期刊文献+
共找到26,860篇文章
< 1 2 250 >
每页显示 20 50 100
Bio-Inspired Screwed Conduits from the Microfluidic Rope-Coiling Effect for Microvessels and Bronchioles
1
作者 Rui Liu Jiahui Guo +3 位作者 Bin Kong Yunru Yu Yuanjin Zhao Lingyun Sun 《Engineering》 SCIE EI CAS CSCD 2024年第10期172-178,共7页
Tubular microfibers have recently attracted extensive interest for applications in tissue engineering.However,the fabrication of tubular fibers with intricate hierarchical structures remains a major challenge.Here,we ... Tubular microfibers have recently attracted extensive interest for applications in tissue engineering.However,the fabrication of tubular fibers with intricate hierarchical structures remains a major challenge.Here,we present a novel one-step microfluidic spinning method to generate bio-inspired screwed conduits(BSCs).Based on the microfluidic rope-coiling effect,a viscous hydrogel precursor is first curved into a helix stream in the channel,and then consecutively packed as a hollow structured stream and gelated into a screwed conduit(SC)via ionic and covalent crosslinking.By taking advantage of the excellent fluid-controlling ability of microfluidics,various tubes with diverse structures are fabricated via simple control over fluid velocities and multiple microfluidic device designs.The perfusability and permeability results,as well as the encapsulation and culture of human umbilical vein endothelial cells(HUVECs),human pulmonary alveolar epithelial cells(HPAs),and myogenic cells(C2C12),demonstrate that these SCs have good perfusability and permeability and the ability to induce the formation of functional biostructures.These features support the uniqueness and potential applications of these BSCs as biomimetic blood vessels and bronchiole tissues in combination with tissue microstructures,with likely application possibilities in biomedical engineering. 展开更多
关键词 BIO-INSPIRED Microfluidics MICROFIBER Tissue engineering Bronchiole vessel
下载PDF
Experimental and numerical study of hypervelocity impact damage on composite overwrapped pressure vessels
2
作者 Yong-Pan Duan Run-Qiang Chi +1 位作者 Bao-Jun Pang Yuan Cai 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第1期58-72,共15页
Ground-based tests are important for studying hypervelocity impact(HVI)damage to spacecraft pressure vessels in the orbital debris environment.We analyzed the damage to composite overwrapped pressure vessels(COPVs)in ... Ground-based tests are important for studying hypervelocity impact(HVI)damage to spacecraft pressure vessels in the orbital debris environment.We analyzed the damage to composite overwrapped pressure vessels(COPVs)in the HVI tests and classified the damage into non-catastrophic damage and catastrophic damage.We proposed a numerical simulation method to further study non-catastrophic damage and revealed the characteristics and mechanisms of non-catastrophic damage affected by impact conditions and internal pressures.The fragments of the catastrophically damaged COPVs were collected after the tests.The crack distribution and propagation process of the catastrophic ruptures of the COPVs were analyzed.Our findings contribute to understanding the damage characteristics and mechanisms of COPVs by HVIs. 展开更多
关键词 Orbital debris Hypervelocity impact Composite overwrapped pressure vessels Damage mechanisms
下载PDF
Predictive visual field outcomes after optic chiasm decompressive surgery by retinal vessels parameters using optical coherence tomography angiography
3
作者 Wen-Juan Yu Jin Xiao +3 位作者 Guang-Xin Wang Chang Jiang Wei Zha Rong-Feng Liao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期365-373,共9页
AIM:To evaluate the predictive value of superficial retinal capillary plexus(SRCP)and radial peripapillary capillary(RPC)for visual field recovery after optic cross decompression and compare them with peripapillary ne... AIM:To evaluate the predictive value of superficial retinal capillary plexus(SRCP)and radial peripapillary capillary(RPC)for visual field recovery after optic cross decompression and compare them with peripapillary nerve fiber layer(pRNFL)and ganglion cell complex(GCC).METHODS:This prospective longitudinal observational study included patients with chiasmal compression due to sellar region mass scheduled for decompressive surgery.Generalized estimating equations were used to compare retinal vessel density and retinal layer thickness preand post-operatively and with healthy controls.Logistic regression models were used to assess the relationship between preoperative GCC,pRNFL,SRCP,and RPC parameters and visual field recovery after surgery.RESULTS:The study included 43 