期刊文献+
共找到2,804篇文章
< 1 2 141 >
每页显示 20 50 100
Effect of two-step solid solution on microstructure andδphase precipitation of Inconel 718 alloy
1
作者 Enyu Liu Qingshuang Ma +5 位作者 Xintong Li Aoxue Gao Jing Bai Liming Yu Qiuzhi Gao Huijun Li 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2024年第10期2199-2207,共9页
Inconel 718 is the most popular nickel-based superalloy and is extensively used in aerospace,automotive,and energy indus-tries owing to its extraordinary thermomechanical properties.The effects of different two-step s... Inconel 718 is the most popular nickel-based superalloy and is extensively used in aerospace,automotive,and energy indus-tries owing to its extraordinary thermomechanical properties.The effects of different two-step solid solution treatments on microstructure andδphase precipitation of Inconel 718 alloy were studied,and the transformation mechanism fromγ″metastable phase toδphase was clarified.The precipitates were statistically analyzed by X-ray diffractometry.The results show that theδphase content firstly increased,and then decreased with the temperature of the second-step solid solution.The changes in microstructure andδphase were studied by scanning electron microscopy and transmission electron microscopy.An intragranularδphase formed in Inconel 718 alloy at the second-[100]_(δ)[011]γ step solid solution temperature of 925℃,and its orientation relationship withγmatrix was determined as//and(010)_(δ)//(111)γ.Furthermore,the Vickers hardness of different heat treatment samples was measured,and the sample treated by second-step solid solution at 1010℃ reached the maximum hardness of HV 446.84. 展开更多
关键词 Inconel 718 alloy two-step solid solution treatment δphase γ″-δtransformation
下载PDF
Determination of urinary 8-hydroxy-2′-deoxyguanosine by capillary electrophoresis with molecularly imprinted monolith in-tube solid phase microextraction 被引量:6
2
作者 Zhang, Shao Wen Zou, Cun Jie +4 位作者 Luo, Nan Weng, Qian Feng Cai, Ling Shuang Wu, Cai Ying Xing, Jun 《Chinese Chemical Letters》 SCIE CAS CSCD 2010年第1期85-88,共4页
Urinary 8-hydroxy-2 -deoxyguanosine(8-OHdG) is an excellent marker of oxidative DNA damage.In this study,employing guanosine as dummy template a novel molecularly imprinted(MIP) monolithic capillary column had been sy... Urinary 8-hydroxy-2 -deoxyguanosine(8-OHdG) is an excellent marker of oxidative DNA damage.In this study,employing guanosine as dummy template a novel molecularly imprinted(MIP) monolithic capillary column had been synthesized,and that was used as medium of in-tube solid phase microextraction(SPME).Coupled with capillary electrophoresis-electrochemical detection(CE-ECD),the system of extraction and detection of 8-OHdG in urinary sample had been developed.Because of its greater phase ratio combined with conv... 展开更多
关键词 Molecularly imprinted monolith In-tube solid phase microextraction 8-Hydroxy-2 -deoxyguanosine(8-OHdG) Electrophoresis Urine
下载PDF
Analysis of α, β, γ-hexachlorocyclohexanes in water by novel activated carbon fiber-solid phase microextraction coupled with gas chromatography—mass spectrometry 被引量:4
3
作者 SUNTong-hua FANGNeng-hu +2 位作者 ZHUNan-wen WANGYa-lin JIAJin-ping 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2004年第6期945-949,共5页
A fast and simple method for determination of α, β, γ-hexachlorocyclohexanes (HCHs) in water using activated carbon fiber-solid phase microextraction(ACF-SPME) were studied. Results showed the performance of adsorp... A fast and simple method for determination of α, β, γ-hexachlorocyclohexanes (HCHs) in water using activated carbon fiber-solid phase microextraction(ACF-SPME) were studied. Results showed the performance of adsorption and desorption of three HCHs on ACF were excellent. A wide linear range from 10 to 100 μg/L and detection limits of the ng/L level were obtained using ACF-SPME with GC-MS in selected ion monitoring(SIM) acquisition mode. The proposed method was also successfully applied for determination of three HCHs in tap water. Compared to commercial fibers, ACF showed some advantages such as better resistance to solvents, higher thermal stability, longer lifetime and lower cost. The data demonstrated that GC-MS with ACF-SPME is well suitable for the analysis of HCHs in water. 展开更多
关键词 solid phase microextraction activated carbon fiber residue analysis α β γ-hexachlorocyclohexanes GC-MS
下载PDF
Determination of Aromatic Components of Rosa davurica Pall. by Headspace Solid Phase Microextraction Combined with GC-MS 被引量:5
