期刊文献+
共找到71篇文章
< 1 2 4 >
每页显示 20 50 100
Micro-Computed Tomography Applications in Dentistry
1
作者 Ahmad Assari Maha Al Bukairi Reema Al Saif 《Open Journal of Stomatology》 2024年第1期32-41,共10页
Micro-computed tomography (MCT) encompasses two primary scanning options: ex-vivo and in-vivo imaging. Ex-vivo scanning involves the examination of extracted teeth or dental specimens, allowing for detailed analyses o... Micro-computed tomography (MCT) encompasses two primary scanning options: ex-vivo and in-vivo imaging. Ex-vivo scanning involves the examination of extracted teeth or dental specimens, allowing for detailed analyses of the microarchitecture of mineralized tissue. By analyzing the microarchitecture of dental tissues, MCT can provide valuable information about bone density, porosity, and microstructural changes, contributing to a better understanding of disease progression and treatment outcomes. Moreover, MCT facilitates the quantification of dental parameters, such as bone volume, trabecular thickness, and connectivity density, which are crucial for evaluating the efficacy of dental interventions. This present study aims to comprehensively review and explore the applications of MCT in dentistry and highlight its potential in advancing research and clinical practice. The results depicted that the quantitative approach of MCT enhances the precision and reliability of dental research. Researchers and clinicians can make evidence-based decisions regarding treatment strategies and patient management, relying on quantifiable data provided by MCT. The applications of MCT in dentistry extend beyond research, with potential clinical implications in fields such as dental implantology and endodontics. MCT is expected to play an increasingly significant role in enhancing our understanding of dental pathologies, improving treatment outcomes, and ultimately, benefiting patient care in the field of dentistry. 展开更多
关键词 Clinical Practice DENTISTRY Ex-Vivo Scanning micro-computed Tomography
下载PDF
Phase behavior of gas condensate in porous media using real-time computed tomography scanning
2
作者 Wen-Long Jing Lei Zhang +5 位作者 Ai-Fen Li Jun-Jie Zhong Hai Sun Yong-Fei Yang Yu-Long Cheng Jun Yao 《Petroleum Science》 SCIE EI CAS CSCD 2024年第2期1032-1043,共12页
The phase behavior of gas condensate in reservoir formations differs from that in pressure-volume-temperature(PVT)cells because it is influenced by porous media in the reservoir formations.Sandstone was used as a samp... The phase behavior of gas condensate in reservoir formations differs from that in pressure-volume-temperature(PVT)cells because it is influenced by porous media in the reservoir formations.Sandstone was used as a sample to investigate the influence of porous media on the phase behavior of the gas condensate.The pore structure was first analyzed using computed tomography(CT)scanning,digital core technology,and a pore network model.The sandstone core sample was then saturated with gas condensate for the pressure depletion experiment.After each pressure-depletion state was stable,realtime CT scanning was performed on the sample.The scanning results of the sample were reconstructed into three-dimensional grayscale images,and the gas condensate and condensate liquid were segmented based on gray value discrepancy to dynamically characterize the phase behavior of the gas condensate in porous media.Pore network models of the condensate liquid ganglia under different pressures were built to calculate the characteristic parameters,including the average radius,coordination number,and tortuosity,and to analyze the changing mechanism caused by the phase behavior change of the gas condensate.Four types of condensate liquid(clustered,branched,membranous,and droplet ganglia)were then classified by shape factor and Euler number to investigate their morphological changes dynamically and elaborately.The results show that the dew point pressure of the gas condensate in porous media is 12.7 MPa,which is 0.7 MPa higher than 12.0 MPa in PVT cells.The average radius,volume,and coordination number of the condensate liquid ganglia increased when the system pressure was between the dew point pressure(12.7 MPa)and the pressure for the maximum liquid dropout,Pmax(10.0 MPa),and decreased when it was below Pmax.The volume proportion of clustered ganglia was the highest,followed by branched,membranous,and droplet ganglia.This study provides crucial experimental evidence for the phase behavior changing process of gas condensate in porous media during the depletion production of gas condensate reservoirs. 展开更多
