期刊文献+
共找到42篇文章
< 1 2 3 >
每页显示 20 50 100
Predicting hepatocellular carcinoma: A new non-invasive model based on shear wave elastography
1
作者 Dong Jiang Yi Qian +9 位作者 Yi-Jun Gu Ru Wang Hua Yu Hui Dong Dong-Yu Chen Yan Chen Hao-Zheng Jiang Bi-Bo Tan Min Peng Yi-Ran Li 《World Journal of Gastroenterology》 SCIE CAS 2024年第25期3166-3178,共13页
BACKGROUND Integrating conventional ultrasound features with 2D shear wave elastography(2D-SWE)can potentially enhance preoperative hepatocellular carcinoma(HCC)predictions.AIM To develop a 2D-SWE-based predictive mod... BACKGROUND Integrating conventional ultrasound features with 2D shear wave elastography(2D-SWE)can potentially enhance preoperative hepatocellular carcinoma(HCC)predictions.AIM To develop a 2D-SWE-based predictive model for preoperative identification of HCC.METHODS A retrospective analysis of 884 patients who underwent liver resection and pathology evaluation from February 2021 to August 2023 was conducted at the Oriental Hepatobiliary Surgery Hospital.The patients were divided into the modeling group(n=720)and the control group(n=164).The study included conventional ultrasound,2D-SWE,and preoperative laboratory tests.Multiple logistic regression was used to identify independent predictive factors for RESULTS In the modeling group analysis,maximal elasticity(Emax)of tumors and their peripheries,platelet count,cirrhosis,and blood flow were independent risk indicators for malignancies.These factors yielded an area under the curve of 0.77(95%confidence interval:0.73-0.81)with 84%sensitivity and 61%specificity.The model demonstrated good calibration in both the construction and validation cohorts,as shown by the calibration graph and Hosmer-Lemeshow test(P=0.683 and P=0.658,respectively).Additionally,the mean elasticity(Emean)of the tumor periphery was identified as a risk factor for microvascular invasion(MVI)in malignant liver tumors(P=0.003).Patients receiving antiviral treatment differed significantly in platelet count(P=0.002),Emax of tumors(P=0.033),Emean of tumors(P=0.042),Emax at tumor periphery(P<0.001),and Emean at tumor periphery(P=0.003).CONCLUSION 2D-SWE’s hardness value serves as a valuable marker for enhancing the preoperative diagnosis of malignant liver lesions,correlating significantly with MVI and antiviral treatment efficacy. 展开更多
关键词 shear wave elastography Predicting model Microvascular invasion Antiviral treatment Hepatocellular carcinoma
下载PDF
Application of real-time shear wave elastography to Achilles tendon hardness evaluation in older adults
2
作者 Xuan He Xin Wei +2 位作者 Jia Hou Wei Tan Ping Luo 《World Journal of Clinical Cases》 SCIE 2024年第26期5922-5929,共8页
BACKGROUND Real-time shear wave elastography(SWE)is a non-invasive imaging technique used to measure tissue stiffness by generating and tracking shear waves in real time.This advanced ultrasound-based method provides ... BACKGROUND Real-time shear wave elastography(SWE)is a non-invasive imaging technique used to measure tissue stiffness by generating and tracking shear waves in real time.This advanced ultrasound-based method provides quantitative information regarding tissue elasticity,offering valuable insights into the mechanical properties of biological tissues.However,the application of real-time SWE in the musculoskeletal system and sports medicine has not been extensively studied.AIM To explore the practical value of real-time SWE for assessing Achilles tendon hardness in older adults.METHODS A total of 60 participants were enrolled in the present study,and differences in the elastic moduli of the bilateral Achilles tendons were compared among the following categories:(1)Age:55-60,60-65,and 65-70-years-old;(2)Sex:Male and female;(3)Laterality:Left and right sides;(4)Tendon state:Relaxed and tense state;and(5)Tendon segment:Proximal,middle,and distal.RESULTS There were no significant differences in the elastic moduli of the bilateral Achilles tendons when comparing by age or sex(P>0.05).There were,however,significant differences when comparing by tendon side,state,or segment(P<0.05).CONCLUSION Real-time SWE plays a significant role compared to other examination methods in the evaluation of Achilles tendon hardness in older adults. 展开更多
关键词 Aged Achilles tendon REAL-TIME shear wave elastography Young’s modulus Muscle stiffness
下载PDF
Does shear wave elastography technology provide better value for the assessment of perianal fistulizing Crohn’s disease?
