期刊文献+
共找到12篇文章
< 1 >
每页显示 20 50 100
Evaluating Low-Cost Commercially Available Sensors for Air Quality Monitoring and Application of Sensor Calibration Methods for Improving Accuracy
1
作者 Nam H. Nguyen Huy X. Nguyen +1 位作者 Thuan T. B. Le Chinh D. Vu 《Open Journal of Air Pollution》 2021年第1期1-17,共17页
In this paper, we present the results of the evaluation of three low-cost laser sensor</span><span style="font-family:Verdana;">s</span><span style="font-family:""><... In this paper, we present the results of the evaluation of three low-cost laser sensor</span><span style="font-family:Verdana;">s</span><span style="font-family:""><span style="font-family:Verdana;"> and comparison with the standard device Metone Aerocet 531s which is capable of counting dust particles as small as 0.3 μm. The sensors used in this study are PMS5003 (Plantower), SPS30 (Sesirion), SM-UART-04L (Amphenol). During the measurement, the overall trend of the outputs from the sensors was similar to that of the Aerocet 531s. The PMS5003 sensor has a relatively small standard error in the all particle measurement ranges (<15 μg/m</span><sup><span style="font-family:Verdana;">3</span></sup><span style="font-family:Verdana;"> in the low particle concentration range). All sensors have a high linearity compared to data from standard equipment, PMS5003: PM1.0 R</span><sup><span style="font-family:Verdana;">2</span></sup><span style="font-family:Verdana;"> = 0.89;PM2.5 R</span><sup><span style="font-family:Verdana;">2</span></sup><span style="font-family:Verdana;"> = 0.95;PM10 R</span><sup><span style="font-family:Verdana;">2</span></sup><span style="font-family:Verdana;"> = 0.87;SPS30 PM2.5 R</span><sup><span style="font-family:Verdana;">2</span></sup><span style="font-family:Verdana;"> = 0.95 and PM10 R</span><sup><span style="font-family:Verdana;">2</span></sup><span style="font-family:Verdana;"> = 0.99;SM-UART-04L PM1.0 R</span><sup><span style="font-family:Verdana;">2</span></sup><span style="font-family:Verdana;"> = 0.98. Three main sensor calibration methods (single-point calibration, two-point calibration and multi-point curve correction) with implementation steps for each method as well as their practical applications in calibrating low-cost air quality sensors according to standard measuring equipment are also detailed illustrated. 展开更多
关键词 Air Quality sensors sensor calibration Air Pollution Fine Particle Laser Particle sensor PM1.0 PM2.5 PM10
下载PDF
Validation of virtual sensor-assisted Bayesian inference-based in-situ sensor calibration strategy for building HVAC systems
2
作者 Guannan Li Jiahao Xiong +1 位作者 Shaobo Sun Jian Chen 《Building Simulation》 SCIE EI CSCD 2023年第2期185-203,共19页
For building heating,ventilation and air-conditioning systems(HVACs),sensor faults significantly affect the operation and control.Sensors with accurate and reliable measurements are critical for ensuring the precise i... For building heating,ventilation and air-conditioning systems(HVACs),sensor faults significantly affect the operation and control.Sensors with accurate and reliable measurements are critical for ensuring the precise indoor thermal demand.Owing to its high calibration accuracy and in-situ effectiveness,a virtual sensor(VS)-assisted Bayesian inference(VS-BI)sensor calibration strategy has been applied for HVACs.However,the application feasibility of this strategy for wider ranges of different sensor types(within-control-loop and out-of-control-loop)with various sensor bias fault amplitudes,and influencing factors that affect the practical in-situ calibration performance are still remained to be explored.Hence,to further validate its in-situ calibration performance and analyze the influencing factors,this study applied the VS-BI strategy in a HVAC system including a chiller plant with air handle unit(AHU)terminal.Three target sensors including air supply(SAT),chilled water supply(CHS)and cooling water return(CWR)temperatures are investigated using introduced sensor bias faults with eight different amplitudes of[−2℃,+2℃]with a 0.5℃ interval.Calibration performance is evaluated by considering three influencing factors:(1)performance of different data-driven VSs,(2)the influence of prior standard deviationsσon in-situ sensor calibration and(3)the influence of data quality on in-situ sensor calibration from the perspective of energy conservation and data volumes.After comparison,a long short term memory(LSTM)is adopted for VS construction with determination coefficient R-squared of 0.984.Results indicate thatσhas almost no impact on calibration accuracy of CHS but scanty impact on that of SAT and CWR.The potential of using a prior standard deviationσto improve the calibration accuracy is limited,only 8.61%on average.For system within-control-loop sensors like SAT and CHS,VS-BI obtains relatively high in-situ sensor calibration accuracy if the data quality is relatively high. 展开更多
