期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Real-Time Method for Detecting Harmonic and Reactive Currents of Single-Phase Circuits 被引量:1
1
作者 张秀峰 丁菊霞 《Journal of Southwest Jiaotong University(English Edition)》 2006年第2期135-141,共7页
According to the characteristics of single-phase circuits and demand of using active filter for real-time detecting harmonic and reactive currents, a detecting method based on Fryze's power definition is proposed. Th... According to the characteristics of single-phase circuits and demand of using active filter for real-time detecting harmonic and reactive currents, a detecting method based on Fryze's power definition is proposed. The results of theoretical analysis and simula- tion show that the proposed method is effective in realtime detecting of instantaneous harmonic and reactive currents in single-phase circuits. When only detecting the total reactive currents, this method does not need a phase-locked loop circuit, and it also can be used in some special applications to provide different compensations on the ground of different requirements of electric network. Compared with the other methods based on the theory of instantaneous reactive power, this method is simple and easy to realize. 展开更多
关键词 Active filter HARMONIC Reactive current Real-time detection single-phase circuit Electric-network
下载PDF
Single-phase earth fault current distribution between optical fiber composite overhead ground wire and ordinary ground wire in transmission system
2
作者 许高雄 《Journal of Chongqing University》 CAS 2011年第2期78-83,共6页
It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of sing... It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of single-phase earth fault current distribution and case verification were accomplished by using the loop method.Influences of some factors,such as single-phase earth fault location and ground resistance of poles,on short-circuit current distribution were discussed.Results show that:1) results of the loop method conform to those of double sided elimination method;2) the fault location hardly influences macro-distribution of short-circuit current.However,current near fault location is evidently influenced;and 3) the short-circuit current distribution is not so sensitive to the ground resistance of poles. 展开更多
关键词 loop method single-phase earth fault short-circuit current distribution optical fiber composite overhead ground wire ordinary ground wire
下载PDF
An Insight into the Second-Harmonic Current Reduction Control Strategies in Two-Stage Converters
3
作者 Lei Ren Lei Zhang 《Energy Engineering》 EI 2022年第3期1179-1196,共18页
Due to the components at twice the fundamental frequency of output voltage in the instantaneous output power of a two-stage single-phase inverter(TSI),the second harmonic current(SHC)is generated in the frontend dc-dc... Due to the components at twice the fundamental frequency of output voltage in the instantaneous output power of a two-stage single-phase inverter(TSI),the second harmonic current(SHC)is generated in the frontend dc-dc converter(FDC).To reduce the SHC,optimizing the control strategy of the FDC is an effective and costless approach.Fromthe view of visual impedance,this paper conducts an intensive study on the SHC reduction strategies.Origin of the SHC is illustrated first.Then,the equivalent circuit models of the FDC under different control strategies are proposed to analyse the SHC propagation characteristic.The derived model can offer a better insight into how the inductor SHC is affected by the control parameters.According to the derived models,a synthesis of different control strategies is presented and the relevant parameters are listed for control design to achieve better suppression effect.The benefits and limitations of these control strategies are also discussed.Based on the proposed equivalent circuit models,several optimization methods are proposed to enhance the effect.A 1500 VA TSI prototype is built and simulated on MATLAB/Simulink,verifying the effectiveness of the proposed optimization methods.This paper is aimed to provide a guideline for the control design and control optimization of the TSIs. 展开更多
关键词 Two-stage single-phase inverter(TSI) second harmonic current(SHC) equivalent circuit models optimization
下载PDF
Improved Control in Single Phase Inverter Grid-Tied PV System Using Modified PQ Theory
4
作者 Nur Fairuz Mohamed Yusof Dahaman Ishak +3 位作者 Muhammad Ammirrul Atiqi Mohd Zainuri Muhammad Najwan Hamidi Zuhair Muhammed Alaas Mohamed Mostafa Ramadan Ahmed 《Intelligent Automation & Soft Computing》 SCIE 2023年第8期2441-2457,共17页