eyes of 24 patients and 48 eyes of 24 healthy controls.Preoperative RPC and SRCP vessel density and pRNFL and GCC thickness were lower than healthy controls and higher than postoperative values.The best predictive GCC and pRNFL models were based on the superior GCC[area under the curve(AUC)=0.866]and the tempo-inferior pRNFL(AUC=0.824),and the best predictive SRCP and RPC models were based on the nasal SRCP(AUC=0.718)and tempo-inferior RPC(AUC=0.825).There was no statistical difference in the predictive value of the superior GCC,tempo-inferior pRNFL,and tempo-inferior RPC(all P>0.05).CONCLUSION:Compression of the optic chiasm by tumors in the saddle area can reduce retinal thickness and blood perfusion.This reduction persists despite the recovery of the visual field after decompression surgery.GCC,pRNFL,and RPC can be used as sensitive predictors of visual field recovery after decompression surgery. 展开更多
关键词 sellar region mass retinal vessels optic chiasm optical coherence tomography angiography visual field decompressive surgery
下载PDF
Nomogram prediction of vessels encapsulating tumor clusters in small hepatocellular carcinoma≤3 cm based on enhanced magnetic resonance imaging
4
作者 Hui-Lin Chen Rui-Lin He +5 位作者 Meng-Ting Gu Xing-Yu Zhao Kai-Rong Song Wen-Jie Zou Ning-Yang Jia Wan-Min Liu 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第5期1808-1820,共13页
BACKGROUND Vessels encapsulating tumor clusters(VETC)represent a recently discovered vascular pattern associated with novel metastasis mechanisms in hepatocellular carcinoma(HCC).However,it seems that no one have focu... BACKGROUND Vessels encapsulating tumor clusters(VETC)represent a recently discovered vascular pattern associated with novel metastasis mechanisms in hepatocellular carcinoma(HCC).However,it seems that no one have focused on predicting VETC status in small HCC(sHCC).This study aimed to develop a new nomogram for predicting VETC positivity using preoperative clinical data and image features in sHCC(≤3 cm)patients.AIM To construct a nomogram that combines preoperative clinical parameters and image features to predict patterns of VETC and evaluate the prognosis of sHCC patients.METHODS A total of 309 patients with sHCC,who underwent segmental resection and had their VETC status confirmed,were included in the study.These patients were recruited from three different hospitals:Hospital 1 contributed 177 patients for the training set,Hospital 2 provided 78 patients for the test set,and Hospital 3 provided 54 patients for the validation set.Independent predictors of VETC were identified through univariate and multivariate logistic analyses.These independent predictors were then used to construct a VETC prediction model for sHCC.The model’s performance was evaluated using the area under the curve(AUC),calibration curve,and clinical decision curve.Additionally,Kaplan-Meier survival analysis was performed to confirm whether the predicted VETC status by the model is associated with early recurrence,just as it is with the actual VETC status and early recurrence.RESULTS Alpha-fetoprotein_lg10,carbohydrate antigen 199,irregular shape,non-smooth margin,and arterial peritumoral enhancement were identified as independent predictors of VETC.The model incorporating these predictors demonstrated strong predictive performance.The AUC was 0.811 for the training set,0.800 for the test set,and 0.791 for the validation set.The calibration curve indicated that the predicted probability was consistent with the actual VETC status in all three sets.Furthermore,the decision curve analysis demonstrated the clinical benefits of our model for patients with sHCC.Finally,early recurrence was more likely to occur in the VETC-positive group compared to the VETC-negative group,regardless of whether considering the actual or predicted VETC status.CONCLUSION Our novel prediction model demonstrates strong performance in predicting VETC positivity in sHCC(≤3 cm)patients,and it holds potential for predicting early recurrence.This model equips clinicians with valuable information to make informed clinical treatment decisions. 展开更多
关键词 Small hepatocellular carcinoma vessels encapsulating tumor clusters NOMOGRAM Magnetic resonance imaging MULTICENTER
下载PDF
Preoperatively predicting vessels encapsulating tumor clusters in hepatocellular carcinoma:Machine learning model based on contrast-enhanced computed tomography
5
作者 Chao Zhang Hai Zhong +3 位作者 Fang Zhao Zhen-Yu Ma Zheng-Jun Dai Guo-Dong Pang 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第3期857-874,共18页