4
作者 Yuan NIU Qiong XU +4 位作者 Jian ZHUANG Yude WANG Lilan DAI Dengfei LI Yalan ZHAO 《Medicinal Plant》 CAS 2018年第5期20-22,26,共4页
[Objectives] To determine the aromatic components of Rosa davurica Pall. [Methods] 42 kinds of aromatic components were identified from the flowers of R. davurica by headspace solid phase microextraction( HS-SPME) com... [Objectives] To determine the aromatic components of Rosa davurica Pall. [Methods] 42 kinds of aromatic components were identified from the flowers of R. davurica by headspace solid phase microextraction( HS-SPME) combined with gas chromatography-mass spectrometry( GC-MS). The main compounds were alcohols( 54. 88%) and aldehydes( 19. 55%). [Results] The top five components with the highest relative content were phenylethyl alcohol( 12. 69%),geraniol( 9. 85%),citronellol( 8. 80%),nerol( 7. 84%) and 2-n-pentylfuran( 7. 45%). [Conclusions] Headspace solid phase microextraction( HS-SPME) combined with gas chromatography-mass spectrometry( GC-MS) can provide basis for further development and utilization of R. davurica. 展开更多
关键词 Rosa davurica Pall. HEADSPACE solid phase microextraction (HS-SPME) Gas chromatography-mass spectrometry (GC-MS) AROMATIC COMPONENTS
下载PDF
Solid phase microextraction chemical biopsy tool for monitoring of doxorubicin residue during in vivo lung chemo-perfusion 被引量:6
5
作者 Barbara Bojko Nikita Looby +11 位作者 Mariola Olkowicz Anna Roszkowska Bogumiła Kupcewicz Pedro Reck dos Santos Khaled Ramadan Shaf Keshavjee Thomas K.Waddell German Goomez-Rios Marcos Tascon Krzysztof Gorynski Marcelo Cypel Janusz Pawliszyn 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2021年第1期37-47,共11页
Development of a novel in vivo lung perfusion(IVLP)procedure allows localized delivery of high-dose doxorubicin(DOX)for targeting residual micrometastatic disease in the lungs.However,DOX delivery via IVLP requires ca... Development of a novel in vivo lung perfusion(IVLP)procedure allows localized delivery of high-dose doxorubicin(DOX)for targeting residual micrometastatic disease in the lungs.However,DOX delivery via IVLP requires careful monitoring of drug level to ensure tissue concentrations of this agent remain in the therapeutic window.A small dimension nitinol wire coated with a sorbent of biocompatible morphology(Bio-SPME)has been clinically evaluated for in vivo lung tissue extraction and determination of DOX and its key metabolites.The in vivo Bio-SPME-IVLP experiments were performed on pig model over various(150 and 225 mg/m^(2))drug doses,and during human clinical trial.Two patients with metastatic osteosarcoma were treated with a single 5 and 7 μg/mL(respectively)dose of DOX during a 3-h IVLP.In both pig and human cases,DOX tissue levels presented similar trends during IVLP.Human lung tissue concentrations of drug ranged between 15 and 293 μg/g over the course of the IVLP procedure.In addition to DOX levels,Bio-SPME followed by liquid chromatography-mass spectrometry analysis generated 64 metabolic features during endogenous metabolite screening,providing information about lung status during drug administration.Real-time monitoring of DOX levels in the lungs can be performed effectively throughout the IVLP procedure by in vivo Bio-SPME chemical biopsy approach.Bio-SPME also extracted various endogenous molecules,thus providing a real-time snapshot of the physiology of the cells,which might assist in the tailoring of personalized treatment strategy. 展开更多
关键词 In vivo solid phase microextraction Metabolite profiling Spatial resolution Therapeutic drug monitoring Tissue analysis
下载PDF
Comparison of Headspace Solid-Phase Microextraction with Simultaneous Steam Distillation Extraction for the Analysis of the Volatile Constituents in Chinese Apricot 被引量:20
6
作者 CHEN Mei-xia CHEN Xue-sen +4 位作者 WANG Xin-guo CI Zhi-juan LIU Xiao-li HE Tian-ming ZHANG Li-jie 《Agricultural Sciences in China》 CAS CSCD 2006年第11期879-884,共6页