3
作者 Jiong Wu 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第11期3636-3638,共3页
Magnetic resonance imaging is the gold standard compared other clinical fin-dings.But shear wave elastography technique combined with endoscopic ultra-sound can evaluate the degree of fibrosis of fistula tissue in Cr... Magnetic resonance imaging is the gold standard compared other clinical fin-dings.But shear wave elastography technique combined with endoscopic ultra-sound can evaluate the degree of fibrosis of fistula tissue in Crohn’s disease patients.This topic is highly relevant to the current discourse,especially for It shows a certain degree of innovation and practicality and is worthy of study and popularization. 展开更多
关键词 Perianal fistulizing Crohn’s disease shear wave elastography ULTRASOUND Magnetic resonance imaging
下载PDF
Combining the age-male-albumin-bilirubin-platelets score and shear wave elastography stratifies carcinogenic risk in hepatitis C patients after viral clearance 被引量:1
4
作者 Rion Masaoka Yoshinori Gyotoku +2 位作者 Ryosaku Shirahashi Toshikuni Suda Masaya Tamano 《World Journal of Clinical Cases》 SCIE 2023年第22期5204-5214,共11页
BACKGROUND The treatment of hepatitis C with direct-acting antiviral agents(DAAs)produces a high rate of sustained virological response(SVR)with fewer adverse events than interferon(IFN)therapy with a similar effect i... BACKGROUND The treatment of hepatitis C with direct-acting antiviral agents(DAAs)produces a high rate of sustained virological response(SVR)with fewer adverse events than interferon(IFN)therapy with a similar effect in inhibiting carcinogenesis as IFN therapy.The age-male-albumin-bilirubin-platelets(aMAP)score is useful for stratifying the risk of hepatocellular carcinoma in chronic hepatitis patients,and the velocity of shear waves(Vs)measured by shear wave elastography has also been shown to be useful for diagnosing the level of fibrotic progression in hepatitis C and predicting carcinogenic risk.Combining these two may improve the prediction of carcinogenic risk.AIM To determine whether combining the aMAP score with Vs improves carcinogenic risk stratification in medium-to-high-risk hepatitis C patients.METHODS This retrospective,observational study involved hepatitis C patients treated with DAAs who achieved SVR.Vs was measured before treatment(baseline),at the end of treatment(EOT),and 12 wk(follow-up 12)and 24 wk(follow-up 24)after treatment.The patients were followed for at least six months after EOT to determine whether cancer developed.Multiple regression analysis was used to identify factors contributing to hepatic carcinogenesis.The diagnostic performances of clinical parameters for predicting the presence of hepatocellular carcinoma were evaluated using receiver-operating characteristic(ROC)curve analyses.RESULTS A total of 279 patients(mean age 65.9 years,118 males,161 females)were included in the analysis.Multiple regression analysis was performed with carcinogenesis as the target variable and alanine aminotransferase,platelets,α-fetoprotein,Vs,and the Fib-4 index as explanatory variables;only Vs was found to be significant(P=0.0296).The cut-off value for Vs for liver carcinogenesis calculated using the ROC curve was 1.53 m/s.Carcinoma developed in 2.0%(3/151)of those with Vs<1.53 m/s and in 10.5%(9/86)of those with Vs≥1.53 m/s.CONCLUSION In hepatitis C patients after SVR,combining the aMAP score and Vs to stratify the risk of carcinogenesis is more efficient than uniform surveillance of all patients. 展开更多
关键词 Hepatitis C Hepatocellular carcinoma Direct-acting antiviral therapy shear wave elastography Sustained virological response Age-male-albumin-bilirubin-platelets score
下载PDF
Comparative analysis of conventional ultrasound and shear wave elastography features in primary breast diffuse large B-cell lymphoma
5
作者 Xiao-Duan Zhang Kai Zhang 《World Journal of Clinical Cases》 SCIE 2023年第33期7994-8002,共9页
BACKGROUND Primary breast diffuse large B-cell lymphoma(PB-DLBCL)is a rare subtype of non-Hodgkin lymphoma that accounts for<3%of extranodal lymphomas and 1%of breast tumors.Its diagnosis and management are challen... BACKGROUND Primary breast diffuse large B-cell lymphoma(PB-DLBCL)is a rare subtype of non-Hodgkin lymphoma that accounts for<3%of extranodal lymphomas and 1%of breast tumors.Its diagnosis and management are challenging because of its rarity,heterogeneity,and aggressive behavior.Conventional ultrasound(US)is the first-line imaging modality for breast lesions;however,it has limited specificity and accuracy for PB-DLBCL.Shear wave elastography(SWE)is a novel US technique that measures tissue stiffness and may reflect the histological characteristics and biological behavior of breast lesions.AIM To compare the conventional US and SWE features of PB-DLBCL and evaluate their diagnostic performance and prognostic value.METHODS We retrospectively reviewed the clinical data and US images of 32 patients with pathologically confirmed PB-DLBCL who underwent conventional US and SWE before treatment.We analyzed conventional US features(shape,margin,orientation,echo,posterior acoustic features,calcification,and vascularity)and SWE features(mean elasticity value,standard deviation,minimum elasticity value,maximum elasticity value,and lesion-to-fat ratio)of the PB-DLBCL lesions.Using receiver operating characteristic curve analysis,we determined the optimal cutoff values and diagnostic performance of conventional US and SWE features.We also performed a survival analysis to assess the prognostic value of conventional US and SWE features.RESULTS The results showed that the PB-DLBCL lesions were mostly irregular in shape(84.4%),microlobulated or spiculated in margins(75%),parallel in orientation(65.6%),hypoechoic in echo(87.5%),and had posterior acoustic enhancement(65.6%).Calcification was rare(6.3%)and vascularity was