Grid-connected reactive-load compensation and harmonic control are becoming a central topic as photovoltaic(PV)grid-connected systems diversified.This research aims to produce a high-performance inverter with a fast d... Grid-connected reactive-load compensation and harmonic control are becoming a central topic as photovoltaic(PV)grid-connected systems diversified.This research aims to produce a high-performance inverter with a fast dynamic response for accurate reference tracking and a low total har-monic distortion(THD)even under nonlinear load applications by improving its control scheme.The proposed system is expected to operate in both stand-alone mode and grid-connected mode.In stand-alone mode,the proposed controller supplies power to critical loads,alternatively during grid-connected mode provide excess energy to the utility.A modified variable step incremental conductance(VS-InCond)algorithm is designed to extract maximum power from PV.Whereas the proposed inverter controller is achieved by using a modified PQ theory with double-band hysteresis current controller(PQ-DBHCC)to produce a reference current based on a decomposition of a single-phase load current.The nonlinear rectifier loads often create significant distortion in the output voltage of single-phase inverters,due to excessive current harmonics in the grid.Therefore,the proposed method generates a close-loop reference current for the switching scheme,hence,minimizing the inverter voltage distortion caused by the excessive grid current harmonics.The simulation findings suggest the proposed control technique can effectively yield more than 97%of power conversion efficiency while suppressing the grid current THD by less than 2%and maintaining the unity power factor at the grid side.The efficacy of the proposed controller is simulated using MATLAB/Simulink. 展开更多
关键词 Hysteresis current controller incremental conductance nonlinear load PQ theory single-phase inverter
下载PDF
Over Voltage Fault due to Disconnection of Consumer’s Transformer Neutral Wire
5
作者 Erdene Adiyasuren Enkh-Od Erdene +1 位作者 Sergelen Byambaa Shagdarsuren Gantumur 《Journal of Energy and Power Engineering》 2023年第1期11-14,共4页
Practically,the load currents in three phases are asymmetric in the power system.It means that the impedances are different in all three phases.If the consumer’s transformer neutral cut off and/or was disconnected fr... Practically,the load currents in three phases are asymmetric in the power system.It means that the impedances are different in all three phases.If the consumer’s transformer neutral cut off and/or was disconnected from the neutral of power supply source,then there will be some trouble and failure occurred.The current in the neutral wire drops down to zero when the neutral wire is cut off and the phase currents of all three-phase equal to each other since there was no return wire.The currents are equal but the voltages at the phase consumers are different.Especially for residential single-phase consumers,the voltage at the consumers of the phase varies differently for three phase systems when the neutral wire was disconnected at consumer side and even the voltage at the consumers one or two of those three phases becomes over nominal voltage or reaches nearly line voltage.In this case,the electronic appliances in that phase will be fed by high voltage than the rated value and they can be broken down.In the power system of UB(Ulaanbaatar)city,there are some occasional such kind of failures every year.Obviously,many electronic appliances were broken down due to high voltage and the electricity utility companies respond for service charge of damaged parts. 展开更多
关键词 Neutral connection and neutral wire phase and line voltage single-phase residential consumer transformer neutral cut off asymmetric load current protective earth
下载PDF
Reference-input-based Imaginary Axis Current Estimation Method for DQ Control Strategy in Single-phase PWM Converters
6
作者 Lin Peng Lei Ma +1 位作者 Wensheng Song Haoran Liu 《CSEE Journal of Power and Energy Systems》 SCIE EI 2024年第5期2079-2087,共9页
For dq control strategies in single-phase pulse width modulation(PWM)converters,the-axis current must be created by imaginary axis current estimation(IACE)methods.The estimated error of the-axis current during the tra... For dq control strategies in single-phase pulse width modulation(PWM)converters,the-axis current must be created by imaginary axis current estimation(IACE)methods.The estimated error of the-axis current during the transient process causes d-q axis current loops to be incompletely decoupled,thereby affecting the dynamic performance of the current loop.The second-order generalized integrator(SOGI)method suffers from slow dynamic response.The fictive-axis emulation(FAE)method provides fast dynamic response but it is sensitive to circuit parameters.A reference-input(RI)-based IACE method is proposed to overcome the above shortcomings.According to the characteristic that the-axis current loop has no transient process,the-axis current is estimated by the d-q axis reference inputs.This is equivalent to introducing the-axis reference input as a feedforward term into the d-q axis current loop,so the parameter sensitivity problem is solved,and the parameter tuning is not needed.The proposed method can maintain good steadystate performance and significantly improve the dynamic performance of the current loop.Furthermore,it is straightforward and can be easily implemented in digital controllers.Comprehensive hardware-in-the-loop(HIL)experimental comparisons with the SOGI and FAE methods have been conducted to verify the correctness and effectiveness of the proposed RI-based IACE method. 展开更多
关键词 dq control dynamic response imaginary axis current estimation(IACE) single-phase PWM converter
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部