When single phase earth fault occurs in the arc suppression coil grounding system, the amplitude of the transient capacitance current is high and decays fast, but the attenuation of the transient inductance current is...When single phase earth fault occurs in the arc suppression coil grounding system, the amplitude of the transient capacitance current is high and decays fast, but the attenuation of the transient inductance current is much slower. This paper analyses the DC component of fault branch, and has found it is much bigger than that of the normal branches in transient state. All the simulation results obtained from three compensation types, different fault time and different wave cycles show that the DC component of fault branch is much higher than that of those normal branches. These results verify the effectiveness of taking the DC component as the method of fault line selection in the arc suppression coil grounding system.展开更多
首先介绍在远距离大容量输电场合,3种基于模块化多电平换流器(modular multilevel converter,MMC)的高压直流输电(high voltage direct current,HVDC)拓扑及其处理直流故障的方法:基于半桥子模块(half bridge sub-module,HBSM)的HMMC-H...首先介绍在远距离大容量输电场合,3种基于模块化多电平换流器(modular multilevel converter,MMC)的高压直流输电(high voltage direct current,HVDC)拓扑及其处理直流故障的方法:基于半桥子模块(half bridge sub-module,HBSM)的HMMC-HVDC跳换流站交流侧断路器,基于箝位双子模块(clamp double sub-module,CDSM)的CMMCHVDC通过换流器控制实现直流侧故障自清除,以及基于电网换相换流器(line commutated converter,LCC)和MMC的混合拓扑在MMC直流出口处加装大功率二极管(LCC-D-MMC-HVDC)。然后,在由MMC-HVDC和交流线路构成的交直流并列简化系统中,基于等面积法则,对上述3种直流故障处理方法的暂态过程进行理论分析,并提出评价指标。最后通过仿真验证了分析结果。展开更多
介绍了基于直流系统电磁暂态(electro-magnetic transient in DCsystem,EMTDC)建立的直流输电控制系统,该控制系统两侧均有定电压控制器,可通过调整直流电压参考值实现直流系统的降压运行。仿真实验结果表明:该控制系统电流指令追随性好...介绍了基于直流系统电磁暂态(electro-magnetic transient in DCsystem,EMTDC)建立的直流输电控制系统,该控制系统两侧均有定电压控制器,可通过调整直流电压参考值实现直流系统的降压运行。仿真实验结果表明:该控制系统电流指令追随性好,在直流电流下降后的恢复过程中,能有效抑制直流电压和电流的波动;在逆变侧发生单相接地故障时,由于整流侧有最小触发角限制作用,在逆变侧有故障恢复启动功能,因此在故障时能保持较大的熄弧角,在故障恢复过程中有很强的协调能力和控制能力。展开更多
为解决基于模块化多电平换流器(modular multilevel converter,MMC)的柔性直流输电(high voltage direct current,HVDC)故障电流解析计算精度不足的问题,提出一种计及远端站影响的多端MMC-HVDC故障电流改进时域求解法。首先,在分析故障...为解决基于模块化多电平换流器(modular multilevel converter,MMC)的柔性直流输电(high voltage direct current,HVDC)故障电流解析计算精度不足的问题,提出一种计及远端站影响的多端MMC-HVDC故障电流改进时域求解法。首先,在分析故障后子模块电容放电路径的基础上,推导换流站等效电容值等系统参数,建立MMC-HVDC系统故障后网络等效模型。其次,将直流电网各换流站解耦,以故障后各支路电流近似解为初值,逐次修正计及远端站影响的多端MMC-HVDC线路等效电阻及等效电感,得到多端MMC-HVDC系统中各支路的故障电流值。最后,基于RT-LAB仿真平台搭建四端柔性直流电网模型,对故障电流计算值与详细电磁暂态仿真结果进行对比。结果表明,所提故障电流求解方法能够准确、有效地计算出多端MMC-HVDC短路故障后各支路电流值,最大误差小于5%。展开更多
采用架空线柔性直流输电技术进行远距离输电是大规模风电场友好型并网的有效手段。针对架空线路易发生故障的问题,采用对称双极主接线并配置直流断路器是其主要解决方案之一。该文基于双极接线方案运行方式灵活及直流断路器的故障清除能...采用架空线柔性直流输电技术进行远距离输电是大规模风电场友好型并网的有效手段。针对架空线路易发生故障的问题,采用对称双极主接线并配置直流断路器是其主要解决方案之一。该文基于双极接线方案运行方式灵活及直流断路器的故障清除能力,提出风电经架空线基于模块化多电平换流器的柔性直流输电(modular multilevel converter based high voltage direct current,MMC-HVDC)并网的直流故障穿越协调控制策略。根据非故障极的功率转带能力,将故障清除后的不平衡功率分配划分为自消纳情景和非自消纳情景。针对自消纳情景,通过合理切换双极MMC的控制模式,可在提高非故障极功率转带能力的同时自主消纳不平衡功率,进而有效降低转移功率的影响范围;针对非自消纳情景,设计考虑风机转速约束的风电场超速减载协调控制策略,优化分配各风电机组承担的减载功率,充分利用其转子动能和捕获风功率的变化实现精确减载;同时通过控制模式切换使非故障极MMC自主运行于满载状态,减小单极退出运行对受端交流系统的影响。最后,基于Matlab/Simulink仿真模型验证所提直流故障穿越协调控制策略的有效性。展开更多