关键词 heating ventilation and air-conditioning(HVAC) in-situ sensor calibration Bayesian inference(BI) virtual sensor(VS) influencing factor energy conservation(EC)
原文传递
WRIST FORCE SENSOR'S DYNAMIC PERFORMANCE CALIBRATION BASED ON NEGATIVE STEP RESPONSE 被引量:2
3
作者 ZHENG Hongmei 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2008年第5期92-96,共5页
Negative step response experimental method is used in wrist force sensor's dynamic performance calibration. The exciting manner of negative step response method is the same as wrist force sensor's load in working. T... Negative step response experimental method is used in wrist force sensor's dynamic performance calibration. The exciting manner of negative step response method is the same as wrist force sensor's load in working. This experimental method needn't special experiment equipments. Experiment's dynamic repeatability is good. So wrist force sensor's dynamic performance is suitable to be calibrated by negative step response method. A new correlation wavelet transfer method is studied. By wavelet transfer method, the signal is decomposed into two dimensional spaces of time-frequency. So the problem of negative step exciting energy concentrating in the low frequency band is solved. Correlation wavelet transfer doesn't require that wavelet primary function be orthogonal and needn't wavelet reconstruction. So analyzing efficiency is high. An experimental bench is designed and manufactured to load the wrist force sensor orthogonal excitation force/moment. A piezoelectric force sensor is used to setup soft trigger and calculate the value of negative step excitation. A wrist force sensor is calibrated. The pulse response function is calculated after negative step excitation and step response have been transformed to positive step excitation and step response. The pulse response function is transferred to frequency response function. The wrist force sensor's dynamic characteristics are identified by the frequency response function. 展开更多
关键词 Wrist force sensor Dynamic performance calibration Step response experiment Correlation wavelet transfer Impulse response function
下载PDF
Application of low-cost particulate matter sensors for air quality monitoring and exposure assessment in underground mines:A review 被引量:1
4
作者 Nana A.Amoah Guang Xu +3 位作者 Yang Wang Jiayu Li Yongming Zou Baisheng Nie 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2022年第8期1475-1490,共16页
Exposure to mining-induced particulate matter(PM)including coal dust and diesel particulate matter(DPM)causes severe respirat-ory diseases such as coal workers’pneumoconiosis(CWP)and lung cancer.Limited spatiotempora... Exposure to mining-induced particulate matter(PM)including coal dust and diesel particulate matter(DPM)causes severe respirat-ory diseases such as coal workers’pneumoconiosis(CWP)and lung cancer.Limited spatiotemporal resolution of current PM monitors causes miners to be exposed to unknown PM concentrations,with increased overexposure risk.Low-cost PM sensors offer a potential solution to this challenge with their capability in characterizing PM concentrations with high spatiotemporal resolution.However,their application in underground mines has not been explored.With the aim of examining the potential application of low-cost sensors in underground mines,a critical review of the present status of PM sensor research is conducted.The working principles of present PM monitors and low-cost sensors are com-pared.Sensor error sources are identified,and comprehensive calibration processes are presented to correct them.Evaluation protocols are pro-posed to evaluate sensor performance prior to deployment,and the potential application of low-cost sensors is discussed. 展开更多
