期刊文献+
共找到298篇文章
< 1 2 15 >
每页显示 20 50 100
Solid-phase microextraction of endogenous metabolites from intact tissue validated using a Biocrates standard reference method kit 被引量:1
1
作者 Runshan Will Jiang Karol Jaroch Janusz Pawliszyn 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2023年第1期55-62,共8页
Improved analytical methods for the metabolomic profiling of tissue samples are constantly needed.Currently,conventional sample preparation methods often involve tissue biopsy and/or homogenization,which disrupts the ... Improved analytical methods for the metabolomic profiling of tissue samples are constantly needed.Currently,conventional sample preparation methods often involve tissue biopsy and/or homogenization,which disrupts the endogenous metabolome.In this study,solid-phase microextraction(SPME)fibers were used to monitor changes in endogenous compounds in homogenized and intact ovine lung tissue.Following SPME,a Biocrates AbsoluteIDQ assay was applied to make a downstream targeted metabolomics analysis and confirm the advantages of in vivo SPME metabolomics.The AbsoluteIDQ kit enabled the targeted analysis of over 100 metabolites via solid-liquid extraction and SPME.Statistical analysis revealed significant differences between conventional liquid extractions from homogenized tissue and SPME results for both homogenized and intact tissue samples.In addition,principal component analysis revealed separated clustering among all the three sample groups,indicating changes in the metabolome due to tissue homogenization and the chosen sample preparation method.Furthermore,clear differences in free metabolites were observed when extractions were performed on the intact and homogenized tissue using identical SPME procedures.Specifically,a direct comparison showed that 47 statistically distinct metabolites were detected between the homogenized and intact lung tissue samples(P<0.05)using mixed-mode SPME fibers.These changes were probably due to the disruptive homogenization of the tissue.This study's findings highlight both the importance of sample preparation in tissue-based metabolomics studies and SPME's unique ability to perform minimally invasive extractions without tissue biopsy or homogenization while providing broad metabolite coverage. 展开更多
关键词 solid-phase microextraction Solvent extraction Metabolomics Sample preparation In vivo sampling
下载PDF
Comparison of different approaches for direct coupling of solid-phase microextraction to mass spectrometry for drugs of abuse analysis in plasma
2
作者 Wei Zhou Martyna N.Wieczorek +1 位作者 Runshan Will Jiang Janusz Pawliszyn 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2023年第2期216-222,共7页
The direct coupling of solid-phase microextraction(SPME)to mass spectrometry(MS)(SPME-MS)has proven to be an effective method for the fast screening and quantitative analysis of compounds in complex matrices such as b... The direct coupling of solid-phase microextraction(SPME)to mass spectrometry(MS)(SPME-MS)has proven to be an effective method for the fast screening and quantitative analysis of compounds in complex matrices such as blood and plasma.In recent years,our lab has developed three novel SPME-MS techniques:SPME-microfluidic open interface-MS(SPME-MOI-MS),coated blade spray-MS(CBS-MS),and SPME-probe electrospray ionization-MS(SPME-PESI-MS).The fast and high-throughput nature of these SPME-MS technologies makes them attractive options for point-of-care analysis and anti-doping testing.However,all these three techniques utilize different SPME geometries and were tested with different MS instruments.Lack of comparative data makes it difficult to determine which of these methodologies is the best option for any given application.This work fills this gap by making a comprehensive comparison of these three technologies with different SPME devices including SPME fibers,CBS blades,and SPME-PESI probes and SPME-liquid chromatography-MS(SPME-LC-MS)for the analysis of drugs of abuse using the same MS instrument.Furthermore,for the first time,we developed different desorption chambers for MOI-MS for coupling with SPME fibers,CBS blades,and SPME-PESI probes,thus illustrating the universality of this approach.In total,eight analytical methods were developed,with the experimental data showing that all the SPME-based methods provided good analytical performance with R^(2)of linearities larger than 0.9925,accuracies between 81%and 118%,and good precision with an RSD%≤13%. 展开更多
