期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
The accuracy and optimal slice thickness of multislice helical computed tomography for right and left ventricular volume measurement 被引量:1
1
作者 崔炜 近藤武 +12 位作者 安野泰史Department of Radiological Technology School of Health Sciences Fujita Health University Toyoake 470-1192 Japan 郭玉印 佐藤贵久 皿井正羲 篠崎仁史 柿澤聡士 杉浦厚司 大岛慶太 片田和廣 菱田仁 《Chinese Medical Journal》 SCIE CAS CSCD 2004年第9期1283-1287,共5页
Background Multislice helical computed tomography (MSCT) has been used to depict coronary anatomy noninvasively, and proved useful for evaluating ventricular function. The aim of our study was to assess the accuracy... Background Multislice helical computed tomography (MSCT) has been used to depict coronary anatomy noninvasively, and proved useful for evaluating ventricular function. The aim of our study was to assess the accuracy of ventricular volume as measured by MSCT.Methods Fourteen human left ventricular (LV) and 15 right ventricular (RV) casts were scanned by MSCT. A series of LV and RV short-axis images were reconstructed later with slice thickness of 2.0 mm, 3.5 mm, 5.0 mm, 7.0 mm, and 10.0 mm. Ventricular volume was calculated by the multislice tomographic Simpson’s method. True LV and RV cast volumes were determined by water displacement. Results Both calculated LV and RV volumes correlated highly with the corresponding true volumes (all r>0.95, P<0.01). But with slice thickness from 2.0 mm to 10.0 mm, MSCT scanning overestimated the corresponding true volume by (3.21±5.95) ml to (12.58±8.56) ml for LV and (10.22±8.45) ml to (23.91±12.24) ml for RV (all P<0.01). There was a very high correlation between the overestimation and the selected slice thickness for both LV and RV volume measurements (r=0.998 and 0.996, P<0.01, respectively). However, when slice thickness was reduced to 5.0 mm, the overestimation for both LV and RV volume measurements became nonsignificant for slice thickness from 2.0 mm to 5.0 mm. Conclusions Both LV and RV volumes can be accurately estimated by MSCT. Thinner slice has more accurate calculated volume. However, 5.0 mm slice thickness is thin enough for an accurate measurement of LV or RV volume. 展开更多
关键词 multislice helical computed tomography ventricular volume CAST slice thickness
原文传递
Direct Slicing Based on Material Performance and Process Parameters for Selective Laser Sintering
2
作者 MA Liang BIN Hong-zan 《International Journal of Plant Engineering and Management》 2006年第4期221-226,共6页
Direct slicing from GAD models to generate sectional contours of the part to be sintered for Selective Laser Sintering (SLS) may overcome inherent disadvantages of using a Stereo Lithography (STL) format. In this ... Direct slicing from GAD models to generate sectional contours of the part to be sintered for Selective Laser Sintering (SLS) may overcome inherent disadvantages of using a Stereo Lithography (STL) format. In this paper, a direct slicing procedure is proposed for Selective Laser Sintering based on material performance and process parameters. Slicing thickness depends on the 3 D geometric model, material performance and process parameters. The relationship among material performance, process parameters and the largest slicing thickness is established using analysis of a sintering temperature field. A dynamic linked library is developed to realize direct slicing from a CAD model. 展开更多
关键词 selective laser sintering( SLS) direct slicing slicing thickness
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部