The characteristics of traditional acoustic vortices(AVs) were verified by the cross-sectional axisymmetric pressure distributions with perfect phase spirals around the center pressure null. In order to generate a non...The characteristics of traditional acoustic vortices(AVs) were verified by the cross-sectional axisymmetric pressure distributions with perfect phase spirals around the center pressure null. In order to generate a non-axisymmetric pressure distribution, the concept of power-exponent-phase was first introduced into the formation of AV beams, named “powerexponent-phase acoustic vortices(PAVs)” in this paper. Based on a ring-array of sector transducers, the helical distribution of the low-pressure valley in cross-sections of PAVs, which enables particles to move from a distant position to the center low-potential well along a certain spiral passageway, was proved theoretically. The particle manipulation behavior for PAVs with a power order of 2 is numerically modeled and experimentally confirmed. The results show that PAVs with a nonaxisymmetric spiral pressure distribution can be used to realize the directional transport of particles in an enlarged scope,suggesting prospective application potential in biomedical engineering.展开更多
Cracks, especially small cracks are di cult to be detected in oil and gas transportation pipelines buried underground or covered with layers of material by using the traditional ultrasonic inspection techniques. There...Cracks, especially small cracks are di cult to be detected in oil and gas transportation pipelines buried underground or covered with layers of material by using the traditional ultrasonic inspection techniques. Therefore, a new com?posite ultrasonic transducer array with three acoustic beam incidence modes is developed. The space model of the array is also established to obtain the defect reflection point location. And the crack ultrasound image is thus formed through a series of small cubical elements expanded around the point locations by using the projection of binariza?tion values extracted from the received ultrasonic echo signals. Laboratory experiments are performed on a pipeline sample with di erent types of cracks to verify the e ectiveness and performance of the proposed technique. From the image, the presence of small cracks can be clearly observed, in addition to the sizes and orientations of the cracks. The proposed technique can not only inspect common flaws, but also detect cracks with various orientations, which is helpful for defect evaluation in pipeline testing.展开更多
An air parametric array can generate a highly directional beam of audible sound in air,which has a wide range of applications in targeted audio delivery.Capacitive micromachined ultrasonic transducer(CMUTs)have great ...An air parametric array can generate a highly directional beam of audible sound in air,which has a wide range of applications in targeted audio delivery.Capacitive micromachined ultrasonic transducer(CMUTs)have great potential for air-coupled applications,mainly because of their low acoustic impedance.In this study,an air-coupled CMUT array is designed as an air parametric array.A hexagonal array is proposed to improve the directivity of the sound generated.A finite element model of the CMUT is established in COMSOL software to facilitate the choice of appropriate structural parameters of the CMUT cell.The CMUT array is then fabricated by a wafer bonding process with high consistency.The performances of the CMUT are tested to verify the accuracy of the finite element analysis.By optimizing the component parameters of the bias-T circuit used for driving the CMUT,DC and AC voltages can be effectively applied to the top and bottom electrodes of the CMUT to provide efficient ultrasound transmission.Finally,the prepared hexagonal array is successfully used to conduct preliminary experiments on its application as an air parametric array.展开更多
Hilbert transformation and improved ellipse localization method is applied in ultrasonic transducer array tomography to detect defect of metal plate.By combining the improved ellipse localization method and time-rever...Hilbert transformation and improved ellipse localization method is applied in ultrasonic transducer array tomography to detect defect of metal plate.By combining the improved ellipse localization method and time-reversal method,the new ultrasonic tomography algorithm employs smooth Hilbert envelope instead of discrete amplitude to reconstruct defect image.An ultrasonic tomography system with six transducers is built to evaluate the effectiveness of the new ultrasonic tomography algorithm.The S0 mode Lamb wave is excited on special condition,and the mode of received signal is identified by Vigner-Wille distribution.The gray value of image area is defined by envelope of the reflected S0 mode Lamb wave signal from defect boundary.Defect image can be reconstructed by summing gray value of all pixels in the image area.The experimentally reconstructed defect image shows that the new tomography algorithm based on Hilbert transformation is efficient for defect detection in metal plate.展开更多