关键词 Gas condensate Pressure depletion Real-time micro-computed tomography scanning Distribution of condensate liquid
下载PDF
Low-fat microwaved peanut snacks production:Effect of defatting treatment on structural characteristics,texture,color,and nutrition
3
作者 Bo Jiao Xin Guo +6 位作者 Yiying Chen Shah Faisal Wenchao Liu Xiaojie Ma Bicong Wu Guangyue Ren Qiang Wang 《Journal of Integrative Agriculture》 SCIE CAS CSCD 2024年第7期2491-2502,共12页
This study develops low-fat microwaved peanut snacks(LMPS)using partially defatted peanuts(PDP)with different defatting ratios,catering to people’s pursuit of healthy,low-fat cuisine.The effects of defatting treatmen... This study develops low-fat microwaved peanut snacks(LMPS)using partially defatted peanuts(PDP)with different defatting ratios,catering to people’s pursuit of healthy,low-fat cuisine.The effects of defatting treatment on the structural characteristics,texture,color,and nutrient composition of LMPS were comprehensively explored.The structural characteristics of LMPS were characterized using X-ray micro-computed tomography(Micro-CT)and scanning electron microscope(SEM).The results demonstrated that the porosity,pore number,pore volume,brightness,brittleness,protein content,and total sugar content of LMPS all significantly increased(P<0.05)with the increase in the defatting ratio.At the micro level,porous structure,cell wall rupture,and loss of intracellular material could be observed in LMPS after defatting treatments.LMPS made from PDP with a defatting ratio of 64.44%had the highest internal pore structural parameters(porosity 59%,pore number 85.3×10^(5),pore volume 68.23 mm3),the brightest color(L^(*) 78.39±0.39),the best brittleness(3.64±0.21)mm^(–1)),and the best nutrition(high protein content,(34.02±0.38)%;high total sugar content,(17.45±0.59)%;low-fat content,(27.58±0.85)%).The study provides a theoretical basis for the quality improvement of LMPS. 展开更多
关键词 low-fat microwaved peanut snacks(LMPS) X-ray micro-computed tomography(Micro-CT) porosity TEXTURE COLOR NUTRITION
下载PDF
Investigating microstructure of Longmaxi shale in Shizhu area,Sichuan Basin, by optical microscopy, scanning electron microscopy and micro-computed tomography 被引量:8
4
作者 Yu Wang Li-Hua Wang +3 位作者 Jian-Qiang Wang Zheng Jiang Chan Jin Yan-Fei Wang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第11期226-235,共10页
Microstructure of shale formation is the key to understanding its petrophysical and chemical properties.Optical microscopy, scanning electron microscopy and micro-computed tomography(μ-CT) have been combined for char... Microstructure of shale formation is the key to understanding its petrophysical and chemical properties.Optical microscopy, scanning electron microscopy and micro-computed tomography(μ-CT) have been combined for characterization of microstructure of Longmaxi(LMX)shale from Shizhu area, Sichan Basin. The results indicate that laminated LMX shale consists of mineral matrix-rich layers and organic matter(OM)-rich layers at micrometer scale in two and three dimensions. Mineral matrix layers,mainly consisting of interparticle pores and intraplatelet pores, are approximately parallel to the bedding plane.Pyrite-rich layer, mainly containing intercrystalline pores,shows a strong preferred orientation parallel to the bedding plane. OM-rich layer, mainly containing OM pores, seems to be discontinuous. In addition, intercrystalline pores are enriched in some layers, while OM pores are distributed irregularly in matrix layers. This vertical heterogeneity of pore microscopic structures in LMX shale is of great importance to understand its petrophysical and chemical properties. 展开更多
关键词 micro-computed TOMOGRAPHY PORE MICROSTRUCTURE HETEROGENEITY Matrix layers Longmaxi SHALE
下载PDF
Comparative study of chitosan/fibroin–hydroxyapatite and collagen membranes for guided bone regeneration in rat calvarial defects: micro-computed tomography analysis 被引量:15
5
作者 Jae Min Song Sang Hun Shin +4 位作者 Yong Deok Kim Jae Yeol Lee Young Jae Baek Sang Yong Yoon Hong Sung Kim 《International Journal of Oral Science》 SCIE CAS CSCD 2014年第2期87-93,共7页
