期刊文献+
共找到1,845篇文章
< 1 2 93 >
每页显示 20 50 100
The Use of Models to Evaluate Corrosion Effects on Mild Steel Heat Exchanger in Water and Mono Ethanol Amine (MEA)
1
作者 Ojong Elias Ojong Jaja Zina +6 位作者 Wosu Chimene Omeke Ana Anakri Ekpenyong Dadet Wilson Anaba Catherine Uloma Emenike Aguma Sedi Patrick Forwah Jacques Ndeh 《Advances in Chemical Engineering and Science》 2023年第4期336-350,共15页
Heat exchanger is an important equipment used in process industries for cooling and heating purposes. Its design configuration which involves the flow of cold and hot fluids within the exchanger subjects it to corrosi... Heat exchanger is an important equipment used in process industries for cooling and heating purposes. Its design configuration which involves the flow of cold and hot fluids within the exchanger subjects it to corrosion attack. The article utilized the principle of mass and energy conservation in the development of weight and temperature models to study the effect of corrosion on mild steel coupon inside the exchanger containing water and Mono ethanol amine (MEA). The models developed were resolved analytically using Laplace Transform and simulated using Excel as simulation tool and data obtained from experiment in the laboratory to obtain profiles of weight loss and temperature as a function of time. The weight loss and performance of mild steel under various corrosive conditions were examined which indicates the effect of corrosion on the mild steel heat exchanger in water and MEA media. The result shows that water is more corrosive than MEA at higher temperatures and at lower temperatures of 35°C and 1 atm, MEA has inhibitive properties than water as indicated by the weight loss result with time. The comparative analysis between the results obtained from the model simulation and experimental results shows that the result obtained from the model is more reliable and demonstrated better performance characteristics as it clearly shows mild steel heat exchanger experiences more corrosive effect in water medium than MEA at higher temperatures. And at lower temperatures, MEA becomes more inhibitive and less corrosive than water. The model simulation results correlate with various literatures and hence, it is valid for future referencing. 展开更多
关键词 Model Corrosion effect Heat exchanger Simulation Media Mild Steel COUPON
下载PDF
Exchange Bias Effect in Phase Separated La0.33Pr0.34Ca0.33MnO3 Thin Films
2
作者 李惠 李林 +2 位作者 成龙 梁海星 曾长淦 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2014年第4期475-478,J0002,共5页
Exchange bias effect is observed in the phase separated La0.33Pr0.34Ca0.33MnO3 thin films. High exchange bias field of about 1 kOe is achieved at 4 K. The exchange bias effect in La0.33Pr0.34Ca0.33MnO3 thin films migh... Exchange bias effect is observed in the phase separated La0.33Pr0.34Ca0.33MnO3 thin films. High exchange bias field of about 1 kOe is achieved at 4 K. The exchange bias effect in La0.33Pr0.34Ca0.33MnO3 thin films might originate from the intrinsic phase separation of the La0.33Pr0.34Ca0.33MnO3 or surface effect. The dependence of exchange bias effect on temperature, cooling field, and thickness is also investigated. This work would open an avenue to the application in the magnetic memory devices based on the phase separated manganites. 展开更多
关键词 exchange bias Phase separation Pulse laser deposition MANGANITES Training effect
下载PDF
THE STEPWISE EXCHANGE ACTION AND STERIC HINDRANCE EFFECT OF ORGANIC PHENOLS ON CLAYS IN SEAWATER 被引量:3
3
作者 杨桂朋 张正斌 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 1994年第1期61-70,共10页
The exchange action of six types of organic phenols on clay surfaces in seawater is systematically studied in this work. The following significant conclusions are drawn from the experiments. (1) The interaction of org... The exchange action of six types of organic phenols on clay surfaces in seawater is systematically studied in this work. The following significant conclusions are drawn from the experiments. (1) The interaction of organic phenols with montmorillonite, illite and kaolinite in seawater is monovalent anion exchage.(2) Their isotherms of stepwise exchage on clay surfaces belong to the Langmuir type or stepwise type.(3) The discovery of the"steric hindrance effects of stepwise exchange of organic phenols on clays surfaces", and revelation of an exchange mechanisrn diffeient from that in references are the greatest achieverments in this work. 展开更多
关键词 organic PHENOLS clays exchange isothenns STEPWISE exchange STERIC hindrance effect
下载PDF
Efficiency and Effectiveness Concepts Applied in Shell and Tube Heat Exchanger Using Ethylene Glycol-Water Based Fluid in the Shell with Nanoparticles of Copper Oxide (CuO) 被引量:2
4
作者 Élcio Nogueira 《Journal of Materials Science and Chemical Engineering》 2020年第8期1-12,共12页