Volatile constituents in fully mature fruits of apricot (Prunus armeniaca L.) cultivar Xinshiji were extracted using headspace solid-phase microextraction (HS-SPME) and simultaneous steam distillation extraction ... Volatile constituents in fully mature fruits of apricot (Prunus armeniaca L.) cultivar Xinshiji were extracted using headspace solid-phase microextraction (HS-SPME) and simultaneous steam distillation extraction (SSDE) and then analyzed using capillary gas chromatography and gas chromatography-mass spectrometry. A total of 70 components were identified by HSSPME, including 20 esters, 19 hydrocarbons, 5 alcohols, 5 ketones, 4 acids, 4 lactones, 3 aldehydes, and 10 miscellaneous components, with the esters being the dominant constituent. On the basis of the odor unit values, it is believed that the following compounds probably contributed to the fresh apricot odor: hexyl acetate, β-ionone, butyl acetate, (E)-2-hexenal, linalool, limonene, γ-decalactone, and hexanal. A total of 49 components were also detected by SSDE, including 13 hydrocarbons, 9 alcohols, 7 aldehydes, 9 esters, 4 ketones, 4 lactones, 2 acids, and 1 miscellaneous component, of which the monoterpene alcohols were the dominant constituents. It could be judged from the odor unit values that the following compounds were the major contributors to boiled apricot aroma: β-ionone, linalool, hexyl acetate, γ-dodecalactone, γ- decalactone, (E)-2-hexenal, hexanal, γ-octalactone, phenylacetaldehyde, butyl acetate, limonene, α-terpineol, and δ-decalactone. The results show that HS-SPME is a simple, rapid, and solvent-free method, which is an alternative to the classical SSDE. 展开更多
关键词 AROMA volatile constituents APRICOT solid-phase microextraction simultaneous distillation-extraction
下载PDF
A novel fiber coating for solid phase microextraction and its application for the extraction of n-alkane from aqueous sample 被引量:1
7
作者 HUANG Min-jia JIANG Gui-bin ZHAO Zong-shan 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2005年第6期930-932,共3页
Base on the previous work in laboratory, a novel polyaniline doped with polydimethylsiloxane coating was developed on a stainless steel wire for solid phase microextraction(SPME) by electroplating method. This elect... Base on the previous work in laboratory, a novel polyaniline doped with polydimethylsiloxane coating was developed on a stainless steel wire for solid phase microextraction(SPME) by electroplating method. This electroplating method not only has advantages of ease preparation and simple equipments required, but also increases the lifetime of the SPME fiber. The composite fiber(polyaniline/ polydimethylsiloxane(PANI/PDMS)) was evaluated by analyzing n-tridecane, n-tetradecane and n-pentadecane in aqueous sample. The new fiber coating showed comprehensive abilities to extract alkanes compounds. The relative standard deviations were found to be 6.8%-10.33%. 展开更多
关键词 solid phase microextraction stainless steel wires electroplating fiber preparation polyaniline/polydimethylsiloxane ALKANES
下载PDF
Preparation of polypyrrole/nanosilica composite for solid-phase microextraction of bisphenol and phthalates migrated from containers to eye drops and injection solutions 被引量:2
8
作者 Mehdi Ansari Dogaheh Mansoureh Behzadi 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2019年第3期185-192,共8页
This paper describes the electrodeposition of polyphosphate-doped polypyrrole/nanosilica nano-composite coating on steel wire for direct solid-phase microextraction of bisphenol A and five phthalates. We optimized inf... This paper describes the electrodeposition of polyphosphate-doped polypyrrole/nanosilica nano-composite coating on steel wire for direct solid-phase microextraction of bisphenol A and five phthalates. We optimized influencing parameters on the extraction efficiency and morphology of the nanocomposite such as deposition potential, concentration of pyrrole and polyphosphate, deposition time and the nanosilica amount. Under the optimized conditions, characterization of the nanocomposite was inves-tigated by scanning electron microscopy and Fourier transform infra-red spectroscopy. Also, the factors related to the solid-phase microextraction method including desorption temperature and time, extrac-tion temperature and time, ionic strength and pH were studied in detail. Subsequently, the proposed method was validated by gas chromatography-mass spectrometry by thermal desorption and acceptable figures of merit were obtained. The linearity of the calibration curves was between 0.01 and 50 ng/mL with acceptable correlation coefficients (0.9956-0.9987) and limits of detection were in the range 0.002-0.01 ng/mL. Relative standard deviations in terms of intra-day and inter-day by five replicate analyses from aqueous solutions containing 0.1 ng/mL of target analytes were in the range 3.3%-5.4% and 5%-7.1%, respectively. Fiber-to-fiber reproducibilities were measured for three different fibers prepared in the same conditions and the results were between 7.3% and 9.8%. Also, extraction recoveries at two different concentrations were ≥96%. Finally, the suitability of the proposed method was demonstrated through its application to the analysis of some eye drops and injection solutions. 展开更多