This study aimed to utilize micro-computed tomography (micro-CT) analysis to compare new bone formation in rat calvarial defects using chitosan/fibroin-hydroxyapatite (CFB-HAP) or collagen (Bio-Gide) membranes. ... This study aimed to utilize micro-computed tomography (micro-CT) analysis to compare new bone formation in rat calvarial defects using chitosan/fibroin-hydroxyapatite (CFB-HAP) or collagen (Bio-Gide) membranes. Fifty-four (54) rats were studied. A circular bony defect (8 mm diameter) was formed in the centre of the calvaria using a trephine bur. The CFB-HAP membrane was prepared by thermally induced phase separation. In the experimental group (n= 18), the CFB-HAP membrane was used to cover the bony defect, and in the control group (n= 18), a resorbable collagen membrane (Bio-Gide) was used. In the negative control group (n= 18), no membrane was used. In each group, six animals were euthanized at 2, 4 and 8 weeks after surgery. The specimens were then analysed using micro-CT. There were significant differences in bone volume (BV) and bone mineral density (BMD) (P〈O.05) between the negative control group and the membrane groups. However, there were no significant differences between the CFB-HAP group and the collagen group. We concluded that the CFB-HAP membrane has significant potential as a guided bone regeneration (GBR) membrane. 展开更多
关键词 chitosan/fibroin-hydroxyapatite collagen membrane guided bone regeneration micro-computed tomography rat calva rial defect
下载PDF
Development of single-chip fuzzy controller based on FFSI in binary 被引量:1
6
作者 张吉礼 欧进萍 孙德兴 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2003年第3期269-274,共6页
Length and concise structure of fuzzy logic reasoning program and its real-time reasoning characteris-tic have their effect on the performance of a digital single-chip fuzzy controller. The control effect of a digital... Length and concise structure of fuzzy logic reasoning program and its real-time reasoning characteris-tic have their effect on the performance of a digital single-chip fuzzy controller. The control effect of a digitalfuzzy controller based on looking up fuzzy control responding table is only relative to the table and not relative tothe fuzzy control rules in the practical control process. Aiming at above problem and having combined fuzzy log-ic reasoning with digital operational characteristics of a single-chip microcomputer, functioning-fuzzy-subset in-ference (FFSI) in binary, in which triangle membership functions of error and error-in-change are all represen-ted in binary and singleton membership functions of control variable is binary too, has been introduced. The cir-cuit principle plans of a single-chip fuzzy controller have been introduced for development of its hardware, andthe primary program structure, fuzzy logic reasoning subroutine, serial communication subroutine with PC andreliability design of the fuzzy controller are all discussed in detail. The control of indoor temperature by a fuzzycontroller has been conducted using a testing-room thermodynamic system. Research results show that the FFSIin binary can exercise a concise fuzzy control in a single-chip fuzzy controller, and the fuzzy controller is there-fore reliable and possesses a high performance-price ratio. 展开更多
关键词 functioning-fuzzy-subset inference single-chip fuzzy controller testing-room thermodynamic system indoor temperature experiment
下载PDF
Nondestructive Skeletal Imaging of Hyla suweonensis Using Micro-Computed Tomography 被引量:1
7
作者 Eunbin KIM Hacheol SUNG +3 位作者 Donghyun LEE Geunjoong KIM Dongha NAM Etmgsam KIM 《Asian Herpetological Research》 SCIE CSCD 2017年第4期235-243,共9页
We successfully obtained 3D skeletal images of Hyla suweonensis, employing a nondestructive method by applying appropriate anesthesia and limiting the radiation dose. H. suweonensis is a tree frog endemic to Korea and... We successfully obtained 3D skeletal images of Hyla suweonensis, employing a nondestructive method by applying appropriate anesthesia and limiting the radiation dose. H. suweonensis is a tree frog endemic to Korea and is on the list of endangered species. Previous studies have employed caliper-based measurements and two-dimensional (2D) X-ray imaging for anatomical analyses of the skeletal system or bone types of H. suweonensis. In this work we reconstructed three-dimensional (3D) skeletal images of H. suweonensis, utilizing a nondestructive micro-computed tomography (micro-CT) with a short scan and low radiation dose (i.e. 4 min and 0.16 Gy). Importantly, our approach can be applied to the imaging of 3D skeletal systems of other endangered frog species, allowing both versatile and high contrast images of anatomical structures without causing any significant damages to the living animal. 展开更多
关键词 Hyla suweonensis micro-computed tomography 3D skeletal structure Nondestructive imaging Endangered species Radiation dose.
