期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Seismic Noise Suppression for Ground-Based Investigation of an Inertial Sensor by Suspending the Electrode Cage 被引量:4
1
作者 谭定银 尹航 周泽兵 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第9期9-12,共4页
Performance test of a high precise accelerometer or an inertial sensor on the ground is inevitably limited by the seismic noise. A torsion pendulum has been used to investigate the performances of an electrostatic acc... Performance test of a high precise accelerometer or an inertial sensor on the ground is inevitably limited by the seismic noise. A torsion pendulum has been used to investigate the performances of an electrostatic accelerometer, where the test mass is suspended by a fiber to compensate for its weight, and this scheme demonstrates an advantage, compared with the high-voltage levitation scheme, in which the effect of the seismic noise can be suppressed for a few orders of magnitude in low frequencies. In this work, the capacitive electrode cage is proposed to be suspended by another pendulum, and theoretical analysis shows that the effects of the seismic noise can be further suppressed for more than one order by suspending the electrode cage. 展开更多
关键词 LENGTH Seismic Noise Suppression for Ground-Based Investigation of an Inertial sensor by Suspending the electrode Cage
下载PDF
Studies on Zeolite Modified Electrode(Ⅰ)─Ascorbic Acid Sensor Based on Carbon Paste Electrode Containing Fe(Ⅲ)Y Zeolite
2
作者 Ming Zhu ZOU Hong Ding XU +1 位作者 Jie LU Qin Hua Ru (a Department of Chemistry, Jilin University, Changchun 130023 b Department of Chemistry, the North-East Normal University, Changchun 130022) (To whom correspondence should be addressed ) 《Chinese Chemical Letters》 SCIE CAS CSCD 1997年第3期247-250,共4页
A new ascorbic acid sensor constituted of carbon paste and Fe(Ⅲ)Y zeolite was studied.The characters of the sensor such as linear range. potential window、apparen Michaelis constant、response time、stability and accu... A new ascorbic acid sensor constituted of carbon paste and Fe(Ⅲ)Y zeolite was studied.The characters of the sensor such as linear range. potential window、apparen Michaelis constant、response time、stability and accuracy wee investigated. The experimental results indicate that the analytical performance of the sensor is satisfactory. 展开更多
关键词 Ascorbic Acid sensor Based on Carbon Paste electrode Containing Fe Y Zeolite Studies on Zeolite Modified electrode
下载PDF
An oxygen reduction sensor based on a novel type of porous carbon composite membrane electrode 被引量:4
3
作者 En-Dong Xing Long-Qi Liang +1 位作者 Yu-Jie Dong Wei-Min Huang 《Chinese Chemical Letters》 SCIE CAS CSCD 2015年第10期1322-1326,共5页
The development of a simple, efficient and sensitive sensor for dissolved oxygen is proposed using a novel type of porous carbon composite membrane/glassy carbon electrode based on the low-cost common filter paper by ... The development of a simple, efficient and sensitive sensor for dissolved oxygen is proposed using a novel type of porous carbon composite membrane/glassy carbon electrode based on the low-cost common filter paper by a simple method. The resulting device exhibited excellent electrocatalytic activities toward the oxygen reduction reaction. Scanning electron microscopy, transmission electron microscopy, X-ray photoelectron spectroscopy and electrochemical measurements demonstrated that the porous morphology and uniformly dispersed Fe;C nanoparticles of the PCCM play an important role in the oxygen reduction reaction. A linear response range from 2mmol/L up to 110 mmol/L and a detection limit of 1.4 mmol/L was obtained with this sensor. The repeatability of the proposed sensor,evaluated in terms of relative standard deviation, was 3.0%. The successful fabrication of PCCM/GC electrode may promote the development of new porous carbon oxygen reduction reaction material for the oxygen reduction sensor. 展开更多
关键词 Oxygen sensor Porous carbon composite membrane electrode
原文传递
Efficiency of terahertz detection in electro-optic polymer sensors with interdigitated coplanar electrodes
4
作者 蒋强 王暄 +1 位作者 王玥 李志远 《Chinese Optics Letters》 SCIE EI CAS CSCD 2013年第9期84-86,共3页
