This paper proposes and implements a model-free open-loop iterative learning control(ILC)strategy to realize the speed control of the single-phase flux switching motor(FSM)with an asymmetrical rotor.Base on the propos...This paper proposes and implements a model-free open-loop iterative learning control(ILC)strategy to realize the speed control of the single-phase flux switching motor(FSM)with an asymmetrical rotor.Base on the proposed winding control method,the asymmetrical rotor enables the motor to generate continuous positive torque for positive rotation,and relatively small resistance torque for negative rotation.An initial iteration coefficient and variable iteration coefficient optimized scheme was proposed based on the characteristics of the hardware circuit,thereby forming the model-free strategy.A series of prototype experiments was carried out.Experimental results verify the effectiveness and practicability of the proposed ILC strategy.展开更多
It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of sing...It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of single-phase earth fault current distribution and case verification were accomplished by using the loop method.Influences of some factors,such as single-phase earth fault location and ground resistance of poles,on short-circuit current distribution were discussed.Results show that:1) results of the loop method conform to those of double sided elimination method;2) the fault location hardly influences macro-distribution of short-circuit current.However,current near fault location is evidently influenced;and 3) the short-circuit current distribution is not so sensitive to the ground resistance of poles.展开更多
Five tectonic modes of mantle convection are obtained and analyzed with three-dimensional numerical models in a spherical shell domain.The five tectonic convective modes are non-plate mobile-lid,plate-like mobile-lid,...Five tectonic modes of mantle convection are obtained and analyzed with three-dimensional numerical models in a spherical shell domain.The five tectonic convective modes are non-plate mobile-lid,plate-like mobile-lid,episodic plate-like mobile-lid,episodic stagnant-lid,and stagnant-lid convective modes,respectively.The typical characteristics of these five tectonic modes and their numerical classification criteria based on plateness,mobility,and their standard deviations are presented and discussed.The results show that the yield stress of the lithosphere has profound effects on the tectonic convective modes.With the gradual increase of yield stress,the tectonic mode of mantle convection changes from one to another sequentially through the aforementioned five modes.Additionally,as the Rayleigh number increases,the range of yield stress for the platelike mobile-lid convective mode decreases,and the dimensionless transition stress between different tectonic modes increases.Specifically,the dimensional transition stress between the non-plate mobile-lid convective mode and plate-like mobile-lid convective mode increases with the increase of Rayleigh number,but decreases between other tectonic modes.Furthermore,we find that the transition stress between different tectonic modes is inversely proportional to the internal heating rate,with the transition stress decreasing as the internal heating rate increases.The fitting analysis of the transition stress between tectonic modes shows that Earth's current plate tectonics correspond to a lithospheric yield stress of 150–250 MPa,which aligns with the strength of serpentinized mantle rock determined by experimental petrography.If the Archean mantle was 300℃warmer than it is today,then the Earth was in an episodic stagnant-lid convective mode.The tectonic evolution of the Earth's surface is closely related to the lithospheric strength and the process of thermal evolution.If the lithospheric strength was only 150 MPa,plate tectonics in the early mantle rapid cooling model would have begun before 3.8 Ga,and plate tectonics in the late mantle rapid cooling model would have begun at approximately 1.5 Ga.However,at a lithospheric strength of 200 MPa,plate tectonics in the late mantle rapid cooling model would have begun later than 0.95 Ga,and plate tectonics in the early mantle rapid cooling model would have begun at approximately 2 Ga.The early Earth was in the episodic stagnant-lid convective mode,which means that subduction might still have occurred at that time.The presence of the episodic plate-like mobile-lid convective mode in Earth's later history indicates that there might also have been intermittent surface stagnation during plate tectonics,which may provide an explanation for the quiet period of tectonic activity at approximately 1.0 Ga on Earth.This indicates that tectonic inactivity during a geological period is not an indicator that plate tectonics did not begin.展开更多
The microstructure,mechanical property,and in vitro biocorrosion behavior of as-cast single-phase biodegradable Mg-1.5Zn-0.6Zr alloy were investigated and compared with a commercial as-cast AZ91D alloy.The results sho...The microstructure,mechanical property,and in vitro biocorrosion behavior of as-cast single-phase biodegradable Mg-1.5Zn-0.6Zr alloy were investigated and compared with a commercial as-cast AZ91D alloy.The results show that the Mg-1.5Zn-0.6Zr alloy had a single-phase solid solution structure,with an average grain size of 34.7±13.1μm.The alloy exhibited ultimate tensile strength of 168±2.0 MPa,yield strength of 83±0.6 MPa,and elongation of 9.1±0.6%.Immersion tests and electrochemical measurements reveal that the alloy displayed lower biocorrosion rate and more uniform corrosion mode than AZ91D in Hank's solution.The elimination of intensive galvanic corrosion reactions and the formation of a much more compact and uniform corrosion film mainly account for the better biocorrosion properties of the Mg-1.5Zn-0.6Zr alloy than AZ91D.展开更多