关键词 solid-phase microextraction Gas chromatography-mass spectrometry Polyphosphate-doped POLYPYRROLE NANOSILICA PHTHALATES BisphenolA
下载PDF
Integration of GC-MS Based Non-Targeted Metabolic Profiling with Headspace Solid Phase Microextraction Enhances the Understanding of Volatile Differentiation in Tobacco Leaves from North Carolina, India and Brazil 被引量:3
9
作者 Dong-Ming Ma Saiprasad V. S. Gandra +1 位作者 Navin Sharma De-Yu Xie 《American Journal of Plant Sciences》 2012年第12期1759-1769,共11页
In this report, gas chromatography-mass spectrometry (GC-MS) based non-targeted metabolomics is used to develop appropriate headspace solid phase microextractions (HS-SPME) to enhance the understanding of volatile com... In this report, gas chromatography-mass spectrometry (GC-MS) based non-targeted metabolomics is used to develop appropriate headspace solid phase microextractions (HS-SPME) to enhance the understanding of volatile complexity of flue-cured tobacco leaves. Non-targeted metabolic profiling of GC-MS shows that the extraction condition of HS-SPME at 100?C for 30 min provides a better metabolite profile than other extraction conditions tested. GC-MS and principal component analyses (PCA) show that among five types of fibers tested, 100 μm polydimethylsiloxane (PMDS), 65 μm polydimethylsiloxane/divinylbenzene (PMDS/DVB) and 75 μm carboxen/polydimethylsiloxane (CAR/ PMS) provide a better reproducible metabolite profile. Based on an appropriate PDMS extraction condition optimized, we use GC-MS analysis and PCA to compare metabolite profiles in flue-cured leaves of tobacco plants grown in North Carolina, India and Brazil, respectively. The resulting data of PCA show that the global metabolic profiles in North Carolina samples are separated from those in Brazil and India samples, two groups of which are characterized by a partially overlapped pattern. Several peaks that were differentially accumulated in samples were annotated to known metabolites by deconvolution analysis, such as norsolanadione, solavetivone and rishtin. Norsolanadione is detected only in Brazil samples. Solavetivone is detected in samples of India and Brazil but not in those of North Carolina. Rishtin is detected in samples of North Carolina and India but not in Brazil samples. These data indicate that not only can a non-targeted metabolic profiling approach enhance the understanding of volatile complexity, but also can identify marker volatile metabolites in tobacco leaves produced in different growth regions. 展开更多
关键词 TOBACCO HEADSPACE solid-phase microextraction Gas Chromatography Mass Spectrum VOLATILE Compounds
下载PDF
Flash Evaporation and Headspace Solid-phase Microextraction for the Analysis of the Essential Oils in Traditional Chinese Medicine,Houttuynia Cordata Thunb 被引量:1
10
作者 MinMinLIANG MeiLingQI RuoNongFU 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第5期659-662,共4页
We have investigated the use of flash evaporation, headspace solid-phase microextraction (HS-SPME) and steam distillation (SD) as sample concentration and preparation techniques for the analysis of volatile constituen... We have investigated the use of flash evaporation, headspace solid-phase microextraction (HS-SPME) and steam distillation (SD) as sample concentration and preparation techniques for the analysis of volatile constituents present in Houttuynia cordata Thunb. The samples were analyzed by gas chromatography (GC) and identified by mass spectrometry (MS). Comparison studies were performed. It was found that the results obtained between Headspace solid-phase microextraction HS-SPME and SD techniques were in good agreement. Seventy-nine compounds in Houttuynia cordata Thunb were identified by MS. In flash evaporation, thirty-nine compounds were identified. Discrimination in the response for many constituents studied was not observed, which can be clearly observed in SD and HS-SPME techniques. As a conclusion, HS-SPME is a powerful tool for determining the volatile constitutes present in the Houttuynia cordata. 展开更多
关键词 Headspace solid-phase microextraction flash evaporation essential oils GC-MS.