Strengthened directivity with higher-order side lobes can be generated by the transducer with a larger radius at a higher frequency. The multi-annular pressure distributions are displayed in the cross-section of the a...Strengthened directivity with higher-order side lobes can be generated by the transducer with a larger radius at a higher frequency. The multi-annular pressure distributions are displayed in the cross-section of the acoustic vortices(AVs)which are formed by side lobes. In the near field, particles can be trapped in the valley region between the two annuli of the pressure peak, and cannot be moved to the vortex center. In this paper, a trapping method based on a sector transducer array is proposed, which is characterized by the continuously variable topological charge(CVTC). This acoustic field can not only enlarge the range of particle trapping but also improve the aggregation degree of the trapped particles. In the experiments, polyethylene particles with a diameter of 0.2 mm are trapped into the multi-annular valleys by the AV with a fixed topological charge. Nevertheless, by applying the CVTC, particles outside the radius of the AV can cross the pressure peak successfully and move to the vortex center. Theoretical studies are also verified by the experimental particles trapping using the AV with the continuous variation of three topological charges, and suggest the potential application of large-scale particle trapping in biomedical engineering.展开更多
The basic principle and features of ultrasonic phased array imaging are discussed in this paper. Through the ultrasonic phased array technology, the electron beam welding defects and frozen keyholes characterization a...The basic principle and features of ultrasonic phased array imaging are discussed in this paper. Through the ultrasonic phased array technology, the electron beam welding defects and frozen keyholes characterization and imaging were realized. The ultrasonic phased array technology can detect kinds of defects in electron beam welding (EBW) quickly and easily.展开更多
As a hybrid imaging modality that combines optical excitation with acoustic detection,photoacoustic tomography(PAT)has become one of the fastest growing biomedical imaging modalities.Among various types of transducer ...As a hybrid imaging modality that combines optical excitation with acoustic detection,photoacoustic tomography(PAT)has become one of the fastest growing biomedical imaging modalities.Among various types of transducer arrays used in a PAT system conguration,the linear array is the most commonly utilized due to its convenience and low-cost.Although linear array-based PAT has been quickly developed within the recent decade,there are still two major challenges that impair the overall performance of the PAT imaging system.Therst challenge is that the three-dimensional(3D)imaging capability of a linear array is limited due to its poor elevational resolution.The other challenge is that the geometrical shape of the linear array constrains light illumination.To date,substantial e®orts have been made to address the aforementioned challenges.This review will present current technologies for improving the elevation resolution and light delivery of linear array-based PAT systems.展开更多
Most high frequency(>15MHz)medical ultrasound systems are based on single element transducers mechanically scanned.These systems can provide images with excellent resolution.However,single element transducers are o...Most high frequency(>15MHz)medical ultrasound systems are based on single element transducers mechanically scanned.These systems can provide images with excellent resolution.However,single element transducers are often limited by the fixed focal point and small depth of field.Annular arrays consisting of concentric rings of elements are focused electronically.These arrays are desirable to avoid the fixed focal point of the single element transducers and improve the depth of field.This paper reports the design,fabrication,and characterization of a 5-element equal-area annular array transducer.After electrical impedance matching,the average center frequency was 20MHz and-6 dB bandwidths ranged from 34 to 42%.The ILs for the matched annuli ranged from 6.1 to 26.5 dB.展开更多
A simple algorithm using an impulse response for a rectangular piston element is discussed. The impulse response of linear phased array is obtained hv stumming the impulse responses of rectangular piston elements with...A simple algorithm using an impulse response for a rectangular piston element is discussed. The impulse response of linear phased array is obtained hv stumming the impulse responses of rectangular piston elements with different delay times. The output response of the linear wide-band array is equal to the convolution of impulse response functions with wide-band pulse exeiting signal. Sound field distributions and impulse responses of three kinds of transducers are compared. The results can be used to optimize the parameters of the linear phased array transducers used in uhrasonie imaging in nondestructive testing (NDT).展开更多
