期刊文献+
共找到4,745篇文章
< 1 2 238 >
每页显示 20 50 100
Characteristics of the electromagnetic wave propagation in magnetized plasma sheath and practical method for blackout mitigation
1
作者 吴翔 张珈珲 +1 位作者 董果香 石磊 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第5期489-499,共11页
“Magnetic window”is considered as an effective method to solve the communication blackout issue.COMSOL software package based on the finite element method is utilized to simulate the propagation of right-handed circ... “Magnetic window”is considered as an effective method to solve the communication blackout issue.COMSOL software package based on the finite element method is utilized to simulate the propagation of right-handed circularly polarized wave in the magnetized plasma sheath.We assume a double Gaussian model of electron density and an exponential attenuation model of magnetic field.The propagation characteristics of right-handed circularly polarized wave are analyzed by the observation of the reflected,transmitted and loss coefficient.The numerical results show that the propagation of right-handed circularly polarized wave in the magnetized plasma sheath varies for different incident angles,collision frequencies,non-uniform magnetic fields and non-uniform plasma densities.We notice that reducing the wave frequency can meet the propagation conditions of whistle mode in the weak magnetized plasma sheath.And the transmittance of whistle mode is less affected by the variation of the electron density and the collision frequency.It can be used as a communication window. 展开更多
关键词 magnetized plasma sheath communication blackout finite element incident angle whistler wave
下载PDF
Multi-aspect analysis of ureteral access sheath usage in retrograde intrarenal surgery: A RIRSearch group study
2
作者 Oktay Özman Hacı M.Akgül +5 位作者 Cem Başataç Önder Çınar Eyüp B.Sancak Cenk M.Yazıcı Bülent Önal Haluk Akpınar 《Asian Journal of Urology》 CSCD 2024年第1期80-85,共6页
Objective:To evaluate the effect of ureteral access sheath(UAS)use and calibration change on stone-free rate and complications of retrograde intrarenal surgery(RIRS).Methods:Data from 568 patients undergoing RIRS for ... Objective:To evaluate the effect of ureteral access sheath(UAS)use and calibration change on stone-free rate and complications of retrograde intrarenal surgery(RIRS).Methods:Data from 568 patients undergoing RIRS for kidney or upper ureteral stones were retrospectively included.Firstly,patients were compared after 1:1 propensity score matching,according to UAS usage during RIRS(UAS used[+]87 and UAS non-used[−]87 patients).Then all UAS+patients(n=481)were subdivided according to UAS calibration:9.5-11.5 Fr,10-12 Fr,11-13 Fr,and 13-15 Fr.Primary outcomes of the study were the success and complications of RIRS.Results:Stone-free rate of UAS+patients(86.2%)was significantly higher than UAS−patients(70.1%)after propensity score matching(p=0.01).Stone-free rate increased with higher caliber UAS(9.5-11.5 Fr:66.7%;10-12 Fr:87.0%;11-13 Fr:90.6%;13-15 Fr:100%;p<0.001).Postoperative complications of UAS+patients(11.5%)were significantly lower than UAS−patients(27.6%)(p=0.01).Complications(8.7%)with 9.5-11.5 Fr UAS was lower than thicker UAS(17.2%)but was not statistically significant(p=0.09).UAS usage was an independent factor predicting stone-free status or peri-and post-operative complications(odds ratio[OR]3.654,95%confidence interval[CI]1.314-10.162;OR 4.443,95%CI 1.350-14.552;OR 4.107,95%CI 1.366-12.344,respectively).Conclusion:Use of UAS in RIRS may increase stone-free rates,which also increase with higher caliber UAS.UAS usage may reduce complications;however,complications seemingly increase with higher UAS calibration. 展开更多
关键词 STONE Retrograde intrarenal surgery Ureteral access sheath UROLITHIASIS Kidney
下载PDF
Effect of a cervical collar on optic nerve sheath diameter in trauma patients
3
作者 Mümin Murat Yazici Ozcan Yavasi 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2024年第2期126-130,共5页
