An error back propagation (BP) neural network prediction model was established for the shunt current compensation in series resistance spot welding. The input variables for the neural network consist of the resistiv...An error back propagation (BP) neural network prediction model was established for the shunt current compensation in series resistance spot welding. The input variables for the neural network consist of the resistivity of the material, the thickness of workpiece and the spot spacing, and the shunt rate is outputted. A simplified calculation for the shunt rate was presented based on the feature of the constant-current resistance spot welding and the variation of the resistance in resistance spot welding process, and then the data generated by simplified calculation were used to train and adjust the neural network model. The neural network model proposed was used to predict the shunt rate in the spot welding of 20# mlid steel (in Chinese classification) (in 2. 0 mm thickness) and 10# mild steel (in 1.5 mm and 1.0 mm thickness). The maximum relative prediction errors are, respectively, 2. 83%, 1.77% and 3.67%. Shunt current compensation experiments were peoCormed based on the neural network prediction model proposed to check the diameter difference of nuggets. Experimental results show that maximum nugget diameter deviation is less than 4% for both 10# and 20# mlid steels with spot spacing of 30 mm and 50 mm.展开更多
In this paper, a new technique using a Current Shunt and a Micropotentiometer has been used to study the electrical performance of a large area multicrystalline silicon solar cell at outdoor conditions. The electrical...In this paper, a new technique using a Current Shunt and a Micropotentiometer has been used to study the electrical performance of a large area multicrystalline silicon solar cell at outdoor conditions. The electrical performance is mainly described by measuring both cell short circuit current and open circuit voltage. The measurements of this cell by using multimeters suffer from some problems because the cell has high current intensity with low output voltage. So, the solar cell short circuit current values are obtained by measuring the voltage developed across a known resistance Current Shunt. Samples of the obtained current values are accurately calibrated by using a Micropotentiometer (μpot) thermal element (TE) to validate this new measuring technique. Moreover, the solar cell open circuit voltage has been measured. Besides, the cell output power has been calculated and can be correlated with the measured incident radiation.展开更多
The temperature effects on the electrical performance of a large area multicrystalline silicon solar cell with back-contact technology have been studied in a desert area under ambient conditions using the current shun...The temperature effects on the electrical performance of a large area multicrystalline silicon solar cell with back-contact technology have been studied in a desert area under ambient conditions using the current shunt measuring technique. Therefore, most of the problems encountered with traditional measuring techniques are avoided. The temperature dependency of the current shunt from 5oC up to 50oC has been investigated. Its temperature coefficient proves to be negligible which means that the temperature dependency of the solar cell is completely independent of the current shunt. The solar module installed in a tilted position at the optimum angle of the location, has been tested in two different seasons (winter and summer). The obtained solar cell short circuit current, open circuit voltage and output power are correlated with the measured incident radiation in both seasons and all results are discussed.展开更多
A novel control strategy for three-phase shunt active power filter (SAPF) was proposed to improve its performance under non-ideal mains voltages. The approach was inspired by our finding that the classic instantaneous...A novel control strategy for three-phase shunt active power filter (SAPF) was proposed to improve its performance under non-ideal mains voltages. The approach was inspired by our finding that the classic instantaneous reactive power theory based algorithm was unsatisfactory in terms of isolating positive sequence fundamental active components exactly under non-ideal mains voltages. So, a modified ip-iq reference current calculation method was presented. With usage of the new method, not only the positive sequence but also the fundamental active current components can be accurately isolated from load current. A deadbeat closed-loop control model is built in order to eliminate both delay error and tracking error between reference voltages and compensation voltages under unbalanced and distorted mains voltages. Computer simulation results show that the proposed strategy is effective with better tracking ability and lower total harmonic distortion (THD). The strategy is also applied to a 10 kV substation with a local electrolysis manganese plant injecting a large amount of harmonics into the power system, and is proved to be more practical and efficient.展开更多