This article consists of an analytical solution for obtaining the outlet temperatures of the hot and cold fluids in a shell and tube heat exchanger. The system analyzed through the concepts of efficiency, effectivenes... This article consists of an analytical solution for obtaining the outlet temperatures of the hot and cold fluids in a shell and tube heat exchanger. The system analyzed through the concepts of efficiency, effectiveness (<em>ε</em>-<em>NTU</em>), and irreversibility consisted of a shell and tube heat exchanger, with cold nanofluid flowing in the shell and hot water flowing in the tube. The nanofluid consists of 50% of ethylene glycol and water as the base fluid and copper oxide (CuO) nanoparticles in suspension. The volume fractions of the nanoparticles range from 0.1 to 0.5. The flow rate in the nanofluid ranges from 0.0331 to 0.0568 Kg/s, while two mass flow rates, from 0.0568 and 0.5 Kg/s, for the hot fluid, are used as parameters for analysis. Results for the efficiency, effectiveness, irreversibility, heat transfer rate, and outlet temperatures for cold and hot fluids were obtained graphically. The flow laminarization effect was observed through the results obtained and had significant relevance in the results. 展开更多
关键词 EFFICIENCY effectIVENESS Shell and Tube Heat exchanger NANOFLUID Ethylene Glycol
下载PDF
Thermal performance analysis of borehole size effect on geothermal heat exchanger 被引量:2
5
作者 CHOI Hoon-ki YOO Geun-jong +2 位作者 LIM Kyung-bin LEE Sang-hoon LEE Chang-hee 《Journal of Central South University》 SCIE EI CAS 2012年第12期3524-3529,共6页
Thermal performance was the most important factor in the development of borehole heat exchanger utilizing geothermal energy. The thermal performance was affected by many different design parameters, such as configurat... Thermal performance was the most important factor in the development of borehole heat exchanger utilizing geothermal energy. The thermal performance was affected by many different design parameters, such as configuration type and borehole size of geothermal heat exchanger. These eventually determined the operation and cost efficiency of the geothermal heat exchanger system. The main purpose of this work was to assess the thermal performance of geother^nal heat exchanger with variation of borehole sizes and numbers of U-tubes inside a borehole. For this, a thermal response test rig was established with line-source theory. The thermal response test was performed with in-line variable input heat source. Effective thermal conductivity and thermal resistance were obtained from the measured data. From the measurement, the effective thermal conductivity is found to have similar values for two- pair type (4 U-tubes) and three-pair type (6 U-tubes) borehole heat exchanger systems indicating similar heat transfer ability. Meanwhile, the thermal resistance shows lower value for the three-pair type compared to the two-pair type. Measured data based resistance have lower value compared to computed result from design programs. Overall comparison finds better thermal performance for the three-pair type, however, fluctuating temperature variation indicates complex flow behavior inside the borehole and requires further study on flow characteristics. 展开更多
关键词 large size borehole heat exchanger thermal response test effective thermal conductivity thermal resistance BOREHOLE
下载PDF
Efficiency and Effectiveness Thermal Analysis of the Shell and Helical Coil Tube Heat Exchanger Used in an Aqueous Solution of Ammonium Nitrate Solubility (<i>ANSOL</i>) with 20% H<sub>2</sub>O and 80% <i>AN</i> 被引量:2
6
作者 Élcio Nogueira 《Journal of Materials Science and Chemical Engineering》 2021年第6期24-45,共22页
The case study is about obtaining the flow rate and saturation temperature of steam that makes it possible to heat a solution of water and ammonia nitrate (<i>ANSOL</i>) in a shell and helical coil tube he... The case study is about obtaining the flow rate and saturation temperature of steam that makes it possible to heat a solution of water and ammonia nitrate (<i>ANSOL</i>) in a shell and helical coil tube heat exchanger, within a time interval, without that the crystallization of the <i>ANSOL</i> solution occurs. The desired production per batch of the solution is 5750 kg in 80 minutes. The analysis uses the concepts of efficiency and effectiveness to determine the heat transfer rate and temperature profiles that satisfy the imposed condition within a certain degree of safety and with the lowest possible cost in steam generation. Intermediate quantities necessary to reach the objective are the Reynolds number, Nusselt number, and global heat transfer coefficient for the shell and helical coil tube heat exchanger. Initially, the water is heated for a specified period and, subsequently, the ammonium nitrate is added to a given flow in a fixed mass flow rate. 展开更多
关键词 Thermal Efficiency Thermal effectiveness Shell and Helical Coil Tube Heat exchanger Ammonium Nitrate
下载PDF
Localized Theoretical Analysis of Thermal Performance of Individually Finned Heat Pipe Heat Exchanger for Air Conditioning with Freon R404A as Working Fluid