A novel method for the preparation of single-phase ammonium dimolybdate with industrial ammonium molybdate was studied. Various in- fluential factors were evaluated in the paper, including reaction temperature, reacti...A novel method for the preparation of single-phase ammonium dimolybdate with industrial ammonium molybdate was studied. Various in- fluential factors were evaluated in the paper, including reaction temperature, reaction time, initial molybdenum concentration, initial NH_3 /Mo molar ratio, and stirring speed. Under the optimum experimental conditions, the crystallization rate of product is 85.23%. The X-ray diffraction (XRD) analysis and chemical analysis show that the product is single-phase ammonium dimolybdate, and no impurity phases exist. The scanning electronic microscope (SEM) image reveals uniform particle size, good particle dispersion, and no agglomeration between particles. Meanwhile, the final pH value of acidification was investigated. The total molybdenum recovery can reach up to 99.40%, and the main phases of acidification product are the same as those of raw material with the final pH value of 1.5. This determines that the acidification product can be used as a raw material to produce single-phase ammonium dimolybdate.展开更多
Dynamic behavior of coalbed methane (CBM) flow will provide the theoretical basis to optimize production performance for a given well.A mathematical model is developed to simulate flowing pressures and pressure drops ...Dynamic behavior of coalbed methane (CBM) flow will provide the theoretical basis to optimize production performance for a given well.A mathematical model is developed to simulate flowing pressures and pressure drops of CBM column from well head to bottom hole.The measured parameters and independent variables of flow rates,flowing pressures and temperatures are involved in CBM producing process along the annulus.The developed relationships are validated against full-scale measured data in single-phase CBM wellbores.The proposed methodology can analyze the dynamic behavior in CBM reservoir and process of CBM flow with an overall accuracy of 2%.The calculating process of flowing pressures involves friction factor with variable Reynolds number and CBM temperature and compressibility factor with gravitational gradients.The results showed that the effect of flowing pressure on CBM column was more obvious than that on CBM and water column accompanied by an increase of dynamic water level.The ratios of flowing pressure on increment of CBM column to the whole column increased with the declined flow rates of water column.Bottom-hole pressure declined with the decreased flowing pressure of CBM column along the annulus.It will lead to the results of the increased pressure drop of CBM column and CBM flow rate in single-phase CBM wellbores.展开更多
Complex dynamical phenomenon was studied in the single phase H-bridge inverter which was controlled by either a peak current or a valley current. The state functions and the discrete iterative map equations were estab...Complex dynamical phenomenon was studied in the single phase H-bridge inverter which was controlled by either a peak current or a valley current. The state functions and the discrete iterative map equations were established to analyze the dynamical phenomenon in the single phase H-bridge inverter. The dynamical characteristics of the single phase H- bridge inverter, such as time domain waveform diagram, bifurcation diagram, and folding map, were obtained by using the numerical calculation when the circuit parameters varied in specific range. Moreover, the simulation results were obtained by using the OrCAD-PSpice software to validate the numerical calculation. Both the numerical calculation and the circuit simulation show that the symmetrical dynamical phenomenon occurs in the single phase H-bridge inverter controlled by the peak current or the valley current.展开更多
Data centers are recognized as one of the most important aspects of the fourth industrial revolution since conventional data centers are inefficient and have dependency on high energy consumption,in which the cooling ...Data centers are recognized as one of the most important aspects of the fourth industrial revolution since conventional data centers are inefficient and have dependency on high energy consumption,in which the cooling is responsible for 40%of the usage.Therefore,this research proposes the immersion cooling method to solving the high energy consumption of data centers by cooling its component using two types of dielectric fluids.Four stages of experimentalmethods are used,such as fluid types,cooling effectiveness,optimization,and durability.Furthermore,benchmark software is used to measure the CPU maximum work with the temperature data performed for 24 h.The results of this study show that the immersion cooling reduces 13℃ lower temperature than the conventional cooling method which means it saves more energy consumption in the data center.The most optimum variable used to decrease the temperature is 1.5 lpm of flow rate and 800 rpm of fan rotation.Furthermore,the cooling performance of the dielectric fluids shows that the mineral oil(MO)is better than the virgin coconut oil(VCO).In durability experiment,there are no components damage after five months immersed in the fluid.展开更多