关键词 particulate matter low-cost sensors air quality underground mine sensor calibration
下载PDF
Multi-dimensional force sensor for haptic interaction:a review 被引量:2
5
作者 Aiguo SONG Liyue FU 《Virtual Reality & Intelligent Hardware》 2019年第2期121-135,共15页
Haptic interaction plays an important role in the virtual reality technology,which let a person not only view the 3D virtual environment but also realistically touch the virtual environment.As a key part of haptic int... Haptic interaction plays an important role in the virtual reality technology,which let a person not only view the 3D virtual environment but also realistically touch the virtual environment.As a key part of haptic interaction,force feedback has become an essential function for the haptic interaction.Therefore,multi-dimensional force sensors are widely used in the fields of virtual reality and augmented reality.In this paper,some conventional multi-dimensional force sensors based on different measurement principles,such as resistive,capacitive,piezoelectric,are briefly introduced.Then the mechanical structures of the elastic body of multi-dimensional force sensors are reviewed.It is obvious that the performance of the multi-dimensional force sensor is mainly dependent upon the mechanical structure of elastic body.Furthermore,the calibration process of the force sensor is analyzed,and problems in calibration are discussed.Interdimensional coupling error is one of the main factors affecting the measurement precision of the multi-dimensional force sensors.Therefore,reducing or even eliminating dimensional coupling error becomes a fundamental requirement in the design of multi-dimensional force sensors,and the decoupling state-of-art of the multi-dimensional force sensors are introduced in this paper.At last,the trends and current challenges of multi-dimensional force sensing technology are proposed. 展开更多
关键词 Haptic interaction Virtual reality Multi-dimensional force sensor Elastic body DECOUPLING Force sensor calibration
下载PDF
Prototyping low-cost automatic weather stations for natural disaster monitoring
6
作者 Gabriel F.L.R.Bernardes Rogerio Ishibashi +2 位作者 Andre A.S.Ivo Valerio Rosset Bruno Y.L.Kimura 《Digital Communications and Networks》 SCIE CSCD 2023年第4期941-956,共16页
Weather events put human lives at risk mostly when people might occupy areas susceptible to natural disasters.Deploying Professional Weather Stations(PWS)in vulnerable areas is key for monitoring weather with reliable... Weather events put human lives at risk mostly when people might occupy areas susceptible to natural disasters.Deploying Professional Weather Stations(PWS)in vulnerable areas is key for monitoring weather with reliable measurements.However,such professional instrumentation is notably expensive while remote sensing from a number of stations is paramount.This imposes challenges on the large-scale weather station deployment for broad monitoring from large observation networks such as in Cemaden—The Brazilian National Center for Monitoring and Early Warning of Natural Disasters.In this context,in this paper,we propose a Low-Cost Automatic Weather Station(LCAWS)system developed from Commercial Off-The-Shelf(COTS)and open-source Internet of Things(IoT)technologies,which provides measurements as reliable as a reference PWS for natural disaster monitoring.When being automatic,LCAWS is a stand-alone photovoltaic system connected wirelessly to the Internet in order to provide real-time reliable end-to-end weather measurements.To achieve data reliability,we propose an intelligent sensor calibration method to correct measures.From a 30-day uninterrupted observation with sampling in minute resolution,we show that the calibrated LCAWS sensors have no statistically significant differences from the PWS measurements.As such,LCAWS has opened opportunities for reducing maintenance costs in Cemaden's observational network. 展开更多
关键词 Wireless automatic weather station Low-cost weather instrumentation Natural disaster monitoring Intelligent sensor calibration Internet of things
下载PDF
Automatic modeling algorithm of stochastic error for inertial sensors
7
作者 Luodi Zhao Long Zhao 《Control Theory and Technology》 EI CSCD 2024年第1期81-91,共11页