下载PDF
Application of Phenyl Bonded Mesoporous Silica as A Novel Coating Layer of Solid-phase Microextraction for Determination of Benzo[a]pyrene in Water Samples
11
作者 XinZhenDU YaRongWANG QianMA XueFengMAO JinGuoHOU 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第6期801-804,共4页
Phenyl bonded mesoporous silica (C6H5-MCM-41) was applied as the fiber coating of solid-phase microextraction (SPME). The performance of the fiber coating was discussed coupling to HPLC. Applicability of mesoporous fi... Phenyl bonded mesoporous silica (C6H5-MCM-41) was applied as the fiber coating of solid-phase microextraction (SPME). The performance of the fiber coating was discussed coupling to HPLC. Applicability of mesoporous fiber coating was examined for the determination of benzo[a]pyrene (B[a]P) in water samples. The limit of detection (LOD) is 0.28μg·L-1. Good recovery and relative standard deviation (RSD) were obtained. 展开更多
关键词 Mesoporous silica solid-phase microextraction HPLC benzo[a]pyrene.
下载PDF
Sol-Gel-Coated Calix[4]arene Fiber for Solid-Phase Microextraction
12
作者 LiXiu-juan XiaoRui-min +1 位作者 LiHai-bing ZengZhao-rui 《Wuhan University Journal of Natural Sciences》 CAS 2003年第04A期1153-1155,共3页
5, 11, 17, 23-tetra-tert-butyl-25, 27-diethoxy-26, 28-dihydroxycalix \ arene /hydroxy-terminated silicone oil coated fiber was first prepared and applied for solid-phase microextraction with sol-gel technology. The pr... 5, 11, 17, 23-tetra-tert-butyl-25, 27-diethoxy-26, 28-dihydroxycalix \ arene /hydroxy-terminated silicone oil coated fiber was first prepared and applied for solid-phase microextraction with sol-gel technology. The properties of the new coating were investigated by analysis of benzene derivatives, polycyclic aromatic hydrocarbons and aromatic amines. The fiber is characterized by good sensitivity and selectivity to these aromatics. The fiber has stable performance at a high temperature of 380℃ and after a long solvent immersing, thus its lifetime is very long. It shows good fiber-to-fiber and batch-to-batch reproducibility. Furthermore, broad linear ranges and low detection limits are also its characteristics. 展开更多
关键词 solid-phase microextraction SOL-GEL CALIXARENE aromatic compounds
下载PDF
Solid-phase Microextraction with Benzoxy-calix[6]arene Fiber Coupled to Gas Chromatography for the Analysis of Polycyclic Aromatic Hydrocarbons in Water
13
作者 YE Chang-wen ZHANG Xue-na HUANG Jiang-yan LI Xiu-juan PAN Si-yi 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第2期198-202,共5页
Headspace solid-phase microextraction(HS-SPME) with sol-gel calix[6]arene-containing fiber followed by gas chromatography with a flame ionization detector was used to examine the composition and distribution of seve... Headspace solid-phase microextraction(HS-SPME) with sol-gel calix[6]arene-containing fiber followed by gas chromatography with a flame ionization detector was used to examine the composition and distribution of seven polycyclic aromatic hydrocarbons(PAHs) in water. The novel SPME fiber exhibited higher extraction efficiency to PAHs compared with poly(dimethylsiloxane) and other calixarene-containing fibers. Extraction/retention mechanism based on the interactions between calixarenes and PAHs was discussed. Owing to the good selectivity and high extraction capability of this calixarene fiber, low detection limits were obtained in a range of 0.34―6.50 ng/L and the relative standard deviation values were ≤12.3% for all of the analytes. The linear ranges of the proposed method were five orders of magnitude for the tested compounds, with linear correlation coefficients(r) greater than 0.998. The method was applied to the determination of polycyclic aromatic hydrocarbons in nine water sources in Wuhan City, China. Standard addition method was selected for the quantification and the recovery values were in a satisfactory range. Total PAHs concentrations in the nine surface water samples were found to vary between undetectable and 8.840 μg/L with two- and three-ring PAHs predominating. 展开更多
关键词 Polycyclic aromatic hydrocarbon solid-phase microextraction CALIXARENE Gas chromatography WATER
下载PDF
Preparation of A New Fiber by Sol-gel Technology in Solid-phase Microextraction (SPME)
14
作者 LiMingWEI QingYuOU JuBaiLI 《Chinese Chemical Letters》 SCIE CAS CSCD 2004年第9期1127-1130,共4页
The sol-gel technology is applied for the preparation of solid-phase microextraction (SPME) fiber. The fiber demonstrates high thermal stability, efficient extraction rate and the selectivity for non-polar or low-pol... The sol-gel technology is applied for the preparation of solid-phase microextraction (SPME) fiber. The fiber demonstrates high thermal stability, efficient extraction rate and the selectivity for non-polar or low-polar analytes. Efficient SPME-GC-FID analyses of benzene- toluene-ethylbenzene-xylenes (BTEXs) and low-polar halocarbon were achieved by the sol-gel coated DSDA-DDBT-TiO2 fiber. Some parameters of the SPME fiber for the determination of halocarbon in aqueous sample were investigated. 展开更多
关键词 solid-phase microextraction sol-gel technology SELECTIVITY polyimide (DSDA-DDBT).