7
作者 Élcio Nogueira 《Journal of Materials Science and Chemical Engineering》 2023年第8期61-85,共17页
This work contributes to the improvement of energy-saving in air conditioning systems. The objective is to apply the thermal efficiency of heat exchangers for localized determination of the thermal performance of heat... This work contributes to the improvement of energy-saving in air conditioning systems. The objective is to apply the thermal efficiency of heat exchangers for localized determination of the thermal performance of heat exchangers with individually finned heat pipes. The fundamental parameters used for performance analysis were the number of fins per heat pipe, the number of heat pipes, the inlet temperatures, and the flow rates of hot and cold fluids. The heat exchanger under analysis uses Freon 404A as a working fluid in an air conditioning system for cooling in the Evaporator and energy recovery in the Condenser. The theoretical model is localized and applied individually to the Evaporator, Condenser, and heat exchanger regions. The results obtained through the simulation are compared with experimental results that use a global approach for the heat exchanger. The thermal quantities obtained through the theoretical model in the mentioned regions are air velocity, Nusselt number, thermal effectiveness, heat transfer rate, and outlet temperature. The comparisons made with global experimental results are in excellent agreement, demonstrating that the localized theoretical approach developed is consistent and can be used as a comprehensive analysis tool for heat exchangers using heat pipes. 展开更多
关键词 Individually Finned Heat Pipe Heat exchanger Thermal Efficiency Thermal effectiveness Air Conditioning Freon R404A
下载PDF
Localized Theoretical Analysis of Thermal Performance of Individually Finned Heat Pipe Heat Exchanger for Air Conditioning with Freon R404A as Working Fluid
8
作者 Élcio Nogueira 《Journal of Modern Physics》 2023年第8期61-85,共6页
This work contributes to the improvement of energy-saving in air conditioning systems. The objective is to apply the thermal efficiency of heat exchangers for localized determination of the thermal performance of heat... This work contributes to the improvement of energy-saving in air conditioning systems. The objective is to apply the thermal efficiency of heat exchangers for localized determination of the thermal performance of heat exchangers with individually finned heat pipes. The fundamental parameters used for performance analysis were the number of fins per heat pipe, the number of heat pipes, the inlet temperatures, and the flow rates of hot and cold fluids. The heat exchanger under analysis uses Freon 404A as a working fluid in an air conditioning system for cooling in the Evaporator and energy recovery in the Condenser. The theoretical model is localized and applied individually to the Evaporator, Condenser, and heat exchanger regions. The results obtained through the simulation are compared with experimental results that use a global approach for the heat exchanger. The thermal quantities obtained through the theoretical model in the mentioned regions are air velocity, Nusselt number, thermal effectiveness, heat transfer rate, and outlet temperature. The comparisons made with global experimental results are in excellent agreement, demonstrating that the localized theoretical approach developed is consistent and can be used as a comprehensive analysis tool for heat exchangers using heat pipes. 展开更多
关键词 Individually Finned Heat Pipe Heat exchanger Thermal Efficiency Thermal effectiveness Air Conditioning Freon R404A
下载PDF
Spin glassy behavior and large exchange bias effect in cubic perovskite Ba0.8Sr0.2FeO3-δ
9
作者 Yu-Xuan Liu Zhe-Hong Liu +5 位作者 Xu-Bin Ye Xu-Dong Shen Xiao Wang Bo-Wen Zhou Guang-Hui Zhou You-Wen Long 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第6期433-437,共5页
A single-phase iron oxideBa0.8Sr0.2FeO3-δwith a simple cubic perovskite structure in Pm-3 m symmetry is successfully synthesized by a solid-state reaction method in O2 flow. The oxygen content is determined to be abo... A single-phase iron oxideBa0.8Sr0.2FeO3-δwith a simple cubic perovskite structure in Pm-3 m symmetry is successfully synthesized by a solid-state reaction method in O2 flow. The oxygen content is determined to be about 2.81, indicating the formation of mixed Fe3+and Fe4+charge states with a disorder fashion. As a result, the compound shows small-polaron conductivity behavior, as well as spin glassy features arising from the competition between the ferromagnetic interaction and the antiferromagnetic interaction. Moreover, the competing interactions also give rise to a remarkable exchange bias effect in Ba0.8 Sr0.2 FeO2.81, providing an opportunity to use it in spin devices. 展开更多
关键词 high-pressure synthesis exchange BIAS effect SPIN glass
下载PDF