BACKGROUND Recently,vessels encapsulating tumor clusters(VETC)was considered as a distinct pattern of tumor vascularization which can primarily facilitate the entry of the whole tumor cluster into the bloodstream in a... BACKGROUND Recently,vessels encapsulating tumor clusters(VETC)was considered as a distinct pattern of tumor vascularization which can primarily facilitate the entry of the whole tumor cluster into the bloodstream in an invasion independent manner,and was regarded as an independent risk factor for poor prognosis in hepatocellular carcinoma(HCC).AIM To develop and validate a preoperative nomogram using contrast-enhanced computed tomography(CECT)to predict the presence of VETC+in HCC.METHODS We retrospectively evaluated 190 patients with pathologically confirmed HCC who underwent CECT scanning and immunochemical staining for cluster of differentiation 34 at two medical centers.Radiomics analysis was conducted on intratumoral and peritumoral regions in the portal vein phase.Radiomics features,essential for identifying VETC+HCC,were extracted and utilized to develop a radiomics model using machine learning algorithms in the training set.The model’s performance was validated on two separate test sets.Receiver operating characteristic(ROC)analysis was employed to compare the identified performance of three models in predicting the VETC status of HCC on both training and test sets.The most predictive model was then used to constructed a radiomics nomogram that integrated the independent clinical-radiological features.ROC and decision curve analysis were used to assess the performance characteristics of the clinical-radiological features,the radiomics features and the radiomics nomogram.RESULTS The study included 190 individuals from two independent centers,with the majority being male(81%)and a median age of 57 years(interquartile range:51-66).The area under the curve(AUC)for the combined radiomics features selected from the intratumoral and peritumoral areas were 0.825,0.788,and 0.680 in the training set and the two test sets.A total of 13 features were selected to construct the Rad-score.The nomogram,combining clinicalradiological and combined radiomics features could accurately predict VETC+in all three sets,with AUC values of 0.859,0.848 and 0.757.Decision curve analysis revealed that the radiomics nomogram was more clinically useful than both the clinical-radiological feature and the combined radiomics models.CONCLUSION This study demonstrates the potential utility of a CECT-based radiomics nomogram,incorporating clinicalradiological features and combined radiomics features,in the identification of VETC+HCC. 展开更多
关键词 Hepatocellular carcinoma vessels encapsulating tumor clusters Intratumoral and peritumoral regions Radiomics features Nomog
下载PDF
Reduction of photodynamic damage of blood vessels in the protected region by(–)-epigallocatechin gallate
6
作者 Tianlong Chen Yi Shen +4 位作者 Li Lin Huiyun Lin Xuejiao Song Defu Chen Buhong Li 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第3期93-104,共12页
Photodynamic therapy(PDT)has been increasingly used in the clinical treatment of neoplastic,inflammatory and infectious skin diseases.However,the generation of reactive oxygen species(ROS)may induce undesired side eff... Photodynamic therapy(PDT)has been increasingly used in the clinical treatment of neoplastic,inflammatory and infectious skin diseases.However,the generation of reactive oxygen species(ROS)may induce undesired side effects in normal tissue surrounding the treatment lesion,which is a big challenge for the clinical application of PDT.To date,(–)-Epigallocatechin gallate(EGCG)has been widely proposed as an antiangiogenic and antitumor agent for the protection of normal tissue from ROS-mediated oxidative damage.This study evaluates the regulation ability of EGCG for photodynamic damage of blood vessels during hematoporphyrin monomethyl ether(Hemoporfin)-mediated PDT.The quenching rate constants of EGCG for the triplet-state Hemoporfin and photosensitized 1O2 generation are determined to be 6.8×10^(8)M^(−1)S^(−1),respectively.The vasoconstriction of blood vessels in the protected region treated with EGCG hydrogel after PDT is lower than that of the control region treated with pure hydrogel,suggesting an efficiently reduced photodamage of Hemoporfin for blood vessels treated with EGCG.This study indicates that EGCG is an efficient quencher for triplet-state Hemoporfin and 1O2,and EGCG could be potentially used to reduce the undesired photodamage of normal tissue in clinical PDT. 展开更多
关键词 (–)-Epigallocatechin gallate(EGCG) photodynamic therapy hemopor¯n singlet oxygen blood vessel vasoconstriction.
