This study unfolds an innovative approach aiming to address the critical role of building design in global energy consumption, focusing on optimizing the Window-to-Wall Ratio (WWR), since buildings account for approxi...This study unfolds an innovative approach aiming to address the critical role of building design in global energy consumption, focusing on optimizing the Window-to-Wall Ratio (WWR), since buildings account for approximately 30% of total energy consumed worldwide. The greatest contributors to energy expenditure in buildings are internal artificial lighting and heating and cooling systems. The WWR, determined by the proportion of the building’s glazed area to its wall area, is a significant factor influencing energy efficiency and minimizing energy load. This study introduces the development of a semi-automated computer model designed to offer a real-time, interactive simulation environment, fostering improving communication and engagement between designers and owners. The said model serves to optimize both the WWR and building orientation to align with occupants’ needs and expectations, subsequently reducing annual energy consumption and enhancing the overall building energy performance. The integrated model incorporates Building Information Modeling (BIM), Virtual Reality (VR), and Energy Analysis tools deployed at the conceptual design stage, allowing for the amalgamation of owners’ inputs in the design process and facilitating the creation of more realistic and effective design strategies.展开更多
The results of quantitative analysis of fracture orientation distribution according to the pair of stereonet windows among 05 different survey sites along the segment Tien Yen-Mui Chua, belong to Cao Bang-Tien Yen fau...The results of quantitative analysis of fracture orientation distribution according to the pair of stereonet windows among 05 different survey sites along the segment Tien Yen-Mui Chua, belong to Cao Bang-Tien Yen fault zone, Quang Ninh province, Viet Nam showed that, the correlation values are over 0.80 corresponding to 50%, over 0.75 corresponding to 30% and over 0.65 corresponding to 20%. These values are quite consistent with over 60% of the fracture number in the direction of NW-SE. Especially, the compatibility is clearly reflected in the determination of the frequency of fracture measurements within the division intervals of 20 degrees for dip direction and 10 degrees for dip angle at 05 different survey sites.展开更多
该软件提供了对单晶体取向的快速分析方法。对于背射劳厄法、透射劳厄法和衍射仪法都适用。最后取向结果以极射赤面投影表示,可以长期保存。该软件用C语言(Microsoft C6.0)编写,在窗口环境(Microsoft Windows 3.0)下运行,有优良的用户...该软件提供了对单晶体取向的快速分析方法。对于背射劳厄法、透射劳厄法和衍射仪法都适用。最后取向结果以极射赤面投影表示,可以长期保存。该软件用C语言(Microsoft C6.0)编写,在窗口环境(Microsoft Windows 3.0)下运行,有优良的用户界面。展开更多
文摘This study unfolds an innovative approach aiming to address the critical role of building design in global energy consumption, focusing on optimizing the Window-to-Wall Ratio (WWR), since buildings account for approximately 30% of total energy consumed worldwide. The greatest contributors to energy expenditure in buildings are internal artificial lighting and heating and cooling systems. The WWR, determined by the proportion of the building’s glazed area to its wall area, is a significant factor influencing energy efficiency and minimizing energy load. This study introduces the development of a semi-automated computer model designed to offer a real-time, interactive simulation environment, fostering improving communication and engagement between designers and owners. The said model serves to optimize both the WWR and building orientation to align with occupants’ needs and expectations, subsequently reducing annual energy consumption and enhancing the overall building energy performance. The integrated model incorporates Building Information Modeling (BIM), Virtual Reality (VR), and Energy Analysis tools deployed at the conceptual design stage, allowing for the amalgamation of owners’ inputs in the design process and facilitating the creation of more realistic and effective design strategies.
文摘The results of quantitative analysis of fracture orientation distribution according to the pair of stereonet windows among 05 different survey sites along the segment Tien Yen-Mui Chua, belong to Cao Bang-Tien Yen fault zone, Quang Ninh province, Viet Nam showed that, the correlation values are over 0.80 corresponding to 50%, over 0.75 corresponding to 30% and over 0.65 corresponding to 20%. These values are quite consistent with over 60% of the fracture number in the direction of NW-SE. Especially, the compatibility is clearly reflected in the determination of the frequency of fracture measurements within the division intervals of 20 degrees for dip direction and 10 degrees for dip angle at 05 different survey sites.