Internal Polarization Field Induced Hydroxyl Spillover Effect for Industrial Water Splitting Electrolyzers
10
作者 Jingyi Xie Fuli Wang +3 位作者 Yanan Zhou Yiwen Dong Yongming Chai Bin Dong 《Nano-Micro Letters》 SCIE EI CAS CSCD 2024年第2期438-449,共12页
The formation of multiple oxygen intermediates supporting efficient oxygen evolution reaction(OER)are affinitive with hydroxyl adsorption.However,ability of the catalyst to capture hydroxyl and maintain the continuous... The formation of multiple oxygen intermediates supporting efficient oxygen evolution reaction(OER)are affinitive with hydroxyl adsorption.However,ability of the catalyst to capture hydroxyl and maintain the continuous supply at active sits remains a tremendous challenge.Herein,an affordable Ni2P/FeP2 heterostructure is presented to form the internal polarization field(IPF),arising hydroxyl spillover(HOSo)during OER.Facilitated by IPF,the oriented HOSo from FeP2 to Ni2P can activate the Ni site with a new hydroxyl transmission channel and build the optimized reaction path of oxygen intermediates for lower adsorption energy,boosting the OER activity(242 mV vs.RHE at 100 mA cm-2)for least 100 h.More interestingly,for the anion exchange membrane water electrolyzer(AEMWE)with low concentration electrolyte,the advantage of HOSo effect is significantly amplified,delivering 1 A cm^(-2)at a low cell voltage of 1.88 V with excellent stability for over 50 h. 展开更多
关键词 Hydroxyl spillover effect Internal polarization field HETEROSTRUCTURE Oxygen reduction reaction Anion exchange membrane water electrolysis
下载PDF
Asymmetric exchange bias training effect in spin glass(FeAu)/FeNi bilayers
11
作者 芮文彬 何茂诚 +7 位作者 游彪 时钟 周仕明 肖明文 高远 张维 孙力 杜军 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第10期513-518,共6页
A significant exchange bias (EB) traimng ettect has been observea in sputter deposited FeAu/FeNi bilayers, wherein the exchange field (HE) exhibits a special sign-changeable temperature dependence. Very interestin... A significant exchange bias (EB) traimng ettect has been observea in sputter deposited FeAu/FeNi bilayers, wherein the exchange field (HE) exhibits a special sign-changeable temperature dependence. Very interestingly, despite the absence of multiple easy axes in the FeAu spin glass (SG) layer, HE drops abruptly between the first and second magnetic cycles, which is followed by a more gradual continuous change in the subsequent cycles. This training behavior cannot be described by the empirical n-1/2 law because of the asymmetric magnetization reversal processes. We propose modifying Binek's model to include the asymmetric changes of the pinning SG spins at the descending and ascending branches. This new model successfully describes the EB training effect in FeAu/FeNi bilayers. 展开更多
关键词 exchange bias training effect spin glass
下载PDF
Microwave Irradiation Effect on the Ligand Exchange Reaction between Ferrocene and Heterocycles
12
作者 Yutaka Okada Atsushi Niou Shinya Nakano 《Green and Sustainable Chemistry》 2017年第2期95-100,共6页
The ligand exchange reaction is a typical reaction of ferrocenes. This reaction proceeds via the abstraction of a cyclopentadienyl ring by a Lewis acid followed by coordination of an aromatic compound to the resulting... The ligand exchange reaction is a typical reaction of ferrocenes. This reaction proceeds via the abstraction of a cyclopentadienyl ring by a Lewis acid followed by coordination of an aromatic compound to the resulting species. This reaction with conventional heating requires a long reaction time. Furthermore, the reactions with heterocycles are lower than those with the corresponding hydrocarbons, and do not produce any products in some cases. In this paper, the ligand exchange reaction of ferrocene and a heterocyclic aromatic compound during microwave irradiation and its effect are discussed. As a result, for some heterocycles, the decrease in the reaction time was confirmed. Furthermore, under the microwave irradiation conditions, the tendency in which the difference in their reactivities became low was confirmed. 展开更多
关键词 MICROWAVE IRRADIATION effect FERROCENE LIGAND exchange HETEROCYCLE
下载PDF
Charge Exchange Effect on Space-Charge-Limited Current Densities in Ion Diode
13
作者 石磊 《Plasma Science and Technology》 SCIE EI CAS CSCD 2002年第2期1239-1242,共4页
The article theoretically studied the charge-exchange effects on space charge limitedelectron and ion current densities of non-relativistic one-dimensional slab ion diode, and comparedwith those of without charge exch... The article theoretically studied the charge-exchange effects on space charge limitedelectron and ion current densities of non-relativistic one-dimensional slab ion diode, and comparedwith those of without charge exchange. 展开更多
关键词 Charge exchange effect on Space-Charge-Limited Current Densities in Ion Diode THAN
下载PDF
Do the RMB exchange rate and global commodity prices have asymmetric or symmetric effects on China’s stock prices?