下载PDF
Application of a Newly Built Semi-submersible Vessel for Transportation of a Tension Leg Platform 被引量:1
7
作者 Dagang Zhang WeiyingSun Zhixia Fan 《Journal of Marine Science and Application》 2012年第3期341-350,共10页
Transportation of tension leg platform (TLP) structures for a long distance has always been associated with the use of a heavy semi-transport vessel. The requirements of this type of vessel are always special, and t... Transportation of tension leg platform (TLP) structures for a long distance has always been associated with the use of a heavy semi-transport vessel. The requirements of this type of vessel are always special, and their availability is limited. To prepare for the future development of South China Sea deepwater projects, the China Offshore Oil Engineering Corporation has recently built a heavy lift transport vessel-Hai Yang Shi You 278. This semi-submersible vessel has a displacement capacity of 50k DWT, and a breath of 42 meters. Understanding the vessel's applicability and preparing it for use in future deepwater projects are becoming imminent needs. This paper reviews the current critical issues associated with TLP transportation and performs detailed analysis of the designed TLP during load-out and transportation. The newly built COOEC transportation vessel HYSY 278 was applied to dry transport of the TLP structure from the COOEC fabrication yard in Qingdao to an oil field in South China Sea. The entire process included the load-out of the TLP structure from the landsite of the fabrication yard, the offloading and float-on of the platform from the vessel, the dry transport of the TLP over a long distance, and the final offloading of the platform. Both hydrodynamic and structure analysis were performed to evaluate the behavior of the transport vessel and TLP structure. Special attention was paid to critical areas associated with the use of this new vessel, along with any potential limitations. The results demonstrate that HYSY 278 can effectively be used for transporting the structure with proper arrangement and well-prepared operation. The procedure and details were presented on the basis of the study results. Special attention was also given to discussion on future use based on the results from the analysis. 展开更多
关键词 dry transport HYSY 278 tension leg platform (TLP) structure heavy semi-submersible transportvessel floating structure
下载PDF
Analysis of the Effect of Supplying Vessel on Wave Drift Force of Semi-Submersible Platform 被引量:1
8
作者 Chi Zhang Baoji Zhang 《Open Journal of Modelling and Simulation》 2019年第3期169-176,共8页
Wave drift force is the key factor affecting the mooring ability of semi-submersible platform. Aiming at the mooring system composed of replenishment ship and semi-submersible platform, the influence of hydrodynamic i... Wave drift force is the key factor affecting the mooring ability of semi-submersible platform. Aiming at the mooring system composed of replenishment ship and semi-submersible platform, the influence of hydrodynamic interference on semi-submersible platform is analyzed. Based on the three-dimensional potential flow theory and AQWA software, the effects of different wave directions and spacing on the wave drift force of semi-submersible platform are considered. The results show that the hydrodynamic interference of the replenishment ship will affect the wave drift force of the semi-submersible platform, and the influence of the distance between adjacent vessels and the wave direction angle is more sensitive in the middle and high wave frequencies. This paper can provide support for the research of hydrodynamic interference of semi-submersible platform. 展开更多
关键词 semi-submersible AQWA WAVE DRIFT FORCE Potential THEORY
下载PDF
Exploration on the Optimization Strategy for the Layup of Composite Material Pressure Vessels Based on Advanced Algorithms
9
作者 Qingshan Zeng Zuxin Chen 《Open Journal of Applied Sciences》 2024年第9期2482-2505,共24页