Outdoor power transformers are one of the most pervasive noise sources in power transmission and distribution systems.Accurate prediction of outdoor noise propagation plays a dominant role for the evaluation and contr...Outdoor power transformers are one of the most pervasive noise sources in power transmission and distribution systems.Accurate prediction of outdoor noise propagation plays a dominant role for the evaluation and control of noise relevant to the transformer stations.In this paper surface vibration tests are carried out on a scale model of a single-phase transformer tank wall at different excitation frequencies.The phase and amplitude of test data are found to be randomly distributed when the excitation frequency exceeds the seventh mode frequency,which allows the single-phase power transformer to be simplified as incoherent point sources.An outdoor-coherent model is subsequently developed and incorporated with the image source method to investigate noise propagation from single-phase power transformers,due to the occurrence of multiple reflections and diffractions in the propagation path of each point source.The proposed model is used to calculate the sound field of the power transformer group by exploiting the additional phase information.In comparison with the ISO9613 model and the boundary element method,it is found that the proposed coherent image source method leads to more accurate prediction results,and hence better performance for the prediction of the outdoor noise induced by single-phase power transformers.展开更多
The new 6-switch single-phase 5-level current-source inverter proposed in this paper was developed by properly simplifying the traditional 8-switch single-phase 5-level current-source inverter, and its operational pri...The new 6-switch single-phase 5-level current-source inverter proposed in this paper was developed by properly simplifying the traditional 8-switch single-phase 5-level current-source inverter, and its operational principle was analyzed. Just like the problem of voltage-unbalance between different levels existing in voltage-source multilevel inverters, a similar problem of current-unbalance between different levels whether for the 8-switch single-phase 5-level current-source inverter, or for the new 6-switch 5-level current-source inverter also exists. A simple current-balance control method via DC current feedback is presented here to implement the current-balance control between different levels. And to reduce the output current harmonics, PWM control technique was used. Simulation and experimental results showed that this new 6-switch topology operates correctly and that the balance-inductor can almost equally distribute the total DC current.展开更多
According to the characteristics of single-phase circuits and demand of using active filter for real-time detecting harmonic and reactive currents, a detecting method based on Fryze's power definition is proposed. Th...According to the characteristics of single-phase circuits and demand of using active filter for real-time detecting harmonic and reactive currents, a detecting method based on Fryze's power definition is proposed. The results of theoretical analysis and simula- tion show that the proposed method is effective in realtime detecting of instantaneous harmonic and reactive currents in single-phase circuits. When only detecting the total reactive currents, this method does not need a phase-locked loop circuit, and it also can be used in some special applications to provide different compensations on the ground of different requirements of electric network. Compared with the other methods based on the theory of instantaneous reactive power, this method is simple and easy to realize.展开更多
A single-phase lattice Boltzmann model with modified surface tension is developed in this paper to solve the problem of high-density-ratio free surface flow.The computational efficiency and accuracy are both enhanced....A single-phase lattice Boltzmann model with modified surface tension is developed in this paper to solve the problem of high-density-ratio free surface flow.The computational efficiency and accuracy are both enhanced.The restriction to the relaxation factor (which needs to be smaller than 1) is circumvented by the new surface tension algebra,due to its rational physical nature compared with the treatment of Xing,Buther and Yang in their paper (Comp.Mater.Sci.,2007,39(2):282-290).The proposed stable surface tension scheme is applied to simulate the free deformation of a square droplet with surface tension effect and the process of a droplet impinging on a liquid film.The numerical solution for free deformation of a droplet agrees well with thermodynamic principles,and also achieves high accuracy in comparison with Xing,et al.'s model.Three typical impinging modes are successfully obtained with the new scheme,and another particular mode found by Wang and Chen is also successfully simulated.The evolutions of liquid crown agree well with the power law related to time.展开更多
This paper presents and tests three earthing systems (TT, TN and IT) for Micro-Grid (MG) protection against various fault types when the MG transferred to the islanding mode. The main contribution of this work is incl...This paper presents and tests three earthing systems (TT, TN and IT) for Micro-Grid (MG) protection against various fault types when the MG transferred to the islanding mode. The main contribution of this work is including the models of all micro sources which interfaced to the MG by power electronic inverters. Inverters in turns are provided with current limiters and this also included with the inverter models to exactly simulate the real situation in the MG during fault times. Results proved that the most suitable earthing system for MG protection during the islanding mode is the TN earthing system. That system leads to a suitable amount of fault current sufficient to activate over current pro-tection relays. With using TN earthing system, touch voltages at the faulted bus and all other consumer’s buses are less than the safety limited values during islanding mode. For the two others earthing systems (TT and IT), fault currents are small and nearly equal to the over load currents which make over current protection relay can not differentiate between fault currents and overload currents. All models of micro sources, earthing systems, inverters and control schemes are built using Matlab?/Simulink? environment.展开更多
