As the influence of the ratio of the characteristic value of structural resistance to that of frequent combination effect, K, on the thickness of concrete cover of prestressed concrete (PC) beams and slabs for fire ...As the influence of the ratio of the characteristic value of structural resistance to that of frequent combination effect, K, on the thickness of concrete cover of prestressed concrete (PC) beams and slabs for fire resistance is not considered sufficiently in design criteria for concrete structures in China and other countries at present, numerical analyses were carried out by ANSYS software on unbonded prestressed concrete (UPC) oneway simply-supported and continuous slabs and beams, and bonded PC simply-supported and continuous beams subjected to fire in 186 cases. In the analysis, K, section dimensions and the thickness of concrete cover are regarded as independent variables and some calculation parameters determined by trial and error based on test resuits. Calculation formula for fire endurance of UPC simply-supported and continuous slabs was proposed, and the recommended thicknesses of cover of PC beams and slabs was presented in consideration of the influence of K and section dimensions as well as fire endurance requirements. Comparison analysis of relevant design criterions in China and other countries was performed to verify the rationale of the proposed values.展开更多
A novel scheme of fully immersing water cooling is proposed for a Nd:glass radial slab laser. The slab medium is entirely immersed in the circulating water Ailing the pumping cavity, which enables much lower temperat...A novel scheme of fully immersing water cooling is proposed for a Nd:glass radial slab laser. The slab medium is entirely immersed in the circulating water Ailing the pumping cavity, which enables much lower temperature and reasonably smaller thermal gradient in the slab medium. The radial slab is symmetrically and synchronously pumped by eight flash lamps, and produces multi-output beams with a total energy of 469md. Incoherent beam combination property of the multi-output beams is also investigated. The approach suggested here provides a way of scaling the slab lasers to much higher output levels and also a convenience for beam combinations.展开更多
In order to get the formulae for calculating the equivalent frame width coefficient of reinforced concrete hollow slab-column structures with edge beam,the finite element structural program was used in the elastic ana...In order to get the formulae for calculating the equivalent frame width coefficient of reinforced concrete hollow slab-column structures with edge beam,the finite element structural program was used in the elastic analysis of reinforced concrete hollow slab-column structure with different dimensions to study internal relationship between effective beam width and the frame dimensions.In addition,the formulas for calculating the increasing coefficient of edge beam were also obtained.展开更多
基金Sponsored by the National Natural Science Foundation of China(Grant No.50678050)the Outstanding Youth Science Foundation of Heilongjiang Province(Grant No.2001-8)
文摘As the influence of the ratio of the characteristic value of structural resistance to that of frequent combination effect, K, on the thickness of concrete cover of prestressed concrete (PC) beams and slabs for fire resistance is not considered sufficiently in design criteria for concrete structures in China and other countries at present, numerical analyses were carried out by ANSYS software on unbonded prestressed concrete (UPC) oneway simply-supported and continuous slabs and beams, and bonded PC simply-supported and continuous beams subjected to fire in 186 cases. In the analysis, K, section dimensions and the thickness of concrete cover are regarded as independent variables and some calculation parameters determined by trial and error based on test resuits. Calculation formula for fire endurance of UPC simply-supported and continuous slabs was proposed, and the recommended thicknesses of cover of PC beams and slabs was presented in consideration of the influence of K and section dimensions as well as fire endurance requirements. Comparison analysis of relevant design criterions in China and other countries was performed to verify the rationale of the proposed values.
基金Supported by the Major Innovation Program of Shandong Province under Grant No 2013CXA10006the National Natural Science Foundation of China under Grant No 61108008
文摘A novel scheme of fully immersing water cooling is proposed for a Nd:glass radial slab laser. The slab medium is entirely immersed in the circulating water Ailing the pumping cavity, which enables much lower temperature and reasonably smaller thermal gradient in the slab medium. The radial slab is symmetrically and synchronously pumped by eight flash lamps, and produces multi-output beams with a total energy of 469md. Incoherent beam combination property of the multi-output beams is also investigated. The approach suggested here provides a way of scaling the slab lasers to much higher output levels and also a convenience for beam combinations.
文摘In order to get the formulae for calculating the equivalent frame width coefficient of reinforced concrete hollow slab-column structures with edge beam,the finite element structural program was used in the elastic analysis of reinforced concrete hollow slab-column structure with different dimensions to study internal relationship between effective beam width and the frame dimensions.In addition,the formulas for calculating the increasing coefficient of edge beam were also obtained.