This study aims to explore the influence of the laying angle on the pressure shell structure made of composite materials under the condition of a fixed shape. By using a composite material composed of a mixture of T80... This study aims to explore the influence of the laying angle on the pressure shell structure made of composite materials under the condition of a fixed shape. By using a composite material composed of a mixture of T800 carbon fiber and AG80 epoxy resin to design pressure vessels, this material combination can significantly improve the interlaminar shear strength and heat resistance. The article elaborates on the basic concepts and failure criteria of composite materials, such as the maximum stress criterion, the maximum strain criterion, the Tsai-Hill criterion, etc. With the help of the APDL parametric modeling language, the arc-shaped, parabolic, elliptical, and fitting curve-shaped pressure vessel models are accurately constructed, and the material property settings and mesh division are completed. Subsequently, APDL is used for static analysis, and the genetic algorithm toolbox built into Matlab is combined to carry out optimization calculations to determine the optimal laying angle. The research results show that the equivalent stress corresponding to the optimal laying angle of the arc-shaped pressure vessel is 5.3685e+08 Pa, the elliptical one is 5.1969e+08 Pa, the parabolic one is 5.8692e+08 Pa, and the fitting curve-shaped one is 5.36862e+08 Pa. Among them, the stress distribution of the fitting curve-shaped pressure vessel is relatively more uniform, with a deformation of 0.568E−03 m, a minimum equivalent stress value of 0.261E+09 Pa, a maximum equivalent stress value of 0.537E+09 Pa, and a ratio of 0.48, which conforms to the equivalent stress criterion. In addition, the fitting curve of this model can adapt to various models and has higher practical value. However, the stress distribution of the elliptical and parabolic pressure vessels is uneven, and their applicability is poor. In the future, further exploration can be conducted on the application of the fitting curve model in composite materials to optimize the design of pressure vessels. This study provides important theoretical support and practical guidance for the design of composite material pressure vessels. 展开更多
关键词 Composite Material Pressure vessel Matlab APDL Parametric Modeling Static Analysis Optimal Laying Angle
下载PDF
Meningeal lymphatic vessel crosstalk with central nervous system immune cells in aging and neurodegenerative diseases
10
作者 Minghuang Gao Xinyue Wang +5 位作者 Shijie Su Weicheng Feng Yaona Lai Kongli Huang Dandan Cao Qi Wang 《Neural Regeneration Research》 SCIE CAS 2025年第3期763-778,共16页
Meningeal lymphatic vessels form a relationship between the nervous system and periphery, which is relevant in both health and disease. Meningeal lymphatic vessels not only play a key role in the drainage of brain met... Meningeal lymphatic vessels form a relationship between the nervous system and periphery, which is relevant in both health and disease. Meningeal lymphatic vessels not only play a key role in the drainage of brain metabolites but also contribute to antigen delivery and immune cell activation. The advent of novel genomic technologies has enabled rapid progress in the characterization of myeloid and lymphoid cells and their interactions with meningeal lymphatic vessels within the central nervous system. In this review, we provide an overview of the multifaceted roles of meningeal lymphatic vessels within the context of the central nervous system immune network, highlighting recent discoveries on the immunological niche provided by meningeal lymphatic vessels. Furthermore, we delve into the mechanisms of crosstalk between meningeal lymphatic vessels and immune cells in the central nervous system under both homeostatic conditions and neurodegenerative diseases, discussing how these interactions shape the pathological outcomes. Regulation of meningeal lymphatic vessel function and structure can influence lymphatic drainage, cerebrospinal fluid-borne immune modulators, and immune cell populations in aging and neurodegenerative disorders, thereby playing a key role in shaping meningeal and brain parenchyma immunity. 展开更多
关键词 central nervous system meningeal lymphatic vessels IMMUNITY myeloid cells lymphatic cells neurodegenerative disease
下载PDF
Studies on the Molecular Structure of Vessels in Secondary Xylem of Stem from Three Carambola Varieties 被引量:2
11
作者 陈燕 袁长春 陈小婷 《Agricultural Science & Technology》 CAS 2008年第4期99-103,156,共6页