下载PDF
Solid phase microextraction(SPME) sampling under turbulent conditions and for the simultaneous collecting of tracer gases 被引量:1
15
作者 Underwood Susanne W. Jong Edmund C. +3 位作者 Luxbacher Kray D. Sarver Emily A. Ripepi Nino S. Mc Nair Harold M. 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2015年第4期559-563,共5页
Solid phase microextraction (SPME) is a solvent-flee method of sample collection. SPME is an appealing method for sample collection because it is designed for the sampling of trace level analytes with short sampling... Solid phase microextraction (SPME) is a solvent-flee method of sample collection. SPME is an appealing method for sample collection because it is designed for the sampling of trace level analytes with short sampling times in a variety of environments. Additionally, SPME can be used to directly deliver a sample to a gas chromatograph (GC) for analysis by means of thermal desorption. In this paper, the performance of SPME under dynamic conditions was investigated. Additionally, the competence of SPME sampling for the simultaneous analysis of multiple trace analytes was also evaluated. This work is discussed in the context of underground mine ventilation surveys but is applicable to any industry in which ventilation circuits must be evaluated. The results of this paper showed that the performance of the 100 ~m PDMS SPME fiber was both precise and rapid under dynamic conditions. This SPME fiber was also able to simultaneously collect sulfur hexafluoride (SF6) and perfluoromethylcyclohexane (PMCH) with adequate sensitivity. 展开更多
关键词 solid phase microextraction Sulfur hexafluoride Perfluoromethylcyclohexane Tracer gas Mine ventilation Air sampling
下载PDF
Determination of organochlorine pesticides from juice samples using magnetic biochar-based dispersive micro-solid phase extraction in combination with dispersive liquid-liquid microextraction
16
作者 Kero Assefa Ago Shimeles Addisu Kitte Abera Gure 《Emerging Contaminants》 CSCD 2024年第1期126-138,共13页
Analysis of pesticide residue levels in juice beverages is important to ensure safe consumption and avoid global trade concerns associated to pesticide contaminations.A simple,inexpensive and effective method was deve... Analysis of pesticide residue levels in juice beverages is important to ensure safe consumption and avoid global trade concerns associated to pesticide contaminations.A simple,inexpensive and effective method was developed for the determination of organochlorine