This paper proposes an automatic algorithm to determine the properties of stochastic processes and their parameters for inertial error. The proposed approach is based on a recently developed method called the generali... This paper proposes an automatic algorithm to determine the properties of stochastic processes and their parameters for inertial error. The proposed approach is based on a recently developed method called the generalized method of wavelet moments (GMWM), whose estimator was proven to be consistent and asymptotically normally distributed. This algorithm is suitable mainly (but not only) for the combination of several stochastic processes, where the model identification and parameter estimation are quite difficult for the traditional methods, such as the Allan variance and the power spectral density analysis. This algorithm further explores the complete stochastic error models and the candidate model ranking criterion to realize automatic model identification and determination. The best model is selected by making the trade-off between the model accuracy and the model complexity. The validation of this approach is verified by practical examples of model selection for MEMS-IMUs (micro-electro-mechanical system inertial measurement units) in varying dynamic conditions. 展开更多
关键词 GMWM Stochastic process Inertial sensor sensor calibration Error model Allan variance
原文传递
温压炸药爆温无线存储测试系统设计 被引量:6
8
作者 刘帆 范锦彪 +4 位作者 杜红棉 焦耀晗 刘世龙 梁永烨 苗松珍 《传感技术学报》 CAS CSCD 北大核心 2014年第4期467-471,共5页
温压炸药爆轰时间长、爆炸温度高且伴随爆炸破坏作用,使其爆炸温度测试较困难。为有效评估温压弹药的热毁伤效应,将存储测试技术应用到爆炸瞬态高温测试中,并结合无线传感网络技术,在确保参试人员的安全前提下,可在500 m外远程监控测试... 温压炸药爆轰时间长、爆炸温度高且伴随爆炸破坏作用,使其爆炸温度测试较困难。为有效评估温压弹药的热毁伤效应,将存储测试技术应用到爆炸瞬态高温测试中,并结合无线传感网络技术,在确保参试人员的安全前提下,可在500 m外远程监控测试仪器状态进行智能化测试。系统采用E12型热电偶,响应时间短,最大测温为2 300℃,并对其进行可溯源性动态校准,确保测试精度。测试装置成功应用于小当量温压弹药的实爆现场测试,试验结果表明所设计的系统操作简单、使用安全,具有良好的应用前景。 展开更多
关键词 温压炸药 存储测试 无线传感网络 动态校准 现场测试
下载PDF
Extrinsic calibration of a laser displacement sensor in a non-contact coordinate measuring machine 被引量:9
9
作者 Chao BI Jianguo FANG +1 位作者 Kun LI Zhijun GUO 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2017年第4期1528-1537,共10页
In order to implement 3D scanning of those complicated parts such as blades in the aviation field,a non-contact optical measuring system is established in the paper,which integrates a laser displacement sensor,a probe... In order to implement 3D scanning of those complicated parts such as blades in the aviation field,a non-contact optical measuring system is established in the paper,which integrates a laser displacement sensor,a probe head,the frame of a coordinate measuring machine(CMM),etc.As the output of the laser sensor directly obtained possesses the 1D length of the laser beam,it needs to determine the unit direction vector of the laser beam denoted as(l,m,n)by calibration so as to convert the 1D values into 3D coordinates of target points.Therefore,an extrinsic calibration method based on a standard sphere is proposed to accomplish this task in the paper.During the calibration procedure,the laser sensor moves along with the motion of the CMM and gathers the required data on the spherical surface.Then,both the output of the laser sensor and the grating readings of the CMM are substituted into the constraint equation of the spherical surface,in which an over-determined nonlinear equation group containing unknown parameters is established.For the purpose of solving the equation group,a method based on non-linear least squares optimization is put forward.Finally,the system after calibration is utilized to measure the diameter of a metallic sphere 10 times from different orientations to verify the calibration accuracy.In the experiment,the errors between the measured results and the true values are all smaller than 0.03 mm,which manifests the validity and practicality of the extrinsic calibration method presented in the paper. 展开更多
关键词 CMM 3D scanning Extrinsic calibration Laser displacement sensor Non-linear least squares
原文传递
GIS用超高频传感器的校准:不同校准方法的比较及一种采用锥形天线的校准系统测试(英文) 被引量:2
10
作者 David Gautschi Pierre Bertholet 《高电压技术》 EI CAS CSCD 北大核心 2011年第11期2643-2648,共6页