[Objective] The aim of this study was to provide the theoretical basis for variety identification of carambola and pomiculture.[Method] The molecular structure of vessels in stem secondary xylem from three carambola v... [Objective] The aim of this study was to provide the theoretical basis for variety identification of carambola and pomiculture.[Method] The molecular structure of vessels in stem secondary xylem from three carambola varieties of Malaysia 8,Misi and Malaysia B17 were studied by cell image analysis system and microphotography.[Result] The molecular structure of vessels in stem secondary xylem from carambola was as follows:the first type had tails in two ends,the second type had tail in one end,and the third type had no tails in two ends.The average length of vessel elements was from 328.88 to 366.09 μm,while its average width was from 44.61 to 52.43 μm.Most of the end wall was simple perforation plates,while the alternate-opposite pitting was the major forms of pitting.[Conclusion] Most characteristics of vessel elements from carambola were evolutionary characters of vessel elements in the process of phylogeny,but there were more primitive characters,for example,both two ends of vessel had tails or just one end had tail,and end wall was inclined.The molecular structure of vessel from carambola was in accordance with its ecological adaptability,and the growth characteristics of different varieties were also in accordance with the difference of molecular structure of vessel. 展开更多
关键词 CARAMBOLA vessel elements Microstructure
下载PDF
Study on the general layout of semi-submersible offshore drilling platforms based on process flow 被引量:2
12
作者 岳吉祥 綦耀光 +2 位作者 肖文生 杨磊 杨轶普 《Journal of Marine Science and Application》 2009年第2期117-122,共6页
The general layout of 6th generation semi-submersible drilling platforms is the main factor impacting the efficiency of their drilling operations. This paper provides a compound/integrated algorithm based on process f... The general layout of 6th generation semi-submersible drilling platforms is the main factor impacting the efficiency of their drilling operations. This paper provides a compound/integrated algorithm based on process flow that is aimed at improving efficiency, while giving attention to stability and safety at the same time. The paper describes the process flow of dual drilling centers and a hierarchical division of rigs based on the different modes of transportation of various drilling support systems. The general layout-centripetal overall arrangement spatially was determined based on drilling efficiency. We derived our modules according to drilling functionality; the modules became our basic layout units. We applied different layout algorithm to mark out the upper and lower decks. That is, the upper deck was designed based on the lowest transportation cost while the lower deck's calculations were based on the best-fit scope. Storage configurations in columns and pontoons were also considered for the layout design. Finally the center of gravity was taken into consideration and the general layout was adjusted accordingly, to result in an optimal center of gravity. The methodology of the general layout can provide a reference for implementation of domestic designs of semi-submersible rigs. 展开更多
关键词 semi-submersible drilling platform general layout drilling process flow layout optimization group technology
下载PDF
Choke Vessels扩展的研究进展 被引量:1
13
作者 蒙旭昌 昝涛 李青峰 《组织工程与重建外科杂志》 2017年第1期48-50,共3页
穿支皮瓣是创伤修复的研究热点,穿支皮瓣研究的重点和难点则在于choke vessels。我们对近年来choke vessels扩展研究的相关文献进行综述,目前的研究主要聚焦于形态学的描述,其扩张机制很可能是剪切力变化,激活TRPV4,通过NF-kb通路而导致... 穿支皮瓣是创伤修复的研究热点,穿支皮瓣研究的重点和难点则在于choke vessels。我们对近年来choke vessels扩展研究的相关文献进行综述,目前的研究主要聚焦于形态学的描述,其扩张机制很可能是剪切力变化,激活TRPV4,通过NF-kb通路而导致choke vessels扩张。 展开更多
关键词 CHOKE vessels 穿支皮瓣 动脉生成 扩展
下载PDF
穿支皮瓣choke vessels新生的研究进展 被引量:6
14
作者 李红 陈世新 +1 位作者 唐茂林 毛以华 《中国临床解剖学杂志》 CSCD 北大核心 2016年第6期711-712,715,共3页
大量研究资料显示:每一皮肤穿支均有一个明确的供血范围,并与周围其它穿支的分支相互吻合形成血管网,即choke vessels。作为血管体间桥梁结构的choke vessels在跨区皮瓣的设计和切取方面起到十分重要的作用。近年来,有关穿支皮瓣跨区... 大量研究资料显示:每一皮肤穿支均有一个明确的供血范围,并与周围其它穿支的分支相互吻合形成血管网,即choke vessels。作为血管体间桥梁结构的choke vessels在跨区皮瓣的设计和切取方面起到十分重要的作用。近年来,有关穿支皮瓣跨区供血的基础研究-[1-3]和临床报道-[4-6]屡见不鲜,而本文就其中与choke vessels新生相关的研究综述如下。 展开更多
关键词 穿支皮瓣 CHOKE vessels 血管网 血管发生 桥梁结构 供区 动脉灌注 静脉回流 血管内皮细胞 血缺氧
下载PDF
Choke vessels与穿支皮瓣的扩展 被引量:16
15