A novel automatic ultrasonic system used for the inspection of pipeline girth welds is developed, in which a linear phased array transducer using electronic scan is adopted. Optimal array parameters are determined bas...A novel automatic ultrasonic system used for the inspection of pipeline girth welds is developed, in which a linear phased array transducer using electronic scan is adopted. Optimal array parameters are determined based on a mathematical model of acoustic field for linear phased army derived from Huygens' principle. The testing method and the system structure are introduced. The experimental results show that the phased array transducer system has the same detectability as that of conventional ultrasonic transducer system, but the system architecture can be simplified greatly, and the testing flexibility and the testing speed can be improved greatly.展开更多
Ultrasound imaging is the most widely used noninvasive medical imaging modality. Its latest elite concept is Superharmonic Imaging which is the most talked-about future of medical diagnostic ultrasound. In this paper,...Ultrasound imaging is the most widely used noninvasive medical imaging modality. Its latest elite concept is Superharmonic Imaging which is the most talked-about future of medical diagnostic ultrasound. In this paper, the computational and analytical study for superharmonic field generation from phased array transducer of 16 × 16 elements is presented. For this, the model preferred, includes the calculation for diffraction effect in frequency domain and nonlinear effect in time domain. The attenuation is included along with the diffraction in frequency domain as well. The comparative analysis of superharmonic field is also carried out with simulated fundamental and second harmonic fields by the same model. Similarly, the comparison with the results from the literature is also reported.展开更多
We develop a fast microwave-induced thermoacoustic tomography system based on a 320-element phase-controlled focus linear transducer array. A 1.2-GHz microwave generator transmits microwave with a pulse width of 0.5 ...We develop a fast microwave-induced thermoacoustic tomography system based on a 320-element phase-controlled focus linear transducer array. A 1.2-GHz microwave generator transmits microwave with a pulse width of 0.5 μs and an incident energy density of 0. 45 mJ/cm^2, and the microwave energy is delivered by a rectangular waveguide with a cross section of (80.01 ± 0.02) × 10^-4 m^2. Compared to single transducer collection, the system with the multi-element linear transducer array can eliminate the mechanical rotation of the transducer, hence can effectively reduce the image blurring and improve the image resolution. Using a phase-controlled focus technique to collect thermoacoustic signals, the data need not be averaged because of a high signal-to-noise ratio, resulting in a total data acquisition time of less than 5 s. The system thus provides a rapid and reliable approach to thermoacoustic imaging, which can potentially be developed as a powerful diagnostic tool for early-stage breast caners.展开更多
This paper presents a new focusing and scanning method which focuses multiple waves on a target. The key of the method is to control excitation pulses for each element of the transducer array. The excitation pulse on ...This paper presents a new focusing and scanning method which focuses multiple waves on a target. The key of the method is to control excitation pulses for each element of the transducer array. The excitation pulse on each array element is obtained by time reversing the signal received by the same element, which is generated by an imaginary source at the target. The excitation pulses from all array elements are transmitted and arrive at the target simultaneously, and focusing is achieved. The performance of the two methods is compared in numerical examples, and it is demonstrated that the proposed method achieves a satisfactory focusing and a good signal-to-noise ratio no matter where the target location is.展开更多
Developing new imaging methods needs to establish some proofs of concept before implementing them on real-time scenarios. Nowadays, the high computational power reached by multi-core CPUs and GPUs have driven the deve...Developing new imaging methods needs to establish some proofs of concept before implementing them on real-time scenarios. Nowadays, the high computational power reached by multi-core CPUs and GPUs have driven the development of software-based beamformers. Taking this into account, a library for the fast generation of ultrasound images is presented. It is based on Synthetic Aperture Imaging Techniques (SAFT) and it is fast because of the use of parallel computing techniques. Any kind of transducers as well as SAFT techniques can be defined although it includes some pre-built SAFT methods like 2R-SAFT and TFM. Furthermore, 2D and 3D imaging (slice- based or full volume computation) is supported along with the ability to generate both rectangular and angular images. For interpolation, linear and polynomial schemes can be chosen. The versatility of the library is ensured by interfacing it to Matlab, Python and any programming language over different operating systems. On a standard PC equipped with a single NVIDIA Quadro 4000 (256 cores), the library is able to calculate 262,144 pixels in ≈105 ms using a linear transducer with 64 elements, and 2,097,152 voxels in ≈ 5 seconds using a matrix transducer with 121 elements when TFM is applied.展开更多