pesticides(OCPs)in bottled juice drinks using GC-MS.Sample pretreatment was performed using dispersive solid-phase microextraction(D-μ-SPE)for matrix desorption and dispersive liquid-liquid microextraction(DLLME)for analyte enrichment.In this study,an affordable and effective sorbent for the adsorption of OCPs from juice samples was synthesized from avocado seeds mixed with magnetic precursors for D-μSPE.The ground avocado seeds combined with a magnetic precursor nanocomposite were characterized using various instruments including scanning electron microscopy(SEM),X-ray diffraction(XRD),Fourier transform infrared spectroscopy(FTIR),and Brunauer-Emmett-Teller(BET)analysis.The solution obtained from D-μ-SPE desorption was used as a dispersant for the subsequent DLLME,which made the combination of D-μ-SPE with DLLME much easier.The effectiveness of the method was enhanced by optimizing the influential parameters in both D-μ-SPE and DLLME.Then after,the optimal values were determined for the real sample analysis.Accordingly,there was good linear dynamic range with a coefficient of determination(r2)≥0.9989.The limit of detection and quantification were 0.02–0.69 and 0.06–2.10 ng/L respectively.The method showed high enrichment factors ranging from 96 to 313 with recoveries of 87–100%.Intraday and interday precisions were≤4%.Compared with other reported methods,this method is a one-step,simple,cheap,fast,and environmentally friendly alternative and straightforward method for adsorbing organochlorine pesticides from sample solutions.These results demonstrates the high potential of the proposed method for the extraction and cleanup of contaminants in selected juices and other related samples. 展开更多
关键词 Dispersive micro solid phase extraction Dispersive liquid-liquid microextraction Juice samples Magnetic biochar Organochlorine pesticides Gas chromatography-mass spectrometry
原文传递
基于HS-GC-IMS和HS-SPME-GC-MS的蛋白酶对豆粕挥发性风味的影响分析 被引量:1
17
作者 齐宝坤 刘雨雯 +3 位作者 姚玉雪 吴思雨 孙树坤 陈昊 《农业机械学报》 EI CAS CSCD 北大核心 2024年第4期352-367,410,共17页
为研究不同蛋白酶酶解对豆粕挥发性风味成分的影响,选用4种蛋白酶(碱性蛋白酶、中性蛋白酶、木瓜蛋白酶、风味蛋白酶)对豆粕进行酶解,采用顶空-气相色谱-离子迁移谱(Headspace-gas chromatography-ion mobility spectroscopy,HS-GC-IMS... 为研究不同蛋白酶酶解对豆粕挥发性风味成分的影响,选用4种蛋白酶(碱性蛋白酶、中性蛋白酶、木瓜蛋白酶、风味蛋白酶)对豆粕进行酶解,采用顶空-气相色谱-离子迁移谱(Headspace-gas chromatography-ion mobility spectroscopy,HS-GC-IMS)和顶空固相微萃取-气相色谱-质谱(Headspace solid phase microextraction-gas chromatography-mass spectrometry,HS-SPME-GC-MS)联用技术分析不同豆粕酶解物(Soybean meal hydrolysates,SMH)的挥发性风味成分,并结合主成分分析(Principal component analysis,PCA)、热图聚类和正交偏最小二乘判别法(Orthogonal partial least squares-discriminant analysis,OPLS-DA)对不同SMH进行分析。