关键词 solid-phase microextraction Mass spectrometry Microfluidic open interface Coated blade spray Probe electrospray ionization Drug of abuse
下载PDF
Scalable solid-phase synthesis of defect-rich graphene for oxygen reduction electrocatalysis 被引量:1
3
作者 Chunxiao Dong Li Yang +4 位作者 Cheng Lian Xiaoling Yang Yihua Zhu Hongliang Jiang Chunzhong Li 《Green Energy & Environment》 SCIE EI CSCD 2023年第1期224-232,共9页
Defect-engineered carbon materials have been emerged as promising electrocatalysts for oxygen reduction reaction(ORR)in metal-air batteries.Developing a facile strategy for the preparation of highly active nanocarbon ... Defect-engineered carbon materials have been emerged as promising electrocatalysts for oxygen reduction reaction(ORR)in metal-air batteries.Developing a facile strategy for the preparation of highly active nanocarbon electrocatalysts remains challenging.Herein,a low-cost and simple route is developed to synthesize defective graphene by pyrolyzing the mixture of glucose and carbon nitride.Molecular dynamics simulations reveal that the graphene formation is ascribed to two-dimensional layered feature of carbon nitride,and high compatibility of carbon nitride/glucose systems.Structural measurements suggest that the graphene possesses rich edge and topological defects.The graphene catalyst exhibits higher power density than commercial Pt/C catalyst in a primary Zn-air battery.Combining experimental results and theoretical thermodynamic analysis,it is identified that graphitic nitrogen-modified topological defects at carbon framework edges are responsible for the decent ORR performance.The strategy presented in this work can be can be scaled up readily to fabricate defective carbon materials. 展开更多
关键词 Carbon materials ELECTROCATALYSIS Oxygen reduction reaction solid-phase synthesis Zn-air battery
下载PDF
Carbon Doping Triggered Efficient Electrochemical Hydrogen Evolution of Cross-Linked Porous Ru-MoO_(2) Via Solid-Phase Reaction Strategy 被引量:1
4
作者 Jialin Cai Jianye Yang +7 位作者 Xin Xie Jie Ding Leyan Liu Wanyu Tian Yushan Liu Zhiyong Tang Baozhong Liu Siyu Lu 《Energy & Environmental Materials》 SCIE EI CAS CSCD 2023年第1期392-400,共9页
The defect-free structure of Mo-based materials is a“double-edged sword”,which endows the material with excellent stability,but limits its chemical versatility and application in electrochemical hydrogen evolution r... The defect-free structure of Mo-based materials is a“double-edged sword”,which endows the material with excellent stability,but limits its chemical versatility and application in electrochemical hydrogen evolution reaction(HER).Carbon doping engineering is an attractive strategy to effectively improve the performance of Mo-based catalyst and maintain their stability.Herein,we report a cross-linked porous carbon-doped MoO_(2)(C–MoO_(2))-based catalyst Ru/C–MoO_(2) for electrochemical HER,which is prepared by the convenient redox solid-phase reaction(SPR)of porous RuO_(2)/Mo_(2)C composite precursor.Theoretical studies reveal that due to the presence of carbon atoms,the electronic structure of C–MoO_(2) has been properly adjusted,and the loaded small Ru nanoparticles provide a fast water dissociation rate and moderate H adsorption strength.In electrochemical studies under a pH-universal environment,Ru/C–MoO_(2) electrocatalyst exhibits a low overpotential at a current density of 10 mA cm^(-2) and has a low Tafel slope.Meanwhile,Ru/C-MoO_(2) has excellent stability for more than 100 h at an initial current density of 100 mA cm^(-2). 展开更多