下载PDF
Gas concentration monitoring system for small and medium-sized coal mines based on gas-sensing detection and single-chip control 被引量:1
8
作者 Bin Guangfu Huang Zhenyu +1 位作者 Zhu Guanghui Li Xuejun 《Engineering Sciences》 EI 2010年第4期47-51,共5页
This paper is aimed at the actual conditions of disaster caused by gas in small and medium-sized coal mines. A new gas concentration monitoring system for coal mines is developed on the basis of gas-sensing detection ... This paper is aimed at the actual conditions of disaster caused by gas in small and medium-sized coal mines. A new gas concentration monitoring system for coal mines is developed on the basis of gas-sensing detection and single-chip control. The monitoring system uses the tin oxide as the main material of N-type semiconductor gas sensors, be- cause it has good sensitive characteristics for the flammable and explosive gas ( such as methane, carbon monoxide). The QM-N5-semiconductor gas sensor is adopted to detect the output values of the resistance under the different gas con- centrations. The system, designedly, takes the AT89C51 digital chip as the core of the circuit processing hardware structure to analyze and judge the input values of the resistance, and then achieve the control and alarm for going beyond the limit of gas concentration. The gas concentration monitoring system has man), advantages including simple in struc- ture, fast response time, stable performance and low cost. Thus, it can be widely used to monitor gas concentration and provide early wamings in small and medium-sized coal mines. 展开更多
关键词 gas concentration monitoring gas-sensing detection single-chip control small and medium-sized coal
下载PDF
Contrast-enhanced micro-computed tomography using Exi Tron nano6000 for assessment of liver injury
9
作者 Xiang-Wei Hua Tian-Fei Lu +6 位作者 Da-Wei Li Wei-Gang Wang Jun Li Zhen-Ze Liu Wei-Wei Lin Jian-Jun Zhang Qiang Xia 《World Journal of Gastroenterology》 SCIE CAS 2015年第26期8043-8051,共9页
AIM: To explore the potential of contrast-enhanced computed tomography(CECT) using Exi Tron nano6000 for assessment of liver lesions in mouse models.METHODS: Three mouse models of liver lesions were used: bile duct li... AIM: To explore the potential of contrast-enhanced computed tomography(CECT) using Exi Tron nano6000 for assessment of liver lesions in mouse models.METHODS: Three mouse models of liver lesions were used: bile duct ligation(BDL),lipopolysaccharide(LPS)/D-galactosamine(D-Gal N),and alcohol.After injection with the contrast agent Exi Tron nano6000,the mice were scanned with micro-CT.Liver lesions were evaluated using CECT images,hematoxylin and eosin staining,and serum aminotransferase levels.Macrophage distribution in the injury models was shown by immunohistochemical staining of CD68.The in vitro studies measured the densities of RAW264.7 under different conditions by CECT.RESULTS: In the in vitro studies,CECT provided specific and strong contrast enhancement of liver in mice.CECT could present heterogeneous images anddensities of injured livers induced by BDL,LPS/D-Gal N,and alcohol.The liver histology and immunochemistry of CD68 demonstrated that both dilated biliary tracts and necrosis in the injured livers could lead to the heterogeneous distribution of macrophages.The in vitro study showed that the RAW264.7 cell masses had higher densities after LPS activation.CONCLUSION: Micro-CT with the contrast agent Exi Tron nano6000 is feasible for detecting various liver lesions by emphasizing the heterogeneous textures and densities of CECT images. 展开更多
关键词 micro-computed TOMOGRAPHY ExiTronNano6000 LIVER INJURY
下载PDF
Microstructure Study of Normal Lunates with Micro-computed Tomography
10
作者 肖滋润 熊革 +2 位作者 shi-gong guo 杜传超 张友乐 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2017年第3期384-389,共6页
In order to study the microstructure characteristics of normal lunate bones, eight fresh cadaver normal lunates were scanned with micro-computed tomography. High-resolution images of the micro-structure of normal luna... In order to study the microstructure characteristics of normal lunate bones, eight fresh cadaver normal lunates were scanned with micro-computed tomography. High-resolution images of the micro-structure of normal lunates were obtained and we analyzed the nutrient foramina. Then nine regions of interest(ROI) were chosen in the central sagittal plane so that we could obtain the parameters of trabecular bones of ROIs. The distal lamellar-like compact structure had statistically significant differences when it was compared with the ROIs in the volar and dorsal ends of the distal cortex. The difference of diameter between the volar and dorsal foramina was significant(P<0.05). However, there was no significant difference regarding the number. The trabecular bones of the volar and dorsal distal ends had lower intensity than those of the distal central subchondral bone plate. The diameters of the nutrient foramina on the volar cortex were larger than those on the dorsal. This research provided more detailed information about microstructure of normal lunate and the nutrient foramina on cortex, and a reference for further study about diseased lunate. 展开更多