The mechanical characterization of a 4×4 air-coupled array of Piezoelectric Micromachined Ultrasonic Transducers(PMUTs)is pre-sented.The experimental campaign consists of three set of experi-mental tests,namely:t...The mechanical characterization of a 4×4 air-coupled array of Piezoelectric Micromachined Ultrasonic Transducers(PMUTs)is pre-sented.The experimental campaign consists of three set of experi-mental tests,namely:topography measurements,small signal dynamic measurements,and vibrometry in the non-linear dynamic regime.The behavior of three different kinds of PMUT are reported.They differ according to the thermo-electrical treatment that has been applied to the piezoelectric material.The presence of the fabrication induced residual stresses is investigated and the treat-ment effect is evaluated in terms of the initial deflected configura-tion.The results reported in this paper represent an experimental mechanical investigation useful for the design of PMUT structures with advanced functionalities in the linear and non-linear regime.展开更多
Two kinds of measurement errors have been observed in the recently developed UAT-2 ultrasonic anemometer.One is the flow distortion produced by a"blocking effect",and the other is the angle of attack caused ...Two kinds of measurement errors have been observed in the recently developed UAT-2 ultrasonic anemometer.One is the flow distortion produced by a"blocking effect",and the other is the angle of attack caused by the vertical misalignment of the instrument.Here,we study these errors and discuss the possible correction methods.Via a wind tunnel experiment and numerical simulation,a 3D calibration matrix was developed to correct the"blocking effect".In the field test,the angle of attack was detected by an inclinometer settled on the reference plane of the anemometer,and the instrumental misalignment or tilt was corrected by a coordinate transformation.The combined use of an inclinometer and the proposed correction method may help find a new approach for vertical velocity correction.展开更多
基金Project supported by the Natural Science Foundation of Shandong Province, China (Grant Nos. ZR2022MF336 and ZR2022MD036)。
文摘The characteristics of traditional acoustic vortices(AVs) were verified by the cross-sectional axisymmetric pressure distributions with perfect phase spirals around the center pressure null. In order to generate a non-axisymmetric pressure distribution, the concept of power-exponent-phase was first introduced into the formation of AV beams, named “powerexponent-phase acoustic vortices(PAVs)” in this paper. Based on a ring-array of sector transducers, the helical distribution of the low-pressure valley in cross-sections of PAVs, which enables particles to move from a distant position to the center low-potential well along a certain spiral passageway, was proved theoretically. The particle manipulation behavior for PAVs with a power order of 2 is numerically modeled and experimentally confirmed. The results show that PAVs with a nonaxisymmetric spiral pressure distribution can be used to realize the directional transport of particles in an enlarged scope,suggesting prospective application potential in biomedical engineering.
基金Supported by National Natural Science Foundation of China(Grant No.51375217)
文摘Cracks, especially small cracks are di cult to be detected in oil and gas transportation pipelines buried underground or covered with layers of material by using the traditional ultrasonic inspection techniques. Therefore, a new com?posite ultrasonic transducer array with three acoustic beam incidence modes is developed. The space model of the array is also established to obtain the defect reflection point location. And the crack ultrasound image is thus formed through a series of small cubical elements expanded around the point locations by using the projection of binariza?tion values extracted from the received ultrasonic echo signals. Laboratory experiments are performed on a pipeline sample with di erent types of cracks to verify the e ectiveness and performance of the proposed technique. From the image, the presence of small cracks can be clearly observed, in addition to the sizes and orientations of the cracks. The proposed technique can not only inspect common flaws, but also detect cracks with various orientations, which is helpful for defect evaluation in pipeline testing.
