This paper discusses a novel boost single-phase active AC-DC converters, named low-end semi-controlled bridge AC-DC converter. By analysis, its topology and principle can be derived from the conventional single-phase ...This paper discusses a novel boost single-phase active AC-DC converters, named low-end semi-controlled bridge AC-DC converter. By analysis, its topology and principle can be derived from the conventional single-phase power factor corrector ( PFC). But it has also some differences, such as power device positions, inductor type, input voltage waveform detection and induction current detection, so its design is also different. The converter is implemented by employing two current detection approaches, i.e., current transformer detection and shunt resistor detection. Consequently, it can provide a steady DC output voltage with a low voltage ripple, approximately unitary input power factor and 2.5 kW output power. The experimental results show validity of the theoretical analysis.展开更多
Based on the output-voltage error function, a novel time discrete modulation technique is proposed for matrix converters (MCs) and time-discrete difference equations of a MC circuit are derived. Switch states of MC ...Based on the output-voltage error function, a novel time discrete modulation technique is proposed for matrix converters (MCs) and time-discrete difference equations of a MC circuit are derived. Switch states of MC are obtained when the output voltage error function is minimized, thus the optimum combination of switch states is derived for the closed-loop control of MC. Meanwhile, advantages of the least calculation workload, the simple process, and the convenient for implementation are brought while switch states are described as space vectors in the α-β coordination system. Simulation and experimental results demonstrate the validity of the time-discrete modulation technique and the feasibility of the control approach.展开更多
To reduce the torque ripple in motors resulting from the use of conventional direct torque control(DTC),a model predictive control(MPC)-based DTC strategy for a direct matrix converter-fed induction motor is proposed ...To reduce the torque ripple in motors resulting from the use of conventional direct torque control(DTC),a model predictive control(MPC)-based DTC strategy for a direct matrix converter-fed induction motor is proposed in this paper.Two new look-up tables are proposed,these are derived on the basis of the control of the electromagnetic torque and stator flux using all the feasible voltage vectors and their associated switching states.Finite control set model predictive control(FCS-MPC)has then been adopted to select the optimal switching state that minimizes the cost function related to the electromagnetic torque.Finally,the experimental results are shown to verify the reduced torque ripple performance of the proposed MPC-based DTC method.展开更多
Employing matrix converter (MC) as driving mode, the strategy of model predictive torque control (MPTC) is proposed for three phase permanent magnet synchronous motor (PMSM) system. MC is applied instead of conv...Employing matrix converter (MC) as driving mode, the strategy of model predictive torque control (MPTC) is proposed for three phase permanent magnet synchronous motor (PMSM) system. MC is applied instead of conventional AC DC AC converter to increase the power factor (PF) of the system input side. MPTC is used to select optimal voltage space vector to enable the system to have satisfactory torque and flux control effect. The resultant MPTC strategy not only makes the MC fed PMSM system operate reliably and have perfect control performance, but also makes the PF of the system input side be 1. Compared with direct torque control (DTC), the proposed MPTC strategy guarantees that MC fed PMSM has better command following characteristics in the presence of variation of load torque and tracking reference speed. Simulation results verify the feasibility and effectiveness of the proposed strategy.展开更多
For dq control strategies in single-phase pulse width modulation(PWM)converters,the-axis current must be created by imaginary axis current estimation(IACE)methods.The estimated error of the-axis current during the tra...For dq control strategies in single-phase pulse width modulation(PWM)converters,the-axis current must be created by imaginary axis current estimation(IACE)methods.The estimated error of the-axis current during the transient process causes d-q axis current loops to be incompletely decoupled,thereby affecting the dynamic performance of the current loop.The second-order generalized integrator(SOGI)method suffers from slow dynamic response.The fictive-axis emulation(FAE)method provides fast dynamic response but it is sensitive to circuit parameters.A reference-input(RI)-based IACE method is proposed to overcome the above shortcomings.According to the characteristic that the-axis current loop has no transient process,the-axis current is estimated by the d-q axis reference inputs.This is equivalent to introducing the-axis reference input as a feedforward term into the d-q axis current loop,so the parameter sensitivity problem is solved,and the parameter tuning is not needed.The proposed method can maintain good steadystate performance and significantly improve the dynamic performance of the current loop.Furthermore,it is straightforward and can be easily implemented in digital controllers.Comprehensive hardware-in-the-loop(HIL)experimental comparisons with the SOGI and FAE methods have been conducted to verify the correctness and effectiveness of the proposed RI-based IACE method.展开更多