关键词 normal lunate trabecular bones micro-computed tomography nutrient foramina
下载PDF
A Single-Chip UHF RFID Reader Transceiver IC
11
作者 Runxi Zhang Chunqi Shi Zongsheng Lai 《Communications and Network》 2013年第3期563-569,共7页
A single-chip UHF RFID reader transceiver IC has been implemented in 0.18 μm SiGe BiCMOS technology. The chip includes all transceiver blocks as RX/TX RF front-end, RX/TX analog baseband, frequency synthesizer and I2... A single-chip UHF RFID reader transceiver IC has been implemented in 0.18 μm SiGe BiCMOS technology. The chip includes all transceiver blocks as RX/TX RF front-end, RX/TX analog baseband, frequency synthesizer and I2C with fully-compliant China 800/900 MHz RFID draft, ISO/IEC 18000-6C protocol and ETSI 302 208-1 local regulation. The normal mode receiver in the presence of -3 dBm self-jammer achieves -75 dBm 1% PER sensitivity. The linear class-A PA integrated in transmitter has 25 dBm OP1 dB output power for CW. The fully-integrated fractional-N fre-quency synthesizer is designed based on MASH 1-1-1 sigma-delta modulator and 1.8 GHz fundamental frequency LC-VCO for lower in-band and out-of-band phase noise. The measured phase noise is up to -106 dBc/Hz@200 kHz and -131 dBc/Hz@1 MHz offset from center frequency and the integrated RMS jitter from 10 kHz to 10 MHz is less than 1.6 pS. The chip dissipates 330 mA from 3.3 V power supply when transmitting 22.4 dBm CW signal and the PAE of linear PA is up to 26%. The chip die area is 16.8 mm2. 展开更多
关键词 Integrated CIRCUIT READER TRANSCEIVER single-chip UHF RFID
下载PDF
Monitoring vascular changes induced by photodynamic therapy using contrast-enhanced micro-computed tomography
12
作者 Otilia C. Nasui Stuart K. Bisland Nancy L. Ford 《Journal of Biomedical Science and Engineering》 2013年第2期124-133,共10页
The aim of this study was to determine whether contrast-enhanced micro-computed tomography can be used for non-invasive imaging of the early-stage changes in the vasculature of tumours that have been treated with phot... The aim of this study was to determine whether contrast-enhanced micro-computed tomography can be used for non-invasive imaging of the early-stage changes in the vasculature of tumours that have been treated with photodynamic therapy (PDT). The subjects used were C3H mice with an RIF-1 tumour implanted subcutaneously and allowed to grow for 3 weeks prior to treatment. The experimental groups were PDT-treated (150 J/cm2 and 50 J/cm2) and control (150 J/cm2 light-only and untreated). The laser light exposure was performed at 15 - 30 minutes after the administration of the photosensitizer (BPD-MA). The contrast-enhanced micro-computed tomography imaging procedure consisted of eight-second scans taking place before treatment and up to 24 hours after treatment. The 150 J/cm2 PDT group showed a significant increase in the ratio of blood volume to tumour volume at 2, 8 and 24 hours after treatment when compared to pre-treatment measurements (p 2 PDT group at 24 hours after treatment. This preliminary study indicates that micro-CT can detect compromised vasculature in tumours treated with high-fluence photodynamic therapy as early as 2 hours post treatment. 展开更多
关键词 micro-computed TOMOGRAPHY CONTRAST AGENT ANIMAL Model Photodynamic THERAPY Cancer
下载PDF
Micro-computed tomography assessment of human femoral trabecular bone for two disease groups(fragility fracture and coxarthrosis):Age and gender related effects on the microstructure
13
作者 Ana Catarina Vale Manuel F.C.Pereira +7 位作者 Antonio Maurício Bruno Vidal Ana Rodrigues Joana Caetano-Lopes Ara Nazarian Joao E.Fonseca Helena Canhao Maria Fatima Vaz 《Journal of Biomedical Science and Engineering》 2013年第2期175-184,共10页
