The energy-resolved neutron imaging spectrometer(ERNI)will be installed in 2022 according to the spectrometer construction plan of the China Spallation Neutron Source(CSNS).The instrument requires neutron detectors wi...The energy-resolved neutron imaging spectrometer(ERNI)will be installed in 2022 according to the spectrometer construction plan of the China Spallation Neutron Source(CSNS).The instrument requires neutron detectors with the coverage area of approximately 4 m^(2)in 5°-170°neutron diffraction angle.The neutron detection efficiency needs to be better than 40%at 1 A neutron wavelength.The spatial resolution should be better than 3 mm×50 mm in the horizontal and vertical directions respectively.We develop a one-dimensional scintillator neutron detector which is composed of the^(6)Li F/Zn S(Ag)scintillation screens,the wavelength-shifting fiber(WLSF)array,the silicon photomultipliers(Si PMs),and the self-designed application-specific integrated circuit(ASIC)readout electronics.The pixel size of the detector is designed as 3 mm×50 mm,and the neutron-sensitive area is 50 mm×200 mm.The performance of the detector prototype is measured using neutron beam 20#of the CSNS.The maximum counting rate of 247 k Hz,and the detection efficiency of63%at 1.59 A are obtained.The test results show that the performance of the detector fulfills the physical requirements of the ERNI under construction at the CSNS.展开更多
The BETA application-specific integrated circuit(ASIC)is a fully programmable chip designed to amplify,shape and digitize the signal of up to 64 Silicon photomultiplier(SiPM)channels,with a power consumption of approx...The BETA application-specific integrated circuit(ASIC)is a fully programmable chip designed to amplify,shape and digitize the signal of up to 64 Silicon photomultiplier(SiPM)channels,with a power consumption of approximately~1 mW/channel.Owing to its dual-path gain,the BETA chip is capable of resolving single photoelectrons(phes)with a signal-to-noise ratio(SNR)>5 while simultaneously achieving a dynamic range of~4000 phes.Thus,BETA can provide a cost-effective solution for the readout of SiPMs in space missions and other applications with a maximum rate below 10 kHz.In this study,we describe the key characteristics of the BETA ASIC and present an evaluation of the performance of its 16-channel version,which is implemented using 130 nm technology.The ASIC also contains two discriminators that can provide trigger signals with a time jitter down to 400 ps FWHM for 10 phes.The linearity error of the charge gain measurement was less than 2%for a dynamic range as large as 15 bits.展开更多
Considering the R&D for upgrading the K^(0)_(L) andμdetectors in the Belle II experiment using a scintillator and silicon pho-tomultiplier(SiPM),we designed a compact high-speed and low-noise preamplifier.The pre...Considering the R&D for upgrading the K^(0)_(L) andμdetectors in the Belle II experiment using a scintillator and silicon pho-tomultiplier(SiPM),we designed a compact high-speed and low-noise preamplifier.The preamplifier demonstrated a good gain stability,bandwidth of 426 MHz,baseline noise level ofσ≈0.6 mV,dynamic range of up to170 mV of the input signal amplitude,good time resolution of 20 ps,and it can be comprehensively applied to SiPMs.Adopting pole-zero-cancelation in the preamplifier reduces both the rise and fall times of the SiPM signal,which can significantly improve the time resolution and reduce the pile-up when using a large SiPM or an array of SiPMs.Various combinations of the preamplifier and several types of SiPMs demonstrated time resolutions better than 50 ps for most cases;when the number of detected photons was larger than 60,a time resolution of approximately 25 ps was achieved.展开更多
With the development of silicon photomultiplier(SiPM)technology,front-end electronics for SiPM signal processing have been highly sought after in various fields.A compact 64-channel front-end electronics(FEE)system ac...With the development of silicon photomultiplier(SiPM)technology,front-end electronics for SiPM signal processing have been highly sought after in various fields.A compact 64-channel front-end electronics(FEE)system achieved by fieldprogrammable gate array-based charge-to-digital converter(FPGA-QDC)technology was built and developed.The FEE consists of an analog board and FPGA board.The analog board incorporates commercial amplifiers,resistors,and capacitors.The FPGA board is composed of a low-cost FPGA.The electronics performance of the FEE was evaluated in terms of noise,linearity,and uniformity.A positron emission tomography(PET)detector with three different readout configurations was designed to validate the readout capability of the FEE for SiPM-based detectors.The PET detector was made of a 15×15 lutetium–yttrium oxyorthosilicate(LYSO)crystal array directly coupled with a SiPM array detector.The experimental results show that FEE can process dual-polarity charge signals from the SiPM detectors.In addition,it shows a good energy resolution for 511-keV gamma photons under the dual-end readout for the LYSO crystal array irradiated by a Na-22 source.Overall,the FEE based on FPGA-QDC shows promise for application in SiPM-based radiation detectors.展开更多