We discuss the efficiency of an electro-optic (EO) polymer sensor with interdigitated coplanar electrodes. The developed EO sensor is used to detect terahertz radiation via EO sampling. Results show that the sensor ... We discuss the efficiency of an electro-optic (EO) polymer sensor with interdigitated coplanar electrodes. The developed EO sensor is used to detect terahertz radiation via EO sampling. Results show that the sensor improves more significantly detection sensitivity than does a sensor with sandwich configurations. 展开更多
关键词 VIEW Efficiency of terahertz detection in electro-optic polymer sensors with interdigitated coplanar electrodes THZ
原文传递
A nanosilica/exfoliated graphene composite film-modified electrode for sensitive detection of methyl parathion 被引量:1
5
作者 Ju Fu Xiao-Hong Tan +1 位作者 Yao-Hua Li Xin-Jian Song 《Chinese Chemical Letters》 SCIE CAS CSCD 2016年第9期1541-1546,共6页
Graphene nanosheets (GS) were easily prepared through liquid-phase exfoliation of graphite powder in N,N-dimethylformamide (DMF) with the assistance of sodium citrate. Then, GS was coated onto a glassy carbon elec... Graphene nanosheets (GS) were easily prepared through liquid-phase exfoliation of graphite powder in N,N-dimethylformamide (DMF) with the assistance of sodium citrate. Then, GS was coated onto a glassy carbon electrode (GCE) surface by drop to fabricate a GS]GCE nanointerface. Subsequently, by using tetraethylorthosilicate sol as precursor, nanosilica was electrochemically deposited onto the GS]GCE surface to produce a nanocomposite film electrode (nanosilicaJGSJGCE). Electrochemical behaviors of methyl parathion (MP) on the nanosilica/GS/GCE surface were investigated thoroughly. It was found that the nanosilicaJGS nanocomposites can improve the redox peak currents of MP significantly due to the synergetic effect. The oxidation peak current was linearly related to MP concentration in the range from 0.0005 μmol/L to 5.6 μmol/L. The detection limit was calculated to be 0.07 nmol/L (SJN = 3). The developed method was used to determine MP in real samples. The recoveries were in the range from 95.4% to 104.2%, demonstrating satisfactory results. 展开更多
关键词 Exfoliated graphene Nanosilica Modified electrodes Methyl parathion Electrochemical sensor
原文传递
Electrocatalytic reduction of ortho nitrobenzaldehyde using modified aluminum electrode and its determination
6
作者 Vairamuthu Raj Jayachandran Silambarasan Panchanathan Rajakumar 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2014年第7期1531-1539,共9页
A simple, cost effective and rapid electrochemical method has been developed for the determination of micro level ortho nitrobenzaldehyde(ONB) based on outstanding properties of modified aluminum electrode tin nanor... A simple, cost effective and rapid electrochemical method has been developed for the determination of micro level ortho nitrobenzaldehyde(ONB) based on outstanding properties of modified aluminum electrode tin nanorods/anodic aluminum oxide/aluminum(SnNR/AAO/Al) for the first time. The SnNR/AAO/Al electrode was fabricated by a second step anodization, followed by electrodeposition and its electrochemical behavior was investigated in detail. The cyclic voltammetry results indicated that the SnNR/AAO/Al electrode exhibited efficient electrocatalytic activity toward reduction of ONB in the acidic solution. It provides an appreciable improvement of reduction peak for ONB at-0.721 V.Furthermore, various kinetic parameters such as transfer electron number, transfer proton number and standard heterogeneous rate constant were calculated from the scan rates.The electrocatalytic behavior was further exploited as a sensitive detection scheme for the ONB determination by differential pulse voltammetry. Under the optimized conditions, the concentration range and detection limit are 0.1-100 μmol/L and 0.05 μmol/L, respectively,for ONB. The analytical performance of this modified sensor has been evaluated for detection of real sample such as river water and recovery of ONB was achieved all-out up to102.3% under standard addition method. 展开更多
关键词 Electrochemical sensor Organic pollutant Aluminum electrode Anodic aluminum oxide Tin nanorods Ortho nitrobenzaldehyde Cyclic voltammetry
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部