直流线路故障的快速、可靠识别是基于模块化多电平换流器(modular multilevel converter,MMC)的柔性多端直流输电(multi-terminal direct current,MTDC)系统发展的关键技术之一。通过分析柔性多端直流系统线路故障后电流的暂态特征,提...直流线路故障的快速、可靠识别是基于模块化多电平换流器(modular multilevel converter,MMC)的柔性多端直流输电(multi-terminal direct current,MTDC)系统发展的关键技术之一。通过分析柔性多端直流系统线路故障后电流的暂态特征,提出了一套基于单端电流模量分析的MMC-MTDC系统直流线路故障识别方案。该方案通过对电流一模故障分量动态偏差值极值极性与大小的检测实现了直流线路故障快速定位,并利用故障后电流零模故障分量的差异,从而实现了对故障极的快速判别。在PSCAD仿真平台上搭建了双极四端MMC型柔性直流电网的模型,通过仿真算例验证了该保护在不同故障位置和过渡电阻下均能快速、可靠地检测到直流线路故障并且准确识别故障极。展开更多
文摘When single phase earth fault occurs in the arc suppression coil grounding system, the amplitude of the transient capacitance current is high and decays fast, but the attenuation of the transient inductance current is much slower. This paper analyses the DC component of fault branch, and has found it is much bigger than that of the normal branches in transient state. All the simulation results obtained from three compensation types, different fault time and different wave cycles show that the DC component of fault branch is much higher than that of those normal branches. These results verify the effectiveness of taking the DC component as the method of fault line selection in the arc suppression coil grounding system.
文摘介绍了基于直流系统电磁暂态(electro-magnetic transient in DCsystem,EMTDC)建立的直流输电控制系统,该控制系统两侧均有定电压控制器,可通过调整直流电压参考值实现直流系统的降压运行。仿真实验结果表明:该控制系统电流指令追随性好,在直流电流下降后的恢复过程中,能有效抑制直流电压和电流的波动;在逆变侧发生单相接地故障时,由于整流侧有最小触发角限制作用,在逆变侧有故障恢复启动功能,因此在故障时能保持较大的熄弧角,在故障恢复过程中有很强的协调能力和控制能力。
文摘为解决基于模块化多电平换流器(modular multilevel converter,MMC)的柔性直流输电(high voltage direct current,HVDC)故障电流解析计算精度不足的问题,提出一种计及远端站影响的多端MMC-HVDC故障电流改进时域求解法。首先,在分析故障后子模块电容放电路径的基础上,推导换流站等效电容值等系统参数,建立MMC-HVDC系统故障后网络等效模型。其次,将直流电网各换流站解耦,以故障后各支路电流近似解为初值,逐次修正计及远端站影响的多端MMC-HVDC线路等效电阻及等效电感,得到多端MMC-HVDC系统中各支路的故障电流值。最后,基于RT-LAB仿真平台搭建四端柔性直流电网模型,对故障电流计算值与详细电磁暂态仿真结果进行对比。结果表明,所提故障电流求解方法能够准确、有效地计算出多端MMC-HVDC短路故障后各支路电流值,最大误差小于5%。
文摘采用架空线柔性直流输电技术进行远距离输电是大规模风电场友好型并网的有效手段。针对架空线路易发生故障的问题,采用对称双极主接线并配置直流断路器是其主要解决方案之一。该文基于双极接线方案运行方式灵活及直流断路器的故障清除能力,提出风电经架空线基于模块化多电平换流器的柔性直流输电(modular multilevel converter based high voltage direct current,MMC-HVDC)并网的直流故障穿越协调控制策略。根据非故障极的功率转带能力,将故障清除后的不平衡功率分配划分为自消纳情景和非自消纳情景。针对自消纳情景,通过合理切换双极MMC的控制模式,可在提高非故障极功率转带能力的同时自主消纳不平衡功率,进而有效降低转移功率的影响范围;针对非自消纳情景,设计考虑风机转速约束的风电场超速减载协调控制策略,优化分配各风电机组承担的减载功率,充分利用其转子动能和捕获风功率的变化实现精确减载;同时通过控制模式切换使非故障极MMC自主运行于满载状态,减小单极退出运行对受端交流系统的影响。最后,基于Matlab/Simulink仿真模型验证所提直流故障穿越协调控制策略的有效性。
文摘直流线路故障的快速、可靠识别是基于模块化多电平换流器(modular multilevel converter,MMC)的柔性多端直流输电(multi-terminal direct current,MTDC)系统发展的关键技术之一。通过分析柔性多端直流系统线路故障后电流的暂态特征,提出了一套基于单端电流模量分析的MMC-MTDC系统直流线路故障识别方案。该方案通过对电流一模故障分量动态偏差值极值极性与大小的检测实现了直流线路故障快速定位,并利用故障后电流零模故障分量的差异,从而实现了对故障极的快速判别。在PSCAD仿真平台上搭建了双极四端MMC型柔性直流电网的模型,通过仿真算例验证了该保护在不同故障位置和过渡电阻下均能快速、可靠地检测到直流线路故障并且准确识别故障极。