In order to learn the variation laws of shear strength of side fillet weld post high temperatures, the tension tests were conducted after the double-strapped side fillet welded joints which were cooled down from diffe...In order to learn the variation laws of shear strength of side fillet weld post high temperatures, the tension tests were conducted after the double-strapped side fillet welded joints which were cooled down from different high temperatures with different cooling patterns. The tests indicate that specimens appear brittle fracture at the side fillet weld during the tension tests after cooling down. The fracture su(face is located in the welding throat. The maximum temperatures undergone and the cooling pattern are major factors influencing shear strength of side fillet welded joint post high temperatures. The shear strength reduces by 24% at most within 900 ~C. Based on the experimental results, the calculation formulas of shear strength of side fillet weld post high temperatures were proposed. Conclusions supply references for evaluation damage and reinforcement of steel structure post fire.展开更多
基金The research is supported by the China Postdoctoral Science Foundation (No. 2011M501428).
文摘In order to learn the variation laws of shear strength of side fillet weld post high temperatures, the tension tests were conducted after the double-strapped side fillet welded joints which were cooled down from different high temperatures with different cooling patterns. The tests indicate that specimens appear brittle fracture at the side fillet weld during the tension tests after cooling down. The fracture su(face is located in the welding throat. The maximum temperatures undergone and the cooling pattern are major factors influencing shear strength of side fillet welded joint post high temperatures. The shear strength reduces by 24% at most within 900 ~C. Based on the experimental results, the calculation formulas of shear strength of side fillet weld post high temperatures were proposed. Conclusions supply references for evaluation damage and reinforcement of steel structure post fire.