This paper presents, tests and compares three earthing systems (TT, TN and IT) for Micro-Grid (MG) protection against various fault types during the connected mode. The main contribution of this work is including the ...This paper presents, tests and compares three earthing systems (TT, TN and IT) for Micro-Grid (MG) protection against various fault types during the connected mode. The main contribution of this work is including the models of all the micro sources which interfaced to the MG by power electronic inverters. Inverters in turns are provided with current limiters and this also included in the inverter models to exactly simulate the real situation in the MG during fault times. Results proved that the most suitable earthing system for MG protection during the connecting mode is the TN earthing system. That system leads to a suitable amount of fault current sufficient to activate over current protection relays. With using TN system, Touch voltages at the faulted bus and all other consumer’s buses are less than the safety limited value if current limiter is included with the transformer of the main grid which connects MG. For the two others earthing systems (TT and IT), fault current is small and nearly equal to the over load current which make over current protection relay can not differentiate between fault current and overload current. All models of micro sources, earthing systems, inverters, main grid and control schemes are built using Matlab?/Simulink? environment.展开更多
To avoid stray current and maintain the benefit of no phase-split in the DC traction power supply system, an AC traction power supply system was proposed for the urban public transport such as metro and light rail tra...To avoid stray current and maintain the benefit of no phase-split in the DC traction power supply system, an AC traction power supply system was proposed for the urban public transport such as metro and light rail transit. The proposed system consists of a main substation (MSS) and cable traction network (CTN). The MSS includes a single-phase main traction transformer and a negative-se- quence compensation device, while the CTN includes double-core cables, traction transformers, overhead catenary system, rails, etc. Several key techniques for the proposed system were put forward and discussed, which can be summarized as (1) the power supply principle, equivalent circuit and transmission ability of the CTN, the cable-catenary matching technique, and the selection of catenary voltage level; (2) the segmentation technology and status identification method for traction power supply network, distributed and centralized protection schemes, etc.; (3) a power supply scheme for single-line MSS and a power supply scheme of MSS shared by two or more lines. The proposed industrial frequency single-phase AC traction power supply system shows an excellent technical performance, good economy, and high reliability, hence provides a new alternative for metro and urban rail transit power supply systems.展开更多
The phosphors of KY_(1-x)(MoO_(4))_(2-y)(WO_(4))y:xLn^(3+)(Ln^(3+)=Tm^(3+),Dy^(3+),Eu^(3+))were synthesized by using a sol-gel method.Then,the crystal structure,luminescence properties,energy transfer,and white emissi...The phosphors of KY_(1-x)(MoO_(4))_(2-y)(WO_(4))y:xLn^(3+)(Ln^(3+)=Tm^(3+),Dy^(3+),Eu^(3+))were synthesized by using a sol-gel method.Then,the crystal structure,luminescence properties,energy transfer,and white emission of the prepared materials were researched.The molar ratio of the anion group on the photoluminescence(PL)emission and excitation intensity were investigated,revealing that the optimum intensity could be obtained by using=3:1.The optimal Dy^(3+) doping concentration of KY(MoO_(4))1.5(WO4)0.5was obtained.In addition,the color-tunable emissions of Dy^(3+)/Eu^(3+)-codoped KY(MoO_(4))1.5(WO4)0.5phosphors were observed because of the effective energy transfer(ET)from Dy^(3+)to Eu^(3+)ions.Finally,by doping appropriate concentrations of Tm^(3+),Dy^(3+),and Eu^(3+)and different concentrations of(WO_(4))^(2-),white light emitting phosphors KY_(0.92)(WO_(4))2:0.01Tm^(3+),0.06Dy^(3+),0.01Eu^(3+)with excellent color-rending properties were obtained.The chromaticity coordinate was calculated as(x=0.3238,y=0.3173),closing to the artificial daylight(D65,x=0.313,y=0.329)illuminant,and which indicates the potential application of near ultraviolet White light-emitting diodes(WLEDs).展开更多
文摘This paper proposes and implements a model-free open-loop iterative learning control(ILC)strategy to realize the speed control of the single-phase flux switching motor(FSM)with an asymmetrical rotor.Base on the proposed winding control method,the asymmetrical rotor enables the motor to generate continuous positive torque for positive rotation,and relatively small resistance torque for negative rotation.An initial iteration coefficient and variable iteration coefficient optimized scheme was proposed based on the characteristics of the hardware circuit,thereby forming the model-free strategy.A series of prototype experiments was carried out.Experimental results verify the effectiveness and practicability of the proposed ILC strategy.