AC currents are automatically calibrated by two different thermal current converter(TCC)designs.The two designs are different in the used number of the thermal-elements(TEs).Consequently they differ in their output el...AC currents are automatically calibrated by two different thermal current converter(TCC)designs.The two designs are different in the used number of the thermal-elements(TEs).Consequently they differ in their output electro motive force(EMF).Studying the effect of changing the output EMF is done in this paper through calibrating AC currents.5 mA and 5 A are accurately calibrated at different frequencies 55 Hz,1 kHz and10 kHz by the two TCCs.A comparison is made between the results to evaluate the effect of the output EMF value on the accuracy and the uncertainty of the low and higher AC current calibration.A LabVIEW program is designed for this accurate automatic calibration to overcome the problems of the manual calibration on the thermal converters.展开更多
More and more applications of ZnO arrester in electrical system experienced more problems.One thing,that is still under some investigation,is the effect of multiple lightning strike to the performance of ZnO arrester....More and more applications of ZnO arrester in electrical system experienced more problems.One thing,that is still under some investigation,is the effect of multiple lightning strike to the performance of ZnO arrester.As we know,the design of ZnO arrester for transmission system and for distribution system differs in the point of view of the number of ZnO blocks.Transmission system,due to its higher nominal voltage than distribution system,has more numbers of ZnO blocks inside an arrester tube.In term of the current rating of an arrester,it is found that there is some different value of the current rating.The current rating of an arrester installed closer to electrical substation is higher than that of some further away from the substation.To the respond of a lightning impulse strike,the arrester will let a high value of impulse current flowing.It tends to heat the ZnO material of the arrester.If the number of impulse strike is quite high then it may give the effect to the change of the arrester performance.This condition will endanger the equipment that is protected by the arrester from lightning strikes.During this research,the scope of work is limited to making an impulse current generator toward to one having 8/20 μs wave-shape.This kind of impulse current wave-shape is the one that is used for studying the performance of ZnO block.The effect of the inductance and capacitance of the impulse current generator were also studied.A 10 fused cut out was blown by an impulse having 10321 A of 17.8/37.8 μs.A ZnO arrester block brokendown/allowed large value of current :10982 A flowing under the voltage of 10.5展开更多
This paper describes the mitigation of harmonics in source and neutral current in three phase four wire system based on 4-leg shunt active power filter under balanced and unbalanced load conditions. Particle Swarm Opt...This paper describes the mitigation of harmonics in source and neutral current in three phase four wire system based on 4-leg shunt active power filter under balanced and unbalanced load conditions. Particle Swarm Optimization (PSO) and conventional Proportional Integral (PI) controller are used as control techniques to analyze the control performance of 4-leg shunt active power filter. The synchronous reference frame (SRF) method is used to extract reference current in 4-leg shunt active filter. The Hysteresis Current Controller (HCC) is used to generate gate pulses for Voltage Source Inverter (VSI) based 4-leg shunt active power filter. The proposed PSO technique gives less percentage of Total Harmonic Distortion (THD) value in source and neutral current and settling time of the DC capacitor voltage compared to conventional PI controller technique. The model of the proposed system performance was validated using MATLAB/Simulink environment.展开更多
This research work brings out the unique predictive current control method for attaining an efficient grid connected Photo Voltaic (PV) system by Shunt Active Power Filter (SAPF) as grid connected converter. The major...This research work brings out the unique predictive current control method for attaining an efficient grid connected Photo Voltaic (PV) system by Shunt Active Power Filter (SAPF) as grid connected converter. The major objective of the research work is to address the presence of Direct Current (DC) component, frequency improvement, quicker theta response, voltage magnitude estimation in the input signal of the Phase Locked Loop (PLL) which is challenging. This work focuses on tuning the PLL block (K<sub>p</sub>, K<sub>i</sub>, K<sub>v</sub> and K<sub>o</sub>) through Artificial Bee Colony (ABC) optimization algorithm. The proposed ABC based modified three-phase PLL method is based on adding a new loop inside the PLL structure. In power converters, ABC algorithm is used to select the optimal switching states. The voltage vector which minimizes a cost optimization function is selected. Simulation is carried out for both balanced and unbalanced system and the results validate that the performance of the proposed approach is better in terms of harmonic compensation as per the IEEE standards within ±5%, power factor improvement of the system, quicker theta tracking and suppression of frequency jump with the interconnection of PV system.展开更多
基金Acknowledgements The authors would like to thank for the financial support from the National Natural Science Foundation of China through document 51275418. The authors would also like to acknowledge professor Yang Siqian for providing discussion of the results for this study.