关键词 carbon doped hydrogen evolution reaction macro-meso-micropore MoO_(2) RU solid-phase reaction
下载PDF
Comparison of Headspace Solid-Phase Microextraction with Simultaneous Steam Distillation Extraction for the Analysis of the Volatile Constituents in Chinese Apricot 被引量:20
5
作者 CHEN Mei-xia CHEN Xue-sen +4 位作者 WANG Xin-guo CI Zhi-juan LIU Xiao-li HE Tian-ming ZHANG Li-jie 《Agricultural Sciences in China》 CAS CSCD 2006年第11期879-884,共6页
Volatile constituents in fully mature fruits of apricot (Prunus armeniaca L.) cultivar Xinshiji were extracted using headspace solid-phase microextraction (HS-SPME) and simultaneous steam distillation extraction ... Volatile constituents in fully mature fruits of apricot (Prunus armeniaca L.) cultivar Xinshiji were extracted using headspace solid-phase microextraction (HS-SPME) and simultaneous steam distillation extraction (SSDE) and then analyzed using capillary gas chromatography and gas chromatography-mass spectrometry. A total of 70 components were identified by HSSPME, including 20 esters, 19 hydrocarbons, 5 alcohols, 5 ketones, 4 acids, 4 lactones, 3 aldehydes, and 10 miscellaneous components, with the esters being the dominant constituent. On the basis of the odor unit values, it is believed that the following compounds probably contributed to the fresh apricot odor: hexyl acetate, β-ionone, butyl acetate, (E)-2-hexenal, linalool, limonene, γ-decalactone, and hexanal. A total of 49 components were also detected by SSDE, including 13 hydrocarbons, 9 alcohols, 7 aldehydes, 9 esters, 4 ketones, 4 lactones, 2 acids, and 1 miscellaneous component, of which the monoterpene alcohols were the dominant constituents. It could be judged from the odor unit values that the following compounds were the major contributors to boiled apricot aroma: β-ionone, linalool, hexyl acetate, γ-dodecalactone, γ- decalactone, (E)-2-hexenal, hexanal, γ-octalactone, phenylacetaldehyde, butyl acetate, limonene, α-terpineol, and δ-decalactone. The results show that HS-SPME is a simple, rapid, and solvent-free method, which is an alternative to the classical SSDE. 展开更多
关键词 AROMA volatile constituents APRICOT solid-phase microextraction simultaneous distillation-extraction
下载PDF
Preparation of polypyrrole/nanosilica composite for solid-phase microextraction of bisphenol and phthalates migrated from containers to eye drops and injection solutions 被引量:2
6
作者 Mehdi Ansari Dogaheh Mansoureh Behzadi 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2019年第3期185-192,共8页
This paper describes the electrodeposition of polyphosphate-doped polypyrrole/nanosilica nano-composite coating on steel wire for direct solid-phase microextraction of bisphenol A and five phthalates. We optimized inf... This paper describes the electrodeposition of polyphosphate-doped polypyrrole/nanosilica nano-composite coating on steel wire for direct solid-phase microextraction of bisphenol A and five phthalates. We optimized influencing parameters on the extraction efficiency and morphology of the nanocomposite such as deposition potential, concentration of pyrrole and polyphosphate, deposition time and the nanosilica amount. Under the optimized conditions, characterization of the nanocomposite was inves-tigated by scanning electron microscopy and Fourier transform infra-red spectroscopy. Also, the factors related to the solid-phase microextraction method including desorption temperature and time, extrac-tion temperature and time, ionic strength and pH were studied in detail. Subsequently, the proposed method was validated by gas chromatography-mass spectrometry by thermal desorption and acceptable figures of merit were obtained. The linearity of the calibration curves was between 0.01 and 50 ng/mL with acceptable correlation coefficients (0.9956-0.9987) and limits of detection were in the range 0.002-0.01 ng/mL. Relative standard deviations in terms of intra-day and inter-day by five replicate analyses from aqueous solutions containing 0.1 ng/mL of target analytes were in the range 3.3%-5.4% and 5%-7.1%, respectively. Fiber-to-fiber reproducibilities were measured for three different fibers prepared in the same conditions and the results were between 7.3% and 9.8%. Also, extraction recoveries at two different concentrations were ≥96%. Finally, the suitability of the proposed method was demonstrated through its application to the analysis of some eye drops and injection solutions. 展开更多