variable(31.3%avascular,37.5%hypovascular,and 31.3%hypervascular).The mean elasticity value of PB-DLBCL lesions was significantly higher than that of benign breast lesions(113.4±46.9 kPa vs 27.8±16.4 kPa,P<0.001).The optimal cutoff value of the mean elasticity for distinguishing PB-DLBCL from benign breast lesions was 54.5 kPa,with a sensitivity of 93.8%,specificity of 92.9%,positive predictive value of 93.8%,negative predictive value of 92.9%,and accuracy of 93.3%.The mean elasticity value was also significantly correlated with Ki-67 expression level(r=0.612,P<0.001),which is a marker of tumor proliferation and aggressiveness.Survival analysis showed that patients with higher mean elasticity values(>54.5 kPa)had worse overall survival(OS)and progression-free survival(PFS)than those with lower mean elasticity values(<54.5 kPa)(P=0.038 for OS and P=0.027 for PFS).CONCLUSION Conventional US and SWE provide useful information for diagnosing and forecasting PB-DLBCL.SWE excels in distinguishing PB-DLBCL from benign breast lesions,reflects tumor proliferation and aggressiveness,and improves disease management. 展开更多
关键词 Primary breast diffuse large B-cell lymphoma Conventional ultrasound shear wave elastography Diagnosis PROGNOSIS Tumor behavior
下载PDF
Real-time Shear Wave Elastography Assessment of Muscle Elasticity in Patients with Renal Failure
6
作者 Lei Ran Lei Wang Tingting Cai 《Journal of Clinical and Nursing Research》 2023年第5期66-71,共6页
Objective:To explore the value of real-time elastic shear wave in evaluating muscle elasticity in patients with renal failure.Methods:50 patients with chronic renal failure from January 2019 to December 2022 were rand... Objective:To explore the value of real-time elastic shear wave in evaluating muscle elasticity in patients with renal failure.Methods:50 patients with chronic renal failure from January 2019 to December 2022 were randomly selected as the experimental group,and 50 healthy patients aged 21-61 during the same period were selected as the control group,and the basic information of the patients,including age,gender,body mass index,etc.,were collected.Besides,the Young's modulus of the two groups of patients were observed and analyzed.Results:The Young's modulus values of left and right gastrocnemius muscles in the experimental group were significantly lower than those in the control group(P<0.05),and there was no statistical difference between the left and right sides of the experimental group and the control group(P>0.05).Conclusion:Real-time shear wave elastography provides a non-invasive,real-time and effective tool for the assessment of muscle elasticity in patients with renal failure.Through further research and optimization,real-time shear wave elastography will play a greater role in the prevention and treatment of patients with renal failure,improving the quality of life and prognosis of patients. 展开更多
关键词 Real-time shear wave elastography Renal failure Muscle elasticity
下载PDF
Assessment of Calf Skeletal Muscle Stiffness in Diabetic Nephropathy Patients with Medial Tibial Stress Syndrome by Two-Dimensional Shear Wave Elastography
7
作者 Lei Wang Lei Ran 《Proceedings of Anticancer Research》 2023年第5期11-16,共6页
Objective:To explore the feasibility of two-dimensional shear wave elastography in evaluating calf skeletal muscle stiffness in diabetic nephropathy patients with medial tibial stress syndrome.Methods:A total of 48 di... Objective:To explore the feasibility of two-dimensional shear wave elastography in evaluating calf skeletal muscle stiffness in diabetic nephropathy patients with medial tibial stress syndrome.Methods:A total of 48 diabetic nephropathy patients with medial tibial stress syndrome from January 2020 to December 2022 were included as the study group,and 48 patients with diabetic nephropathy during the same period were included as the control group.Both groups were detected by two-dimensional shear wave elastography with ultrasonic equipment,and Young‘s modulus of the tibialis anterior muscle,tibialis posterior muscle,and gastrocnemius muscle were observed and analyzed in the two groups.Results:The Young‘s modulus values of tibialis anterior muscle,tibialis posterior muscle,and gastrocnemius muscle in the study group were significantly lower than those in the control group(P<0.05).Conclusion:Two-dimensional shear wave elastography is feasible for the evaluation of calf skeletal muscle stiffness in diabetic nephropathy patients with medial tibial stress syndrome,and has high accuracy and repeatability.This technique can be used to diagnose,treat and monitor muscle lesions in patients with diabetic nephropathy,and can also be used to assess muscle fatigue and exercise capacity,which has broad application prospects. 展开更多
关键词 Two-dimensional shear wave elastography Diabetic nephropathy Medial tibial stress syndrome
下载PDF
Study of detection times for liver stiffness evaluation by shear wave elastography 被引量:10
8
作者 Ze-Ping Huang Xin-Ling Zhang +3 位作者 Jie Zeng Jian Zheng Ping Wang Rong-Qin Zheng 《World Journal of Gastroenterology》 SCIE CAS 2014年第28期9578-9584,共7页
AIM: To investigate enough valid measurements (VMs) to assess liver fibrosis in chronic hepatitis B patients (CHB).
关键词 Liver stiffness measurement elastography shear wave elastography Non-invasive diagnosis Liver fibrosis
下载PDF
Ultrasound shear wave elastography and liver fibrosis: A Prospective Multicenter Study 被引量:17
9
作者 Joyce Anyona Sande Suleman Verjee +2 位作者 Sudhir Vinayak Farin Amersi Munir Ghesani 《World Journal of Hepatology》 CAS 2017年第1期38-47,共10页
