Since the calibration accuracy decreases with the reduction of irradiance power,the nonlinearity of sensitivity is experimentally investigated and corrected in order to improve the precision of calibration for Solar I...Since the calibration accuracy decreases with the reduction of irradiance power,the nonlinearity of sensitivity is experimentally investigated and corrected in order to improve the precision of calibration for Solar Irradiance Absolute Radiometer( SIAR). The optimization method is proposed based on the interpolation approximation principle. The real-time correction sensitivities are repeatedly measured at each radiant power.The relative system error of sensitivity nonlinearity is 2.2%. The impact of sensitivity nonlinearity is analyzed.The radiant powers are measured by the optimization method and the traditional method. The comparison experiment results illustrate that the optimization method improves the measure accuracy to 0. 1%. The sensitivity nonlinearity is compensated by the real-time correction. Thus,the optimization method significantly improves the calibration precision of ground-based comparison experiment. The investigation of sensitivity nonlinearity also provides the theoretical and experimental basis for optimizing the on-orbit calibration precision of Total Solar Irradiance Monitor( TSIM).展开更多
We experimentally evaluate and correct the non-equivalence between electrical and radiative heating of solar irradiance absolute radiometer to compensate the systematic error of radiant power measurement at ambient pr...We experimentally evaluate and correct the non-equivalence between electrical and radiative heating of solar irradiance absolute radiometer to compensate the systematic error of radiant power measurement at ambient pressure. A relative difference of the order of 0.08%-0.27% between electrical and radiative heating sensitivities is shown, and the resulting non-equivalence correction factor is calculated. The radiant power measurement equation is modified using the non-equivalence correction factor, a systematic deviation of 0.19% of radiant power measurement is hence eliminated.展开更多
基金Sponsored by the National Natural Science Foundation of China(Grant Nos.41227003 and 41474161)
文摘Since the calibration accuracy decreases with the reduction of irradiance power,the nonlinearity of sensitivity is experimentally investigated and corrected in order to improve the precision of calibration for Solar Irradiance Absolute Radiometer( SIAR). The optimization method is proposed based on the interpolation approximation principle. The real-time correction sensitivities are repeatedly measured at each radiant power.The relative system error of sensitivity nonlinearity is 2.2%. The impact of sensitivity nonlinearity is analyzed.The radiant powers are measured by the optimization method and the traditional method. The comparison experiment results illustrate that the optimization method improves the measure accuracy to 0. 1%. The sensitivity nonlinearity is compensated by the real-time correction. Thus,the optimization method significantly improves the calibration precision of ground-based comparison experiment. The investigation of sensitivity nonlinearity also provides the theoretical and experimental basis for optimizing the on-orbit calibration precision of Total Solar Irradiance Monitor( TSIM).
基金supported by the National Natural Science Foundation of China under Grant No.41227003
文摘We experimentally evaluate and correct the non-equivalence between electrical and radiative heating of solar irradiance absolute radiometer to compensate the systematic error of radiant power measurement at ambient pressure. A relative difference of the order of 0.08%-0.27% between electrical and radiative heating sensitivities is shown, and the resulting non-equivalence correction factor is calculated. The radiant power measurement equation is modified using the non-equivalence correction factor, a systematic deviation of 0.19% of radiant power measurement is hence eliminated.