关键词 solid-phase microextrACTION Gas chromatography-mass spectrometry Polyphosphate-doped POLYPYRROLE NANOSILICA PHTHALATES BisphenolA
下载PDF
Covalent organic nanospheres as a fiber coating for solid-phase microextraction of genotoxic impurities followed by analysis using GC-MS 被引量:2
7
作者 Yanfang Zhao Jingkun Li +2 位作者 Hanyi Xie Huijuan Li Xiangfeng Chen 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2022年第4期583-589,共7页
Covalent organic nanospheres(CONs)were explored as a fiber coating for solid-phase microextraction of genotoxic impurities(GTIs)from active ingredients(AIs).CONs were synthesized by an easy solutionphase procedure at... Covalent organic nanospheres(CONs)were explored as a fiber coating for solid-phase microextraction of genotoxic impurities(GTIs)from active ingredients(AIs).CONs were synthesized by an easy solutionphase procedure at 25℃.The obtained nanospheres exhibited a high specific surface area,good thermostability,high acid and alkali resistance,and favorable crystallinity and porosity.Two types of GTIs,alkyl halides(1-iodooctane,1-chlorobenzene,1-bromododecane,1,2-dichlorobenzene,1-bromooctane,1-chlorohexane,and 1,8-dibromooctane)and sulfonate esters(methyl p-toluenesulfonate and ethyl ptoluenesulfonate),were chosen as target molecules for assessing the performance of the coating.The prepared coating achieved high enhancement factors(5097-9799)for the selected GTIs.The strong affinity between CONs and GTIs was tentatively attributed to π-π and hydrophobicity interactions,large surface area of the CONs,and size-matching of the materials.Combined with gas chromatography-mass spectrometry(GC-MS),the established analytical method detected the GTIs in capecitabine and imatinib mesylate samples over a wide linear range(0.2-200 ng/g)with a low detection limit(0.04-2.0 ng/g),satisfactory recovery(80.03%-109.5%),and high repeatability(6.20%-14.8%)and reproducibility(6.20%-14.1%).Therefore,the CON-coated fibers are promising alternatives for the sensitive detection of GTIs in AI samples. 展开更多
关键词 Covalent organic nanospheres solid-phase microextraction Genotoxic impurities Gas chromatography-mass spectrometry
下载PDF
Flash Evaporation and Headspace Solid-phase Microextraction for the Analysis of the Essential Oils in Traditional Chinese Medicine,Houttuynia Cordata Thunb 被引量:1
8
作者 MinMinLIANG MeiLingQI RuoNongFU 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第5期659-662,共4页
We have investigated the use of flash evaporation, headspace solid-phase microextraction (HS-SPME) and steam distillation (SD) as sample concentration and preparation techniques for the analysis of volatile constituen... We have investigated the use of flash evaporation, headspace solid-phase microextraction (HS-SPME) and steam distillation (SD) as sample concentration and preparation techniques for the analysis of volatile constituents present in Houttuynia cordata Thunb. The samples were analyzed by gas chromatography (GC) and identified by mass spectrometry (MS). Comparison studies were performed. It was found that the results obtained between Headspace solid-phase microextraction HS-SPME and SD techniques were in good agreement. Seventy-nine compounds in Houttuynia cordata Thunb were identified by MS. In flash evaporation, thirty-nine compounds were identified. Discrimination in the response for many constituents studied was not observed, which can be clearly observed in SD and HS-SPME techniques. As a conclusion, HS-SPME is a powerful tool for determining the volatile constitutes present in the Houttuynia cordata. 展开更多
关键词 Headspace solid-phase microextraction flash evaporation essential oils GC-MS.
