Death toll by smoke in fire is estimated at 70% which emphasizes the importance of smoke control system to deal with the fire smoke. In advanced countries, the studies on method to prevent smoke spread by forming the ...Death toll by smoke in fire is estimated at 70% which emphasizes the importance of smoke control system to deal with the fire smoke. In advanced countries, the studies on method to prevent smoke spread by forming the air curtain using high velocity jet flow are underway now. In this study, a linear-jet type air curtain system is proposed to prevent the smoke spread and analysis of flow characteristics of pressure chamber, which is the core component, is conducted through numerical analysis and experimental approach. Consequently, the pressure was increased in 2D functional way to input air flowrate and about 595 Pa pressure was formed at pressure chamber inlet in response to 30 m/s nozzle jet velocity.展开更多
Spread of fire smoke in the elevator shaft of a high-rise building is influ- enced by many driving facts. We simulate smoke spreading in the elevator shaft, stair room, and pre-chamber with and without different suppl...Spread of fire smoke in the elevator shaft of a high-rise building is influ- enced by many driving facts. We simulate smoke spreading in the elevator shaft, stair room, and pre-chamber with and without different supplied pressurized air. The simulation shows that smoke moves very fast in the elevator shaft. When a 12 floor high-rise building is in fire, smoke can fill up the elevator shaft in less than 1.5 min after a fire started, temperature in the elevator shaft can be higher than 187℃ in 5 rain, and the concentration of CO can also reach a high level. The elevator shaft has a very low visibility in less than about 100 s.展开更多
The apartment fire tests comprise a set of two full-scale fire experiments in a dwelling building made from pre-fabricated concrete elements in April 2013. Two apartments were nearly identically furnished and fully in...The apartment fire tests comprise a set of two full-scale fire experiments in a dwelling building made from pre-fabricated concrete elements in April 2013. Two apartments were nearly identically furnished and fully instrumented with thermocouples, video cameras and gas extraction probes. The apartments were ignited successively whereupon the fire in the second apartment developed freely to post-flashover conditions and got the main focus in this report. The apartment was completely furnished with contemporary furniture and objects, and had an average fire load density for residential occupancy. A full description of the fire load, ventilation conditions and instrumentation are provided. The focus of this report is primarily to obtain conclusions on the horizontal spread of smoke throughout the apartment during the fire growth period. Velocities of smoke spreading were measured to be in the range below 0.05 m/s which means that the smoke migrated over the longest distance throughout the apartment for about 3 to 4 minutes while the flame did not leave the initial fire room. The main aim of the experiments was to collect a comprehensive set of data from a realistic and contemporary fire scenario to validate numerical simulations.展开更多
文摘Death toll by smoke in fire is estimated at 70% which emphasizes the importance of smoke control system to deal with the fire smoke. In advanced countries, the studies on method to prevent smoke spread by forming the air curtain using high velocity jet flow are underway now. In this study, a linear-jet type air curtain system is proposed to prevent the smoke spread and analysis of flow characteristics of pressure chamber, which is the core component, is conducted through numerical analysis and experimental approach. Consequently, the pressure was increased in 2D functional way to input air flowrate and about 595 Pa pressure was formed at pressure chamber inlet in response to 30 m/s nozzle jet velocity.
基金supported by the National Basic Research Program of China(2012CB719703)
文摘Spread of fire smoke in the elevator shaft of a high-rise building is influ- enced by many driving facts. We simulate smoke spreading in the elevator shaft, stair room, and pre-chamber with and without different supplied pressurized air. The simulation shows that smoke moves very fast in the elevator shaft. When a 12 floor high-rise building is in fire, smoke can fill up the elevator shaft in less than 1.5 min after a fire started, temperature in the elevator shaft can be higher than 187℃ in 5 rain, and the concentration of CO can also reach a high level. The elevator shaft has a very low visibility in less than about 100 s.
文摘The apartment fire tests comprise a set of two full-scale fire experiments in a dwelling building made from pre-fabricated concrete elements in April 2013. Two apartments were nearly identically furnished and fully instrumented with thermocouples, video cameras and gas extraction probes. The apartments were ignited successively whereupon the fire in the second apartment developed freely to post-flashover conditions and got the main focus in this report. The apartment was completely furnished with contemporary furniture and objects, and had an average fire load density for residential occupancy. A full description of the fire load, ventilation conditions and instrumentation are provided. The focus of this report is primarily to obtain conclusions on the horizontal spread of smoke throughout the apartment during the fire growth period. Velocities of smoke spreading were measured to be in the range below 0.05 m/s which means that the smoke migrated over the longest distance throughout the apartment for about 3 to 4 minutes while the flame did not leave the initial fire room. The main aim of the experiments was to collect a comprehensive set of data from a realistic and contemporary fire scenario to validate numerical simulations.