基金the National Key R&D Program of China(Nos.2017YFA0205103 and 2018YFE020505)the National Natural Science Foundation of China(Nos.81571766 and 61771337)+1 种基金the Natural Science Foundation of Tianjin,China(No.17JCYBJC24400)the“111”Project of China(No.B07014).
文摘An air parametric array can generate a highly directional beam of audible sound in air,which has a wide range of applications in targeted audio delivery.Capacitive micromachined ultrasonic transducer(CMUTs)have great potential for air-coupled applications,mainly because of their low acoustic impedance.In this study,an air-coupled CMUT array is designed as an air parametric array.A hexagonal array is proposed to improve the directivity of the sound generated.A finite element model of the CMUT is established in COMSOL software to facilitate the choice of appropriate structural parameters of the CMUT cell.The CMUT array is then fabricated by a wafer bonding process with high consistency.The performances of the CMUT are tested to verify the accuracy of the finite element analysis.By optimizing the component parameters of the bias-T circuit used for driving the CMUT,DC and AC voltages can be effectively applied to the top and bottom electrodes of the CMUT to provide efficient ultrasound transmission.Finally,the prepared hexagonal array is successfully used to conduct preliminary experiments on its application as an air parametric array.
基金Supported by the National Natural Science Foundation of China(50975028)"111"Project of China(B08043)
文摘Hilbert transformation and improved ellipse localization method is applied in ultrasonic transducer array tomography to detect defect of metal plate.By combining the improved ellipse localization method and time-reversal method,the new ultrasonic tomography algorithm employs smooth Hilbert envelope instead of discrete amplitude to reconstruct defect image.An ultrasonic tomography system with six transducers is built to evaluate the effectiveness of the new ultrasonic tomography algorithm.The S0 mode Lamb wave is excited on special condition,and the mode of received signal is identified by Vigner-Wille distribution.The gray value of image area is defined by envelope of the reflected S0 mode Lamb wave signal from defect boundary.Defect image can be reconstructed by summing gray value of all pixels in the image area.The experimentally reconstructed defect image shows that the new tomography algorithm based on Hilbert transformation is efficient for defect detection in metal plate.
基金Project supported by the National Key R&D Program of China(Grant No.2023YFE0201900)。
文摘Strengthened directivity with higher-order side lobes can be generated by the transducer with a larger radius at a higher frequency. The multi-annular pressure distributions are displayed in the cross-section of the acoustic vortices(AVs)which are formed by side lobes. In the near field, particles can be trapped in the valley region between the two annuli of the pressure peak, and cannot be moved to the vortex center. In this paper, a trapping method based on a sector transducer array is proposed, which is characterized by the continuously variable topological charge(CVTC). This acoustic field can not only enlarge the range of particle trapping but also improve the aggregation degree of the trapped particles. In the experiments, polyethylene particles with a diameter of 0.2 mm are trapped into the multi-annular valleys by the AV with a fixed topological charge. Nevertheless, by applying the CVTC, particles outside the radius of the AV can cross the pressure peak successfully and move to the vortex center. Theoretical studies are also verified by the experimental particles trapping using the AV with the continuous variation of three topological charges, and suggest the potential application of large-scale particle trapping in biomedical engineering.
文摘The basic principle and features of ultrasonic phased array imaging are discussed in this paper. Through the ultrasonic phased array technology, the electron beam welding defects and frozen keyholes characterization and imaging were realized. The ultrasonic phased array technology can detect kinds of defects in electron beam welding (EBW) quickly and easily.
基金supported in part by the Career Catalyst Research Grant from the Susan G.Komen Foundation(No.CCR17481211).