BACKGROUND:As advocated in advanced trauma life support and prehospital trauma life support protocols,cervical immobilization is applied until cervical spine injury is excluded.This study aimed to show the difference ... BACKGROUND:As advocated in advanced trauma life support and prehospital trauma life support protocols,cervical immobilization is applied until cervical spine injury is excluded.This study aimed to show the difference in optic nerve sheath diameter(ONSD)between patients with and without a cervical collar using computed tomography(CT).METHODS:This was a single-center,retrospective study examining trauma patients who presented to the emergency department between January 1,2021,and December 31,2021.The ONSD on brain CT of the trauma patients was measured and analyzed to determine whether there was a difference between the ONSD with and without the cervical collar.RESULTS:The study population consisted of 169 patients.On CT imaging of patients with(n=66)and without(n=103)cervical collars,the mean ONSD in the axial plane were 5.43±0.50 mm and 5.04±0.46 mm respectively for the right eye and 5.50±0.52 mm and 5.11±0.46 mm respectively for the left eye.The results revealed an association between the presence of a cervical collar and the mean ONSD,which was statistically significant(P<0.001)for both the right and left eyes.CONCLUSION:A cervical collar may be associated with increased ONSD.The effect of this increase in the ONSD on clinical outcomes needs to be investigated,and the actual need for cervical collar in the emergency department should be evaluated on a case-by-case basis. 展开更多
关键词 Optic nerve sheath diameter Computed tomography TRAUMA Emergency medicine
下载PDF
Effect of ion stress on properties of magnetized plasma sheath
4
作者 陈龙 崔作君 +4 位作者 高维富 段萍 阚子晨 檀聪琦 陈俊宇 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第2期1-12,共12页
In the plasma sheath, there is a significant gradient in ion velocity, resulting in strong stress on ions treated as a fluid. This aspect has often been neglected in previous sheath studies. This study is based on the... In the plasma sheath, there is a significant gradient in ion velocity, resulting in strong stress on ions treated as a fluid. This aspect has often been neglected in previous sheath studies. This study is based on the Braginskii plasma transport theory and establishes a 1D3V sheath fluid model that takes into account the ion stress effect. Under the assumption that ions undergo both electric and diamagnetic drift in the presheath region, self-consistent boundary conditions,including the ion Bohm velocity, are derived based on the property of the Sagdeev pseudopotential.Furthermore, assuming that the electron velocity at the wall follows a truncated Maxwell distribution, the wall floating potential is calculated, leading to a more accurate sheath thickness estimation. The results show that ion stress significantly reduces the sheath thickness, enhances ion Bohm velocity, wall floating potential, and ion flux at the wall. It hinders the acceleration of ions within the sheath, leading to notable alterations in the particle density profiles within the sheath. Further research indicates that in ion stress, bulk viscous stress has the greatest impact on sheath properties. 展开更多
关键词 magnetized plasma sheath ion stress Bohm criterion
下载PDF
Fluid-chemical modeling of the near-cathode sheath formation process in a high current broken in DC air circuit breaker
5
作者 彭世东 李静 +3 位作者 段薇 曹云东 刘树鑫 黄浩 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期523-538,共16页
When the contacts of a medium-voltage DC air circuit breaker(DCCB) are separated, the energy distribution of the arc is determined by the formation process of the near-electrode sheath. Therefore, the voltage drop thr... When the contacts of a medium-voltage DC air circuit breaker(DCCB) are separated, the energy distribution of the arc is determined by the formation process of the near-electrode sheath. Therefore, the voltage drop through the near-electrode sheath is an important means to build up the arc voltage, which directly determines the current-limiting performance of the DCCB. A numerical model to describe the near-electrode sheath formation process can provide insight into the physical mechanism of the arc formation, and thus provide a method for arc energy regulation. In this work, we establish a two-dimensional axisymmetric time-varying model of a medium-voltage DCCB arc when interrupted by high current based on a fluid-chemical model involving 16 kinds of species and 46 collision reactions. The transient distributions of electron number density, positive and negative ion number density, net space charge density, axial electric field, axial potential between electrodes, and near-cathode sheath are obtained from the numerical model. The computational results show that the electron density in the arc column increases, then decreases, and then stabilizes during the near-cathode sheath formation process, and the arc column's diameter gradually becomes wider. The 11.14 V–12.33 V drops along the17 μm space charge layer away from the cathode(65.5 k V/m–72.5 k V/m) when the current varies from 20 k A–80 k A.The homogeneous external magnetic field has little effect on the distribution of particles in the near-cathode sheath core,but the electron number density at the near-cathode sheath periphery can increase as the magnetic field increases and the homogeneous external magnetic field will lead to arc diffusion. The validity of the numerical model can be proven by comparison with the experiment. 展开更多