The aim of this study was to identify three-dimensional microstructural changes of trabecular bone with age and gender, using micro-computed tomography. Human trabecular bone from two disease groups, osteoporosis and ... The aim of this study was to identify three-dimensional microstructural changes of trabecular bone with age and gender, using micro-computed tomography. Human trabecular bone from two disease groups, osteoporosis and osteoarthritis was analyzed. A prior analysis of the effects of some procedure variables on the micro-CT results was performed. Preliminary micro-CT scans were performed with three voxel resolutions and two acquisition conditions. On the reconstruction step, the image segmentation was performed with three different threshold values. Samples were collected from patients, with coxarthrosis (osteoarthritis) or fragility fracture (osteoporosis). The specimens of the coxarthrosis group include twenty females and fifteen males, while the fragility fracture group was composed by twenty three females and seven males. The mean age of the population was 69 ± 11 (females) and 67 ± 10 years (males), in the coxarthrosis group, while in the fragility fracture group was 81 ± 6 (females) and 78 ± 6 (males) years. The 30 μm voxel size provided lower percentage difference for the microarchitecture parameters. Acquisition conditions with 160 μA and 60 kV permit the evaluation of all the volume’s sample, with low average values of the coefficients of variation of the microstructural parameters. No statistically significant differences were found between the two diseases groups, neither between genders. However, with aging, there is a decrease of bone volume fraction, trabecular number and fractal dimension, and an increase of structural model index and trabecular separation, for both disease groups and genders. The parameters bone specific surface, trabecular thickness and degree of anisotropy have different behaviors with age, depending on the type of disease. While in coxarthrosis patients, trabecular thickness increases with age, in the fragility fracture group, there is a decrease of trabecular thickness with increasing age. Our findings indicate that disease, age and gender do not provide significant differences in trabecular microstructure. With aging, some parameters exhibit different trends which are possibly related to different mechanisms for different diseases. 展开更多
关键词 Trabecular Bone micro-computed Tomography Coxarthrosis Fragility Fracture Age GENDER
下载PDF
Influence of inter-grain cementation stiffness on the effective elastic properties of porous Bentheim sandstone
14
作者 Bin Chen Jiansheng Xiang John-Paul Latham 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2023年第3期573-583,共11页
Effective elastic properties of porous media are known to be significantly influenced by porosity.In this paper,we investigated the influence of another critical factor,the inter-grain cementation stiffness,on the eff... Effective elastic properties of porous media are known to be significantly influenced by porosity.In this paper,we investigated the influence of another critical factor,the inter-grain cementation stiffness,on the effective elastic properties of a granular porous rock(Bentheim sandstone)using an advanced numerical workflow with realistic rock microstructure and a theoretical model.First,the disparity between the experimentally tested elastic properties of Bentheim sandstone and the effective elastic properties predicted by empirical equations was analysed.Then,a micro-computed tomography(CT)-scan based approach was implemented with digital imaging software AVIZO to construct the 3D(three-dimensional)realistic microstructure of Bentheim sandstone.The microstructural model was imported to a mechanics solver based on the 3D finite element model with inter-grain boundaries modelled by cohesive elements.Loading simulations were run to test the effective elastic properties for different shear and normal intergrain cementation stiffness.Finally,a relation between the macroscale Young’s modulus and inter-grain cementation stiffness was derived with a theoretical model which can also account for porosity explicitly.Both the numerical and theoretical results indicate the influence of the inter-grain cementation stiffness,on the effective elastic properties is significant for porous sandstone.The calibrated normal and shear stiffnesses at the inter-grain boundaries are 1.2×10^(5) and 4×10^(4) GPa/m,respectively. 展开更多
关键词 Porous sandstone Cohesive finite element model Grain-based model Rock microstructure micro-computed tomography(CT)
下载PDF
Three-Point Bending Test and Crack Detection by Acoustic Emission on Different Spring Steel Wires with Different Crystallographic Textures
15
作者 Mathias Lorenz Mohammed Salih +4 位作者 Daniela Schwerdt Nowfal Al-Hamdany Emad Maawad Norbert Schell Eckehard Müller 《材料科学与工程(中英文A版)》 2023年第3期53-67,共15页