文摘As a hybrid imaging modality that combines optical excitation with acoustic detection,photoacoustic tomography(PAT)has become one of the fastest growing biomedical imaging modalities.Among various types of transducer arrays used in a PAT system conguration,the linear array is the most commonly utilized due to its convenience and low-cost.Although linear array-based PAT has been quickly developed within the recent decade,there are still two major challenges that impair the overall performance of the PAT imaging system.Therst challenge is that the three-dimensional(3D)imaging capability of a linear array is limited due to its poor elevational resolution.The other challenge is that the geometrical shape of the linear array constrains light illumination.To date,substantial e®orts have been made to address the aforementioned challenges.This review will present current technologies for improving the elevation resolution and light delivery of linear array-based PAT systems.
基金This work was supported by the National Natural Science Foundation of China(Grant Nos.10904093 and 61031003)the Science and Technology Grant Scheme funds from Shenzhen Government(No.08CXY-23).
文摘Most high frequency(>15MHz)medical ultrasound systems are based on single element transducers mechanically scanned.These systems can provide images with excellent resolution.However,single element transducers are often limited by the fixed focal point and small depth of field.Annular arrays consisting of concentric rings of elements are focused electronically.These arrays are desirable to avoid the fixed focal point of the single element transducers and improve the depth of field.This paper reports the design,fabrication,and characterization of a 5-element equal-area annular array transducer.After electrical impedance matching,the average center frequency was 20MHz and-6 dB bandwidths ranged from 34 to 42%.The ILs for the matched annuli ranged from 6.1 to 26.5 dB.
基金Sponsored by the Foundation of High Technology Research and Development Program of China (Grant No. 2001AA616170).
文摘A simple algorithm using an impulse response for a rectangular piston element is discussed. The impulse response of linear phased array is obtained hv stumming the impulse responses of rectangular piston elements with different delay times. The output response of the linear wide-band array is equal to the convolution of impulse response functions with wide-band pulse exeiting signal. Sound field distributions and impulse responses of three kinds of transducers are compared. The results can be used to optimize the parameters of the linear phased array transducers used in uhrasonie imaging in nondestructive testing (NDT).
文摘A novel automatic ultrasonic system used for the inspection of pipeline girth welds is developed, in which a linear phased array transducer using electronic scan is adopted. Optimal array parameters are determined based on a mathematical model of acoustic field for linear phased army derived from Huygens' principle. The testing method and the system structure are introduced. The experimental results show that the phased array transducer system has the same detectability as that of conventional ultrasonic transducer system, but the system architecture can be simplified greatly, and the testing flexibility and the testing speed can be improved greatly.
文摘Ultrasound imaging is the most widely used noninvasive medical imaging modality. Its latest elite concept is Superharmonic Imaging which is the most talked-about future of medical diagnostic ultrasound. In this paper, the computational and analytical study for superharmonic field generation from phased array transducer of 16 × 16 elements is presented. For this, the model preferred, includes the calculation for diffraction effect in frequency domain and nonlinear effect in time domain. The attenuation is included along with the diffraction in frequency domain as well. The comparative analysis of superharmonic field is also carried out with simulated fundamental and second harmonic fields by the same model. Similarly, the comparison with the results from the literature is also reported.
基金Supported by the National Natural Science Foundation of China under Grant Nos 60378043 and 30470494, and the Natural Science Foundation of Guangdong Province (015012 04010394 2004B10401011).
文摘We develop a fast microwave-induced thermoacoustic tomography system based on a 320-element phase-controlled focus linear transducer array. A 1.2-GHz microwave generator transmits microwave with a pulse width of 0.5 μs and an incident energy density of 0. 45 mJ/cm^2, and the microwave energy is delivered by a rectangular waveguide with a cross section of (80.01 ± 0.02) × 10^-4 m^2. Compared to single transducer collection, the system with the multi-element linear transducer array can eliminate the mechanical rotation of the transducer, hence can effectively reduce the image blurring and improve the image resolution. Using a phase-controlled focus technique to collect thermoacoustic signals, the data need not be averaged because of a high signal-to-noise ratio, resulting in a total data acquisition time of less than 5 s. The system thus provides a rapid and reliable approach to thermoacoustic imaging, which can potentially be developed as a powerful diagnostic tool for early-stage breast caners.
