This paper describes the electric drive for an in-wheel fractional-slot axial flux machine,designed for achieving a wide flux-weakening operating region.By using a slotted stator with fractional-slot windings and addi...This paper describes the electric drive for an in-wheel fractional-slot axial flux machine,designed for achieving a wide flux-weakening operating region.By using a slotted stator with fractional-slot windings and additional cores enclosing end windings,the axial flux machine reaches a wide constant power speed range.The machine is designed for increasing flux-weakening capability while obtaining low harmonic back-electromotive force and low cogging torque.A 10 N.m axial flux machine exhibiting 3 to 1 flux-weakening speed range has been built.A flux-weakening controller,able to maximize the output torque in the flux-weakening region,is designed and implemented.The goodness of both design and control algorithm is proved by experimental tests.However,such a fractional-slot machine has not only advantages.Rotor losses are very high,and they have to be properly considered during the design process.展开更多
For the purpose of motor fault real-time monitoring, this research developed a nano-silicon ni- tride film based magnetic field (MF) sensor, and applied this sensor in MF detection of two common faults. Through experi...For the purpose of motor fault real-time monitoring, this research developed a nano-silicon ni- tride film based magnetic field (MF) sensor, and applied this sensor in MF detection of two common faults. Through experiment, it turned out that arc discharge and slot discharge occur in motor fault produce MF with certain laws. This result proved the feasibility of the sensor and sensing method in MF analysis, and revealed possibility of a new method in fault detection.展开更多
Because the mover and stator of a doubly-fed linear motor are both equipped with three-phase windings, the motor enables contactless energy to be transferred from the stator to the mover. Thus, when a doubly-fed linea...Because the mover and stator of a doubly-fed linear motor are both equipped with three-phase windings, the motor enables contactless energy to be transferred from the stator to the mover. Thus, when a doubly-fed linear motor is used in the linear driving system of trains, neither an overhead line nor a third rail is needed. However, the doubly- fed motor will lead to more severe thrust fluctuation than the unilateral motors. In order to overcome this shortcoming, the thrust fluctuation of the doubly-fed motor should be analyzed. In this paper, an expression for motor thrust is derived. It points out that the slot effect caused by the slotted structure is the main reason for the increase of thrust fluctuation. The method of adopting unequal pole pitch and unequal slot numbers per pole per phase of stator and mover, is proposed to weaken the slot effect when designing the motor slot parameters. Three different motor models are simulated by ANSOFT. The proposed method results in a motor thrust fluctuation coefficient of 8.4%, compared to 49.4% for the conventional method. Therefore, the motor's thrust fluctuation is effectively suppressed by the proposed method.展开更多
基金financed by the Electric'Drive Laboratory,Department of Electrical Engineering,University of Padova,Padova(haly).
文摘This paper describes the electric drive for an in-wheel fractional-slot axial flux machine,designed for achieving a wide flux-weakening operating region.By using a slotted stator with fractional-slot windings and additional cores enclosing end windings,the axial flux machine reaches a wide constant power speed range.The machine is designed for increasing flux-weakening capability while obtaining low harmonic back-electromotive force and low cogging torque.A 10 N.m axial flux machine exhibiting 3 to 1 flux-weakening speed range has been built.A flux-weakening controller,able to maximize the output torque in the flux-weakening region,is designed and implemented.The goodness of both design and control algorithm is proved by experimental tests.However,such a fractional-slot machine has not only advantages.Rotor losses are very high,and they have to be properly considered during the design process.
文摘For the purpose of motor fault real-time monitoring, this research developed a nano-silicon ni- tride film based magnetic field (MF) sensor, and applied this sensor in MF detection of two common faults. Through experiment, it turned out that arc discharge and slot discharge occur in motor fault produce MF with certain laws. This result proved the feasibility of the sensor and sensing method in MF analysis, and revealed possibility of a new method in fault detection.
文摘Because the mover and stator of a doubly-fed linear motor are both equipped with three-phase windings, the motor enables contactless energy to be transferred from the stator to the mover. Thus, when a doubly-fed linear motor is used in the linear driving system of trains, neither an overhead line nor a third rail is needed. However, the doubly- fed motor will lead to more severe thrust fluctuation than the unilateral motors. In order to overcome this shortcoming, the thrust fluctuation of the doubly-fed motor should be analyzed. In this paper, an expression for motor thrust is derived. It points out that the slot effect caused by the slotted structure is the main reason for the increase of thrust fluctuation. The method of adopting unequal pole pitch and unequal slot numbers per pole per phase of stator and mover, is proposed to weaken the slot effect when designing the motor slot parameters. Three different motor models are simulated by ANSOFT. The proposed method results in a motor thrust fluctuation coefficient of 8.4%, compared to 49.4% for the conventional method. Therefore, the motor's thrust fluctuation is effectively suppressed by the proposed method.