The voltage source converter based high voltage direct current(VSC-HVDC)system is based on voltage source converter,and its control system is more complex.Also affected by the fast control of power electronics,oscilla...The voltage source converter based high voltage direct current(VSC-HVDC)system is based on voltage source converter,and its control system is more complex.Also affected by the fast control of power electronics,oscillation phenomenon in wide frequency domain may occur.To address the problem of small signal stability of the VSCHVDC system,a converter control strategy is designed to improve its small signal stability,and the risk of system oscillation is reduced by attaching a damping controller and optimizing the control parameters.Based on the modeling of the VSC-HVDC system,the general architecture of the inner and outer loop control of the VSCHVDC converter is established;and the damping controllers for DC control and AC control are designed in the phase-locked loop and the inner and outer loop control parts respectively;the state-space statemodel of the control system is established to analyze its performance.And the electromagnetic transient simulation model is built on the PSCAD/EMTDC simulation platform to verify the accuracy of the small signal model.The influence of the parameters of each control part on the stability of the system is summarized.The main control parts affecting stability are optimized for the phenomenon of oscillation due to changes in operation mode occurring on the AC side due to faults and other reasons,which effectively eliminates system oscillation and improves system small signal stability,providing a certain reference for engineering design.展开更多
Based on the fact that the real inductor and the real capacitor are fractional order in nature and the fractional calculus,the transfer function modeling and analysis of the open-loop Buck converter in a continuous co...Based on the fact that the real inductor and the real capacitor are fractional order in nature and the fractional calculus,the transfer function modeling and analysis of the open-loop Buck converter in a continuous conduction mode(CCM) operation are carried out in this paper.The fractional order small signal model and the corresponding equivalent circuit of the open-loop Buck converter in a CCM operation are presented.The transfer functions from the input voltage to the output voltage,from the input voltage to the inductor current,from the duty cycle to the output voltage,from the duty cycle to the inductor current,and the output impedance of the open-loop Buck converter in CCM operation are derived,and their bode diagrams and step responses are calculated,respectively.It is found that all the derived fractional order transfer functions of the system are influenced by the fractional orders of the inductor and the capacitor.Finally,the realization of the fractional order inductor and the fractional order capacitor is designed,and the corresponding PSIM circuit simulation results of the open-loop Buck converter in CCM operation are given to confirm the correctness of the derivations and the theoretical analysis.展开更多
This paper presents the complete mathematical model and predicts the performance of switched reluctance generator with time average and small signal models. The complete mathematical model is developed in three stages...This paper presents the complete mathematical model and predicts the performance of switched reluctance generator with time average and small signal models. The complete mathematical model is developed in three stages. First, a switching model is developed based on quasi-linear inductance profile. Next, based on the switching behaviour, a time average model is obtained to measure the difference between the excitation and generation time in each switching cycle. Finally, to track control voltage and current wave shapes, a small signal model is designed. The effectiveness of the complete multilevel model combining electrical machine, power converter, load and control with programming language is demonstrated through simulations. A PI controller is used for controlling the voltage of the generator. The results presented show that the controller exhibits accurate tracking control of load voltage under different operating conditions. This demonstrates that the proposed model is able to perform an accurate control of the generated output voltage even in transient situations. The simulation is performed to choose the control parameters and study the performance of switched reluctance generator prior to its actual implementation. Initial experimental results are presented using NI-Data acquisition card to control the output power according to load requirements.展开更多
The hysteresis control combined with PWM control non-inverting buck-boost was proposed to improve the light load efficiency and power density.The constant inductor current control(CICC)was established to mitigate the ...The hysteresis control combined with PWM control non-inverting buck-boost was proposed to improve the light load efficiency and power density.The constant inductor current control(CICC)was established to mitigate the dependence on the external components and device variation and make smooth transition between hysteresis control loop and pulse width modulation(PWM)control loop.The small signal model was deduced for the buck and boost operation mode.The inductor current slope control(ICSC)was proposed to implement the automatic mode transition between buck and boost mode in one switching cycle.The results show that the converter prototype has good dynamic response capability,achieving 94%efficiency and 95%peak efficiency at full 10 A load current.展开更多