A comprehensive proton-exchange membrane fuel cell stack model was developed and integrated with a two-stage DC/DC boost converter.It was directly coupled to a single-phase(two levels-four pulses)inverter without a tr...A comprehensive proton-exchange membrane fuel cell stack model was developed and integrated with a two-stage DC/DC boost converter.It was directly coupled to a single-phase(two levels-four pulses)inverter without a transformer.The pulse-width modu-lation signal was used to independently regulate every converter phase.The converter was modelled using a MATLAB®/Simulink®environment and an appropriate voltage control method.The analysis features of the suggested circuit were created and,through established experiments,the simulation results were verified.A single-phase(two levels-four pulses)inverter control circuit was tested and it produced a pure sinusoidal waveform with voltage control.It matches the voltage of the network in terms of amplitude and frequency.A sinusoidal pulse-width modulation approach was performed using a single-phase(two levels-four pulses)pulse-width modulation inverter.The results demonstrated an enhancement in the standard of the output wave and tuned the dead time with a reduction of 63μs compared with 180μs in conventional techniques.展开更多
Matrix converter fed motor drive is superior to pulse width modulation inverter drives since it not only provides bi-directional power flow,sinusoidal input/output currents,unity input power factor,but also allows a c...Matrix converter fed motor drive is superior to pulse width modulation inverter drives since it not only provides bi-directional power flow,sinusoidal input/output currents,unity input power factor,but also allows a compact design due to the lack of DC-link capacitors for energy storage.In this paper,model and control of matrix converter fed induction motor drive system are analyzed.A combined control strategy is simplified and improved,which realizes space vector pulse width modulation of matrix converter and rotor flux oriented vector control technique for induction motor drive simultaneously.This control strategy combines the advantages of matrix converter with the good drive performance of vector control technique.Experimental results demonstrate the feasibility and effectiveness of the proposed control strategy.展开更多
The behavior of matrix converter(MC) drive systems under the condition of MC short-circuit faults is comprehensively investigated. Two isolation strategies using semiconductors and high speed fuses(HSFs) for MC short-...The behavior of matrix converter(MC) drive systems under the condition of MC short-circuit faults is comprehensively investigated. Two isolation strategies using semiconductors and high speed fuses(HSFs) for MC short-circuit faults are examined and their performances are compared. The behavior of MC drive systems during the fuse action time under different operating conditions is explored. The feasibility of fault-tolerant operation during the fuse action time is also studied. The basic selection laws for the HSFs and the requirements for the passive components of the MC drive system from the point view of short-circuit faults are also discussed. Simulation results are used to demonstrate the feasibility of the proposed isolation strategies.展开更多
This paper presents a thorough design and comparative study of two popular control techniques, i.e., classical Proportional Integral (PI) and RST, for Matrix Converters (MCs) in terms of tracking the reference and rob...This paper presents a thorough design and comparative study of two popular control techniques, i.e., classical Proportional Integral (PI) and RST, for Matrix Converters (MCs) in terms of tracking the reference and robustness. The output signal of MCs is directly affected by unbalanced grid voltage. Some research works have attempted to overcome this problem with PI control. However, this technique is known to offer lower performance when it is used in complex and nonlinear systems. On the other hand, RST control offers better performance, even in case of highly nonlinear systems. Therefore, the RST can achieve better performance to overcome the limitation of PI control of nonlinear systems. In this paper, a RST control method is proposed as output current controller to improve the performance of the MC powered by unbalanced grid voltage. The overall operating principle, Venturini modulation strategy of MC, PI control and characteristics of RST are presented.展开更多