文摘It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of single-phase earth fault current distribution and case verification were accomplished by using the loop method.Influences of some factors,such as single-phase earth fault location and ground resistance of poles,on short-circuit current distribution were discussed.Results show that:1) results of the loop method conform to those of double sided elimination method;2) the fault location hardly influences macro-distribution of short-circuit current.However,current near fault location is evidently influenced;and 3) the short-circuit current distribution is not so sensitive to the ground resistance of poles.
基金supported by the National Natural Science Foundation of China(Grant Nos.42074105 and 92155204)the Strategic Priority Research Program of the Chinese Academy of Sciences(Grant No.XDB 41000000)。
文摘Five tectonic modes of mantle convection are obtained and analyzed with three-dimensional numerical models in a spherical shell domain.The five tectonic convective modes are non-plate mobile-lid,plate-like mobile-lid,episodic plate-like mobile-lid,episodic stagnant-lid,and stagnant-lid convective modes,respectively.The typical characteristics of these five tectonic modes and their numerical classification criteria based on plateness,mobility,and their standard deviations are presented and discussed.The results show that the yield stress of the lithosphere has profound effects on the tectonic convective modes.With the gradual increase of yield stress,the tectonic mode of mantle convection changes from one to another sequentially through the aforementioned five modes.Additionally,as the Rayleigh number increases,the range of yield stress for the platelike mobile-lid convective mode decreases,and the dimensionless transition stress between different tectonic modes increases.Specifically,the dimensional transition stress between the non-plate mobile-lid convective mode and plate-like mobile-lid convective mode increases with the increase of Rayleigh number,but decreases between other tectonic modes.Furthermore,we find that the transition stress between different tectonic modes is inversely proportional to the internal heating rate,with the transition stress decreasing as the internal heating rate increases.The fitting analysis of the transition stress between tectonic modes shows that Earth's current plate tectonics correspond to a lithospheric yield stress of 150–250 MPa,which aligns with the strength of serpentinized mantle rock determined by experimental petrography.If the Archean mantle was 300℃warmer than it is today,then the Earth was in an episodic stagnant-lid convective mode.The tectonic evolution of the Earth's surface is closely related to the lithospheric strength and the process of thermal evolution.If the lithospheric strength was only 150 MPa,plate tectonics in the early mantle rapid cooling model would have begun before 3.8 Ga,and plate tectonics in the late mantle rapid cooling model would have begun at approximately 1.5 Ga.However,at a lithospheric strength of 200 MPa,plate tectonics in the late mantle rapid cooling model would have begun later than 0.95 Ga,and plate tectonics in the early mantle rapid cooling model would have begun at approximately 2 Ga.The early Earth was in the episodic stagnant-lid convective mode,which means that subduction might still have occurred at that time.The presence of the episodic plate-like mobile-lid convective mode in Earth's later history indicates that there might also have been intermittent surface stagnation during plate tectonics,which may provide an explanation for the quiet period of tectonic activity at approximately 1.0 Ga on Earth.This indicates that tectonic inactivity during a geological period is not an indicator that plate tectonics did not begin.