作者 毛以华 唐茂林 《中国临床解剖学杂志》 CSCD 北大核心 2010年第2期228-230,共3页
近年来随着临床解剖学研究的深入,在皮瓣的血供研究方面取得了新进展。1987年,Taylor等[1]提出了"血管体(angiosomes)"理论,所谓血管体是指某一源动脉呈树形分布的所有解剖学区域(anatomical territory),包括皮肤、浅筋膜、深筋... 近年来随着临床解剖学研究的深入,在皮瓣的血供研究方面取得了新进展。1987年,Taylor等[1]提出了"血管体(angiosomes)"理论,所谓血管体是指某一源动脉呈树形分布的所有解剖学区域(anatomical territory),包括皮肤、浅筋膜、深筋膜及其深层的各种组织。血管体呈树形分支,其口径逐渐变细并与周围邻近血管体的类似血管形成血管网相连接,这种口径逐渐减小而互相吻合的血管网被称之为"choke vessels"。 展开更多
关键词 vessels 穿支皮瓣 临床解剖学 血管网 血管形成 浅筋膜 深筋膜 口径
下载PDF
糖尿病足相关的choke vessels微环境特征研究进展 被引量:2
16
作者 魏鹏 唐茂林 +1 位作者 徐达传 王建红 《现代实用医学》 2015年第2期143-144,共2页
近年来,糖尿病人群越来越多,其发病率逐年升高,其并发症糖尿病足患者也随之增多。很多学者从基础和临床的角度对糖尿病足进行了大量研究,对其形成机制、相关影响因素及治疗方面均取得进展,但糖尿病足相关的choke vessels微环境的特征还... 近年来,糖尿病人群越来越多,其发病率逐年升高,其并发症糖尿病足患者也随之增多。很多学者从基础和临床的角度对糖尿病足进行了大量研究,对其形成机制、相关影响因素及治疗方面均取得进展,但糖尿病足相关的choke vessels微环境的特征还有待进一步研究。本文就糖尿病足溃疡周围的choke vessels相关的研究情况及存在的问题综述如下。 展开更多
关键词 CHOKE vessels 微环境 问题综述 影响因素 基本病理 始动因素 供区 周围血管病变 形成机制 慢性溃疡
下载PDF
Evaluation of Clinical Outcomes of ses Stent in Patients with Coronary Artery Disease After Intracoronary Stenting in Small Vessels
17
作者 葛长江 吕树铮 柳弘 《心肺血管病杂志》 CAS 2010年第S1期67-67,共1页
Background:Limited data are available for sirolimus-eluting stent(SES,Cypher)implantation in patients with coronary artery disease in small vessels.The clinical longtermoutcomes of SES in patients with coronary artery... Background:Limited data are available for sirolimus-eluting stent(SES,Cypher)implantation in patients with coronary artery disease in small vessels.The clinical longtermoutcomes of SES in patients with coronary artery disease after intracoronary stenting in small vessels has not been yet evaluated. 展开更多
关键词 Evaluation of Clinical Outcomes of ses Stent in Patients with Coronary Artery Disease After Intracoronary Stenting in Small vessels
下载PDF
Electro-acupuncture at Conception and Governor vessels and transplantation of umbilical cord bloodderived mesenchymal stem cells for treating cerebral ischemia/reperfusion injury 被引量:14
18
作者 Haibo Yu Pengdian Chen +4 位作者 Zhuoxin Yang Wenshu Luo Min Pi Yonggang Wu Ling Wang 《Neural Regeneration Research》 SCIE CAS CSCD 2014年第1期84-91,共8页
Mesenchymal stem cell transplantation is a novel means of treating cerebral ischemia/reper- fusion, and can promote angiogenesis and neurological functional recovery. Acupuncture at Conception and Governor vessels als... Mesenchymal stem cell transplantation is a novel means of treating cerebral ischemia/reper- fusion, and can promote angiogenesis and neurological functional recovery. Acupuncture at Conception and Governor vessels also has positive effects as a treatment for cerebral ischemia/ reperfusion. Therefore, we hypothesized that electro-acupuncture at Conception and Governor vessels plus mesenchymal stem cell transplantation may have better therapeutic effects on the promotion of angiogenesis and recovery of neurological function than either treatment alone. In the present study, human umbilical cord blood-derived mesenchymal stem cells were isolated, cultured, identified and intracranially transplanted into the striatum and subcortex of rats at 24 hours following cerebral ischemia/reperfusion. Subsequently, rats were electro-acupunctured at Conception and Governor vessels at 24 hours after transplantation. Modified neurological severity scores and immunohistochemistry findings revealed that the combined interventions of electro-acupuncture and mesenchymal stem cell transplantation clearly improved neurological impairment and up-regulated vascular endothelial growth factor expression around the isch- emic focus. The combined intervention provided a better outcome than mesenchymal stem cell transplantation alone. These findings demonstrate that electro-acupuncture at Conception and Governor vessels and mesenchymal stem cell transplantation have synergetic effects on promot- ing neurological function recovery and angiogenesis in rats after cerebral ischemia/reperfusion. 展开更多
关键词 nerve regeneration acupuncture human umbilical cord blood-derived mesenchymalstem cells ELECTRO-ACUPUNCTURE cerebral ischemia/reperfusion vascular endothelial growth factor angiogenesis Conception vessel Governor vessel modified neurological severity score NSFC grant neural regeneration
下载PDF
Robust Leader-Follower Formation Tracking Control of Multiple Underactuated Surface Vessels 被引量:6