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 11174322 and 11074273)the Research Council of Norway (GrantNo. 186923/I30)
文摘This paper presents a new focusing and scanning method which focuses multiple waves on a target. The key of the method is to control excitation pulses for each element of the transducer array. The excitation pulse on each array element is obtained by time reversing the signal received by the same element, which is generated by an imaginary source at the target. The excitation pulses from all array elements are transmitted and arrive at the target simultaneously, and focusing is achieved. The performance of the two methods is compared in numerical examples, and it is demonstrated that the proposed method achieves a satisfactory focusing and a good signal-to-noise ratio no matter where the target location is.
基金supported by the Spanish Government and the University of Alcaláunder projects DPI2010-19376 and CCG2014/EXP-084,respectively.
文摘Developing new imaging methods needs to establish some proofs of concept before implementing them on real-time scenarios. Nowadays, the high computational power reached by multi-core CPUs and GPUs have driven the development of software-based beamformers. Taking this into account, a library for the fast generation of ultrasound images is presented. It is based on Synthetic Aperture Imaging Techniques (SAFT) and it is fast because of the use of parallel computing techniques. Any kind of transducers as well as SAFT techniques can be defined although it includes some pre-built SAFT methods like 2R-SAFT and TFM. Furthermore, 2D and 3D imaging (slice- based or full volume computation) is supported along with the ability to generate both rectangular and angular images. For interpolation, linear and polynomial schemes can be chosen. The versatility of the library is ensured by interfacing it to Matlab, Python and any programming language over different operating systems. On a standard PC equipped with a single NVIDIA Quadro 4000 (256 cores), the library is able to calculate 262,144 pixels in ≈105 ms using a linear transducer with 64 elements, and 2,097,152 voxels in ≈ 5 seconds using a matrix transducer with 121 elements when TFM is applied.
基金This work was supported by the ECSEL JOINT UNDERTAKING[826452].
文摘The mechanical characterization of a 4×4 air-coupled array of Piezoelectric Micromachined Ultrasonic Transducers(PMUTs)is pre-sented.The experimental campaign consists of three set of experi-mental tests,namely:topography measurements,small signal dynamic measurements,and vibrometry in the non-linear dynamic regime.The behavior of three different kinds of PMUT are reported.They differ according to the thermo-electrical treatment that has been applied to the piezoelectric material.The presence of the fabrication induced residual stresses is investigated and the treat-ment effect is evaluated in terms of the initial deflected configura-tion.The results reported in this paper represent an experimental mechanical investigation useful for the design of PMUT structures with advanced functionalities in the linear and non-linear regime.
基金The National Basic Research Program of China(Grant No.2010CB951804)The Strategy Guide for the Specific Task of the Chinese Academy of Sciences(Grant No.XDA10010403)+2 种基金The National Natural Science Foundation of China(Grant No.41375018)Special finance from the China Meteorological Administration(Grant No.GYHY200706034)The National Science and Technology Pillar Program(Grant No.2008BAC37B02)
文摘Two kinds of measurement errors have been observed in the recently developed UAT-2 ultrasonic anemometer.One is the flow distortion produced by a"blocking effect",and the other is the angle of attack caused by the vertical misalignment of the instrument.Here,we study these errors and discuss the possible correction methods.Via a wind tunnel experiment and numerical simulation,a 3D calibration matrix was developed to correct the"blocking effect".In the field test,the angle of attack was detected by an inclinometer settled on the reference plane of the anemometer,and the instrumental misalignment or tilt was corrected by a coordinate transformation.The combined use of an inclinometer and the proposed correction method may help find a new approach for vertical velocity correction.