Based on the topological analysis of three-phase matrix AC to AC conversion circuit, an AC to AC nine-switch matrix isequivalent to rectification part and conversion part. The Matrix converter can be viewed as AC-DC-A...Based on the topological analysis of three-phase matrix AC to AC conversion circuit, an AC to AC nine-switch matrix isequivalent to rectification part and conversion part. The Matrix converter can be viewed as AC-DC-AC converter, the asymmetricregular sampling method SPWM(Sine Pulse Width Modulation) is studied and applied in the three-phase matrix AC to AC converter,Based on Matlab/simulink the simulation of the matrix converter with such strategy is carried out. Inductive load simulation is carriedout on the matrix converter prototype. The simulation results verify the workability of the asymmetric regular sampling method SPWMstrategy for matrix converter.展开更多
The present paper deals with the modeling and control of Wind Energy Conversion System WECS based Doubly Fed Induction Generator DFIG using the slip energy recovery principle. The proposed drive system uses a Matrix C...The present paper deals with the modeling and control of Wind Energy Conversion System WECS based Doubly Fed Induction Generator DFIG using the slip energy recovery principle. The proposed drive system uses a Matrix Converter (MC) to transfer the slip energy of the rotor into the mains instead of using cascaded ac-dc-ac converter whilst the stator side is fixed to the grid. Operation at both sub-synchronous and super-synchronous regions is possible with the proposed drive system. The different level control strategies for maximum power point tracking and active-reactive power are discussed. Simulation results of the proposed doubly fed induction generator drive system show the good performance of the control system strategy for both transient and steadystate conditions.展开更多
This project proposes a novel dual-input matrix converter (DIMC) which is used to integrate the output of the wind energy to a power grid. The proposed matrix converter is developed based on the traditional indirect m...This project proposes a novel dual-input matrix converter (DIMC) which is used to integrate the output of the wind energy to a power grid. The proposed matrix converter is developed based on the traditional indirect matrix converter under reverse power flow operation mode, but with its six-switch voltage source converter replaced by a nine-switch configuration followed by the current source inverter (CSI). Matrix electric power conversion topologies and their switch functions are flexible and are used for specific applications. With the additional three switches, the proposed DIMC can provide six input terminals, which make it possible to integrate two independent AC sources from two independent wind turbines into a single grid tied power electronics interface. Commanded currents can be extracted from the two input sources to the grid. The proposed PI control and modulation schemes guaranteed sinusoidal input and output waveforms as well as reduced THD. The simulation results are provided to validate the effectiveness of the proposed control and modulation schemes for the proposed converter.展开更多
In this paper, a hybrid control strategy for a matrix converter fed wind energy conversion system is presented. Since the wind speed may vary, output parameters like power, frequency and voltage may fluctuate. Hence i...In this paper, a hybrid control strategy for a matrix converter fed wind energy conversion system is presented. Since the wind speed may vary, output parameters like power, frequency and voltage may fluctuate. Hence it is necessary to design a system that regulates output parameters, such as voltage and frequency, and thereby provides a constant voltage and frequency output from the wind energy conversion system. Matrix converter is used in the proposed solution as the main power conditioner as a more efficient alternative when compared to traditional back-back converter structure. To control the output voltage, a vector modulation based refined control structure is used. A power tracker is included to maximize the mechanical output power of the turbine. Over current protection and clamp circuit input protection have been introduced to protect the system from over current. It reduces the spikes generated at the output of the converter. The designed system is capable of supplying an output voltage of constant frequency and amplitude within the expected ranges of input during the operation. The matrix converter control using direct modulation method, modified Venturini modulation method and vector modulation method was simulated, the results were compared and it was inferred that vector modulation method was superior to the other two methods. With the proposed technique, voltage transfer ratio and harmonic profile have been improved compared to the other two modulation techniques. The behaviour of the system is corroborated by MATLAB Simulink, and hardware is realized using an FPGA controller. Experimental results are found to be matching with the simulation results.展开更多