关键词 near-cathode sheath atmospheric pressure air arc fluid-chemical model high current DC air circuit breaker(DCCB)
下载PDF
Dengue hemorrhagic fever with rectus sheath hematoma:A case report
6
作者 Boudhayan Bhattacharjee Hardik Patel +4 位作者 Rucha Karad Vasireddy Teja Agnibho Mondal Soumendra Nath Haldar Bibhuti Saha 《Asian Pacific Journal of Tropical Medicine》 SCIE CAS 2024年第3期136-138,共3页
Rationale:Acute pain is a medical emergency that requires prompt abdominal evaluation and management.Dengue,a mosquito-borne arboviral infection,can lead to complications such as acute abdominal pain.Patient concerns:... Rationale:Acute pain is a medical emergency that requires prompt abdominal evaluation and management.Dengue,a mosquito-borne arboviral infection,can lead to complications such as acute abdominal pain.Patient concerns:A 72-year-old hypertensive female presented with high-grade intermittent fever with chills and rigors for four days.She was diagnosed with dengue fever(NS1Ag-reactive)the day before admission.A contrast-enhanced computed tomography of the abdomen showed a hematoma along the rectus sheath which was managed conservatively as per surgical opinion.Diagnosis:Dengue hemorrhagic fever with rectus sheath hematoma.Interventions:Blood transfusion and fluid therapy.Outcomes:Ten days after discharge,the patient reproted no pain in the right iliac fossa and the size of the hematoma was significantly reduced.Lessons:Although it is rarely seen as a cause of acute abdomen,complaints of adnominal pain should never be ignored in critical or convalescent phase of dengue fever.Radiological investigations should be promptly conducted as hematoma is often difficult to be diagnosed clinically.Delay in diagnosis of rectus sheath hematoma can be fatal. 展开更多
关键词 Dengue fever Rectus sheath hematoma Surgical emergency Acute appendicitis
下载PDF
Epithelioid malignant peripheral nerve sheath tumor of the bladder and concomitant urothelial carcinoma: A case report
7
作者 Sami Berk Ozden Muhammed Fatih Simsekoglu +2 位作者 Ipek Sertbudak Cetin Demirdag Iclal Gurses 《World Journal of Clinical Cases》 SCIE 2024年第3期551-559,共9页
BACKGROUND Epithelioid malignant peripheral nerve sheath tumor(EMPNST)of the bladder is a rare entity with devastating features.These tumors are thought to originate from malignant transformation of pre-existing schwa... BACKGROUND Epithelioid malignant peripheral nerve sheath tumor(EMPNST)of the bladder is a rare entity with devastating features.These tumors are thought to originate from malignant transformation of pre-existing schwannomas of pelvic autonomic nerve plexuses,and unlike the conventional malignant peripheral nerve sheath tumor(MPNST),are not associated with neurofibromatosis.The tumor has dis-tinctive morphological,immunohistochemical and molecular features.Addi-tionally,it tends to be more aggressive and have a higher mortality.This is the first case that presents with a synchronous urothelial carcinoma of the bladder and the epithelioid variant of MPNST in the literature.It’s also the second re-ported case of EMPNST originating from the bladder wall.CASE SUMMARY In this case report,we present the detailed clinical course of a 71-year-old patient with EMPNST of the bladder alongside a literature review.CONCLUSION During the management of EMPNST cases,offering aggressive treatment moda-lities to the patient,such as radical cystectomy,is appropriate for the best chance to contain the disease,regardless of the tumor stage and the extent of local disease at initial diagnosis. 展开更多
关键词 EPITHELIOID Peripheral nerve sheath tumor BLADDER Case report UROTHELIAL CYSTOPROSTATECTOMY
下载PDF
Symmetry of upper eyelid after unilateral blepharoptosis repair with minimally invasive conjoint fascial sheath suspension technique
8
作者 Yianzhu Liu Wenli Chen Xia Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第1期53-60,共8页