14
作者 Shaobo Long Mengxue Zhang +1 位作者 Keaobo Li Shuyu Wu 《Financial Innovation》 2021年第1期1030-1050,共21页
With the rapid expansion of the RMB exchange rate’s floating range,the effects of the RMB exchange rate and global commodity price changes on China’s stock prices are likely to increase.This study uses both auto reg... With the rapid expansion of the RMB exchange rate’s floating range,the effects of the RMB exchange rate and global commodity price changes on China’s stock prices are likely to increase.This study uses both auto regressive distributed lag(ARDL)and nonlinear ARDL(NARDL)approaches to explore the symmetric and asymmetric effects of the RMB exchange rate and global commodity prices on China’s stock prices.Our findings show that without considering the critical variable of global commodity prices,there is no cointegration relationship between the RMB exchange rate and China’s stock prices,and the coefficient of the RMB exchange rate is not statistically significant.However,when we introduce global commodity prices into the NARDL model,the result shows that the RMB exchange rate has a negative effect on China’s stock prices,that there indeed exists a long-run cointegration relationship among the RMB exchange rate,global commodity prices,and stock prices in the NARDL model,and that global commodity price changes have an asymmetric effect on China’s stock prices in the long run.Specifically,China’s stock prices are more sensitive to increases than decreases in global commodity prices.Thus,increases in global commodity prices cause China’s stock prices to decline sharply.In contrast,the same magnitude of decline in global commodity prices induces a smaller increase in China’s stock prices. 展开更多
关键词 RMB exchange rate Global commodity prices China’s stock prices Asymmetric effects
下载PDF
On the Isotope-Like Effect for High-T<sub>c</sub>Superconductors in the Scenario of 2-Phonon Exchange Mechanism for Pairing
15
作者 G. P. Malik 《World Journal of Condensed Matter Physics》 2018年第3期109-114,共6页
By generalizing the isotope effect for elemental superconductors (SCs) to the case of pairing in the 2-phonon exchange mechanism for composite SCs, we give here an explanation of the well-known increase in the critica... By generalizing the isotope effect for elemental superconductors (SCs) to the case of pairing in the 2-phonon exchange mechanism for composite SCs, we give here an explanation of the well-known increase in the critical temperature (Tc) of Bi2Sr2CaCu2O8 from 95 K to 110 K and of Bi2Sr2Ca2Cu3O10 from 105 to 115 - 125 K when Bi and Sr in these are replaced by Tl and Ba, respectively. On this basis, we also give the estimated Tcs of some hypothetical SCs, assuming that they may be fabricated by substitutions similar to Bi → Tl and Sr → Ba. 展开更多
关键词 Isotope-Like effect 2-Phonon exchange Mechanism Bi- and Tl-Based High-Tc SCS Suggestions for New Substitutions for Further Enhancement of Tc of the Bi-Based SCS
下载PDF
Efficiency and Effectiveness Method versus ε-NTU Method with Application in Finned Flat Tube Compact Heat Exchanger with Water-Ethylene Glycol as Nanofluid Base of Iron Oxide Nanoparticles
16
作者 Élcio Nogueira 《Journal of Materials Science and Chemical Engineering》 2022年第2期1-17,共17页
This work aims to establish comparisons between two models used for the performance of heat exchangers. The chosen system, in this case, consists of a heat exchanger used in automotive radiators flat finned tube type.... This work aims to establish comparisons between two models used for the performance of heat exchangers. The chosen system, in this case, consists of a heat exchanger used in automotive radiators flat finned tube type. Water and ethylene glycol compound as base fluid and volume fractions of iron oxide nanoparticles (Fe<sub>3</sub>O<sub>4</sub>) are used as a refrigerant. The quantities determined in this work are the nanofluid exit temperature, the air exit temperature, the absolute error between the models for heat transfer rate, and Effectiveness. The quantities that constitute parameters, independent variables, are the airflow, represented by the Reynolds number, and the iron oxide volume fraction. Ethylene Glycol 50% compound has slightly better thermal performance than pure water and reduces the reactive effect of water on the environment, increasing the average life of the equipment. The absolute relative error between the models is less than 20% and presents maximum values with the increase of the nanoparticle volume fraction and growth in the Reynolds number for the air. 展开更多