下载PDF
Sol-Gel-Coated Calix[4]arene Fiber for Solid-Phase Microextraction
9
作者 LiXiu-juan XiaoRui-min +1 位作者 LiHai-bing ZengZhao-rui 《Wuhan University Journal of Natural Sciences》 CAS 2003年第04A期1153-1155,共3页
5, 11, 17, 23-tetra-tert-butyl-25, 27-diethoxy-26, 28-dihydroxycalix \ arene /hydroxy-terminated silicone oil coated fiber was first prepared and applied for solid-phase microextraction with sol-gel technology. The pr... 5, 11, 17, 23-tetra-tert-butyl-25, 27-diethoxy-26, 28-dihydroxycalix \ arene /hydroxy-terminated silicone oil coated fiber was first prepared and applied for solid-phase microextraction with sol-gel technology. The properties of the new coating were investigated by analysis of benzene derivatives, polycyclic aromatic hydrocarbons and aromatic amines. The fiber is characterized by good sensitivity and selectivity to these aromatics. The fiber has stable performance at a high temperature of 380℃ and after a long solvent immersing, thus its lifetime is very long. It shows good fiber-to-fiber and batch-to-batch reproducibility. Furthermore, broad linear ranges and low detection limits are also its characteristics. 展开更多
关键词 solid-phase microextraction SOL-GEL CALIXARENE aromatic compounds
下载PDF
Solid-phase Microextraction with Benzoxy-calix[6]arene Fiber Coupled to Gas Chromatography for the Analysis of Polycyclic Aromatic Hydrocarbons in Water
10
作者 YE Chang-wen ZHANG Xue-na HUANG Jiang-yan LI Xiu-juan PAN Si-yi 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第2期198-202,共5页
Headspace solid-phase microextraction(HS-SPME) with sol-gel calix[6]arene-containing fiber followed by gas chromatography with a flame ionization detector was used to examine the composition and distribution of seve... Headspace solid-phase microextraction(HS-SPME) with sol-gel calix[6]arene-containing fiber followed by gas chromatography with a flame ionization detector was used to examine the composition and distribution of seven polycyclic aromatic hydrocarbons(PAHs) in water. The novel SPME fiber exhibited higher extraction efficiency to PAHs compared with poly(dimethylsiloxane) and other calixarene-containing fibers. Extraction/retention mechanism based on the interactions between calixarenes and PAHs was discussed. Owing to the good selectivity and high extraction capability of this calixarene fiber, low detection limits were obtained in a range of 0.34―6.50 ng/L and the relative standard deviation values were ≤12.3% for all of the analytes. The linear ranges of the proposed method were five orders of magnitude for the tested compounds, with linear correlation coefficients(r) greater than 0.998. The method was applied to the determination of polycyclic aromatic hydrocarbons in nine water sources in Wuhan City, China. Standard addition method was selected for the quantification and the recovery values were in a satisfactory range. Total PAHs concentrations in the nine surface water samples were found to vary between undetectable and 8.840 μg/L with two- and three-ring PAHs predominating. 展开更多
关键词 Polycyclic aromatic hydrocarbon solid-phase microextraction CALIXARENE Gas chromatography WATER
下载PDF
Preparation of A New Fiber by Sol-gel Technology in Solid-phase Microextraction (SPME)
11
作者 LiMingWEI QingYuOU JuBaiLI 《Chinese Chemical Letters》 SCIE CAS CSCD 2004年第9期1127-1130,共4页
The sol-gel technology is applied for the preparation of solid-phase microextraction (SPME) fiber. The fiber demonstrates high thermal stability, efficient extraction rate and the selectivity for non-polar or low-pol... The sol-gel technology is applied for the preparation of solid-phase microextraction (SPME) fiber. The fiber demonstrates high thermal stability, efficient extraction rate and the selectivity for non-polar or low-polar analytes. Efficient SPME-GC-FID analyses of benzene- toluene-ethylbenzene-xylenes (BTEXs) and low-polar halocarbon were achieved by the sol-gel coated DSDA-DDBT-TiO2 fiber. Some parameters of the SPME fiber for the determination of halocarbon in aqueous sample were investigated. 展开更多
关键词 solid-phase microextraction sol-gel technology SELECTIVITY polyimide (DSDA-DDBT).
