An electron beam probe(EBP) is a detector which makes use of a low-intensity and low-energy electron beam to measure the transverse profile, bunch shape, beam neutralization and beam wake field of an intense beam wi...An electron beam probe(EBP) is a detector which makes use of a low-intensity and low-energy electron beam to measure the transverse profile, bunch shape, beam neutralization and beam wake field of an intense beam with small dimensions. While it can be applied to many aspects, we limit our analysis to beam distribution reconstruction.This kind of detector is almost non-interceptive for all of the beam and does not disturb the machine environment.In this paper, we present the theoretical aspects behind this technique for beam distribution measurement and some simulation results of the detector involved. First, a method to obtain a parallel electron beam is introduced and a simulation code is developed. An EBP as a profile monitor for dense beams is then simulated using the fast scan method for various target beam profiles, including KV distribution, waterbag distribution, parabolic distribution,Gaussian distribution and halo distribution. Profile reconstruction from the deflected electron beam trajectory is implemented and compared with the actual profile, and the expected agreement is achieved. Furthermore, as well as fast scan, a slow scan, i.e. step-by-step scan, is considered, which lowers the requirement for hardware, i.e. Radio Frequency deflector. We calculate the three-dimensional electric field of a Gaussian distribution and simulate the electron motion in this field. In addition, a fast scan along the target beam direction and slow scan across the beam are also presented, and can provide a measurement of longitudinal distribution as well as transverse profile simultaneously. As an example, simulation results for the China Accelerator Driven Sub-critical System(CADS) and High Intensity Heavy Ion Accelerator Facility(HIAF) are given. Finally, a potential system design for an EBP is described.展开更多
Although emission spectral tomography (EST) combines emission spectral measurement with optical computed tomography (OCT), it is difficult to gain transient emission data from a large number of views, therefore, h...Although emission spectral tomography (EST) combines emission spectral measurement with optical computed tomography (OCT), it is difficult to gain transient emission data from a large number of views, therefore, high precision OCT algorithms with few views ought to be studied for EST application. To improve the reconstruction precision in the case of few views, a new computed tomography reconstruction algorithm based on multipurpose optimal criterion and simulated annealing theory (multi-criterion simulated annealing reconstruction technique, MCSART) is proposed. This algorithm can suffice criterion of least squares, criterion of most uniformity, and criterion of most smoothness synchronously. We can get global optimal solution by MCSART algorithm with simulated annealing theory. The simulating experiment result shows that this algorithm is superior to the traditional algorithms under various noises.展开更多
文摘An electron beam probe(EBP) is a detector which makes use of a low-intensity and low-energy electron beam to measure the transverse profile, bunch shape, beam neutralization and beam wake field of an intense beam with small dimensions. While it can be applied to many aspects, we limit our analysis to beam distribution reconstruction.This kind of detector is almost non-interceptive for all of the beam and does not disturb the machine environment.In this paper, we present the theoretical aspects behind this technique for beam distribution measurement and some simulation results of the detector involved. First, a method to obtain a parallel electron beam is introduced and a simulation code is developed. An EBP as a profile monitor for dense beams is then simulated using the fast scan method for various target beam profiles, including KV distribution, waterbag distribution, parabolic distribution,Gaussian distribution and halo distribution. Profile reconstruction from the deflected electron beam trajectory is implemented and compared with the actual profile, and the expected agreement is achieved. Furthermore, as well as fast scan, a slow scan, i.e. step-by-step scan, is considered, which lowers the requirement for hardware, i.e. Radio Frequency deflector. We calculate the three-dimensional electric field of a Gaussian distribution and simulate the electron motion in this field. In addition, a fast scan along the target beam direction and slow scan across the beam are also presented, and can provide a measurement of longitudinal distribution as well as transverse profile simultaneously. As an example, simulation results for the China Accelerator Driven Sub-critical System(CADS) and High Intensity Heavy Ion Accelerator Facility(HIAF) are given. Finally, a potential system design for an EBP is described.
基金This work was supported by the Chinese Natural Science Foundation of China(No.60577016)the Foundation(No. 0512034)of Jiangxi Natural Science+1 种基金the Science and Technology Program(No. 2006-164)of Jiangxi Provincial Department of Educationthe Program(No.2005-314)of Key Laboratory of Nondestructive Testing Technology,Ministry of Education.
文摘Although emission spectral tomography (EST) combines emission spectral measurement with optical computed tomography (OCT), it is difficult to gain transient emission data from a large number of views, therefore, high precision OCT algorithms with few views ought to be studied for EST application. To improve the reconstruction precision in the case of few views, a new computed tomography reconstruction algorithm based on multipurpose optimal criterion and simulated annealing theory (multi-criterion simulated annealing reconstruction technique, MCSART) is proposed. This algorithm can suffice criterion of least squares, criterion of most uniformity, and criterion of most smoothness synchronously. We can get global optimal solution by MCSART algorithm with simulated annealing theory. The simulating experiment result shows that this algorithm is superior to the traditional algorithms under various noises.