AIM:To investigate the symmetry of upper eyelid in patients with unilateral mild and moderate blepharoptosis who underwent unilateral minimally invasive combined fascia sheath(CFS)suspension.METHODS:A retrospective st... AIM:To investigate the symmetry of upper eyelid in patients with unilateral mild and moderate blepharoptosis who underwent unilateral minimally invasive combined fascia sheath(CFS)suspension.METHODS:A retrospective study of patients who underwent unilateral minimally invasive CFS suspension surgery between January 2018 and December 2021.Inclusion criteria included unilateral mild and moderate ptosis,good levator muscle function(>9 mm)and follow-up of at least 6mo.Pre-and post-operative symmetry was graded subjectively for marginal reflex distance 1(MRD1),tarsal platform show(TPS)and eyebrow fat span(BFS).A t-test was used to evaluate MRD1,TPS and BFS asymmetry by calculating delta values.The Bézier curve tool of the Image J software was used to extract the upper eyelid contours,where the symmetry was measured by the percentage of overlapping curvatures(POC).RESULTS:Totally 105 patients(105 eyelids)were included(mild group,n=84;moderate group,n=21).Postoperatively,all patients increased MRD1 and decreased TPS in the ptotic eye while maintaining unchanged BFS.The asymmetric delta value for MRD1 was measured to be 1.48±0.86 preoperatively,and it decreased to 0.58±0.67 postoperatively in all cases(P=0.0004).In patients with mild ptosis,the asymmetry value of TPS fell significantly from 1.15±0.62 to 0.68±0.38(P=0.0187).The symmetry of the upper eyelid contour increased in all subgroups of patients,with a POC of 59.39%±13.45%preoperatively and POC of 78.29%±13.80%postoperatively.CONCLUSION:Minimally invasive CFS suspension is proved to be an effective means of improving the symmetry of unilateral ptosis in terms of MRD1(all subgroups),POC(all subgroups)and TPS(only mild group),whereas BFS is unaffected. 展开更多
关键词 SYMMETRY unilateral blepharoptosis minimally invasive combined fascia sheath suspension
下载PDF
Failure mechanism and influencing factors of cement sheath integrity under alternating pressure 被引量:1
9
作者 Kuan-Hai Deng Nian-Tao Zhou +4 位作者 Yuan-Hua Lin Yan-Xian Wu Jie Chen Chang Shu Peng-Fei Xie 《Petroleum Science》 SCIE EI CAS CSCD 2023年第4期2413-2427,共15页
The failure of cement sheath integrity can be easily caused by alternating pressure during large-scale multistage hydraulic fracturing in shale-gas well.An elastic-plastic mechanical model of casing-cement sheath-form... The failure of cement sheath integrity can be easily caused by alternating pressure during large-scale multistage hydraulic fracturing in shale-gas well.An elastic-plastic mechanical model of casing-cement sheath-formation(CSF)system under alternating pressure is established based on the Mohr-Coulomb criterion and thick-walled cylinder theory,and it has been solved by MATLAB programming combining global optimization algorithm with Global Search.The failure mechanism of cement sheath integrity is investigated,by which it can be seen that the formation of interface debonding is mainly related to the plastic strain accumulation,and there is a risk of interface debonding under alternating pressure,once the cement sheath enters plasticity whether in shallow or deep well sections.The matching relationship between the mechanical parameters(elastic modulus and Poisson's ratio)of cement sheath and its integrity failure under alternating pressure in whole well sections is studied,by which it has been found there is a“critical range”in the Poisson's ratio of cement sheath.When the Poisson's ratio is below the“critical range”,there is a positive correlation between the yield internal pressure of cement sheath(SYP)and its elastic modulus.However,when the Poisson's ratio is above the“critical range”,there is a negative correlation.The elastic modulus of cement sheath is closely related to its Poisson's ratio,and restricts each other.Scientific and reasonable matching between mechanical parameters of cement sheath and CSF system under different working conditions can not only reduce the cost,but also protect the cement sheath integrity. 展开更多
关键词 Casing-cement sheath-formation system Mechanical model Matching relationship Cement sheath integrity Critical range Mechanical parameters
下载PDF
THM coupled analysis of cement sheath integrity considering well
10
作者 Xiao-Rong Li Chen-Wang Gu +1 位作者 Ze-Chen Ding Yong-Cun Feng 《Petroleum Science》 SCIE EI CAS CSCD 2023年第1期447-459,共13页