AIM To assess the accuracy of shear wave elastography(SWE) alone and in combination with aminotransferase platelet ratio index(APRI) score in the staging of liver fibrosis.METHODS A multicenter prospective study was c... AIM To assess the accuracy of shear wave elastography(SWE) alone and in combination with aminotransferase platelet ratio index(APRI) score in the staging of liver fibrosis.METHODS A multicenter prospective study was conducted to assess the accuracy of SWE(medians) and APRI to predict biopsy results. The analysis focused on distinguishing the different stages of liver disease, namely, F0 from F1-4, F0-1 from F2-4, F0-2 from F3-4 and F0-3 from F4; F0-F1 from F2-F4 being of primary interest. The area under the receiver operating characteristic(AUROC) curve was computed using logistic regression model. The role of age, gender and steatosis was also assessed.RESULTS SWE alone accurately distinguished F0-1 from F2-4 with a high probability. The AUROC using SWE alone was 0.91 compared to 0.78 for using the APRI score alone.The APRI score, when used in conjunction with SWE, did not make a significant contribution to the AUROC. SWE and steatosis were the only significant predictors that differentiated F0-1 from F2-4 with an AUROC of 0.944.CONCLUSION Our study validates the use of SWE in the diagnosis and staging of liver fibrosis. Furthermore, the probability of a correct diagnosis is significantly enhanced with the addition of steatosis as a prognostic factor. 展开更多
关键词 shear wave elastography Aminotransferase platelet ration Liver fibrosis Liver biopsy
下载PDF
Non-invasive assessment of liver fibrosis using twodimensional shear wave elastography in patients with autoimmune liver diseases 被引量:8
10
作者 Jie Zeng Ze-Ping Huang +2 位作者 Jian Zheng Tao Wu Rong-Qin Zheng 《World Journal of Gastroenterology》 SCIE CAS 2017年第26期4839-4846,共8页
AIM To determine the diagnostic accuracy of two-dimensional shear wave elastography(2D-SWE) for the noninvasive assessment of liver fibrosis in patients with autoimmune liver diseases(AILD) using liver biopsy as the r... AIM To determine the diagnostic accuracy of two-dimensional shear wave elastography(2D-SWE) for the noninvasive assessment of liver fibrosis in patients with autoimmune liver diseases(AILD) using liver biopsy as the reference standard.METHODS Patients with AILD who underwent liver biopsy and 2D-SWE were consecutively enrolled. Receiver operating characteristic(ROC) curves were constructed to assess the overall accuracy and to identify optimal cut-off values.RESULTS The characteristics of the diagnostic performance were determined for 114 patients with AILD. The areas under the ROC curves for significant fibrosis, severe fibrosis, and cirrhosis were 0.85, 0.85, and 0.86, respectively, and the optimal cut-off values associated with significant fibrosis(≥ F2), severe fibrosis(≥ F3), and cirrhosis(F4) were 9.7 k Pa, 13.2 k Pa and 16.3 k Pa, respectively. 2D-SWE showed sensitivity values of 81.7% for significant fibrosis, 83.0% for severe fibrosis,and 87.0% for cirrhosis, and the respective specificity values were 81.3%, 74.6%, and 80.2%. The overall concordance rate of the liver stiffness measurements obtained using 2D-SWE vs fibrosis stages was 53.5%.CONCLUSION2D-SWE showed promising diagnostic performance for assessing liver fibrosis stages and exhibited high cut-off values in patients with AILD. Low overall concordance rate was observed in the liver stiffness measurements obtained using 2D-SWE vs fibrosis stages. 展开更多
关键词 Autoimmune liver disease Liver fibrosis Two-dimensional shear wave elastography ULTRASOUND Liver stiffness
下载PDF
Value of shear wave elastography with maximal elasticity in differentiating benign and malignant solid focal liver lesions 被引量:10
11
作者 Hui-Ping Zhang Ji-Ying Gu +3 位作者 Min Bai Fan Li Yu-Qing Zhou Lian-Fang Du 《World Journal of Gastroenterology》 SCIE CAS 2020年第46期7416-7424,共9页
BACKGROUND It is important to differentiate benign and malignant focal liver lesions(FLLs)accurately.Despite the wide use and acceptance of shear wave elastography(SWE),its value for assessing the elasticity of FLLs a... BACKGROUND It is important to differentiate benign and malignant focal liver lesions(FLLs)accurately.Despite the wide use and acceptance of shear wave elastography(SWE),its value for assessing the elasticity of FLLs and differentiating benign and malignant FLLs is still investigational.Previous studies of SWE for FLLs used mean elasticity as the parameter to reflect the stiffness of FLLs.Considering the inhomogeneity of tumor stiffness,maximal elasticity(Emax)might be the suitable parameter to reflect the stiffness of FLLs and to differentiate malignant FLLs from benign ones.AIM To explore the value of SWE with Emax in differential diagnosis of solid FLLs.METHODS We included 104 solid FLLs in 95 patients and 50 healthy volunteers.All the subjects were examined using conventional ultrasound(US)and virtual touch tissue quantification(VTQ)imaging.A diagnosis of benign or malignant FLL was made using conventional US.Ten VTQ values were acquired after 10 consecutive measurements for each FLL and each normal liver,and the largest value was recorded as Emax.RESULTS There were 56 cases of malignant FLLs and 48 cases of benign FLLs in this study.Emax of malignant FLLs(3.29±0.88 m/s)was significantly higher than that of benign FLLs(1.30±0.46 m/s,P<0.01)and that of livers in healthy volunteers(1.15±0.17 m/s,P<0.01).The cut-off point of Emax was 1.945,and the area under the curve was 0.978.The sensitivity and specificity of Emax were 92.9%and 91.7%,respectively,higher(but not significantly)than those of conventional US(80.4%for sensitivity and 81.3%for specificity).Combined diagnosis of conventional US and Emax using parallel testing improved the sensitivity to 100%with specificity of 75%.CONCLUSION SWE is a convenient and easy method to obtain accurate stiffness information of solid FLLs.Emax is useful for differential diagnosis of FLLs,especially in combination with conventional US. 展开更多
关键词 Focal hepatic lesions shear wave elastography Conventional ultrasound Maximal elasticity
下载PDF