The coherent muon-to-electron transition(COMET)experiment is a leading experiment for the coherent conversion of μ^(-)N→e^(-)N using a high-intensity pulsed muon beamline,produced using innovative slow-extraction te...The coherent muon-to-electron transition(COMET)experiment is a leading experiment for the coherent conversion of μ^(-)N→e^(-)N using a high-intensity pulsed muon beamline,produced using innovative slow-extraction techniques.Therefore,it is critical to measure the muon beam characteristics.We set up a muon beam monitor(MBM),where scintillating fibers woven in a cross shape were coupled to silicon photomultipliers to measure the spatial profile and timing structure of the extracted muon beam for the COMET.The MBM detector was tested successfully with a proton beamline at the China Spallation Neutron Source and took data with good performance in the commissioning run.The development of the MBM,including its mechanical structure,electronic readout,and beam measurement results,are discussed.展开更多
The silicon photomultiplier(SiPM) with epitaxial quenching resistor(EQR) is an emerging and developing technology that has recently attracted the interest from the research community. It has characteristics of a conti...The silicon photomultiplier(SiPM) with epitaxial quenching resistor(EQR) is an emerging and developing technology that has recently attracted the interest from the research community. It has characteristics of a continuous low-resistance cap layer and integrated quenching resisters in epitaxial silicon layer, which makes it possible to increase microcell density or reduce microcell size, thus obtaining large dynamic range and high photon detection efficiency(PDE) simultaneously. Results published show that the EQR SiPM with N-on-P diode configuration had relatively low PDE at peak wavelength of 480 nm as 16%. This paper reported the EQR SiPM with P-on-N diode configuration having active area of 3 × 3 mm^2 and cell density of 10,000/mm^2(total 90,000 pixels). It was characterized with gain of 2E5, dark count rate of 7 MHz, crosstalk of 7%, dynamic range of 85,000 pixels, overall recovery time of 32 ns at room temperature and over-voltage of 3.5 V. The improved PDE at peak wavelength of 420 nm was 30%.展开更多
基金the National Natural Science Foundation of China(Grant Nos.11875273,U1832111,61964001,and 12275049)the Science Foundation of Guangdong Province of China(Grant No.2020B1515120025)+3 种基金the Neutron Physics Laboratory Funding of China Academy of Engineering Physics(Grant No.2018BC03)the General Project of Jiangxi Province Key Research and Development Program(Grant No.20212BBG73012)the Key Scientific Research Projects of Henan Higher Education Institutions(Grant Nos.23A490002 and 24A490001)the Engineering Research Center of Nuclear Technology Application(Grant No.HJSJYB2021-4)。
文摘The energy-resolved neutron imaging spectrometer(ERNI)will be installed in 2022 according to the spectrometer construction plan of the China Spallation Neutron Source(CSNS).The instrument requires neutron detectors with the coverage area of approximately 4 m^(2)in 5°-170°neutron diffraction angle.The neutron detection efficiency needs to be better than 40%at 1 A neutron wavelength.The spatial resolution should be better than 3 mm×50 mm in the horizontal and vertical directions respectively.We develop a one-dimensional scintillator neutron detector which is composed of the^(6)Li F/Zn S(Ag)scintillation screens,the wavelength-shifting fiber(WLSF)array,the silicon photomultipliers(Si PMs),and the self-designed application-specific integrated circuit(ASIC)readout electronics.The pixel size of the detector is designed as 3 mm×50 mm,and the neutron-sensitive area is 50 mm×200 mm.The performance of the detector prototype is measured using neutron beam 20#of the CSNS.The maximum counting rate of 247 k Hz,and the detection efficiency of63%at 1.59 A are obtained.The test results show that the performance of the detector fulfills the physical requirements of the ERNI under construction at the CSNS.
基金support from Grant PID2020-116075GB-C21funded by MCIN/AEI/10.13039/501100011033+1 种基金by“ERDF A way of making Europe”under Grant PID2020-116075GB-C21They also acknowledge financial support from the State Agency for Research of the Spanish Ministry of Science and Innovation through the“Unit of Excellence Maria de Maeztu 2020-2023”award to the Institute of Cosmos Sciences(CEX2019-000918-M)。
文摘The BETA application-specific integrated circuit(ASIC)is a fully programmable chip designed to amplify,shape and digitize the signal of up to 64 Silicon photomultiplier(SiPM)channels,with a power consumption of approximately~1 mW/channel.Owing to its dual-path gain,the BETA chip is capable of resolving single photoelectrons(phes)with a signal-to-noise ratio(SNR)>5 while simultaneously achieving a dynamic range of~4000 phes.Thus,BETA can provide a cost-effective solution for the readout of SiPMs in space missions and other applications with a maximum rate below 10 kHz.In this study,we describe the key characteristics of the BETA ASIC and present an evaluation of the performance of its 16-channel version,which is implemented using 130 nm technology.The ASIC also contains two discriminators that can provide trigger signals with a time jitter down to 400 ps FWHM for 10 phes.The linearity error of the charge gain measurement was less than 2%for a dynamic range as large as 15 bits.
