The seismic performance of rubber concrete-layered periodic foundations are significantly influenced by their design,in which the band gaps play a paramount role.Aiming at providing better designs for these foundation...The seismic performance of rubber concrete-layered periodic foundations are significantly influenced by their design,in which the band gaps play a paramount role.Aiming at providing better designs for these foundations,this study first proposes and validates the analytical formulas to approximate the bounds of the first few band gaps.In addition,the mapping relations linking the frequencies of different band gaps are presented.Furthermore,an optimal design method for these foundations is developed,which is validated through an engineering example.It is demonstrated that ensuring the superstructure’s resonance zones are completely covered by the corresponding periodic foundation’s band gaps can achieve satisfactory vibration attenuation effects,which is a good strategy for the design of rubber concrete layered periodic foundations.展开更多
A new type of impedance-balanced ship equipment foundation structure based on the principle of impedance balancing using a“discontinuous panel-vibration isolation liquid layer-foundation structure”is proposed to sol...A new type of impedance-balanced ship equipment foundation structure based on the principle of impedance balancing using a“discontinuous panel-vibration isolation liquid layer-foundation structure”is proposed to solve the problem of poor low-frequency vibration isolation of the foundation under unbalanced excitation of shipboard equipment.Based on the finite element method,the influence of characteristic parameters of the foundation panel structure on its vibration reduction characteristics under unbalanced excitation is explored.The results show that the vibration isolation level of the impedance-balanced foundation is 10 dB higher than the traditional foundation in the low-frequency band of 10-500 Hz when subjected to combined excitation of concentrated force and moment.Increasing the thickness of the impedance-balanced foundation panel can enhance the isolation effect.Increasing the number of sub-panels can effectively reduce the vibration response of the foundation panel and enhance the isolation performance of the foundation.The connection stiffness between sub-panels has a small effect on the isolation performance of the foundation.展开更多
基金National Natural Science Foundation of China under Grant Nos.52078395 and 52178301the Open Projects Foundation of the State Key Laboratory for Health and Safety of Bridge Structures under Grant No.BHSKL19-07-GF+1 种基金the Dawn Program of Knowledge Innovation Project from the Bureau of Science and Technology of Wuhan Municipality under Grant No.2022010801020357the Science Research Foundation of Wuhan Institute of Technology under Grant No.K2021030。
文摘The seismic performance of rubber concrete-layered periodic foundations are significantly influenced by their design,in which the band gaps play a paramount role.Aiming at providing better designs for these foundations,this study first proposes and validates the analytical formulas to approximate the bounds of the first few band gaps.In addition,the mapping relations linking the frequencies of different band gaps are presented.Furthermore,an optimal design method for these foundations is developed,which is validated through an engineering example.It is demonstrated that ensuring the superstructure’s resonance zones are completely covered by the corresponding periodic foundation’s band gaps can achieve satisfactory vibration attenuation effects,which is a good strategy for the design of rubber concrete layered periodic foundations.
基金funded by the National Natural Science Foundation of China(Grant Numbers.U2006229 and 52101351)。
文摘A new type of impedance-balanced ship equipment foundation structure based on the principle of impedance balancing using a“discontinuous panel-vibration isolation liquid layer-foundation structure”is proposed to solve the problem of poor low-frequency vibration isolation of the foundation under unbalanced excitation of shipboard equipment.Based on the finite element method,the influence of characteristic parameters of the foundation panel structure on its vibration reduction characteristics under unbalanced excitation is explored.The results show that the vibration isolation level of the impedance-balanced foundation is 10 dB higher than the traditional foundation in the low-frequency band of 10-500 Hz when subjected to combined excitation of concentrated force and moment.Increasing the thickness of the impedance-balanced foundation panel can enhance the isolation effect.Increasing the number of sub-panels can effectively reduce the vibration response of the foundation panel and enhance the isolation performance of the foundation.The connection stiffness between sub-panels has a small effect on the isolation performance of the foundation.