Shear wave elastography results correlate with liver fibrosis histology and liver function reserve 被引量:7
12
作者 Yan-Hong Feng Xiang-Dong Hu +6 位作者 Lin Zhai Ji-Bin Liu Lan-Yan Qiu Yuan Zu Si Liang Yu Gui Lin-Xue Qian 《World Journal of Gastroenterology》 SCIE CAS 2016年第17期4338-4344,共7页
AIM: To evaluate the correlation of shear wave elastography (SWE) results with liver fibrosis histology and quantitative function reserve. METHODS: Weekly subcutaneous injection of 60% carbon tetrachloride (1.5 mL/kg)... AIM: To evaluate the correlation of shear wave elastography (SWE) results with liver fibrosis histology and quantitative function reserve. METHODS: Weekly subcutaneous injection of 60% carbon tetrachloride (1.5 mL/kg) was given to 12 canines for 24 wk to induce experimental liver fibrosis, with olive oil given to 2 control canines. At 24 wk, liver condition was evaluated using clinical biochemistry assays, SWE imaging, lidocaine metabolite monoethylglycine-xylidide (MEGX) test, and histologic fibrosis grading. Clinical biochemistry assays were performed at the institutional central laboratory for routine liver function evaluation. Liver stiffness was measured in triplicate from three different intercostal spaces and expressed as mean liver stiffness modulus (LSM). Plasma concentrations of lidocaine and its metabolite MEGX were determined using high-performance liquid chromatography repeated in duplicate. Liver biopsy samples were fixed in 10% formaldehyde, and liver fibrosis was graded using the modified histological activity index Knodell score (F0-F4). Correlations among histologic grading, LSM, and MEGX measures were analyzed with the Pearson linear correlation coefficient. RESULTS: At 24 wk liver fibrosis histologic grading was as follows: F0, n = 2 (control); F1, n = 0; F2, n = 3; F3, n = 7; and F4, n = 2. SWE LSM was positively correlated with histologic grading (r = 0.835, P < 0.001). Specifically, the F4 group had a significantly higher elastic modulus than the F3, F2, and F0 groups (P = 0.002, P = 0.003, and P = 0.006, respectively), and the F3 group also had a significantly higher modulus than the control F0 group (P = 0.039). LSM was negatively associated with plasma MEGX concentrations at 30 min (r = -0.642; P = 0.013) and 60 min (r = -0.651; P = 0.012), time to 1/2 of the maximum concentration (r = -0.538; P = 0.047), and the area under the curve (r = -0.636; P = 0.014). Multiple comparisons showed identical differences in these three measures: significantly lower with F4 (P = 0.037) and F3 (P = 0.032) as compared to F0 and significantly lower with F4 as compared to F2 (P = 0.032). CONCLUSION: SWE LSM shows a good correlation with histologic fibrosis grading and pharmacologic quantitative liver function reserve in experimental severe fibrosis and cirrhosis. 展开更多
关键词 Liver fibrosis Histologic grading shear wave elastography Monoethylglycinexylidide test Experimental study
下载PDF
Application of Shear Wave Elastography and Contrast-Enhanced Ultrasound in Transrectal Prostate Biopsy 被引量:8
13
作者 Gao-wa SHAREN Jun ZHANG 《Current Medical Science》 SCIE CAS 2022年第2期447-452,共6页
Objective To explore the clinical value of ultrasound shear wave elastography(SWE)and contrast-enhanced ultrasound(CEUS)in transrectal prostate biopsy.Methods A total of 54 patients(average age:67.79±12.01 years)... Objective To explore the clinical value of ultrasound shear wave elastography(SWE)and contrast-enhanced ultrasound(CEUS)in transrectal prostate biopsy.Methods A total of 54 patients(average age:67.79±12.01 years)in the experimental group underwent transrectal prostate biopsy under the guidance of SWE,while 46 patients(average age:69.22±11.54 years)in the control group underwent transrectal prostate biopsy guided by CEUS.Results There were a total of 451 needles,with an average of 8.35±1.67 needles per patient in the experimental group,and a total of 462 needles,with an average of 10.04±1.33 needles per patient in the control group.The difference in puncture times between the two groups was statistically significant(P<0.05).There was no significant difference in the positive detection rate,sensitivity or specificity between the two groups(P>0.05),but there was a significant difference in the diagnostic accuracy between the two groups(P<0.05).The E_(mean)and E_(max)of prostate cancer were significantly higher in the experimental group than in benign prostatic hyperplasia(P<0.05).The receiver operating characteristic curve(ROC)analysis showed that the area under the ROC curve(AUC)of E_(mean)was 0.752(S.E.=0.072,95%CI=0.611-0.894,P=0.007),and the best cutoff value was 47.005 kPa.Conclusion In summary,both SWE-and CEUS-guided transrectal prostate biopsy can help find the focus and guide the puncture,and improve the positive detection rate. 展开更多
关键词 prostate puncture ultrasonic shear wave elastography contrast-enhanced ultrasound biopsy analysis
下载PDF
Evaluation of internal and shell stiffness in the differential diagnosis of breast non-mass lesions by shear wave elastography 被引量:7
14
作者 Ping Xu Mei Wu +3 位作者 Min Yang Juan Xiao Zheng-Min Ruan Lan-Ying Wu 《World Journal of Clinical Cases》 SCIE 2020年第12期2510-2519,共10页