下载PDF
Time-course monitoring of in vitro biotransformation reaction via solid-phase microextraction-ambient mass spectrometry approaches
12
作者 Karol Jaroch Janusz Pawliszyn 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2022年第1期186-191,共6页
The solid-phase microextraction technique quantifies analytes without considerably affecting the sample composition.Herein,a proof-of-concept study was conducted to demonstrate the use of coated probe electrospray ion... The solid-phase microextraction technique quantifies analytes without considerably affecting the sample composition.Herein,a proof-of-concept study was conducted to demonstrate the use of coated probe electrospray ionization(coated-PESI)and coated blade spray(CBS)as ambient mass spectrometry approaches for monitoring drug biotransformation.The ability of these methods was investigated for monitoring the dephosphorylation of a prodrug,combretastatin A4 phosphate(CA4P),into its active form,combretastatin A4(CA4),in a cell culture medium supplemented with fetal bovine serum.The CBS spot analysis was modified to achieve the same extraction efficiency as protein precipitation and obtained results in 7 min.Because coated-PESI performs extraction without consuming any samples,it is the preferred technique in the case of a limited sample volume.Although coated-PESI only extracts small quantities of analytes,it uses the desorption solvent volume of 5-10 pL,resulting in high sensitivity,thus allowing the detection of compounds after only 1 min of extraction.The biotransformation of CA4P into CA4 via phosphatases occurs within the simple matrix,and the proposed sample preparation techniques are suitable for monitoring the biotransformation. 展开更多
关键词 solid-phase microextraction Coated probe electrospray ionization Coated blade spray COMBRETASTATIN BIOTRANSFORMATION Prodrug activation
下载PDF
Application of Phenyl Bonded Mesoporous Silica as A Novel Coating Layer of Solid-phase Microextraction for Determination of Benzo[a]pyrene in Water Samples
13
作者 XinZhenDU YaRongWANG QianMA XueFengMAO JinGuoHOU 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第6期801-804,共4页
Phenyl bonded mesoporous silica (C6H5-MCM-41) was applied as the fiber coating of solid-phase microextraction (SPME). The performance of the fiber coating was discussed coupling to HPLC. Applicability of mesoporous fi... Phenyl bonded mesoporous silica (C6H5-MCM-41) was applied as the fiber coating of solid-phase microextraction (SPME). The performance of the fiber coating was discussed coupling to HPLC. Applicability of mesoporous fiber coating was examined for the determination of benzo[a]pyrene (B[a]P) in water samples. The limit of detection (LOD) is 0.28μg·L-1. Good recovery and relative standard deviation (RSD) were obtained. 展开更多
关键词 Mesoporous silica solid-phase microextraction HPLC benzo[a]pyrene.