Different methods of calibrating ultra high frequency(UHF) sensors for gas-insulated substations(GIS) were investigated in the past.The first approach was to use strip lines,triplates and TEM calibration cells.These c... Different methods of calibrating ultra high frequency(UHF) sensors for gas-insulated substations(GIS) were investigated in the past.The first approach was to use strip lines,triplates and TEM calibration cells.These cells had already been in use for years for example to test the electromagnetic compatibility of electronic devices.The smaller the size of the cell,the higher its bandwidth-but the cell should be large enough to not disturb the electric field with the installed sensor under test.To overcome this problem,a calibration procedure using a gigahertz transverse electromagnetic (GTEM) test cell and a pulsed signal source were introduced in 1997.Although this procedure has many advantages and is easy to understand,measurements show several shortcomings of this calibration method.To overcome the disadvantages of the known systems,a calibration cell using a monopole cone antenna and a metallic ground plane were developed and tested.The UHF sensor was placed in a region with minimum distortion of the electric field due to its installation.Experience shows that the new method for calibrating UHF sensors is necessary in order to overcome the limits in the calibration of large sensors and to suppress the propagation of higher order modes and reflections.Due to its surprisingly simple structure,its low price and low overall measurement uncertainty,it is the preferred method for calibrating UHF sensors for GIS applications. 展开更多
关键词 ultra high frequency(UHF) sensors partial discharge detection partial discharge monitoring gas insulated substations(GIS) calibration of sensors calibration cells cone calibration system
下载PDF
A Rapid Calibration Technique for Scanning Line-Structured Laser Sensor
11
作者 Li Tao, Changku Sun, ZhiqinXu, Wei Wei State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China 《光学学报》 EI CAS CSCD 北大核心 2003年第S1期839-840,共2页
A novel procedure to calibrate the scanning line-structured laser sensor is presented. A drone composed of two orthogonal planes is designed, with the result that camera parameters and light-plane equation parameters ... A novel procedure to calibrate the scanning line-structured laser sensor is presented. A drone composed of two orthogonal planes is designed, with the result that camera parameters and light-plane equation parameters is achieved simultaneously. 展开更多
关键词 for in of on BE AS LINE A Rapid calibration Technique for Scanning Line-Structured Laser sensor
原文传递
Floor positioning method indoors with smartphone’s barometer 被引量:1
12
作者 Min Yu Feng Xue +1 位作者 Chao Ruan Hang Guo 《Geo-Spatial Information Science》 SCIE CSCD 2019年第2期138-148,I0006,共12页
This paper presents an indoor floor positioning method with the smartphone’s barometer for the purpose of solving the problem of low availability and high environmental dependence of the traditional floor positioning... This paper presents an indoor floor positioning method with the smartphone’s barometer for the purpose of solving the problem of low availability and high environmental dependence of the traditional floor positioning technology.First,an initial floor position algorithm with the“entering”detection algorithm has been obtained.Second,the user’s going upstairs or downstairs activities are identified by the characteristics of the air pressure fluctuation.Third,the moving distance in the vertical direction and the floor change during going upstairs or downstairs are estimated to obtain the accurate floor position.In order to solve the problem of the floor misjudgment from different mobile phone’s barometers,this paper calculates the pressure data from the different cell phones,and effectively reduce the errors of the air pressure estimating the elevation which is caused by the heterogeneity of the mobile phones.The experiment results show that the average correct rate of the floor identification is more than 85%for three types of the cell phones while reducing environmental dependence and improving availability.Further,this paper compares and analyzes the three common floor location methods–the WLAN Floor Location(WFL)method based on the fingerprint,the Neural Network Floor Location(NFL)methods,and the Magnetic Floor Location(MFL)method with our method.The experiment results achieve 94.2%correct rate of the floor identification with Huawei mate10 Pro mobile phone. 展开更多
关键词 Floor positioning smartphone’s barometer sensor calibration indoor location service
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部