he cement sheath is the heart of any oil or gas well for providing zonal isolation and well integrity during the life of a well.Loads induced by well construction operations and borehole pressure and temperature chang... he cement sheath is the heart of any oil or gas well for providing zonal isolation and well integrity during the life of a well.Loads induced by well construction operations and borehole pressure and temperature changes may lead to the ultimate failure of cement sheath.This paper quantifies the potential of cement failure under mechanically and thermally induced stress during the life-of-well using a coupled thermalehydrologicalemechanical(THM)modeling approach.A staged finite-element procedure is presented considering sequential stress and displacement development during each stage of the well life,including drilling,casing,cementing,completion,production,and injection.The staged model quantifies the stress states and state variables,e.g.,plastic strain,damage,and debonding at cement/rock or cement/casing interface,in each well stage from simultaneous action of in-situ stress,pore pressure,temperature,casing pressure,and cement hardening/shrinkage.Thus,it eliminates the need to guess the initial stress and strain state before modeling a specific stage.Moreover,coupled THM capabilities of the model ensure the full consideration of the interaction between these influential factors. 展开更多
关键词 Cement sheath integrity Thermal-hydrological-mechanical Whole life cycle Cement sheath shrinkage Initial stresses
下载PDF
Modeling of magnetized collisional plasma sheath with nonextensive electron distribution and ionization source
11
作者 陈龙 杨叶慧 +5 位作者 安宇豪 段萍 孙少娟 崔作君 阚子晨 高维富 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第3期21-31,共11页
The properties of an atmospheric-pressure collisional plasma sheath with nonextensively distributed electrons and hypothetical ionization source terms are studied in this work. The Bohm criterion for the magnetized pl... The properties of an atmospheric-pressure collisional plasma sheath with nonextensively distributed electrons and hypothetical ionization source terms are studied in this work. The Bohm criterion for the magnetized plasma is extended in the presence of an ion–neutral collisional force and ionization source. The effects of electron nonextensive distribution, ionization frequency, ion–neutral collision, magnetic field angle and ion temperature on the Bohm criterion of the plasma sheath are numerically analyzed. The fluid equations are solved numerically in the plasma–wall transition region using a modified Bohm criterion as the boundary condition. The plasma sheath properties such as charged particle density, floating sheath potential and thickness are thoroughly investigated under different kinds of ion source terms, contributions of collisions, and magnetic fields. The results show that the effect of the ion source term on the properties of atmosphericpressure collisional plasma sheath is significant. As the ionization frequency increases, the Mach number of the Bohm criterion decreases and the range of possible values narrows. When the ion source is considered, the space charge density increases, the sheath potential drops more rapidly,and the sheath thickness becomes narrower. In addition, ion–neutral collision, magnetic field angle and ion temperature also significantly affect the sheath potential profile and sheath thickness. 展开更多
关键词 plasma sheath Bohm criterion NONEXTENSIVITY ionization source
下载PDF
Characteristics of the plasma sheath in helium discharge within dielectric tubes
12
作者 吴淑群 郭玥 +3 位作者 欧阳帆 周保伟 胡彪 程鹤 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第4期79-92,共14页
To understand the characteristics of the plasma sheath within small tubes,a 2D numerical model of He discharge within dielectric tubes is developed.During plasma propagation for a tube diameter of 0.05 mm,the sheath t... To understand the characteristics of the plasma sheath within small tubes,a 2D numerical model of He discharge within dielectric tubes is developed.During plasma propagation for a tube diameter of 0.05 mm,the sheath thickness in the plasma head is almost equal to the tube radius.It decreases rapidly to several micrometers at an axial distance of 0.05 mm behind the plasma head,and then slightly increases and saturates at the axial position far behind the plasma head.A plasma-gas sheath surrounding the central plasma column is observed for a tube diameter equal to or greater than 0.8 mm.It is replaced by a plasma-wall sheath for smaller tubes.With the decrease in the tube diameter,the sheath thickness far behind the plasma head decreases while the ion flux increases significantly.However,when O_(2)gas with a proportion of 2%is added,both the sheath thickness and ion flux decrease. 展开更多
