验得出,加入防水锁剂后渗透率恢复程度在15.38%~20.19%,整体液相滞留占比平均下降幅度在10.73%。防水锁剂有效地降低较小孔候处液相滞留占比,降低流体表面张力以及增大岩心疏水性能,揭示了致密砂岩气藏防水锁作用机理,为致密砂岩气藏降低水锁伤害程度、提高返排效率,为实现高效开发提供理论支撑。展开更多
基金Project supported by the National Natural Science Foundation of China (Grant Nos 60278024 and 60438020).
文摘We first experimentally demonstrate a laser-diode end-pumped self-Q-switched and mode-locked Nd,Cr:YAG green laser with a KTP crystal as the intra-cavity frequency doubler. The device produces an average output power of 680 mW at 532 nm. The corresponding pulse width of the Q-switched envelope of the green laser is 170 + 20 ns. The mode-locked pulses have a repetition rate of approximately 183 MHz and the average pulse duration is estimated to be around sub-nanosecond. It is found that the intra-cavity frequency doubling greatly improves the modulation depth and stability of the mode-locked pulses within the Q-switched envelope.
基金Supported by the National High Technology Re-search and Development Programof China (2004AA122310)
文摘A self-balanced charge pump (CP) with fast lock circuit to achieve nearly zero phase error is proposed and analyzed. The proposed CP is designed based on the SMIC 0.25μm 1P5M complementary metal oxide semiconductor (CMOS) process with a 2.5 V supply voltage, HSPICE simulation shows that even if the mismatch of phase/frequency detector (PFD) was beyond 10%, the charge pump could still keep nearly zero phase error, Incorporated fast lock circuit can shorten start-up time to below 300 ns.
基金supported by National Natural Science Foundation of China and Scientific Forefront and Interdisciplinary Innovation Project, Jilin University under Grants No. 60372061,200903296
文摘In this paper, we adopt cloud computing in a specific scientific computing field for its virtualization, distribution and dynamic extendibility as follows: We obtain high-energy parabolic self-similar pulses by numerical simulation using our non-distributed passively mode-locked Er-doped fiber laser model. For researching characteristics of these wave-breaking-free self-similar pulses, chirp of them must be extracted. We propose several time-frequency analysis methods adopted in chirp extraction of ultra-short optical pulses for the first time and discuss the advantages and disadvantages of them in this particular application.
文摘目的:颈前路减压融合术是治疗退行性颈椎病的经典手术方式,钉板的使用增加了融合率及稳定性的同时,间接导致了邻近椎体退变和术后吞咽困难的发生。文章通过Meta分析方法比较ROI-C^(TM)自锁系统和传统融合器联合钉板内固定治疗退行性颈椎病患者的临床结果和并发症情况,为颈前路减压融合术中内固定方式的选择提供循证学支持。方法:检索中国知网、万方、维普、PubMed、Cochrane Library、Web of Science和Embase数据库,检索关于颈前路减压融合术中应用ROI-C^(TM)自锁系统与融合器联合钉板内固定治疗退行性颈椎病的中英文文献。检索时间范围为各数据库建库至2023年7月。由2名研究者严格按照纳入与排除标准选择文献,采用Cochrane偏倚风险工具对随机对照试验进行质量评价,NOS量表对队列研究进行质量评价。采用RevMan 5.4软件进行Meta分析。结局指标包括手术时间、术中出血量、日本骨科协会(Japanese Orthopaedic Association Scores,JOA)评分、颈椎功能障碍指数、C_(2)-C_(7)Cobb角、融合率、邻近椎体退变发生率、融合器沉降率和吞咽困难发生率。结果:共纳入13项研究,其中回顾性队列研究11项,随机对照试验2项,共1136例患者,ROI-C组569例,融合器联合钉板组567例。Meta分析结果显示:ROI-C组与融合器联合钉板组在手术时间(MD=-15.52,95%CI:-18.62至-12.42,P<0.00001),术中出血量(MD=-24.53,95%CI:-32.46至-16.61,P<0.00001),术后邻近节段退变率(RR=0.40,95%CI:0.27-0.60,P<0.00001)和术后总吞咽困难发生率(RR=0.18,95%CI:0.13-0.26,P<0.00001)均具有显著性差异。两者在术后JOA评分、颈椎功能障碍指数、C_(2)-C_(7)Cobb角、融合率和融合器沉降率方面无显著性差异(P≥0.05)。结论:在颈椎前路减压融合术中应用ROI-C^(TM)自锁系统与传统融合器联合钉板内固定治疗退行性颈椎病均可达到满意的临床效果,ROI-C^(TM)自锁系统操作更加简单,相比融合器联合钉板内固定能明显减少手术时间及术中出血量,在减少术后吞咽困难及邻近节段退变发生率等方面具有明显优势,对于跳跃型颈椎病及邻椎病翻修患者,更加推荐使用ROI-C^(TM)自锁系统。但鉴于其可能存在较高的沉降率,对于多节段且合并融合器沉降高危因素如骨质疏松、椎体终板破损的退行性颈椎病患者,仍建议使用融合器联合钉板内固定。