文摘An error back propagation (BP) neural network prediction model was established for the shunt current compensation in series resistance spot welding. The input variables for the neural network consist of the resistivity of the material, the thickness of workpiece and the spot spacing, and the shunt rate is outputted. A simplified calculation for the shunt rate was presented based on the feature of the constant-current resistance spot welding and the variation of the resistance in resistance spot welding process, and then the data generated by simplified calculation were used to train and adjust the neural network model. The neural network model proposed was used to predict the shunt rate in the spot welding of 20# mlid steel (in Chinese classification) (in 2. 0 mm thickness) and 10# mild steel (in 1.5 mm and 1.0 mm thickness). The maximum relative prediction errors are, respectively, 2. 83%, 1.77% and 3.67%. Shunt current compensation experiments were peoCormed based on the neural network prediction model proposed to check the diameter difference of nuggets. Experimental results show that maximum nugget diameter deviation is less than 4% for both 10# and 20# mlid steels with spot spacing of 30 mm and 50 mm.
文摘In this paper, a new technique using a Current Shunt and a Micropotentiometer has been used to study the electrical performance of a large area multicrystalline silicon solar cell at outdoor conditions. The electrical performance is mainly described by measuring both cell short circuit current and open circuit voltage. The measurements of this cell by using multimeters suffer from some problems because the cell has high current intensity with low output voltage. So, the solar cell short circuit current values are obtained by measuring the voltage developed across a known resistance Current Shunt. Samples of the obtained current values are accurately calibrated by using a Micropotentiometer (μpot) thermal element (TE) to validate this new measuring technique. Moreover, the solar cell open circuit voltage has been measured. Besides, the cell output power has been calculated and can be correlated with the measured incident radiation.
文摘The temperature effects on the electrical performance of a large area multicrystalline silicon solar cell with back-contact technology have been studied in a desert area under ambient conditions using the current shunt measuring technique. Therefore, most of the problems encountered with traditional measuring techniques are avoided. The temperature dependency of the current shunt from 5oC up to 50oC has been investigated. Its temperature coefficient proves to be negligible which means that the temperature dependency of the solar cell is completely independent of the current shunt. The solar module installed in a tilted position at the optimum angle of the location, has been tested in two different seasons (winter and summer). The obtained solar cell short circuit current, open circuit voltage and output power are correlated with the measured incident radiation in both seasons and all results are discussed.
基金Project(JC200903180555A) supported by Shenzhen City Science and Technology Plan, China
文摘A novel control strategy for three-phase shunt active power filter (SAPF) was proposed to improve its performance under non-ideal mains voltages. The approach was inspired by our finding that the classic instantaneous reactive power theory based algorithm was unsatisfactory in terms of isolating positive sequence fundamental active components exactly under non-ideal mains voltages. So, a modified ip-iq reference current calculation method was presented. With usage of the new method, not only the positive sequence but also the fundamental active current components can be accurately isolated from load current. A deadbeat closed-loop control model is built in order to eliminate both delay error and tracking error between reference voltages and compensation voltages under unbalanced and distorted mains voltages. Computer simulation results show that the proposed strategy is effective with better tracking ability and lower total harmonic distortion (THD). The strategy is also applied to a 10 kV substation with a local electrolysis manganese plant injecting a large amount of harmonics into the power system, and is proved to be more practical and efficient.
