CORROSION OF 1Cr13 STAINLESS STEEL IN SOILS 被引量:5
1
作者 C. Sun, H.X. Li and S.Q. Zhang State Key Laboratory for Corrosion and Protection Institute of Corrosion and Protection of Metals, The Chinese Academy of Sciences, Shenyang 110015, China 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 1999年第5期929-931,共3页
The network of soil corrosion of China, initiated in 1989 a soil burial program in representative corrosive soils utilizing 2 stainless steels(1Cr13 and 1Cr18Ni9Ti), The test soil sites contained acid, neutral, and al... The network of soil corrosion of China, initiated in 1989 a soil burial program in representative corrosive soils utilizing 2 stainless steels(1Cr13 and 1Cr18Ni9Ti), The test soil sites contained acid, neutral, and alkaline soils. This report contains the results of 1Cr13 stainless steel obtained for specimens buried in the soils for up to 1,3,5 years.The results shown, there is slight corrosion of 1Cr13 stainless steel in acid or neutral soils and severe pitting corrosion in alkaline soils. The total contents of Cl and SO 4 2 in soils was the most important factor determining the corrosion behavior of 1Cr13 stainless steel in soils. The weight loss of 1Cr13 increases with the growing of the total contents of Cl and SO 4 2 in soils. 展开更多
关键词 stainless steel soil corrosion
下载PDF
Simulated Corrosion Test of Q235 Steel in Diatomite Soil 被引量:5
2
作者 Jian LI Hang SU +3 位作者 Feng CHAI Xiao-ping CHEN Xiang-yang LI Hui-min MENG 《Journal of Iron and Steel Research(International)》 SCIE EI CAS CSCD 2015年第4期352-360,共9页
Through the study of the corrosion behavior of Q235 steel in actual Yingtan soil and two simulated acidic soils with different water contents, the calculation of corrosion mass losses, and the analysis of the corrosio... Through the study of the corrosion behavior of Q235 steel in actual Yingtan soil and two simulated acidic soils with different water contents, the calculation of corrosion mass losses, and the analysis of the corrosion mor- phologies and products by means of scanning electron microscope (SEM) and X-ray diffraction (XRD), the results demonstrated that the diatomite soil could simulate the corrosion in actual soil veritably. In both actual soil and simu- lated soil with 16.4% water content, the corrosion rates of Q235 steel were approximately 0.1 mm/a, the corrosion morphologies were mainly extension and connection of corrosion spots on sample surface, and the corrosion products were composed of a-FeOOH, γ-FeOOH, Fe3 O4 and Fe2O3. When other media conditions remained unchanged, the corrosion area of Q235 steel was larger in simulated soil with 34.5 % water content, and the corrosion rate reached 0.48 mm/a after 360 h of corrosion, which was nearly 5 times as the value in actual soil. Compared with the corro- sion products in actual soil, the proportion of γ-FeOOH in simulated soil with 34.5 % water content was higher, and the wα-FeOOH/wγ-FeOOH ratio was 1. 4, which was only 1/3 of the value in actual soil. 展开更多
关键词 soil corrosion simulated test DIATOMITE corrosion behavior water content Q235 steel
原文传递
Corrosion behavior of low-carbon Cr micro-alloyed steel for grounding grids in simulated acidic soil 被引量:2
3
作者 Jian Li Hang Su +4 位作者 Feng Chai Dong-mei Xue Li Li Xiang-yang Li Hui-min Meng 《Journal of Iron and Steel Research(International)》 SCIE EI CAS CSCD 2018年第7期755-766,共12页
To improve the corrosion resistance of steels for grounding grids, a low-carbon Cr micro-alloyed steel was developed (C 1 steel), and corrosion behavior of Q235 steel and newly developed C1 steel in simulated acidic... To improve the corrosion resistance of steels for grounding grids, a low-carbon Cr micro-alloyed steel was developed (C 1 steel), and corrosion behavior of Q235 steel and newly developed C1 steel in simulated acidic soil was investigated. The corrosion rate was evaluated with the mass loss measurements, while the corrosion morphology of surface and cross section of rust layer was observed by scanning electron microscopy. The corrosion products were analyzed by energy- dispersive X-ray spectrometry, X-ray diffraction and X-ray photoelectron spectroscopy, and the polarization curve was measured using potentiodynamic polarization method. Results indicated that C 1 steel displayed good corrosion resistance in the simulated acidic soil, of which the corrosion rate was only 30% of that of Q235 steel after corrosion for 360 h. The analysis of rust layer showed that lower carbon content in steel could reduce the tendency of micro cell corrosion and appropriate amount of chromium could improve the corrosion potential of metal matrix. Moreover, the analysis of X-ray photoelectron spectroscopy revealed that the chromium enriched in inner rust layer of C1 steel existed mainly in the form of Fe2CrO4, which facilitated the formation of Cr-goethite and improved the protection of corrosion products. 展开更多
关键词 soil corrosion Grounding grid Low-carbon steel Cr micro-alloying corrosion product - Cr-goethite
原文传递
Galvanic Corrosion Behavior of Copper-Drawn Steel for Grounding Grids in the Acidic Red Soil Simulated Solution 被引量:2
4
作者 Xiao-Lei Fan Yun-Xiang Chen +3 位作者 Jun-Xi Zhang De-Yuan Lin Xuan-Xuan Liu Xiao-Jian Xia 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2020年第11期1571-1582,共12页