关键词 plasma sheath plasma modification helium discharge ion flux plasma jet
下载PDF
Electron sheaths near a positively biased plate subjected to a weak electron beam
13
作者 刘琦 卫子安 +3 位作者 马锦秀 弋开阳 陶万 李政元 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第3期70-77,共8页
Electron sheaths have previously only been measured near a positively biased small electrode, in which a potential dip was often observed. In this paper, we present an experimental study on the electron sheath near a ... Electron sheaths have previously only been measured near a positively biased small electrode, in which a potential dip was often observed. In this paper, we present an experimental study on the electron sheath near a stainless steel plate in the presence of a weak electron beam. It is shown that the electron beam, though its density is much lower than that of the background plasma, will substantially alter the sheath structure, i.e., it causes the disappearance of the potential dip when the beam energy just exceeds the ionization potential of the neutral gas but later enhances the dip for higher energies. It is also shown that proper biases on the plate and chamber wall are the key to the formation of the electron sheath and the dip. For a fixed plate bias but with different electron beam energy, the measured thickness of the ion-free Child–Langmuir sheath agrees well with that of the theoretical model. 展开更多
关键词 electron sheath potential dip electron-beam-plasma system
下载PDF
Presheath formation and area design limit satellite-based Langmuir probes
14
作者 靳琛垚 叶孜崇 +4 位作者 孙海岗 江堤 张炜 徐国盛 王亮 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第12期1-13,共13页
In this article,the effect of the finite conductive surface area of a satellite on the use of satellite-based Langmuir probes is reviewed in light of the basic theory of asymmetric double Langmuir probes(ADLPs).Recent... In this article,the effect of the finite conductive surface area of a satellite on the use of satellite-based Langmuir probes is reviewed in light of the basic theory of asymmetric double Langmuir probes(ADLPs).Recent theoretical and experimental studies have discussed electron sheath/presheath formation and the electron Bohm criterion along with their implications for satellite-based Langmuir probes.The effects predicted by the latest theory of the electron Bohm criterion were not experimentally observed and the experimental results remain supportive of a critical area ratio(A_(L)/A_(S))_(crit)=(m_(i)/(2.3m_(e)))^(1/2)between the probe area A_(S)and the satellite area A_L as conventionally believed.A satellite-based Langmuir probe must satisfy this criterion to physically act as a single Langmuir probe.However,experimental investigations also found that high-energy electrons adversely affect(A_(L)/A_(S))_(crit)and a Langmuir probe's signal quality by giving additional electron current to A_(L).Based on these results,a number of limitations of the maximum probe area are derived when designing satellite-based Langmuir probes,with consideration of both the aim of the satellite and the plasma where the satellite-based probe works.These proposed measures are expected to only partially alleviate the effect of the inadequate satellite surface area on the application of satellite-based Langmuir probes.Using a larger satellite to carry a Langmuir probe remains the most viable means to obtain precise space plasma parameters. 展开更多
关键词 space plasmas satellite-based Langmuir probe sheath/presheath electric propulsion
下载PDF
Analysis of the Microstructure of a Failed Cement Sheath Subjected to Complex Temperature and Pressure Conditions
15
作者 Zhiqiang Wu Yi Wu +3 位作者 Renjun Xie Jin Yang Shujie Liu Qiao Deng 《Fluid Dynamics & Materials Processing》 EI 2023年第2期399-406,共8页
One of the main obstacles hindering the exploitation of high-temperature and high-pressure oil and gas is the sealing integrity of the cement sheath.Analyzing the microstructure of the cement sheath is therefore an im... One of the main obstacles hindering the exploitation of high-temperature and high-pressure oil and gas is the sealing integrity of the cement sheath.Analyzing the microstructure of the cement sheath is therefore an important task.In this study,the microstructure of the cement sheath is determined using a CT scanner under different temperature and pressure conditions.The results suggest that the major cause of micro-cracks in the cement is the increase in the casing pressure.When the micro-cracks accumulate to a certain extent,the overall structure of the cement sheath is weakened,resulting in gas channeling,which poses a direct threat to the safe production of oil and gas.A change in the casing temperature has a limited effect on the microstructure of the cement sheath. 展开更多