关键词 Efficiency and effectiveness Method ε-NTU Method Compact Heat exchanger Iron Oxid Nanoparticles NANOFLUID
下载PDF
Is plasma exchange effective for microscopic polyarteritis?
17
《中国输血杂志》 CAS CSCD 2001年第S1期391-,共1页
关键词 Is plasma exchange effective for microscopic polyarteritis
下载PDF
The effect observation of treating mycetism with plasma exchange
18
《中国输血杂志》 CAS CSCD 2001年第S1期393-,共1页
关键词 The effect observation of treating mycetism with plasma exchange
下载PDF
Analysis of the Moderator Effect of RMB Exchange-- Rate on Export The Case of Guangdong Province in China
19
作者 Yan Zhang Yan Zhou Haojia Chen 《Economics World》 2017年第3期281-286,共6页
An important limitation of the research literatures which study the effect on the export of the real effective exchange rates is the lack of application of interaction or moderator effect among the independent variabl... An important limitation of the research literatures which study the effect on the export of the real effective exchange rates is the lack of application of interaction or moderator effect among the independent variables. To remedy this lacuna, the authors developed a model in which real effective exchange rate moderated the effect of import and utilization of foreign capital on export. The sample comprised 11 years' data in Guangdong China. The result showed that real effective exchange rate of RMB affected the export by interacting with utilization of foreign capital. Moreover, to some degree, the real effective exchange rate can also act as moderator between import and export. 展开更多
关键词 IMPORT EXPORT real effective exchange rate (REER) utilization of foreign capital moderator effect
下载PDF
Grain Size Dependence of Exchange-Coupling Interaction between Magnetically Soft-Hard Grains and Effective Anisotropy
20
作者 韩广兵 高汝伟 +3 位作者 傅爽 刘汉强 冯维存 陈伟 《Journal of Rare Earths》 SCIE EI CAS CSCD 2004年第6期790-793,共4页
Taking α-Fe and Nd_2Fe_(14)B grains as example, the grain size dependence of the exchange-coupling interaction and effective anisotropy and also their variations depending on the ratio of magnetically soft and hard g... Taking α-Fe and Nd_2Fe_(14)B grains as example, the grain size dependence of the exchange-coupling interaction and effective anisotropy and also their variations depending on the ratio of magnetically soft and hard grain sizes, D_s∶D_h, were investigated. When grain size D>L_(ex), the grain’s anisotropy is the statistic value of the coupled and uncoupled part. The anisotropy constant of uncoupled part is the common value K_1 and that of coupled part varies with the distance to the grain surface. The effective anisotropy constant between magnetically soft and hard grains, K_(eff), can be expressed as the sum of the products of volume fractions for soft and hard grains, respectively, and the corresponding mean anisotropy constants. The calculation results indicate that the exchange-coupling interaction is enhanced with the reduction of grain size, and the effective anisotropy decreases with reducing grain size and increasing ratio of D_s∶D_h. In order to get high effective anisotropy constant, K_(eff), in composite magnetically soft-hard grains, the hard grain size should be larger than 30 nm and the soft grain size should be about 10 nm. 展开更多
关键词 metal materials exchange-coupling interaction effective anisotropy magnetic grains rare earths
下载PDF
上一页 1 2 93 下一页 到第
使用帮助 返回顶部