In this paper, a new predictive control strategy for current source matrix converter (CSMC) is presented. Proposed predictive control strategy allows for creating output voltages with boost type voltage transfer ratio...In this paper, a new predictive control strategy for current source matrix converter (CSMC) is presented. Proposed predictive control strategy allows for creating output voltages with boost type voltage transfer ratio and desired frequency. The description of predictive control circuit of the CSMC is presented. Furthermore the simulation test results to confirm functionality of the proposed control strategy and converter properties under this strategy are shown.展开更多
a Pole voltage waveforms (VA20 and VA40) for modulation index 0.4 (middle trace is A-phase voltage waveform) x-axis: 1 div.=10ms, y-axis: 1 div.= 100V b Normalized harmonic spectrum for pole voltage of Fig. 9a c A-pha...a Pole voltage waveforms (VA20 and VA40) for modulation index 0.4 (middle trace is A-phase voltage waveform) x-axis: 1 div.=10ms, y-axis: 1 div.= 100V b Normalized harmonic spectrum for pole voltage of Fig. 9a c A-phase current and phase voltage for modulation index 0.4 (reference space vector is in inner layer)展开更多
a Pole voltage waveforms (VA20 and VA40) for modulation index 0.4 (middle trace is A-phase voltage waveform) x-axis: 1 div.=10ms, y-axis: 1 div.= 100V b Normalized harmonic spectrum for pole voltage of Fig. 9a c A-pha...a Pole voltage waveforms (VA20 and VA40) for modulation index 0.4 (middle trace is A-phase voltage waveform) x-axis: 1 div.=10ms, y-axis: 1 div.= 100V b Normalized harmonic spectrum for pole voltage of Fig. 9a c A-phase current and phase voltage for modulation index 0.4 (reference space vector is in inner layer)展开更多
The modular multilevel matrix converter(M3C)is a potential frequency converter for low-frequency AC transmission.However,capacitor voltage control of high-voltage and largecapacity M3C is more difficult,especially for...The modular multilevel matrix converter(M3C)is a potential frequency converter for low-frequency AC transmission.However,capacitor voltage control of high-voltage and largecapacity M3C is more difficult,especially for voltage balancing between branches.To solve this problem,this paper defines sequence circulating components and theoretically analyzes the influence mechanism of different sequence circulating components on branch capacitor voltage.A fully decoupled branch energy balancing control method based on four groups of sequence circulating components is proposed.This method can control capacitor voltages of nine branches in horizontal,vertical and diagonal directions.Considering influences of both circulating current and voltage,a cross decoupled control is designed to improve control precision.Simulation results are taken from a low-frequency transmission system based on PSCAD/EMTDC,and effectiveness and precision of the proposed branch energy balancing control method are verified in the case of nonuniform parameters and an unbalanced power system.展开更多
The crystal structural data of TACE, MMP-1, MMP-2, MMP-3 and MMP-9 were obtained from PDB database, and then their catalytic domains' properties including conformation, molecular surface hydrophobicity and electrosta...The crystal structural data of TACE, MMP-1, MMP-2, MMP-3 and MMP-9 were obtained from PDB database, and then their catalytic domains' properties including conformation, molecular surface hydrophobicity and electrostatic potential were analyzed and compared by using Insight II molecular modeling software. It was found that the conformation and molecular surface hydrophobicity of catalytic domains of TACE and MMPs were not obviously different, but the molecular surface electrostatic potential of catalytic domain of TACE' and MMPs had obvious differences. The findings are helpful in the Rational Drug Design of TACE selective inhibitor.展开更多
文摘This paper discusses a novel boost single-phase active AC-DC converters, named low-end semi-controlled bridge AC-DC converter. By analysis, its topology and principle can be derived from the conventional single-phase power factor corrector ( PFC). But it has also some differences, such as power device positions, inductor type, input voltage waveform detection and induction current detection, so its design is also different. The converter is implemented by employing two current detection approaches, i.e., current transformer detection and shunt resistor detection. Consequently, it can provide a steady DC output voltage with a low voltage ripple, approximately unitary input power factor and 2.5 kW output power. The experimental results show validity of the theoretical analysis.
文摘Based on the output-voltage error function, a novel time discrete modulation technique is proposed for matrix converters (MCs) and time-discrete difference equations of a MC circuit are derived. Switch states of MC are obtained when the output voltage error function is minimized, thus the optimum combination of switch states is derived for the closed-loop control of MC. Meanwhile, advantages of the least calculation workload, the simple process, and the convenient for implementation are brought while switch states are described as space vectors in the α-β coordination system. Simulation and experimental results demonstrate the validity of the time-discrete modulation technique and the feasibility of the control approach.