Intrinsic stability ofthe heterojunction bipolar transistor (HBT) was analyzed and discussed based on a small signal equivalent circuit model. The stability factor of the HBT device was derived based on a compact T-...Intrinsic stability ofthe heterojunction bipolar transistor (HBT) was analyzed and discussed based on a small signal equivalent circuit model. The stability factor of the HBT device was derived based on a compact T-type small signal equivalent circuit model of the HBT. The effect of the mainly small signal model parameters of the HBT on the stability of the HBT was thoroughly examined. The discipline of parameter optimum to improve the intrinsic stability of the HBT was achieved. The theoretic analysis results of the stability were also used to explain the experimental results of the stability of the HBT and they were verified by the experimental results.展开更多
A small signal coupling model is developed to analyze the coupling between two LNAs. The mutual inductance between the adjacent on-chip inductors is considered responsible for this coupling. A set of formulas have bee...A small signal coupling model is developed to analyze the coupling between two LNAs. The mutual inductance between the adjacent on-chip inductors is considered responsible for this coupling. A set of formulas have been derived to quantitatively predict the coupling effects. Based on our analysis, a quick estimation can be made to see which pair of inductors plays a key role in evaluating the coupling between the LNAs. Source inductors of two LNAs are placed closely while the load inductors are far apart according to the analysis. To validate the proposed theory, two 2 GHz LNAs are fabricated. The LNAs have a peak gain of 18 dB and NF of 1.4 dB. The coupling between the LNAs is –30 dB.展开更多
In general,the power distribution of a parallel inverter is achieved by the use of droop control in a microgrid system,which consists of PV inverters and non-regeneration energy source inverters without energy storage...In general,the power distribution of a parallel inverter is achieved by the use of droop control in a microgrid system,which consists of PV inverters and non-regeneration energy source inverters without energy storage devices in an islanded mode.If the shared load power is no more than the available maximum PV inverter output power,then there is a power waste for the PV inverter.In addition,due to the intermittency of PV sources,the system may become unstable if the shared load power is more than the available maximum power output of the PV(MPO-PV)inverter.Therefore,in order to avoid power waste and potential instability caused by insufficient PV power by traditional droop control,this paper recommends an improved droop control scheme to maximize the power output of PV units.As required by the load,the remaining power is composed of the other inverters,which can effectively improve the utilization rating of renewable energy sources and system stability.At the same time,according to the system stability analysis based on small signal modeling,it has been designed around the droop coefficients of the improved droop control loop.In the end,the simulation and experimental results show that the suggested scheme has a varied validity and robustness.展开更多
基金supported by Research on the Oscillation Mechanism and Suppression Strategy of Yu-E MMC-HVDC Equipment and System(2021Yudian Technology 33#).
文摘The voltage source converter based high voltage direct current(VSC-HVDC)system is based on voltage source converter,and its control system is more complex.Also affected by the fast control of power electronics,oscillation phenomenon in wide frequency domain may occur.To address the problem of small signal stability of the VSCHVDC system,a converter control strategy is designed to improve its small signal stability,and the risk of system oscillation is reduced by attaching a damping controller and optimizing the control parameters.Based on the modeling of the VSC-HVDC system,the general architecture of the inner and outer loop control of the VSCHVDC converter is established;and the damping controllers for DC control and AC control are designed in the phase-locked loop and the inner and outer loop control parts respectively;the state-space statemodel of the control system is established to analyze its performance.And the electromagnetic transient simulation model is built on the PSCAD/EMTDC simulation platform to verify the accuracy of the small signal model.The influence of the parameters of each control part on the stability of the system is summarized.The main control parts affecting stability are optimized for the phenomenon of oscillation due to changes in operation mode occurring on the AC side due to faults and other reasons,which effectively eliminates system oscillation and improves system small signal stability,providing a certain reference for engineering design.