BACKGROUND The diagnostic specificity of conventional ultrasound for breast non-mass lesions(NMLs)is low at approximately 21%-43%.Shear wave elastography(SWE)can distinguish benign from malignant lesions by evaluating... BACKGROUND The diagnostic specificity of conventional ultrasound for breast non-mass lesions(NMLs)is low at approximately 21%-43%.Shear wave elastography(SWE)can distinguish benign from malignant lesions by evaluating the internal and peripheral stiffness.SWE has good reproducibility and high diagnostic efficacy.However,there are very few independent studies on the diagnostic value of SWE in breast NMLs.AIM To determine the value of SWE in the differential diagnosis of breast NMLs.METHODS This study enrolled a total of 118 patients with breast NMLs who underwent SWE examinations in the Beijing Shijitan Hospital Affiliated to Capital Medical University and The Second Hospital of Shandong University from January 2019 to January 2020.The internal elastic parameters of the lesions were recorded,including maximum(Emax),mean(Emean)and minimum elastic values and the standard deviation.The following peripheral parameters were noted:Presence of a“stiff rim”sign;Emax,and Emean elasticity values within 1 mm,1.5 mm,2 mm,2.5 mm and 3 mm from the edge of NMLs.The receiver operating characteristic curve of each parameter was drawn,and the areas under the curve were calculated.RESULTS Emax,Emean and elastic values,and the standard deviation of the internal elastic values in malignant NMLs were significantly higher than those in benign NMLs(P<0.05).The percentage with the“stiff rim”sign in malignant NMLs was significantly higher than that in the benign group(P<0.05),and Emax and Emean at the shell of 1 mm,1.5 mm,2 mm,2.5 mm and 3 mm in the malignant group were all higher than those in the benign group(P<0.05).Of the surrounding elasticity values,Emax of the shell at 2.5 mm in malignant NMLs had maximum areas under the curve of 0.900,and the corresponding sensitivity and specificity were 94.57%and 85.86%,respectively.CONCLUSION The“stiff rim”sign and multiple quantitative elastic values within and around the lesion had good diagnostic performance in the differential diagnosis of breast NMLs.Emax in peripheral tissue had better diagnostic efficiency than other parameters. 展开更多
关键词 Breast tumor shear wave elastography Non-mass lesions Stiff rim sign Ultrasound Diagnosis
下载PDF
Shear wave elastography in hepatitis C patients before and after antiviral therapy 被引量:6
15
作者 Toshikuni Suda Osamu Okawa +4 位作者 Rion Masaoka Yoshinori Gyotoku Naohiko Tokutomi Yasumi Katayama Masaya Tamano 《World Journal of Hepatology》 CAS 2017年第1期64-68,共5页
AIMTo investigate shear wave (SW) propagation velocity in patients with untreated hepatitis C and patients with sustained virological response (SVR). METHODSA total of 136 hepatitis C patients [85 patients who had not... AIMTo investigate shear wave (SW) propagation velocity in patients with untreated hepatitis C and patients with sustained virological response (SVR). METHODSA total of 136 hepatitis C patients [85 patients who had not received antiviral therapy (na&iuml;ve group) and 51 patients who had received antiviral therapy and subsequently achieved SVR of at least 24 wk (SVR group)] and 58 healthy volunteers and outpatients without liver disease (control group) underwent evaluation of liver stiffness by SW elastography (SWE). Various parameters were evaluated in the chronic hepatitis C patients at the time of SWE. RESULTSSW propagation velocity (Vs) was 1.23 &plusmn; 0.14 m/s in the control group, 1.56 &plusmn; 0.32 m/s in the SVR group, and 1.69 &plusmn; 0.31 m/s in the na&iuml;ve group. Significant differences were seen between the control group and the SVR group (P = 0.0000) and between the SVR group and the na&iuml;ve group (P = 0.01417). All four fibrosis markers were higher in the na&iuml;ve group than in the SVR group. In the na&iuml;ve group, Vs was positively correlated with alanine aminotransferase (ALT) (r = 0.5372), &alpha; feto protein (AFP) (r = 0.4389), type IV collagen (r = 0.5883), procollagen III peptide (P-III-P) (r = 0.4140), hyaluronic acid (r = 0.4551), and Mac-2 binding protein glycosylation isomer (M2BPGi) (r = 0.6092) and negatively correlated with albumin (r = -0.4289), platelets (r = -0.5372), and prothrombin activity (r = -0.5235). On multiple regression analysis, Vs was the most strongly correlated with ALT (standard partial regression std &beta; = 0.4039, P = 0.00000). In the SVR group, Vs was positively correlated with AFP (r = 0.6977), type IV collagen (r = 0.5228), P-III-P (r = 0.5812), hyaluronic acid (r = 0.5189), and M2BPGi (r = 0.6251) and negatively correlated with albumin (r = -0.4283), platelets (r = -0.4842), and prothrombin activity (r = -0.4771). On multiple regression analysis, Vs was strongly correlated with AFP (standard partial regression std &beta; = 0.5953, P = 0.00000) and M2BPGi (standard partial regression std &beta;= 0.2969, P = 0.03363). CONCLUSIONIn hepatitis C patients, liver stiffness is higher in treatment-na&iuml;ve patients than in those showing SVR. SWE may be a predictor of hepatocarcinogenesis in SVR patients. 展开更多
关键词 HEPATOCARCINOGENESIS Sustained virological response Antiviral therapy shear wave elastography Hepatitis C
下载PDF
Differential diagnosis of different types of solid focal liver lesions using two-dimensional shear wave elastography 被引量:6
16
作者 Jia Guo Dong Jiang +4 位作者 Yi Qian Jiao Yu Yi-Jun Gu Yu-Qing Zhou Hui-Ping Zhang 《World Journal of Gastroenterology》 SCIE CAS 2022年第32期4715-4724,共10页
BACKGROUND The clinical management and prognosis differ between benign and malignant solid focal liver lesions(FLLs),as well as among different pathological types of malignant FLLs.Accurate diagnosis of the possible t... BACKGROUND The clinical management and prognosis differ between benign and malignant solid focal liver lesions(FLLs),as well as among different pathological types of malignant FLLs.Accurate diagnosis of the possible types of solid FLLs is important.Our previous study confirmed the value of shear wave elastography(SWE)using maximal elasticity(Emax)as the parameter in the differential diagnosis between benign and malignant FLLs.However,the value of SWE in the differential diagnosis among different pathological types of malignant FLLs has not been proved.AIM To explore the value of two-dimensional SWE(2D-SWE)using Emax in the differential diagnosis of FLLs,especially among different pathological types of malignant FLLs.METHODS All the patients enrolled in this study were