基金This work was supported in part by the Hunan Provincial Key Laboratory of Power Electronics Equipment and Grid under Grant 2018TP1001in part by the National Natural Science Foundation of China under Grant 61903382,51807206,61933011+1 种基金in part by the Major Project of Changzhutan Self-Dependent Innovation Demonstration Area under Grant 2018XK2002in part by the Natural Science Foundation of Hunan Province,China under Grant 2020JJ5722 and 2020JJ5753.
文摘To reduce the torque ripple in motors resulting from the use of conventional direct torque control(DTC),a model predictive control(MPC)-based DTC strategy for a direct matrix converter-fed induction motor is proposed in this paper.Two new look-up tables are proposed,these are derived on the basis of the control of the electromagnetic torque and stator flux using all the feasible voltage vectors and their associated switching states.Finite control set model predictive control(FCS-MPC)has then been adopted to select the optimal switching state that minimizes the cost function related to the electromagnetic torque.Finally,the experimental results are shown to verify the reduced torque ripple performance of the proposed MPC-based DTC method.
基金National Natural Science Foundation of China(No.61463025)Program for Excellent Team of Scientific Research in Lanzhou Jiaotong University(No.201701)
文摘Employing matrix converter (MC) as driving mode, the strategy of model predictive torque control (MPTC) is proposed for three phase permanent magnet synchronous motor (PMSM) system. MC is applied instead of conventional AC DC AC converter to increase the power factor (PF) of the system input side. MPTC is used to select optimal voltage space vector to enable the system to have satisfactory torque and flux control effect. The resultant MPTC strategy not only makes the MC fed PMSM system operate reliably and have perfect control performance, but also makes the PF of the system input side be 1. Compared with direct torque control (DTC), the proposed MPTC strategy guarantees that MC fed PMSM has better command following characteristics in the presence of variation of load torque and tracking reference speed. Simulation results verify the feasibility and effectiveness of the proposed strategy.
基金supported by the National Natural Science Foundation of China under Grant 61733015,62473322High-Speed Railway Joint Funds of National Natural Science Foundation of China under Grant U1934204.
文摘For dq control strategies in single-phase pulse width modulation(PWM)converters,the-axis current must be created by imaginary axis current estimation(IACE)methods.The estimated error of the-axis current during the transient process causes d-q axis current loops to be incompletely decoupled,thereby affecting the dynamic performance of the current loop.The second-order generalized integrator(SOGI)method suffers from slow dynamic response.The fictive-axis emulation(FAE)method provides fast dynamic response but it is sensitive to circuit parameters.A reference-input(RI)-based IACE method is proposed to overcome the above shortcomings.According to the characteristic that the-axis current loop has no transient process,the-axis current is estimated by the d-q axis reference inputs.This is equivalent to introducing the-axis reference input as a feedforward term into the d-q axis current loop,so the parameter sensitivity problem is solved,and the parameter tuning is not needed.The proposed method can maintain good steadystate performance and significantly improve the dynamic performance of the current loop.Furthermore,it is straightforward and can be easily implemented in digital controllers.Comprehensive hardware-in-the-loop(HIL)experimental comparisons with the SOGI and FAE methods have been conducted to verify the correctness and effectiveness of the proposed RI-based IACE method.
文摘A comprehensive proton-exchange membrane fuel cell stack model was developed and integrated with a two-stage DC/DC boost converter.It was directly coupled to a single-phase(two levels-four pulses)inverter without a transformer.The pulse-width modu-lation signal was used to independently regulate every converter phase.The converter was modelled using a MATLAB®/Simulink®environment and an appropriate voltage control method.The analysis features of the suggested circuit were created and,through established experiments,the simulation results were verified.A single-phase(two levels-four pulses)inverter control circuit was tested and it produced a pure sinusoidal waveform with voltage control.It matches the voltage of the network in terms of amplitude and frequency.A sinusoidal pulse-width modulation approach was performed using a single-phase(two levels-four pulses)pulse-width modulation inverter.The results demonstrated an enhancement in the standard of the output wave and tuned the dead time with a reduction of 63μs compared with 180μs in conventional techniques.