基金This project was supported by the National Natural Science Foundation of China(No.51174025)Specialized Research Fund for the Doctoral Program of Higher Education of China(No.20110006130004).
文摘The microstructure,mechanical property,and in vitro biocorrosion behavior of as-cast single-phase biodegradable Mg-1.5Zn-0.6Zr alloy were investigated and compared with a commercial as-cast AZ91D alloy.The results show that the Mg-1.5Zn-0.6Zr alloy had a single-phase solid solution structure,with an average grain size of 34.7±13.1μm.The alloy exhibited ultimate tensile strength of 168±2.0 MPa,yield strength of 83±0.6 MPa,and elongation of 9.1±0.6%.Immersion tests and electrochemical measurements reveal that the alloy displayed lower biocorrosion rate and more uniform corrosion mode than AZ91D in Hank's solution.The elimination of intensive galvanic corrosion reactions and the formation of a much more compact and uniform corrosion film mainly account for the better biocorrosion properties of the Mg-1.5Zn-0.6Zr alloy than AZ91D.
基金supported by the National Natural Science Foundation of China(No.51072233)
文摘A novel method for the preparation of single-phase ammonium dimolybdate with industrial ammonium molybdate was studied. Various in- fluential factors were evaluated in the paper, including reaction temperature, reaction time, initial molybdenum concentration, initial NH_3 /Mo molar ratio, and stirring speed. Under the optimum experimental conditions, the crystallization rate of product is 85.23%. The X-ray diffraction (XRD) analysis and chemical analysis show that the product is single-phase ammonium dimolybdate, and no impurity phases exist. The scanning electronic microscope (SEM) image reveals uniform particle size, good particle dispersion, and no agglomeration between particles. Meanwhile, the final pH value of acidification was investigated. The total molybdenum recovery can reach up to 99.40%, and the main phases of acidification product are the same as those of raw material with the final pH value of 1.5. This determines that the acidification product can be used as a raw material to produce single-phase ammonium dimolybdate.
基金This work was financially supported by National Science and Technology Major Project of the Ministry of Science and Technology of China(2016ZX05065-001),Key Research Project of Shandong Province(2019GHY112029 and 2019GSF109090)and Higher Education Research and Development Project of Shandong Province(J17KA033).
文摘Dynamic behavior of coalbed methane (CBM) flow will provide the theoretical basis to optimize production performance for a given well.A mathematical model is developed to simulate flowing pressures and pressure drops of CBM column from well head to bottom hole.The measured parameters and independent variables of flow rates,flowing pressures and temperatures are involved in CBM producing process along the annulus.The developed relationships are validated against full-scale measured data in single-phase CBM wellbores.The proposed methodology can analyze the dynamic behavior in CBM reservoir and process of CBM flow with an overall accuracy of 2%.The calculating process of flowing pressures involves friction factor with variable Reynolds number and CBM temperature and compressibility factor with gravitational gradients.The results showed that the effect of flowing pressure on CBM column was more obvious than that on CBM and water column accompanied by an increase of dynamic water level.The ratios of flowing pressure on increment of CBM column to the whole column increased with the declined flow rates of water column.Bottom-hole pressure declined with the decreased flowing pressure of CBM column along the annulus.It will lead to the results of the increased pressure drop of CBM column and CBM flow rate in single-phase CBM wellbores.
基金Project supported by the National Natural Science Foundation of China(Grant No.51107016)the National Basic Research Program of China(Grant No.2013CB035605)the Postdoctoral Science Research Developmental Foundation of Heilongjiang Province,China(Grant No.LHB-Q12086)
文摘Complex dynamical phenomenon was studied in the single phase H-bridge inverter which was controlled by either a peak current or a valley current. The state functions and the discrete iterative map equations were established to analyze the dynamical phenomenon in the single phase H-bridge inverter. The dynamical characteristics of the single phase H- bridge inverter, such as time domain waveform diagram, bifurcation diagram, and folding map, were obtained by using the numerical calculation when the circuit parameters varied in specific range. Moreover, the simulation results were obtained by using the OrCAD-PSpice software to validate the numerical calculation. Both the numerical calculation and the circuit simulation show that the symmetrical dynamical phenomenon occurs in the single phase H-bridge inverter controlled by the peak current or the valley current.
基金This work is financially supported by the Ministry of Research and Technology of Indonesia(BRIN)in the project called“Penggunaan Immersion Cooling untukMeningkatkan Efisiensi Energi Data Center”.