In the production of compression springs,high forming velocities and grades of deformation during winding and setting may induce cracks that can lead to failure causing risks of an accident and damage.The AE(acoustic ... In the production of compression springs,high forming velocities and grades of deformation during winding and setting may induce cracks that can lead to failure causing risks of an accident and damage.The AE(acoustic emission)technology,a non-destructive monitoring method,can detect acoustic signals reflected from cracks.To establish this method in the production of technical springs,it was necessary,to find out whether the AE signal is influenced by material properties,phase fractions distribution from tempered martensite,retained austenite,and microstructure including crystallographic texture.In addition,it was investigated to what extent the detected AE signal can be useful to separate between an actual crack and other material responses.Within an in-situ three-point bending test with the AE technology,macro-and micro-crack-typical AE signals were detected for five different spring steel wires(SH,VDSiCr,and FDSiCr according to EN-10270-1 and EN-10270-2).The relative energy related to the initiation,propagation,and growth of cracks caused by mechanical stress was measured using a piezoelectric sensor.If a crack AE signal appeared for the first time,the bending tests were stopped immediately.The results show that the frequency spectrum combined with the intensity of the acoustic signals generated during crack growth depends on the material properties and the crystallographic texture.Furthermore,it could be shown that it is possible to differentiate between micro-crack-typical AE signals and other signals that result from different material responses. 展开更多
关键词 Technical springs AE analysis micro-computer tomography TEXTURE
下载PDF
EVALUATION OF SMALL ANIMAL IMAGING UNDER DIFFERENT SCAN CONDITIONS
16
作者 贾鹏翔 王浩宇 +4 位作者 闫镔 李磊 陈健 张锋 包尚联 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2010年第1期27-33,共7页
To evaluae small animal imaging with individual different high voltage, filter thickness and tube current, an animal X-ray micro-computed tomography (micro-CT) system based on panel detector is developed and a rat i... To evaluae small animal imaging with individual different high voltage, filter thickness and tube current, an animal X-ray micro-computed tomography (micro-CT) system based on panel detector is developed and a rat is scanned by using the system with individual high voltage, tube current, filter thickness, and exposure time. A model is presented based on the Monte Carlo code PENELOPE for generating the X-ray spectra of X-ray tube used in the micro-CT system. A platform developed based on Matlab allows for calculating beam quality parameters, including the average energy of X-ray beam, the change of transmition rate and the input X-ray fluence. The factors affecting the signal difference to noise ratio (SDNR) of micro-CT are investigated and the relationship between SDNR and scan combinations is analyzed. A series of tools and methods are developed for small animal imaging and imaging performance evaluation in the field of small animal imaging. 展开更多
关键词 imaging techniques micro-computed tomography (CT) imaging performance Monte Carlo simulation
下载PDF
Dental and periodontal phenotype in sclerostin knockout mice 被引量:7
17
作者 Ulrike Kuchler Uwe Y Schwarze +4 位作者 Toni Dobsak Patrick Heimel Dieter D Bosshardt Michaela Kneissel Reinhard Gruber 《International Journal of Oral Science》 SCIE CAS CSCD 2014年第2期70-76,共7页
Sclerostin is a Wnt signalling antagonist that controls bone metabolism. Sclerostin is expressed by osteocytes and cementocytes; however, its role in the formation of dental structures remains unclear. Here, we analys... Sclerostin is a Wnt signalling antagonist that controls bone metabolism. Sclerostin is expressed by osteocytes and cementocytes; however, its role in the formation of dental structures remains unclear. Here, we analysed the mandibles of sclerostin knockout mice to determine the influence of sclerostin on dental structures and dimensions using histomorphometry and micro-computed tomography (μCT) imaging, μCT and histomorphometric analyses were performed on the first lower molar and its surrounding structures in mice lacking a functional sclerostin gene and in wild-type controls, pCT on six animals in each group revealed that the dimension of the basal bone as well as the coronal and apical part of alveolar part increased in the sclerostin knockout mice. No significant differences were observed for the tooth and pulp chamber volume. Descriptive histomorphometric analyses of four wild-type and three sclerostin knockout mice demonstrated an increased width of the cementum and a concomitant moderate decrease in the periodontal space width. Taken together, these results suggest that the lack of sclerostin mainly alters the bone and cementum phenotypes rather than producing abnormalities in tooth structures such as dentin. 展开更多