diagnosed as benign,malignant or undetermined FLLs by conventional ultrasound.Emax of FLLs and the periphery of FLLs was measured using 2D-SWE and compared between benign and malignant FLLs or among different pathological types of malignant FLLs.RESULTS The study included 32 benign FLLs in 31 patients and 100 malignant FLLs in 96 patients,including 16 cholangiocellular carcinomas(CCCs),72 hepatocellular carcinomas(HCCs)and 12 liver metastases.Thirty-five FLLs were diagnosed as undetermined by conventional ultrasound.There were significant differences between Emax of malignant(2.21±0.57 m/s)and benign(1.59±0.37 m/s)FLLs(P=0.000),and between Emax of the periphery of malignant(1.52±0.39 m/s)and benign(1.36±0.44 m/s)FLLs(P=0.040).Emax of liver metastases(2.73±0.99 m/s)was significantly higher than that of CCCs(2.14±0.34 m/s)and HCCs(2.14±0.46 m/s)(P=0.002).The sensitivity,specificity and accuracy were 71.00%,84.38%and 74.24%respectively,using Emax>1.905 m/s(AUC 0.843)to diagnose as malignant and 23 of 35(65.74%)FLLs with undetermined diagnosis by conventional ultrasound were diagnosed correctly.CONCLUSION Malignant FLLs were stiffer than benign ones and liver metastases were stiffer than primary liver carcinomas.2D-SWE with Emax was a useful complement to conventional ultrasound for the differential diagnosis of FLLs. 展开更多
关键词 Focal liver lesions Conventional ultrasound Two-dimensional shear wave elastography Differential diagnosis
下载PDF
The utility of two-dimensional shear wave elastography and texture analysis for monitoring liver fibrosis in rat model 被引量:3
17
作者 Li-Hong Gu Guang-Xiang Gu +2 位作者 Ping Wan Feng-Hua Li Qiang Xia 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS CSCD 2021年第1期46-52,共7页
Background:Liver fibrosis is a common pathological change caused by a variety of etiologies.Early diagnosis and timely treatment can reverse or delay disease progression and improve the prognosis.This study aimed to a... Background:Liver fibrosis is a common pathological change caused by a variety of etiologies.Early diagnosis and timely treatment can reverse or delay disease progression and improve the prognosis.This study aimed to assess the potential utility of two-dimensional shear wave elastography and texture analysis in dynamic monitoring of the progression of liver fibrosis in rat model.Methods:Twenty rats were divided into control group(n=4)and experimental groups(n=4 per group)with carbon tetrachloride administration for 2,3,4,and 6 weeks.The liver stiffness measurement was performed by two-dimensional shear wave elastography,while the optimal texture analysis subsets to distinguish fibrosis stage were generated by MaZda.The results of elastography and texture analysis were validated through comparing with histopathology.Results:Liver stiffness measurement was 6.09±0.31 kPa in the control group and 7.10±0.41 kPa,7.80±0.93 kPa,8.64±0.93 kPa,9.91±1.13 kPa in the carbon tetrachloride induced groups for 2,3,4,6 weeks,respectively(P<0.05).By texture analysis,histogram and co-occurrence matrix had the most frequency texture parameters in staging liver fibrosis.Receiver operating characteristic curve of liver elasticity showed that the sensitivity and specificity were 95.0%and 92.5%to discriminate liver fibrosis and non-fibrosis,respectively.In texture analysis,five optimal parameters were selected to classify liver fibrosis and non-fibrosis.Conclusions:Two-dimensional shear wave elastography showed potential applications for noninvasive monitoring of the progression of hepatic fibrosis,even in mild fibrosis.Texture analysis can further extract and quantify the texture features in ultrasonic image,which was a supplementary to further visual information and acquired high diagnostic accuracy for severe fibrosis. 展开更多
关键词 shear wave elastography ULTRASOUND Texture analysis FIBROSIS Rat
下载PDF
Diagnostic problems in two-dimensional shear wave elastography of the liver 被引量:4
18
作者 Hiroko Naganuma Hideaki Ishida +3 位作者 Atsushi Uno Hiroshi Nagai Hidekatsu Kuroda Masahiro Ogawa 《World Journal of Radiology》 CAS 2020年第5期76-86,共11页
Two-dimensional shear wave elastography(2D-SWE)is used in the clinical setting for observation of the liver.Unfortunately,a wide spectrum of artifactual images are frequently encountered in 2D-SWE,the precise mechanis... Two-dimensional shear wave elastography(2D-SWE)is used in the clinical setting for observation of the liver.Unfortunately,a wide spectrum of artifactual images are frequently encountered in 2D-SWE,the precise mechanisms of which remain incompletely understood.This review was designed to present many of the artifactual images seen in 2D-SWE of the liver and to analyze them by computer simulation models that support clinical observations.Our computer simulations yielded the following suggestions:(1)When performing 2D-SWE in patients with chronic hepatic disease,especially liver cirrhosis,it is recommended to measure shear wave values through the least irregular hepatic surface;(2)The most useful 2D-SWE in patients with focal lesion will detect lesions that are poorly visible on B-mode ultrasound and will differentiate true tumors from pseudo-tumors(e.g.,irregular fatty change);and(3)Measurement of shear wave values in the area posterior to a focal lesion must be avoided. 展开更多
关键词 Two-dimensional shear wave elastography ULTRASOUND ARTIFACTS Liver cirrhosis Liver tumor Computer simulation model
下载PDF
Role of shear wave elastography in the evaluation of the treatment and prognosis of supraspinatus tendinitis 被引量:3
19
作者 Jie Zhou De-Bin Yang +2 位作者 Jing Wang Hui-Zhang Li Ying-Chun Wang 《World Journal of Clinical Cases》 SCIE 2020年第14期2977-2987,共11页