文摘Data centers are recognized as one of the most important aspects of the fourth industrial revolution since conventional data centers are inefficient and have dependency on high energy consumption,in which the cooling is responsible for 40%of the usage.Therefore,this research proposes the immersion cooling method to solving the high energy consumption of data centers by cooling its component using two types of dielectric fluids.Four stages of experimentalmethods are used,such as fluid types,cooling effectiveness,optimization,and durability.Furthermore,benchmark software is used to measure the CPU maximum work with the temperature data performed for 24 h.The results of this study show that the immersion cooling reduces 13℃ lower temperature than the conventional cooling method which means it saves more energy consumption in the data center.The most optimum variable used to decrease the temperature is 1.5 lpm of flow rate and 800 rpm of fan rotation.Furthermore,the cooling performance of the dielectric fluids shows that the mineral oil(MO)is better than the virgin coconut oil(VCO).In durability experiment,there are no components damage after five months immersed in the fluid.
基金This work is funded by the Anhui Natural Science Foundation Project of China(under Grant KJ2016A201)the National Natural Science Foundation of China(under Grant 11774378).
文摘Outdoor power transformers are one of the most pervasive noise sources in power transmission and distribution systems.Accurate prediction of outdoor noise propagation plays a dominant role for the evaluation and control of noise relevant to the transformer stations.In this paper surface vibration tests are carried out on a scale model of a single-phase transformer tank wall at different excitation frequencies.The phase and amplitude of test data are found to be randomly distributed when the excitation frequency exceeds the seventh mode frequency,which allows the single-phase power transformer to be simplified as incoherent point sources.An outdoor-coherent model is subsequently developed and incorporated with the image source method to investigate noise propagation from single-phase power transformers,due to the occurrence of multiple reflections and diffractions in the propagation path of each point source.The proposed model is used to calculate the sound field of the power transformer group by exploiting the additional phase information.In comparison with the ISO9613 model and the boundary element method,it is found that the proposed coherent image source method leads to more accurate prediction results,and hence better performance for the prediction of the outdoor noise induced by single-phase power transformers.
基金Project (No. 50477033) supported by the National Natural ScienceFoundation of China
文摘The new 6-switch single-phase 5-level current-source inverter proposed in this paper was developed by properly simplifying the traditional 8-switch single-phase 5-level current-source inverter, and its operational principle was analyzed. Just like the problem of voltage-unbalance between different levels existing in voltage-source multilevel inverters, a similar problem of current-unbalance between different levels whether for the 8-switch single-phase 5-level current-source inverter, or for the new 6-switch 5-level current-source inverter also exists. A simple current-balance control method via DC current feedback is presented here to implement the current-balance control between different levels. And to reduce the output current harmonics, PWM control technique was used. Simulation and experimental results showed that this new 6-switch topology operates correctly and that the balance-inductor can almost equally distribute the total DC current.
文摘According to the characteristics of single-phase circuits and demand of using active filter for real-time detecting harmonic and reactive currents, a detecting method based on Fryze's power definition is proposed. The results of theoretical analysis and simula- tion show that the proposed method is effective in realtime detecting of instantaneous harmonic and reactive currents in single-phase circuits. When only detecting the total reactive currents, this method does not need a phase-locked loop circuit, and it also can be used in some special applications to provide different compensations on the ground of different requirements of electric network. Compared with the other methods based on the theory of instantaneous reactive power, this method is simple and easy to realize.
基金supported by the National Natural Science Foundation of China (Grant Nos.10625210,50609020 and 10902070)the Leading Academic Discipline Project of Shanghai Municipal Education Commission (Grant No.J50501)
文摘A single-phase lattice Boltzmann model with modified surface tension is developed in this paper to solve the problem of high-density-ratio free surface flow.The computational efficiency and accuracy are both enhanced.The restriction to the relaxation factor (which needs to be smaller than 1) is circumvented by the new surface tension algebra,due to its rational physical nature compared with the treatment of Xing,Buther and Yang in their paper (Comp.Mater.Sci.,2007,39(2):282-290).The proposed stable surface tension scheme is applied to simulate the free deformation of a square droplet with surface tension effect and the process of a droplet impinging on a liquid film.The numerical solution for free deformation of a droplet agrees well with thermodynamic principles,and also achieves high accuracy in comparison with Xing,et al.'s model.Three typical impinging modes are successfully obtained with the new scheme,and another particular mode found by Wang and Chen is also successfully simulated.The evolutions of liquid crown agree well with the power law related to time.
