Determination of organochlorine pesticides from juice samples using magnetic biochar-based dispersive micro-solid phase extraction in combination with dispersive liquid-liquid microextraction
1
作者 Kero Assefa Ago Shimeles Addisu Kitte Abera Gure 《Emerging Contaminants》 CSCD 2024年第1期126-138,共13页
Analysis of pesticide residue levels in juice beverages is important to ensure safe consumption and avoid global trade concerns associated to pesticide contaminations.A simple,inexpensive and effective method was deve... Analysis of pesticide residue levels in juice beverages is important to ensure safe consumption and avoid global trade concerns associated to pesticide contaminations.A simple,inexpensive and effective method was developed for the determination of organochlorine pesticides(OCPs)in bottled juice drinks using GC-MS.Sample pretreatment was performed using dispersive solid-phase microextraction(D-μ-SPE)for matrix desorption and dispersive liquid-liquid microextraction(DLLME)for analyte enrichment.In this study,an affordable and effective sorbent for the adsorption of OCPs from juice samples was synthesized from avocado seeds mixed with magnetic precursors for D-μSPE.The ground avocado seeds combined with a magnetic precursor nanocomposite were characterized using various instruments including scanning electron microscopy(SEM),X-ray diffraction(XRD),Fourier transform infrared spectroscopy(FTIR),and Brunauer-Emmett-Teller(BET)analysis.The solution obtained from D-μ-SPE desorption was used as a dispersant for the subsequent DLLME,which made the combination of D-μ-SPE with DLLME much easier.The effectiveness of the method was enhanced by optimizing the influential parameters in both D-μ-SPE and DLLME.Then after,the optimal values were determined for the real sample analysis.Accordingly,there was good linear dynamic range with a coefficient of determination(r2)≥0.9989.The limit of detection and quantification were 0.02–0.69 and 0.06–2.10 ng/L respectively.The method showed high enrichment factors ranging from 96 to 313 with recoveries of 87–100%.Intraday and interday precisions were≤4%.Compared with other reported methods,this method is a one-step,simple,cheap,fast,and environmentally friendly alternative and straightforward method for adsorbing organochlorine pesticides from sample solutions.These results demonstrates the high potential of the proposed method for the extraction and cleanup of contaminants in selected juices and other related samples. 展开更多
关键词 Dispersive micro solid phase extraction Dispersive liquid-liquid microextraction Juice samples Magnetic biochar Organochlorine pesticides Gas chromatography-mass spectrometry
原文传递
Determination of particulate polycyclic aromatic hydrocarbons in ambient air by gas chromatography-mass spectrometry after molecularly imprinted polymer extraction 被引量:1
2
作者 Maria Chiara Pietrogrande Giorgia Demaria Mara Russo 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2023年第2期644-654,共11页
A solid phase extraction procedure(SPE)is described for the quantitative analysis of polycyclic aromatic hydrocarbons(PAHs)in atmospheric particulate matter(PM),as ubiquitous environmental pollutants routinely measure... A solid phase extraction procedure(SPE)is described for the quantitative analysis of polycyclic aromatic hydrocarbons(PAHs)in atmospheric particulate matter(PM),as ubiquitous environmental pollutants routinely measured in air qualitymonitoring.A SPE cartridge was used based on a molecular imprinted polymer(MIP-SPE)properly tailored for selective retention of PAHs with 4 and more benzene fused rings.The performance of the clean-up procedure was evaluated with the specific concern of selective purification towards saturated hydrocarbons,which are the PM components mostly interfering GC analysis of target PAHs.Under optimized operative conditions,the MIP-SPE provided analyte recovery close to 95%for heavier PAHs,from benzo(α)pyrene to benzo(ghi)perylene,and close to 90%for four benzene rings PAHs,with good reproducibility(RSDs:2.5%-5.9%).Otherwise,C_(17)-C_(32) n-alkanes were nearly completely removed.The proposed method was critically compared with Solid Phase Micro Extraction(SPME)using a polyacrylate fiber.Both methods were successfully applied to the analysis of ambient PM2.5 samples collected at an urban polluted site.Between the two procedures,the MIP-SPE provided the highest recovery(R%≥93%)for PAHs with 5 and more benzene rings,but lower for lighter PAHs.In contrast,SPME showed a mean acceptable R%value(∼80%)for all the investigated PAHs,except for the heaviest PAHs in the most polluted samples(R%:110%-138%),suggesting an incomplete purification from the interfering n-hydrocarbons. 展开更多
关键词 Polycyclic aromatic hydrocarbons Atmospheric particle matter Molecularly imprinted polymers-solid-phase extraction solid phase micro extraction GC/MS analysis
原文传递
Modified Coated Copper Wire as a New Fiber for SPME-GC Analysis of Some Polycyclic Aromatic Hydrocarbons
3
作者 Akram Masoumi Maryam Abbasian +1 位作者 M. Moharamzadeh Hossein Salar Amoli 《Materials Sciences and Applications》 2016年第6期316-325,共10页
In this study for the first time, a novel copper Solid Phase Microextraction (SPME) fiber has been introduced for removal of naphthalene, phenanthrene and anthracene from aqueous solution. Copper was used as a solid s... In this study for the first time, a novel copper Solid Phase Microextraction (SPME) fiber has been introduced for removal of naphthalene, phenanthrene and anthracene from aqueous solution. Copper was used as a solid support, which was at first coated by 3-mercaptopropyltrimethoxysi- lane. A stationary phase of oxidized multi walled carbon nanotube (MWCNTs)) was bonded to the surface of the copper wire. The developed SPME was characterized by IR and Scanning Electron Microscopy (SEM) and coupled to gas chromatography for separation of the analytes. Stability of the fiber, the effect of coating thickness and recovery time were optimized. The MWCNTs film thickness was about 5 μm which was perfect for a rapid mass transfer. The detection limits were at the range of 0.005 to 0.1 μg&middot;L<sup>-1</sup>. The calibration curves were linear R<sup>2</sup> > 0.9813 in the range of 0.01 to 5 μg&middot;L<sup>-1</sup>. The method has been successfully applied for real samples with standard addition of 5 μL<sup>-1</sup> of each sample. Stability study of the fiber to acid and alkali shows that it can be used for more than 50 times. 展开更多
关键词 Gas Chromatography solid phase micro extraction Coated Copper Wire Polycyclic Aromatic Hydrocarbons Carbon Nanotube