19
作者 彭周华 王丹 +1 位作者 兰维瑶 孙刚 《China Ocean Engineering》 SCIE EI 2012年第3期521-534,共14页
This paper is concerned with the formation control problem of multiple underactuated surface vessels moving in a leader-follower formation. The formation is achieved by the follower to track a virtual target defined r... This paper is concerned with the formation control problem of multiple underactuated surface vessels moving in a leader-follower formation. The formation is achieved by the follower to track a virtual target defined relative to the leader. A robust adaptive target tracking law is proposed by using neural network and backstepping techniques. The advantage of the proposed control scheme is that the uncertain nonlinear dynamics caused by Coriolis/centripetal forces, nonlinear damping, unmodeled hydrodynamics and disturbances from the environment can be compensated by on line learning. Based on Lyapunov analysis, the proposed controller guarantees the tracking errors converge to a small neighborhood of the origin. Simulation results demonstrate the effectiveness of the control strategy. 展开更多
关键词 marine surface vessel formation control neural network BACKSTEPPING LEADER-FOLLOWER
下载PDF
Load Bearing Capacity and Safety Analysis for Strain-hardening Austenitic Stainless Steel Pressure Vessels 被引量:7
20
作者 CHEN Gang DENG Yangchun 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2011年第2期179-186,共8页
By increasing the yield strengths of austenitic stainless steels for pressure vessels with strain hardening techniques,the elastic load bearing capacity of austenitic stainless steel pressure vessels can be significan... By increasing the yield strengths of austenitic stainless steels for pressure vessels with strain hardening techniques,the elastic load bearing capacity of austenitic stainless steel pressure vessels can be significantly improved.Two kinds of strain hardening methods are often used for austenitic stainless steel pressure vessels:Avesta model for ambient temperature applications and Ardeform model for cryogenic temperature applications.Both methods are obtained from conventional design rules based on the linear elastic theory,and only consider the hardening effect from materials.Consequently this limits the applications of strain hardening techniques for austenitic stainless steel pressure vessels because of safety concerns.This paper investigates the effect of strain hardening on the load bearing capacity of austenitic stainless steel pressure vessels under large deformation,based on the elastic-plastic theory.Firstly,to understand the effect of strain hardening on material behavior,the plastic instability loads of a round tensile bar specimen are derived under two different loading paths and validated by experiments.Secondly,to investigate the effect of strain hardening on pressure vessels strength, the plastic instability pressure under strain hardening is derived and further validated by finite element simulations.Further,the safety margin of pressure vessels after strain hardening is analyzed by comparing the safety factor values calculated from bursting tests,finite element analyses,and standards.The researching results show that the load bearing capacity of pressure vessels at ambient temperature is independent of the loading history when the effects of both material strain hardening and structural deformation are considered.Finite element simulations and bursting tests results show that the minimum safety factor of austenitic stainless steel pressure vessels with 5% strain hardening is close to the recommended value for common pressure vessels specified in the European pressure vessel standard.The proposed study also shows that in the strain hardening design of austenitic stainless steel pressure vessels,the calculation for plastic instability pressure could use theoretical formula or finite element analyses based on geometrical dimensions and material property parameters before strain hardening,but a 5%strain should be employed as a design limit.The proposed research can be used for the strain hardening design of austenitic stainless steel pressure vessels safely. 展开更多
关键词 pressure vessel austenitic stainless steel strain hardening load bearing capacity safety margin
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部