文摘Matrix converter fed motor drive is superior to pulse width modulation inverter drives since it not only provides bi-directional power flow,sinusoidal input/output currents,unity input power factor,but also allows a compact design due to the lack of DC-link capacitors for energy storage.In this paper,model and control of matrix converter fed induction motor drive system are analyzed.A combined control strategy is simplified and improved,which realizes space vector pulse width modulation of matrix converter and rotor flux oriented vector control technique for induction motor drive simultaneously.This control strategy combines the advantages of matrix converter with the good drive performance of vector control technique.Experimental results demonstrate the feasibility and effectiveness of the proposed control strategy.
基金Project(50807002) supported by the National Natural Science Foundation of ChinaProject(SKLD10KM05) supported by Opening Fund of State Key Laboratory of Power System and Generation EquipmentsProject(201206025007) supported by the National Scholarship Fund,China
文摘The behavior of matrix converter(MC) drive systems under the condition of MC short-circuit faults is comprehensively investigated. Two isolation strategies using semiconductors and high speed fuses(HSFs) for MC short-circuit faults are examined and their performances are compared. The behavior of MC drive systems during the fuse action time under different operating conditions is explored. The feasibility of fault-tolerant operation during the fuse action time is also studied. The basic selection laws for the HSFs and the requirements for the passive components of the MC drive system from the point view of short-circuit faults are also discussed. Simulation results are used to demonstrate the feasibility of the proposed isolation strategies.
文摘This paper presents a thorough design and comparative study of two popular control techniques, i.e., classical Proportional Integral (PI) and RST, for Matrix Converters (MCs) in terms of tracking the reference and robustness. The output signal of MCs is directly affected by unbalanced grid voltage. Some research works have attempted to overcome this problem with PI control. However, this technique is known to offer lower performance when it is used in complex and nonlinear systems. On the other hand, RST control offers better performance, even in case of highly nonlinear systems. Therefore, the RST can achieve better performance to overcome the limitation of PI control of nonlinear systems. In this paper, a RST control method is proposed as output current controller to improve the performance of the MC powered by unbalanced grid voltage. The overall operating principle, Venturini modulation strategy of MC, PI control and characteristics of RST are presented.
文摘Based on the topological analysis of three-phase matrix AC to AC conversion circuit, an AC to AC nine-switch matrix isequivalent to rectification part and conversion part. The Matrix converter can be viewed as AC-DC-AC converter, the asymmetricregular sampling method SPWM(Sine Pulse Width Modulation) is studied and applied in the three-phase matrix AC to AC converter,Based on Matlab/simulink the simulation of the matrix converter with such strategy is carried out. Inductive load simulation is carriedout on the matrix converter prototype. The simulation results verify the workability of the asymmetric regular sampling method SPWMstrategy for matrix converter.
文摘The present paper deals with the modeling and control of Wind Energy Conversion System WECS based Doubly Fed Induction Generator DFIG using the slip energy recovery principle. The proposed drive system uses a Matrix Converter (MC) to transfer the slip energy of the rotor into the mains instead of using cascaded ac-dc-ac converter whilst the stator side is fixed to the grid. Operation at both sub-synchronous and super-synchronous regions is possible with the proposed drive system. The different level control strategies for maximum power point tracking and active-reactive power are discussed. Simulation results of the proposed doubly fed induction generator drive system show the good performance of the control system strategy for both transient and steadystate conditions.
文摘This project proposes a novel dual-input matrix converter (DIMC) which is used to integrate the output of the wind energy to a power grid. The proposed matrix converter is developed based on the traditional indirect matrix converter under reverse power flow operation mode, but with its six-switch voltage source converter replaced by a nine-switch configuration followed by the current source inverter (CSI). Matrix electric power conversion topologies and their switch functions are flexible and are used for specific applications. With the additional three switches, the proposed DIMC can provide six input terminals, which make it possible to integrate two independent AC sources from two independent wind turbines into a single grid tied power electronics interface. Commanded currents can be extracted from the two input sources to the grid. The proposed PI control and modulation schemes guaranteed sinusoidal input and output waveforms as well as reduced THD. The simulation results are provided to validate the effectiveness of the proposed control and modulation schemes for the proposed converter.