关键词 Cement sheath MICROSTRUCTURE experimental study mesh model CT scan
下载PDF
Study of a collisionless magnetized plasma sheath with nonextensively distributed species
16
作者 R PAUL K DEKA +4 位作者 G SHARMA R MOULICK S ADHIKARI S S KAUSIK B K SAIKIA 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第12期14-23,共10页
A weakly magnetized sheath for a collisionless, electronegative plasma comprising positive ions,electrons, and negative ions is investigated numerically using the fluid approach. The electrons are considered to be non... A weakly magnetized sheath for a collisionless, electronegative plasma comprising positive ions,electrons, and negative ions is investigated numerically using the fluid approach. The electrons are considered to be non-Maxwellian in nature and are described by Tsalli's distribution. Such electrons have a substantial effect on the sheath properties. The study also reveals that non-Maxwellian distribution is the most realistic description for negative ions in the presence of an oblique magnetic field. In addition to the negative ion temperature, the sheath potential is also affected by the nonextensive parameters. The present research finds application in the plasma processing and semiconductor industry as well as in space plasmas. 展开更多
关键词 magnetised plasma sheath electronegative plasma non-extensive distribution
下载PDF
An Investigation into the Effects of Oil-Well Cement Expansion Agent on the Integrity of Cement Sheath
17
作者 Chunqin Tan Shenglai Guo Juanjuan Huang 《Fluid Dynamics & Materials Processing》 EI 2023年第5期1291-1300,共10页
Generally,the so-called expansion agent is very effective in eliminating all the micro-annuli that exist between the casing and the cement sheath or between the cement sheath and the formation.However,this approach ca... Generally,the so-called expansion agent is very effective in eliminating all the micro-annuli that exist between the casing and the cement sheath or between the cement sheath and the formation.However,this approach can detrimentally affect the sealing ability of cement sheath if the expansion agent is used in an unreasonable way.For these reasons,in the present work,numerical simulations have been conducted to analyze the effect of elasticity modulus of cement sheath,the elasticity modulus of formation,the expansion rate of cement,the geo-stress on the micro-annulus caused by cement expansion,and the cement sheath expansion on the integrity of cement sheath and formation.The micro-annulus between the casing and the cement sheath has been found to decrease according to the ratio between the elasticity modulus of formation and the elasticity modulus of cement sheath.A positive correlation has been observed between the micro-annulus and the cement expansion ratio.The microannulus decreases as the geo-stress increases,but the effect of the geo-stress on the micro-annulus is much smaller.In conclusion,the expansion agent is suitable for the formation in which the elasticity modulus is higher than the cement sheath. 展开更多
关键词 Cement sheath expansion agent numerical simulation INTEGRITY
下载PDF
Intron Retention Fine-Tunes the Resistance of the Rice Mutant pls4 to Rice Sheath Blight(Rhizotonia solani AG I.1a)
18
作者 Shaochun Liu Jiamin Hu +4 位作者 Haohua He Junru Fu Xu Jie Dahu Zhou Haihui Fu 《Phyton-International Journal of Experimental Botany》 SCIE 2023年第7期2035-2049,共15页
OsPLS4 encodes aβ-ketoacyl carrier protein reductase(KAR).The role of OsPLS4 in rice sheath blight(Rhizoctonia solani)remains unclear.Our preliminary studies showed that premature leaf senescence mutants(pls4)were hi... OsPLS4 encodes aβ-ketoacyl carrier protein reductase(KAR).The role of OsPLS4 in rice sheath blight(Rhizoctonia solani)remains unclear.Our preliminary studies showed that premature leaf senescence mutants(pls4)were highly susceptive to sheath blight in the early stage of rice development.To explore the role of this gene in the development of rice sheath blight,the transcriptome profiles of the rice pls4 mutant and wild type were compared by RNA-seq.The results