文摘This paper presents and tests three earthing systems (TT, TN and IT) for Micro-Grid (MG) protection against various fault types when the MG transferred to the islanding mode. The main contribution of this work is including the models of all micro sources which interfaced to the MG by power electronic inverters. Inverters in turns are provided with current limiters and this also included with the inverter models to exactly simulate the real situation in the MG during fault times. Results proved that the most suitable earthing system for MG protection during the islanding mode is the TN earthing system. That system leads to a suitable amount of fault current sufficient to activate over current pro-tection relays. With using TN earthing system, touch voltages at the faulted bus and all other consumer’s buses are less than the safety limited values during islanding mode. For the two others earthing systems (TT and IT), fault currents are small and nearly equal to the over load currents which make over current protection relay can not differentiate between fault currents and overload currents. All models of micro sources, earthing systems, inverters and control schemes are built using Matlab?/Simulink? environment.
文摘This paper presents, tests and compares three earthing systems (TT, TN and IT) for Micro-Grid (MG) protection against various fault types during the connected mode. The main contribution of this work is including the models of all the micro sources which interfaced to the MG by power electronic inverters. Inverters in turns are provided with current limiters and this also included in the inverter models to exactly simulate the real situation in the MG during fault times. Results proved that the most suitable earthing system for MG protection during the connecting mode is the TN earthing system. That system leads to a suitable amount of fault current sufficient to activate over current protection relays. With using TN system, Touch voltages at the faulted bus and all other consumer’s buses are less than the safety limited value if current limiter is included with the transformer of the main grid which connects MG. For the two others earthing systems (TT and IT), fault current is small and nearly equal to the over load current which make over current protection relay can not differentiate between fault current and overload current. All models of micro sources, earthing systems, inverters, main grid and control schemes are built using Matlab?/Simulink? environment.
文摘To avoid stray current and maintain the benefit of no phase-split in the DC traction power supply system, an AC traction power supply system was proposed for the urban public transport such as metro and light rail transit. The proposed system consists of a main substation (MSS) and cable traction network (CTN). The MSS includes a single-phase main traction transformer and a negative-se- quence compensation device, while the CTN includes double-core cables, traction transformers, overhead catenary system, rails, etc. Several key techniques for the proposed system were put forward and discussed, which can be summarized as (1) the power supply principle, equivalent circuit and transmission ability of the CTN, the cable-catenary matching technique, and the selection of catenary voltage level; (2) the segmentation technology and status identification method for traction power supply network, distributed and centralized protection schemes, etc.; (3) a power supply scheme for single-line MSS and a power supply scheme of MSS shared by two or more lines. The proposed industrial frequency single-phase AC traction power supply system shows an excellent technical performance, good economy, and high reliability, hence provides a new alternative for metro and urban rail transit power supply systems.
文摘The phosphors of KY_(1-x)(MoO_(4))_(2-y)(WO_(4))y:xLn^(3+)(Ln^(3+)=Tm^(3+),Dy^(3+),Eu^(3+))were synthesized by using a sol-gel method.Then,the crystal structure,luminescence properties,energy transfer,and white emission of the prepared materials were researched.The molar ratio of the anion group on the photoluminescence(PL)emission and excitation intensity were investigated,revealing that the optimum intensity could be obtained by using=3:1.The optimal Dy^(3+) doping concentration of KY(MoO_(4))1.5(WO4)0.5was obtained.In addition,the color-tunable emissions of Dy^(3+)/Eu^(3+)-codoped KY(MoO_(4))1.5(WO4)0.5phosphors were observed because of the effective energy transfer(ET)from Dy^(3+)to Eu^(3+)ions.Finally,by doping appropriate concentrations of Tm^(3+),Dy^(3+),and Eu^(3+)and different concentrations of(WO_(4))^(2-),white light emitting phosphors KY_(0.92)(WO_(4))2:0.01Tm^(3+),0.06Dy^(3+),0.01Eu^(3+)with excellent color-rending properties were obtained.The chromaticity coordinate was calculated as(x=0.3238,y=0.3173),closing to the artificial daylight(D65,x=0.313,y=0.329)illuminant,and which indicates the potential application of near ultraviolet White light-emitting diodes(WLEDs).