结果表明:碱性蛋白酶、中性蛋白酶、木瓜蛋白酶和风味蛋白酶酶解豆粕的挥发性风味成分存在较大差异。HS-GC-IMS鉴定出84种挥发性成分,筛选得到33种差异风味物质,发现酶解后酮类物质显著降低而醛类、醇类和酯类物质含量明显增加。PCA结果表明不同SMH之间的风味存在显著差异。最终通过OPLS-DA筛选出贡献较大的挥发性化合物,同时构建出可靠的用以鉴别SMH的模型。HS-SPME-GC-MS检测出103种差异风味物质,可用于区分不同SMH,被检出的挥发性组分中醛类、醇类和酮类等化合物为SMH风味的形成做出主要贡献,明晰了部分风味化合物形成的原因。PCA和聚类热图结果表明不同蛋白酶酶解对豆粕的挥发性风味物质的种类和含量有显著影响,其中,风味蛋白酶和木瓜蛋白酶对豆粕的风味改善最为显著。 展开更多
关键词 豆粕 酶解 顶空-气相色谱-离子迁移谱 顶空固相微萃取-气相色谱-质谱
下载PDF
基于多元统计学分析^(60)Co-γ射线辐照对川芎挥发性成分的影响
18
作者 王艳 孟爱莲 +7 位作者 贾鑫 叶嘉伟 徐攀 张雁君 邱娅璐 何江 毛腾霄 高鹏 《辐射研究与辐射工艺学报》 CAS CSCD 2024年第4期75-88,共14页
川芎挥发性成分是其主要活性成分之一,也是评价川芎药用品质的重要指标。为探究^(60)Co-γ射线辐照对川芎挥发性成分的影响,本研究以不同吸收剂量处理川芎样品,采用电子鼻结合顶空固相微萃取-气相色谱-质谱技术(HS-SPME-GC-MS),通过主... 川芎挥发性成分是其主要活性成分之一,也是评价川芎药用品质的重要指标。为探究^(60)Co-γ射线辐照对川芎挥发性成分的影响,本研究以不同吸收剂量处理川芎样品,采用电子鼻结合顶空固相微萃取-气相色谱-质谱技术(HS-SPME-GC-MS),通过主成分分析、线性判别分析、正交偏最小二乘法和聚类分析的多元统计学方法分析数据,以期了解川芎辐照前后挥发性成分的变化。电子鼻与GC-MS结果都表明:川芎气味主要由烷烃类、醇类、醛类、酮类贡献,10 kGy剂量以下的辐照处理对川芎挥发性气味成分影响不大;川芎经0 kGy(对照组)、3 kGy、7 kGy、10 kGy剂量辐照处理后,共鉴定出60种化合物,其中烃类23种,醇类12种,脂类10种,醛酮类4种,其他类11种;筛选到21种辐照前后的差异特征性指标物,它们在川芎挥发性成分中只占约12.92%,不是川芎的主要挥发性成分。经10 kGy剂量以下的辐照处理后,川芎中没有新生成的物质被鉴定出来。研究结果提示经10 kGy以下剂量处理川芎不会影响其主要挥发性成分。 展开更多
关键词 川芎 辐照 挥发性成分 顶空固相微萃取-气相色谱-质谱技术 多元统计学分析
下载PDF
基于顶空固相微萃取-气相色谱-质谱法分析加速氧化过程中全脂牛羊乳粉挥发性化合物
19
作者 薛海燕 李欣雨 +4 位作者 孟毅 贺宝元 张磊 刘晓凤 马军 《食品科学》 EI CAS CSCD 北大核心 2024年第10期272-280,共9页
为探究全脂牛羊乳粉在储存过程中风味物质的变化,本研究采用顶空固相微萃取-气相色谱-质谱技术对加速氧化过程中全脂牛羊乳粉挥发性化合物进行分析。研究表明,全脂牛乳粉和全脂羊乳粉中分别鉴定出56、63种挥发性物质,主要为酸类、醇类... 为探究全脂牛羊乳粉在储存过程中风味物质的变化,本研究采用顶空固相微萃取-气相色谱-质谱技术对加速氧化过程中全脂牛羊乳粉挥发性化合物进行分析。研究表明,全脂牛乳粉和全脂羊乳粉中分别鉴定出56、63种挥发性物质,主要为酸类、醇类、羰基类、酯类、芳香族类、杂环类等挥发性化合物。通过主成分分析和聚类热图分析,在全脂牛羊乳粉中筛选出10种显著性差异挥发性化合物,全脂牛乳粉在储存过程中丁酸相对含量降低,2-壬酮、1-氯戊烷相对含量升高;全脂羊乳粉中壬醛、辛酸、丙酸、丁羟甲苯相对含量降低,苯甲醛、2-庚酮、烯丙基正丙酯相对含量升高。 展开更多
关键词 全脂牛乳粉 全脂羊乳粉 顶空固相微萃取-气相色谱-质谱联用 挥发性化合物
下载PDF
直接浸入式固相微萃取-气相色谱法同时测定调味品中的山梨酸、苯甲酸和脱氢乙酸含量
20
作者 冯竟 杨飞 +3 位作者 龚羽婷 郭研研 陈文豪 董浩 《食品安全质量检测学报》 CAS 2024年第15期249-254,共6页
目的建立直接浸入固相微萃取结合气相色谱法同时测定调味品中3种常见防腐剂(山梨酸、苯甲酸、脱氢乙酸)含量的分析方法。方法本研究对直接浸入固相微萃取的多个关键参数,包括萃取温度、萃取时间和盐酸添加量,进行了系统优化,以寻求最佳... 目的建立直接浸入固相微萃取结合气相色谱法同时测定调味品中3种常见防腐剂(山梨酸、苯甲酸、脱氢乙酸)含量的分析方法。方法本研究对直接浸入固相微萃取的多个关键参数,包括萃取温度、萃取时间和盐酸添加量,进行了系统优化,以寻求最佳的萃取效率。采用气相色谱仪进行测定,并利用外标法进行定量分析。对建立的直接浸入固相微萃取结合气相色谱法进行了全面的方法学评价,并实际应用于调味品样品的检测。结果3种防腐剂在标准曲线范围内均呈现出优异的线性关系,相关系数(r)≥0.9960,方法的检出限为0.08~0.96 mg/L,定量限为0.25~3.20 mg/L,回收率为92.8%~106.3%。结论该方法操作简便、灵敏度高、结果准确可靠,为同时检测调味品中山梨酸、苯甲酸、脱氢乙酸含量提供了有效技术手段,在食品安全检测领域具有一定的应用价值和推广前景。 展开更多
关键词 直接浸入式固相微萃取 气相色谱 防腐剂 调味品
下载PDF
上一页 1 2 141 下一页 到第
使用帮助 返回顶部