文摘AC currents are automatically calibrated by two different thermal current converter(TCC)designs.The two designs are different in the used number of the thermal-elements(TEs).Consequently they differ in their output electro motive force(EMF).Studying the effect of changing the output EMF is done in this paper through calibrating AC currents.5 mA and 5 A are accurately calibrated at different frequencies 55 Hz,1 kHz and10 kHz by the two TCCs.A comparison is made between the results to evaluate the effect of the output EMF value on the accuracy and the uncertainty of the low and higher AC current calibration.A LabVIEW program is designed for this accurate automatic calibration to overcome the problems of the manual calibration on the thermal converters.
文摘More and more applications of ZnO arrester in electrical system experienced more problems.One thing,that is still under some investigation,is the effect of multiple lightning strike to the performance of ZnO arrester.As we know,the design of ZnO arrester for transmission system and for distribution system differs in the point of view of the number of ZnO blocks.Transmission system,due to its higher nominal voltage than distribution system,has more numbers of ZnO blocks inside an arrester tube.In term of the current rating of an arrester,it is found that there is some different value of the current rating.The current rating of an arrester installed closer to electrical substation is higher than that of some further away from the substation.To the respond of a lightning impulse strike,the arrester will let a high value of impulse current flowing.It tends to heat the ZnO material of the arrester.If the number of impulse strike is quite high then it may give the effect to the change of the arrester performance.This condition will endanger the equipment that is protected by the arrester from lightning strikes.During this research,the scope of work is limited to making an impulse current generator toward to one having 8/20 μs wave-shape.This kind of impulse current wave-shape is the one that is used for studying the performance of ZnO block.The effect of the inductance and capacitance of the impulse current generator were also studied.A 10 fused cut out was blown by an impulse having 10321 A of 17.8/37.8 μs.A ZnO arrester block brokendown/allowed large value of current :10982 A flowing under the voltage of 10.5
文摘This paper describes the mitigation of harmonics in source and neutral current in three phase four wire system based on 4-leg shunt active power filter under balanced and unbalanced load conditions. Particle Swarm Optimization (PSO) and conventional Proportional Integral (PI) controller are used as control techniques to analyze the control performance of 4-leg shunt active power filter. The synchronous reference frame (SRF) method is used to extract reference current in 4-leg shunt active filter. The Hysteresis Current Controller (HCC) is used to generate gate pulses for Voltage Source Inverter (VSI) based 4-leg shunt active power filter. The proposed PSO technique gives less percentage of Total Harmonic Distortion (THD) value in source and neutral current and settling time of the DC capacitor voltage compared to conventional PI controller technique. The model of the proposed system performance was validated using MATLAB/Simulink environment.
文摘This research work brings out the unique predictive current control method for attaining an efficient grid connected Photo Voltaic (PV) system by Shunt Active Power Filter (SAPF) as grid connected converter. The major objective of the research work is to address the presence of Direct Current (DC) component, frequency improvement, quicker theta response, voltage magnitude estimation in the input signal of the Phase Locked Loop (PLL) which is challenging. This work focuses on tuning the PLL block (K<sub>p</sub>, K<sub>i</sub>, K<sub>v</sub> and K<sub>o</sub>) through Artificial Bee Colony (ABC) optimization algorithm. The proposed ABC based modified three-phase PLL method is based on adding a new loop inside the PLL structure. In power converters, ABC algorithm is used to select the optimal switching states. The voltage vector which minimizes a cost optimization function is selected. Simulation is carried out for both balanced and unbalanced system and the results validate that the performance of the proposed approach is better in terms of harmonic compensation as per the IEEE standards within ±5%, power factor improvement of the system, quicker theta tracking and suppression of frequency jump with the interconnection of PV system.