基金This work was partially supported by the National Key R&D Program of China(No.2022YFA1601903)the National Natural Science Foundation of China(Nos.11925502,11961141003,and 12175041)the Strategic Priority Research Program of the CAS(No.XDB34030000).
文摘Considering the R&D for upgrading the K^(0)_(L) andμdetectors in the Belle II experiment using a scintillator and silicon pho-tomultiplier(SiPM),we designed a compact high-speed and low-noise preamplifier.The preamplifier demonstrated a good gain stability,bandwidth of 426 MHz,baseline noise level ofσ≈0.6 mV,dynamic range of up to170 mV of the input signal amplitude,good time resolution of 20 ps,and it can be comprehensively applied to SiPMs.Adopting pole-zero-cancelation in the preamplifier reduces both the rise and fall times of the SiPM signal,which can significantly improve the time resolution and reduce the pile-up when using a large SiPM or an array of SiPMs.Various combinations of the preamplifier and several types of SiPMs demonstrated time resolutions better than 50 ps for most cases;when the number of detected photons was larger than 60,a time resolution of approximately 25 ps was achieved.
基金supported by the Natural Science Foundation of Shandong Province (No. ZR2022QA039)the Program of Qilu Young Scholars of Shandong University
文摘With the development of silicon photomultiplier(SiPM)technology,front-end electronics for SiPM signal processing have been highly sought after in various fields.A compact 64-channel front-end electronics(FEE)system achieved by fieldprogrammable gate array-based charge-to-digital converter(FPGA-QDC)technology was built and developed.The FEE consists of an analog board and FPGA board.The analog board incorporates commercial amplifiers,resistors,and capacitors.The FPGA board is composed of a low-cost FPGA.The electronics performance of the FEE was evaluated in terms of noise,linearity,and uniformity.A positron emission tomography(PET)detector with three different readout configurations was designed to validate the readout capability of the FEE for SiPM-based detectors.The PET detector was made of a 15×15 lutetium–yttrium oxyorthosilicate(LYSO)crystal array directly coupled with a SiPM array detector.The experimental results show that FEE can process dual-polarity charge signals from the SiPM detectors.In addition,it shows a good energy resolution for 511-keV gamma photons under the dual-end readout for the LYSO crystal array irradiated by a Na-22 source.Overall,the FEE based on FPGA-QDC shows promise for application in SiPM-based radiation detectors.
文摘硅光电倍增管(Si PM)是一种新型的光电探测器件,具有增益高、灵敏度高、偏置电压低、对磁场不敏感、结构紧凑等特点。研究并设计了硅光电倍增管(Si PM)的适配电路,包括电源电路及跨阻放大电路。应用仿真软件对设计的电路进行仿真,并对电路的结构参数进行了优化。最后,制作了适配电路。测试结果表明,该适配电路对频率100 k Hz的光信号有较好的输出响应,输出幅值达到伏级,满足设计要求。
基金supported in part by Fundamental Research Funds for the Central Universities(23xkjc017)at Sun Yat-sen Universitythe National Natural Science Foundation of China(No.12075326)JSPS KAKENHI(No.22H00139)。
文摘The coherent muon-to-electron transition(COMET)experiment is a leading experiment for the coherent conversion of μ^(-)N→e^(-)N using a high-intensity pulsed muon beamline,produced using innovative slow-extraction techniques.Therefore,it is critical to measure the muon beam characteristics.We set up a muon beam monitor(MBM),where scintillating fibers woven in a cross shape were coupled to silicon photomultipliers to measure the spatial profile and timing structure of the extracted muon beam for the COMET.The MBM detector was tested successfully with a proton beamline at the China Spallation Neutron Source and took data with good performance in the commissioning run.The development of the MBM,including its mechanical structure,electronic readout,and beam measurement results,are discussed.
基金supported by the National Natural Science Foundation of China(Nos.61534005,11475025 and 11375029)
文摘The silicon photomultiplier(SiPM) with epitaxial quenching resistor(EQR) is an emerging and developing technology that has recently attracted the interest from the research community. It has characteristics of a continuous low-resistance cap layer and integrated quenching resisters in epitaxial silicon layer, which makes it possible to increase microcell density or reduce microcell size, thus obtaining large dynamic range and high photon detection efficiency(PDE) simultaneously. Results published show that the EQR SiPM with N-on-P diode configuration had relatively low PDE at peak wavelength of 480 nm as 16%. This paper reported the EQR SiPM with P-on-N diode configuration having active area of 3 × 3 mm^2 and cell density of 10,000/mm^2(total 90,000 pixels). It was characterized with gain of 2E5, dark count rate of 7 MHz, crosstalk of 7%, dynamic range of 85,000 pixels, overall recovery time of 32 ns at room temperature and over-voltage of 3.5 V. The improved PDE at peak wavelength of 420 nm was 30%.