下载PDF
Determination of Trihalomethanes in Water Samples Using Headspace Solid-Phase Microextraction Gas Chromatography
14
作者 Nitaya Saesim Wanna Kanchanamayoon 《Journal of Chemistry and Chemical Engineering》 2010年第6期1-7,共7页
The chlorination process is one of the water treatment method used for the disinfection of water. The disinfection by products are trihalomethanes such as chloroform, dichloromethane, dibromochloromethane and bromofor... The chlorination process is one of the water treatment method used for the disinfection of water. The disinfection by products are trihalomethanes such as chloroform, dichloromethane, dibromochloromethane and bromoform. A headspace solid-phase microextraction method has been developed for determination oftrihalomethanes in water samples. The experimental parameters such as the stirring rate, extraction time, extraction temperature and desorption time were investigated. The linearity, detection limits and percentage recovery were evaluated. The optimum conditions were stirring rate 800 rpm/min, extraction time 6 min, extraction temperature 20 ~C, desorption time 2.5 min and desorption temperature 220 ~C. The detection limits were 0.01 ~g/L and the recoveries were in the range of 86-110 %, The proposed method was successfully applied to determination of THM4 in tap water samples. The THM4 contents were varied depending on the sample sites and the season. The total THM4 contents in cool, summer and rainy season were in the range of 27.58-41.89, 32.06-60.73 and 46.26-69.87 p.g/L, respectively. Confirmation of the detected compounds in water samples were performed by gas chromatograph-mass spectrometer. The mass spectra of the target compounds in water samples is in good agreement with trihalomethanes standard spectra. 展开更多
关键词 Water analysis gas chromatography TRIHALOMETHANES disinfection by product solid-phase microextraction.
下载PDF
Solid-phase microextraction for flavor analysis in Harari Khat (Catha edulis) stimulant
15
作者 AL-FLAHIAbdulsalam 邹建凯 殷学锋 《Journal of Zhejiang University Science》 EI CSCD 2004年第4期428-431,共4页
This research examined the typical flavor compounds in the commonest type of Khat called Harari Khat grown in the region of Ethiopia.Twenty-eight compounds, which includes 1,2-Propanedione,1-Phenyl,Hexanol,Hexanal com... This research examined the typical flavor compounds in the commonest type of Khat called Harari Khat grown in the region of Ethiopia.Twenty-eight compounds, which includes 1,2-Propanedione,1-Phenyl,Hexanol,Hexanal compounds,Limonene, Benzaldehyde with other flavors, were extracted by polydimethylsiloxane at room temperature for 30min from Khat samples,and identified by solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS).This method needs no organic solvents and required minimal sample. 展开更多
关键词 solid-phase microextraction Gas chromatography-mass spectrometry CATHA Khat leaves Khat in Yemen Chat (Khat) in Ethiopia
下载PDF
Determination of Aroma Composition of Santalum album Linn by Solid-phase Microextraction-Gas Chromatography-Mass Spectrometry
16
作者 Guotong CHEN Meiqin LI +2 位作者 Chao HUANG Na WEN Aixia WANG 《Asian Agricultural Research》 2020年第9期43-45,共3页
[Objectives]This study aimed to determine the volatile components in Santalum album Linn and gradually clarify the aroma composition of S.album Linn.[Methods]Solid-phase microextraction method was used to obtain the v... [Objectives]This study aimed to determine the volatile components in Santalum album Linn and gradually clarify the aroma composition of S.album Linn.[Methods]Solid-phase microextraction method was used to obtain the volatile components of S.album Linn.The aroma components were analyzed by gas chromatography-mass spectrometry and their relative contents were calculated using the area normalization method.[Results]In a dry state at room temperature,39 chemical components were identified from S.album Linn,mainly olefins(91.15%),alkanes(3.00%),alcohols(2.56%),esters(2.19%),ketones(0.55%),aldehydes(0.41%)and heterocyclics(0.14%).[Conclusions]This method has the advantages of low sample consumption,easy operation,rapid identification of aroma components and high sensitivity,and can effectively separate and determine volatile components in S.album Linn,realizing the rapid identification of different S.album Linn varieties and providing technical support for further research on Chinese medicinal materials. 展开更多
关键词 Santalum album Linn solid-phase microextraction(SPME) Gas chromatography-mass spectrometry Aroma component