基金Project supported by the National Natural Science Foundation of China (Grant No. 51007068)the Specialized Research Fund for the Doctoral Program of Higher Education of China (Grant No. 20100201120028)+2 种基金the Natural Science Basic Research Plan in Shaanxi Province of China (Grant No. 2012JQ7026)the Fundamental Research Funds for the Central Universities of China (Grant No. 2012jdgz09)the State Key Laboratory of Electrical Insulation and Power Equipment of China (Grant No. EIPE12303)
文摘Based on the fact that the real inductor and the real capacitor are fractional order in nature and the fractional calculus,the transfer function modeling and analysis of the open-loop Buck converter in a continuous conduction mode(CCM) operation are carried out in this paper.The fractional order small signal model and the corresponding equivalent circuit of the open-loop Buck converter in a CCM operation are presented.The transfer functions from the input voltage to the output voltage,from the input voltage to the inductor current,from the duty cycle to the output voltage,from the duty cycle to the inductor current,and the output impedance of the open-loop Buck converter in CCM operation are derived,and their bode diagrams and step responses are calculated,respectively.It is found that all the derived fractional order transfer functions of the system are influenced by the fractional orders of the inductor and the capacitor.Finally,the realization of the fractional order inductor and the fractional order capacitor is designed,and the corresponding PSIM circuit simulation results of the open-loop Buck converter in CCM operation are given to confirm the correctness of the derivations and the theoretical analysis.
文摘This paper presents the complete mathematical model and predicts the performance of switched reluctance generator with time average and small signal models. The complete mathematical model is developed in three stages. First, a switching model is developed based on quasi-linear inductance profile. Next, based on the switching behaviour, a time average model is obtained to measure the difference between the excitation and generation time in each switching cycle. Finally, to track control voltage and current wave shapes, a small signal model is designed. The effectiveness of the complete multilevel model combining electrical machine, power converter, load and control with programming language is demonstrated through simulations. A PI controller is used for controlling the voltage of the generator. The results presented show that the controller exhibits accurate tracking control of load voltage under different operating conditions. This demonstrates that the proposed model is able to perform an accurate control of the generated output voltage even in transient situations. The simulation is performed to choose the control parameters and study the performance of switched reluctance generator prior to its actual implementation. Initial experimental results are presented using NI-Data acquisition card to control the output power according to load requirements.
文摘The hysteresis control combined with PWM control non-inverting buck-boost was proposed to improve the light load efficiency and power density.The constant inductor current control(CICC)was established to mitigate the dependence on the external components and device variation and make smooth transition between hysteresis control loop and pulse width modulation(PWM)control loop.The small signal model was deduced for the buck and boost operation mode.The inductor current slope control(ICSC)was proposed to implement the automatic mode transition between buck and boost mode in one switching cycle.The results show that the converter prototype has good dynamic response capability,achieving 94%efficiency and 95%peak efficiency at full 10 A load current.
文摘Intrinsic stability ofthe heterojunction bipolar transistor (HBT) was analyzed and discussed based on a small signal equivalent circuit model. The stability factor of the HBT device was derived based on a compact T-type small signal equivalent circuit model of the HBT. The effect of the mainly small signal model parameters of the HBT on the stability of the HBT was thoroughly examined. The discipline of parameter optimum to improve the intrinsic stability of the HBT was achieved. The theoretic analysis results of the stability were also used to explain the experimental results of the stability of the HBT and they were verified by the experimental results.
基金supported by the National Natural Science Foundation of China(No.61401025)
文摘A small signal coupling model is developed to analyze the coupling between two LNAs. The mutual inductance between the adjacent on-chip inductors is considered responsible for this coupling. A set of formulas have been derived to quantitatively predict the coupling effects. Based on our analysis, a quick estimation can be made to see which pair of inductors plays a key role in evaluating the coupling between the LNAs. Source inductors of two LNAs are placed closely while the load inductors are far apart according to the analysis. To validate the proposed theory, two 2 GHz LNAs are fabricated. The LNAs have a peak gain of 18 dB and NF of 1.4 dB. The coupling between the LNAs is –30 dB.
文摘In general,the power distribution of a parallel inverter is achieved by the use of droop control in a microgrid system,which consists of PV inverters and non-regeneration energy source inverters without energy storage devices in an islanded mode.If the shared load power is no more than the available maximum PV inverter output power,then there is a power waste for the PV inverter.In addition,due to the intermittency of PV sources,the system may become unstable if the shared load power is more than the available maximum power output of the PV(MPO-PV)inverter.Therefore,in order to avoid power waste and potential instability caused by insufficient PV power by traditional droop control,this paper recommends an improved droop control scheme to maximize the power output of PV units.As required by the load,the remaining power is composed of the other inverters,which can effectively improve the utilization rating of renewable energy sources and system stability.At the same time,according to the system stability analysis based on small signal modeling,it has been designed around the droop coefficients of the improved droop control loop.In the end,the simulation and experimental results show that the suggested scheme has a varied validity and robustness.