文摘In this paper, a hybrid control strategy for a matrix converter fed wind energy conversion system is presented. Since the wind speed may vary, output parameters like power, frequency and voltage may fluctuate. Hence it is necessary to design a system that regulates output parameters, such as voltage and frequency, and thereby provides a constant voltage and frequency output from the wind energy conversion system. Matrix converter is used in the proposed solution as the main power conditioner as a more efficient alternative when compared to traditional back-back converter structure. To control the output voltage, a vector modulation based refined control structure is used. A power tracker is included to maximize the mechanical output power of the turbine. Over current protection and clamp circuit input protection have been introduced to protect the system from over current. It reduces the spikes generated at the output of the converter. The designed system is capable of supplying an output voltage of constant frequency and amplitude within the expected ranges of input during the operation. The matrix converter control using direct modulation method, modified Venturini modulation method and vector modulation method was simulated, the results were compared and it was inferred that vector modulation method was superior to the other two methods. With the proposed technique, voltage transfer ratio and harmonic profile have been improved compared to the other two modulation techniques. The behaviour of the system is corroborated by MATLAB Simulink, and hardware is realized using an FPGA controller. Experimental results are found to be matching with the simulation results.
文摘In this paper, a new predictive control strategy for current source matrix converter (CSMC) is presented. Proposed predictive control strategy allows for creating output voltages with boost type voltage transfer ratio and desired frequency. The description of predictive control circuit of the CSMC is presented. Furthermore the simulation test results to confirm functionality of the proposed control strategy and converter properties under this strategy are shown.
文摘a Pole voltage waveforms (VA20 and VA40) for modulation index 0.4 (middle trace is A-phase voltage waveform) x-axis: 1 div.=10ms, y-axis: 1 div.= 100V b Normalized harmonic spectrum for pole voltage of Fig. 9a c A-phase current and phase voltage for modulation index 0.4 (reference space vector is in inner layer)
文摘a Pole voltage waveforms (VA20 and VA40) for modulation index 0.4 (middle trace is A-phase voltage waveform) x-axis: 1 div.=10ms, y-axis: 1 div.= 100V b Normalized harmonic spectrum for pole voltage of Fig. 9a c A-phase current and phase voltage for modulation index 0.4 (reference space vector is in inner layer)
基金supported by National Key R&D Program of China(No.2021YFB2401100).
文摘The modular multilevel matrix converter(M3C)is a potential frequency converter for low-frequency AC transmission.However,capacitor voltage control of high-voltage and largecapacity M3C is more difficult,especially for voltage balancing between branches.To solve this problem,this paper defines sequence circulating components and theoretically analyzes the influence mechanism of different sequence circulating components on branch capacitor voltage.A fully decoupled branch energy balancing control method based on four groups of sequence circulating components is proposed.This method can control capacitor voltages of nine branches in horizontal,vertical and diagonal directions.Considering influences of both circulating current and voltage,a cross decoupled control is designed to improve control precision.Simulation results are taken from a low-frequency transmission system based on PSCAD/EMTDC,and effectiveness and precision of the proposed branch energy balancing control method are verified in the case of nonuniform parameters and an unbalanced power system.
基金This work was supported by a grant from the National Nature Science Foundation of China (Grants No.31371309).
文摘The crystal structural data of TACE, MMP-1, MMP-2, MMP-3 and MMP-9 were obtained from PDB database, and then their catalytic domains' properties including conformation, molecular surface hydrophobicity and electrostatic potential were analyzed and compared by using Insight II molecular modeling software. It was found that the conformation and molecular surface hydrophobicity of catalytic domains of TACE and MMPs were not obviously different, but the molecular surface electrostatic potential of catalytic domain of TACE' and MMPs had obvious differences. The findings are helpful in the Rational Drug Design of TACE selective inhibitor.