revealed 2,569 differentially expressed genes(DEGs).The down-regulated genes were significantly enriched in the defense response-related biological processes.These down-regulated genes included the chitinase genes and WRKY genes,which were significantly changed in pls4 mutants.Furthermore,467 genes induced significant alternative splicing(AS)events.Among them,intron retention(IR)affected gene expression levels and functions of the vitamin B6(VB6)metabolism pathway related to sheath blight.This result suggests that IR plays an important role in the sheath blight resistance of mutant pls4.Together,these results indicate that pls4 could be involved in the biological process of sheath blight via DEGs and the fine-tuning of IR.The present study provides a molecular basis for further investigation of the resistance of rice to sheath blight. 展开更多
关键词 Alternative splicing intron retention RNA-sequencing rice sheath blight vitamin B6 metabolism
下载PDF
Integrity and Failure Analysis of Cement Sheath Subjected to Coalbed Methane Fracturing
19
作者 Lingyun Zhao Heng Yang +3 位作者 Yuanlong Wei Yuhuan Bu Shaorui Jing Peiming Zhou 《Fluid Dynamics & Materials Processing》 EI 2023年第2期329-344,共16页
Perforation and fracturing are typically associated with the development of coalbed methane wells.As the cement sheath is prone to failure during this process,in this work,the effects of the casing pressure,elastic mo... Perforation and fracturing are typically associated with the development of coalbed methane wells.As the cement sheath is prone to failure during this process,in this work,the effects of the casing pressure,elastic modulus of the cement,elastic modulus of the formation,and casing eccentricity on the resulting stresses are analyzed in the frame of a finite element method.Subsequently,sensitivity response curves of the cement sheath stress are plotted by normalizing all factors.The results show that the maximum circumferential stress and Mises stress of the cement sheath increase with the casing internal pressure,elastic modulus of the cement and casing eccentricity.As the elastic modulus of the formation increases,the maximum circumferential stress of the cement sheath decreases,and its maximum Mises stress increases slightly.The cement sheath undergoes tensile failure during coalbed methane fracturing.The stress sensitivity of the cement sheath to the influential parameters is in the following order:casing internal pressure>elastic modulus of cement sheath>casing eccentricity>elastic modulus of formation. 展开更多
关键词 Coalbed methane fracturing finite element method cement sheath integrity sensitivity analysis failure analysis
下载PDF
Clinicopathological study of malignant peripheral nerve sheath tumors in the head and neck:Case reports and review of literature
20
作者 Long Li Xiao-Kun Ma +4 位作者 Yan Gao Dian-Can Wang Rong-Fang Dong Jing Yan Ran Zhang 《World Journal of Clinical Cases》 SCIE 2023年第25期5910-5918,共9页
BACKGROUND Malignant peripheral nerve sheath tumor(MPNST)is a rare and aggressive soft tissue sarcoma that poses a major diagnostic and therapeutic challenge.CASE SUMMARY We retrospectively reviewed patients with head... BACKGROUND Malignant peripheral nerve sheath tumor(MPNST)is a rare and aggressive soft tissue sarcoma that poses a major diagnostic and therapeutic challenge.CASE SUMMARY We retrospectively reviewed patients with head and neck MPNSTs treated in our hospital from 2000 to 2021.The clinical features,pathological manifestations,treatments,and prognoses were summarized.We also reviewed the literature,focusing on MPNST in the mandible and maxilla.The study population consisted of five women and five men aged 22–75 years(mean age,49 years).Of the 10 patients,7 were initial cases and 3 were recurrent cases.All lesions were sporadic.The most common site was the mandible.The most frequently encountered symptoms were a progressive mass and local swelling.Complete or partial loss of trimethylation at lysine 27 of histone H3(H3K27me3)was evident on staining in four of nine cases(one case was excluded due to lack of tissue for evaluation of loss of H3K27me3).The 2-and 5-year disease-specific survival rates were 86%a nd 43%,respectively.The average survival time was 64 mo.CONCLUSION MPNST is a highly malignant tumor with a poor prognosis,prone to a high risk of recurrence and distant metastasis.Complete surgical resection is the main treatment. 展开更多
关键词 Malignant peripheral nerve sheath tumor Head and neck TREATMENT INTRAOSSEOUS SURGERY Case report
下载PDF