关键词 alveolar bone micro-computed tomography mouse PERIODONTIUM SCLEROSTIN TOOTH
下载PDF
NEW APPROACH TO DETECT CARDIAC-PULMONARY MOTION FOR MICRO-CT SYSTEM
18
作者 田丰 梁春峰 +1 位作者 郭晓莲 胡广书 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2010年第1期1-6,共6页
Non-invasive cardiac-pulmonary gating is proposed to improve the imaging resolution. It produces signals based on the cardiac-pulmonary motion of an animal in real-time. The system with the non-invasive gating consist... Non-invasive cardiac-pulmonary gating is proposed to improve the imaging resolution. It produces signals based on the cardiac-pulmonary motion of an animal in real-time. The system with the non-invasive gating consists of a digital signal processor (DSP), an electrocardiography (ECG) detection circuit and a thermoeouple circuit. An enhanced R wave detection algorithm based on zero crossing counts is used to adjust the low sample frequency associated with the respiratory rate of an animal. The thermocouple recognizes the respiration phase by sensing the temperature changes of the nasal airflow of an animal. The proposed gating can accurately generate the gating signal for freely breathing mice (weight of around 0.03 kg), and its respiratory signal is too weak to be detected. Apart from non-invasiveness, compared with other existing gating techniques, it occupies minimal space at lower cost. Actually, it can be used in micro-computed tomography (CT) and other systems needed to detect the cardiac-pulmonary motion. Several tests validate that the proposed cardiac-pulmonary gating can generate the gating signal as required. By using the gating technique, the image resolution is improved. 展开更多
关键词 micro-computed tomography (CT) respiratory detection R wave detection gating
下载PDF
Optimization of taste-masking on ibuprofen microspheres with selected structure features 被引量:4
19
作者 Wei Qin Yuanzhi He +8 位作者 Zhen Guo Liu Zhang Li Wu Xianzhen Yin Shailendra Shakya Abi Maharjan Yan Tang Weifeng Zhu Jiwen Zhang 《Asian Journal of Pharmaceutical Sciences》 SCIE CAS 2019年第2期174-182,共9页
The microsphere was a primary particulate system for taste-masking with unique structural features defined by production process. In this article, ibuprofen lipid microspheres of octadecanol and glycerin monostearate ... The microsphere was a primary particulate system for taste-masking with unique structural features defined by production process. In this article, ibuprofen lipid microspheres of octadecanol and glycerin monostearate were prepared to mask the undesirable taste of ibuprofen via three kinds of spray congealing processes, namely, air-cooling, water-cooling and citric acid solution-cooling. The stereoscopic and internal structures of ibuprofen microspheres were quantitatively analyzed by synchrotron radiation X-ray micro-computed tomography(SR-μCT) to establish the relationship between the preparation process and microsphere architectures. It was found that the microstructure and morphology of the microspheres were significantly influenced by preparation processes as the primary factors to determine the release profiles and taste-masking effects. The sphericity of ibuprofen microspheres congealed in citric acid solution was higher than that of other two and its morphology was more regular than that being congealed in air or distilled water, and the contact angles between congealing media and melted ibuprofen in octadecanol and glycerin monostearate well demonstrated the structure differences among microspheres of three processes which controlled the release characteristics of the microspheres. The structure parameters like porosity, sphericity, and radius ratio from quantitative analysis were correlated well with drug release behaviors. The results demonstrated that the exterior morphology and internal structure of microspheres had considerable influences on the drug release behaviors as well as taste-masking effects. 展开更多
关键词 IBUPROFEN MICROSPHERE SPRAY congealing Internal structure SYNCHROTRON radiation X-ray micro-computed tomography
下载PDF
单片机,DSP,PLD/EDA的介绍、比较和分析 被引量:2
20
作者 涂亮 王玮 王海林 《山西电子技术》 2004年第6期35-36,共2页
当今,数字时代的核心动力便是单片机,DSP,PLD/EDA,以其各自的特点满足了各种需要,推动着信息技术的快速发展。这里将对这三类电子产品分别加以介绍,并作比较和分析。
关键词 单片机(single-chip Microcomputer) 数字信号处理(DSP) 可编程逻辑器件(PLD)/电子设计自动化(EDA)
下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部