BACKGROUND Supraspinatus tendinitis recurs easily after treatment.One of the main reasons is the lack of objective tools for the efficacy evaluation.Shear wave elastography(SWE)can quantitatively analyze the tissue el... BACKGROUND Supraspinatus tendinitis recurs easily after treatment.One of the main reasons is the lack of objective tools for the efficacy evaluation.Shear wave elastography(SWE)can quantitatively analyze the tissue elasticity of region of interest by measuring the Young’s modulus(YM)value.AIM To explore the role of SWE in the efficacy and prognostic evaluation of supraspinatus tendinitis.METHODS Eighty-seven patients with supraspinatus tendinitis treated in Jiading District Central Hospital Affiliated Shanghai University of Medicine and Health Sciences were recruited.Another 30 healthy volunteers were enrolled as the control group.The visual analogue scale(VAS)and Constant-Murley Score(CMS)were recorded before treatment.All participants were scanned by SWE scan,and the YM value of the region of interest were recorded.Spearman correlation analysis was performed on YM values with VAS and CMS.Univariate repeated measures analysis of variance was used to calculate the changing trend of VAS,CMS and SWE under different treatment courses.After treatment,the patients were further grouped based on who achieved significantly effective and curative treatment.The patients in the continued treatment group continued to receive treatment according to the YM value,and the remaining patients who stopped receiving treatment were included in the stopped treatment group.All patients were followed up for 1 year,and the difference in recurrence rates between the continued treatment group and the stopped treatment group were compared.RESULTS The SWE images of supraspinatus muscle in healthy volunteers were mainly blue,while those of patients with supraspinatus tendinitis showed regional red and green areas.The average YM value of the supraspinatus muscle in healthy volunteers was 26.12±4.03 kPa.The average YM value of patients with supraspinatus muscle was greater than that of healthy volunteers(average YM=60.61±11.53 kPa,t=26.344,P<0.001).The YM value was positively correlated with VAS(r=0.564,P<0.001)and negatively correlated with CMS(r=-0.411,P<0.001).The changes of VAS and CMS were the most obvious in course 1 and then decreased gradually.The degree of change in YM values was similar in different courses.After a 1-year follow-up,the cumulative relapse-free rate in the continued treatment group was 91.43%,which was significantly higher than that in the stopped treatment group(64.71%,X2=7.379,P=0.007).CONCLUSION SWE can objectively indicate the severity of supraspinatus tendinitis.Using the YM value as a criterion for curative effect may reduce the recurrence rate. 展开更多
关键词 Supraspinatus tendinitis shear wave elastography Young’s modulus value Visual analog score Constant-Murley score RECURRENCE
下载PDF
Model for liver hardness using two-dimensional shear wave elastography,durometer,and preoperative biomarkers 被引量:2
20
作者 Bing-Jie Ju Ming Jin +4 位作者 Yang Tian Xiang Zhen De-Xing Kong Wei-Lin Wang Sheng Yan 《World Journal of Gastrointestinal Surgery》 SCIE 2021年第2期127-140,共14页
BACKGROUND Post-hepatectomy liver failure(PHLF)increases morbidity and mortality after liver resection for patients with advanced liver fibrosis and cirrhosis.Preoperative liver stiffness using two-dimensional shear w... BACKGROUND Post-hepatectomy liver failure(PHLF)increases morbidity and mortality after liver resection for patients with advanced liver fibrosis and cirrhosis.Preoperative liver stiffness using two-dimensional shear wave elastography(2D-SWE)is widely used to evaluate the degree of fibrosis.However,the 2D-SWE results were not accurate.A durometer measures hardness by quantifying the ability of a material to locally resist the intrusion of hard objects into its surface.However,the durometer score can only be obtained during surgery.To measure correlations among 2D-SWE,palpation by surgeons,and durometermeasured objective liver hardness and to construct a liver hardness regression model.METHODS We enrolled 74 hepatectomy patients with liver hardness in a derivation cohort.Tactile-based liver hardness scores(0-100)were determined through palpation of the liver tissue by surgeons.Additionally,liver hardness was measured using a durometer.Correlation coefficients for durometer-measured hardness and preoperative parameters were calculated.Multiple linear regression models were constructed to select the best predictive durometer scale.Receiver operating characteristic(ROC)curves and univariate and multivariate analyses were used to calculate the best model’s prediction of PHLF and risk factors for PHLF,respectively.A separate validation cohort(n=162)was used to evaluate the model.RESULTS The stiffness measured using 2D-SWE and palpation scale had good linear correlation with durometer-measured hardness(Pearson rank correlation coefficient 0.704 and 0.729,respectively,P<0.001).The best model for the durometer scale(hardness scale model)was based on stiffness,hepatitis B virus surface antigen,and albumin level and had an R2 value of 0.580.The area under the ROC for the durometer and hardness scale for PHLF prediction were 0.807(P=0.002)and 0.785(P=0.005),respectively.The optimal cutoff value of the durometer and hardness scale was 27.38(sensitivity=0.900,specificity=0.660)and 27.87(sensitivity=0.700,specificity=0.787),respectively.Patients with a hardness scale score of>27.87 were at a significantly higher risk of PHLF with hazard ratios of 7.835(P=0.015).The model’s PHLF predictive ability was confirmed in the validation cohort.CONCLUSION Liver stiffness assessed by 2D-SWE and palpation correlated well with durometer hardness values.The multiple linear regression model predicted durometer hardness values and PHLF. 展开更多
关键词 HEPATECTOMY Liver Hardness Durometer Two-dimensional shear wave elastography Post-hepatectomy liver failure Liver failure
下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部