In this paper, the X-ray nondestructive test method of small defects in precision weldments with complex structure was presented. To resolve the difficulty of defect segmentation in variable grey image, the image proc...In this paper, the X-ray nondestructive test method of small defects in precision weldments with complex structure was presented. To resolve the difficulty of defect segmentation in variable grey image, the image processing based on Visual Basic programming method was adopted. The methods of automatic contrast and partial grey stretch were used to enhance the X-ray detection image which has relatively low contrast, then automatic threshold method was carried out to segment the two high intensity zones, and weld zones which contain the small defects was extracted. Smoothing and sharpen processing were proceeded on the extracted weld zones, and small defects in X-ray detection image of weldments with complex structure were segmented by using the method of background subtraction in the end. The effects of raster were eliminated, and because of that the image processing was only proceeded on the extracted weld zones, the calculated speed using the above provided algorithm was improved.展开更多
During peripheral nerve transposition repair, if the diameter difference between transposed nerves is large or multiple distal nerves must be repaired at the same time, traditional epineurial neurorrhaphy has the prob...During peripheral nerve transposition repair, if the diameter difference between transposed nerves is large or multiple distal nerves must be repaired at the same time, traditional epineurial neurorrhaphy has the problem of high tension at the suture site, which may even lead to the failure of nerve suture. We investigated whether a small gap bio-sleeve suture with different inner diameters at both ends can be used to repair a 2-mm tibial nerve defect by proximal transposition of the common peroneal nerve in rats and compared the results with the repair seen after epineurial neurorrhaphy. Three months after surgery, neurological function, nerve regeneration, and recovery of nerve innervation muscle were assessed using the tibial nerve function index, neuroelectrophysiological testing, muscle biomechanics and wet weight measurement, osmic acid staining, and hematoxylin-eosin staining. There was no obvious inflammatory reaction and neuroma formation in the tibial nerve after repair by the small gap bio-sleeve suture with different inner diameters at both ends. The conduction velocity, muscle strength, wet muscle weight, cross-sectional area of muscle fibers, and the number of new myelinated nerve fibers in the biosleeve suture group were similar to those in the epineurial neurorrhaphy group. Our findings indicate that small gap bio-sleeve suture with different inner diameters at both ends can achieve surgical suture between nerves of different diameters and promote regeneration and functional recovery of injured peripheral nerves.展开更多
文摘In this paper, the X-ray nondestructive test method of small defects in precision weldments with complex structure was presented. To resolve the difficulty of defect segmentation in variable grey image, the image processing based on Visual Basic programming method was adopted. The methods of automatic contrast and partial grey stretch were used to enhance the X-ray detection image which has relatively low contrast, then automatic threshold method was carried out to segment the two high intensity zones, and weld zones which contain the small defects was extracted. Smoothing and sharpen processing were proceeded on the extracted weld zones, and small defects in X-ray detection image of weldments with complex structure were segmented by using the method of background subtraction in the end. The effects of raster were eliminated, and because of that the image processing was only proceeded on the extracted weld zones, the calculated speed using the above provided algorithm was improved.
基金funded by the National Natural Science Foundation of China,No.31571236,31571235(to YHK and PXZ)National Key Research and Development Program of China,No.2016YFC1101604(to DYZ)+2 种基金National Key Basic Research Program of China(973 Program),No.2014CB542200(to BGJ)Ministry of Education Innovation Program of China,No.IRT_16R01(to BGJ)Beijing Science and Technology New Star Cross Program of China,No.2018019(to PXZ)
文摘During peripheral nerve transposition repair, if the diameter difference between transposed nerves is large or multiple distal nerves must be repaired at the same time, traditional epineurial neurorrhaphy has the problem of high tension at the suture site, which may even lead to the failure of nerve suture. We investigated whether a small gap bio-sleeve suture with different inner diameters at both ends can be used to repair a 2-mm tibial nerve defect by proximal transposition of the common peroneal nerve in rats and compared the results with the repair seen after epineurial neurorrhaphy. Three months after surgery, neurological function, nerve regeneration, and recovery of nerve innervation muscle were assessed using the tibial nerve function index, neuroelectrophysiological testing, muscle biomechanics and wet weight measurement, osmic acid staining, and hematoxylin-eosin staining. There was no obvious inflammatory reaction and neuroma formation in the tibial nerve after repair by the small gap bio-sleeve suture with different inner diameters at both ends. The conduction velocity, muscle strength, wet muscle weight, cross-sectional area of muscle fibers, and the number of new myelinated nerve fibers in the biosleeve suture group were similar to those in the epineurial neurorrhaphy group. Our findings indicate that small gap bio-sleeve suture with different inner diameters at both ends can achieve surgical suture between nerves of different diameters and promote regeneration and functional recovery of injured peripheral nerves.