The influence of pH and metallographic structure on the corrosion behavior of copper-drawn steel is studied with the simulated system.The effect of pH on the corrosion behavior of copper-drawn steel has been investiga... The influence of pH and metallographic structure on the corrosion behavior of copper-drawn steel is studied with the simulated system.The effect of pH on the corrosion behavior of copper-drawn steel has been investigated using open-circuit potential,potentiodynamic polarization,galvanic current measurement,scanning electron microscopy and scanning vibrating electrode technique techniques.The steel is corroded as anode,while the corrosion of copper plate is protected as cathode.All the results revealed that pH and metallographic structure had a significant influence on the corrosion behavior of copper-drawn steel.With the decrease in pH value from 6 to 2.4,the corrosion rate of copper-drawn steel galvanic couple(Cu-Fe GC)obviously increased in the simulated solution of acidic red soil.The electric field formed by the Cu-Fe GC changes the direction of ion migration between the copper and drawn steel electrodes,which impacts the composition and microstructure of corrosion products formed on the electrode surface. 展开更多
关键词 Cu-Fe galvanic couple Electrochemical test Scanning vibrating electrode technique(SVET)measurement soil corrosion
原文传递
Formation of Black Patina on Bronze Mirrors Caused by Humic Acid
5
作者 MA Zhaozeng JIN Lianji YIN Xiulan (Applied Science School, USTB, Beijing 100083, China) 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 1997年第2期38-42,共5页
The formation of black patina caused by soil humic acid under different conditions has been studied,and the black, grey and brown shiny surfaces prepared in laboratory have been analysed. The formation of tin-rich shi... The formation of black patina caused by soil humic acid under different conditions has been studied,and the black, grey and brown shiny surfaces prepared in laboratory have been analysed. The formation of tin-rich shiny black surface on mirrors was the product of the soil corrosion of the bronze mirrors. It is formed by reaction between the alloy and the humic acid in soil, and leaching of copper and lead oxides through a long period of time when the mirrors were buried under the ground. A dense cormsion-resistallt layer on the bronze mirrors consisted predominantly of stannic oxide. 展开更多
关键词 bronze mirrors black patina humic acid soil corrosion
下载PDF
An Application of Dynamic Structure Model to SoilCorrosion Research
6
作者 ZHAO Bingdong GUAN Hua(Department of Geography,Hen an University, Kaifeng 475001, China) 《Systems Science and Systems Engineering》 CSCD 1999年第1期90-95,共6页
Soil corrosion is a complex system which is difficult to be simulated with mathematicalmodels. Taking the mountainous areas in western henan Province as an example, this paper describesthe application of dynamic struc... Soil corrosion is a complex system which is difficult to be simulated with mathematicalmodels. Taking the mountainous areas in western henan Province as an example, this paper describesthe application of dynamic structure model to soil corrosion analysis. The primary component factors ofthe soil corrosion system and the causality of the factors are determined in this paper. The interactiverelations of the systematic variables is established with delphi method. The dynamic structure modelis selected to make the forecast of the soil corrosion system, the analysis of sensitivity of the variablesand the analysis of the system control. 展开更多
关键词 mountainous areas in western henan province dynamic structure model soil corrosion system forecast
原文传递
Structure and Formative Mechanism of Black Patina on Bronze Mirrors
7
作者 Zhaozeng Ma Ling Du +2 位作者 Xiulan Yin Lianji Jin Chunying Fang(Applied Science School, University of Science and Technology Beijing, Beijing 100083, China) 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 1998年第3期147-155,共9页
The formation of the black patina induced by soil humic asid under different conditions was studied, theblack, grey and brown colored shiny surfaces prepared in laboratory were analyzed. As a result the formation ofti... The formation of the black patina induced by soil humic asid under different conditions was studied, theblack, grey and brown colored shiny surfaces prepared in laboratory were analyzed. As a result the formation oftin-rich shiny black surface on bronze mirrors is the product of soil corrosion of the bronze mirrors. The patina isformed by reection between the alloy and the humic acid in soil, and leaching of copper and lead oxides through along period time when the mirrors were buried under the ground leaving a dense compact corrosion-resistant layerconsisted predominantly of stannic oxide microcrystal. 展开更多
关键词 black patina on ancient bronze mirror humic acid soil corrosion SnO_2 microcrystal
下载PDF
Crevice Corrosion of K60 in Dry Desertification Saline Soil
8
作者 LI Ming SHI Zhi-min LIU Yu-bao 《Journal of Iron and Steel Research(International)》 SCIE EI CAS CSCD 2013年第4期76-80,共5页
Corrosion products of K60crevice samples which were buried in Ordos area were analyzed by scanning electron microscopy and X-ray diffraction.The result showed that,the corrosion potential decreased differently in the ... Corrosion products of K60crevice samples which were buried in Ordos area were analyzed by scanning electron microscopy and X-ray diffraction.The result showed that,the corrosion potential decreased differently in the crevice and a maximum negative existed at the bottom side;with pH value reduced,the dissolved oxygen was nearly exhausted in the crevice.When the opening side of the coupons was coupled with each other,the crevice corrosion in the crevice might be accelerated and the pH value gradually reduced;however,the oxygen was not completely exhausted.The unbalanced current density between anode and cathode was the main cause of blocked self-catalysis effect in the crevice,and was also the main cause of corrosion of alloys.Lumpy corrosion happened on the surface of metal,and rusty layer was composed of Fe3O4,Fe2O3,FeO,FeOOH and FeS which distributed in the opening of crevice.There were the reddish-brown corrosion products and white matter which distributed in the form of filiform and spotted in the center part of crevice.The analysis showed that the white matter might include oxide of Fe and NaHCO3. 展开更多
关键词 K60crevice sample Ordos soil corrosion product
原文传递