下载PDF
Low temperature solid-phase sintering of sintered metal fibrous media with high specific surface area 被引量:4
17
作者 唐彪 汤勇 +3 位作者 周蕤 陆龙生 刘彬 屈修明 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2011年第8期1755-1760,共6页
A procedure of low temperature solid-phase sintering(LTSS) was carried out to fabricate sintered metal fibrous media(SMFM) with high specific surface area.Stainless steel fibers which were produced by cutting proc... A procedure of low temperature solid-phase sintering(LTSS) was carried out to fabricate sintered metal fibrous media(SMFM) with high specific surface area.Stainless steel fibers which were produced by cutting process were first plated with a coarse copper coating layer by electroless plating process.A low-temperature sintering process was then completed at about 800 °C for 1 h under the protection of hydrogen atmosphere.The results show that a novel SMFM with complex surface morphology and high specific surface area(0.2 m2/g) can be obtained in this way.The effect of sintering temperature on the surface morphology and specific surface area of SMFM was studied by means of scanning electron microscopy and Brunauer-Emmett-Teller.The damage of micro-structure during the sintering process mainly contributed to the loss of specific surface area of SMFM and the optimal sintering temperature was 800 °C. 展开更多
关键词 sintered metal fibrous media low temperature solid-phase sintering electroless copper plating surface morphology specific surface area
下载PDF
Solid-phase sintering process and forced convective heat transfer performance of porous-structured micro-channels 被引量:2
18
作者 白鹏飞 易子川 +1 位作者 唐彪 周国富 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2014年第3期900-906,共7页
A solid-phase sintering process for the low-cost fabrication of composite micro-channels was developed. Three kinds of composite micro-channels with metallic porous structures were designed. The sintering process was ... A solid-phase sintering process for the low-cost fabrication of composite micro-channels was developed. Three kinds of composite micro-channels with metallic porous structures were designed. The sintering process was studied and optimized to obtain porous-structured micro-channels with high porosity. The flow resistance and heat transfer performance in the composite micro-channels were investigated. The composite micro-channels show acceptable flow resistance, significant enhancement of heat transfer and dramatic improvement of flow boiling stability, which indicates a promising prospect for the application in forced convective heat transfer. 展开更多
关键词 solid-phase sintering composite micro-channels porous structure flow resistance convective heat transfer
下载PDF
Chemiluminescence Determination of Benzoic Acid Using A Solid-Phase Verdigris Reactor 被引量:1
19
作者 王晓妮 张洁 《Chinese Chemical Letters》 SCIE CAS CSCD 2003年第3期283-286,共4页
A new chemiluminescence flow system has been developed for sequential determina-tion of benzoic acid based on the reaction of the compound with copper carbonate entrapped in a solid-phase reactor. It was found that t... A new chemiluminescence flow system has been developed for sequential determina-tion of benzoic acid based on the reaction of the compound with copper carbonate entrapped in a solid-phase reactor. It was found that the unsaturated complex of Cu(II) and benzoic acid (1:1) has strong catalytic effect on the luminol-H2O2 chemiluminescence reaction. The calibration graph is linear over the range of 0.025 ~ 60 g/mL of benzoic acid, with a relative standard deviation of less than 3.0 %, and the detection limit is 0.01礸穖L-1. The proposed method was applied to the determination of benzoic acid content in different pharmaceutical formulations. 展开更多
关键词 Benzoic acid CHEMILUMINESCENCE solid-phase reactor pharmaceutical formulations.
下载PDF
Determination of phthalate esters in fat-containing foods by packed nanofiber solid-phase extraction column and gas chromatography 被引量:1
20
作者 邱金丽 王羽 +1 位作者 周小玲 康学军 《Journal of Southeast University(English Edition)》 EI CAS 2016年第3期322-326,共5页
A new method for simultaneous determination of four phthalate esters ( PAEs) in commercial fat-containing foods was developed by the combination of a packed nanofibers column based on solid-phase extraction with gas... A new method for simultaneous determination of four phthalate esters ( PAEs) in commercial fat-containing foods was developed by the combination of a packed nanofibers column based on solid-phase extraction with gas chromatography-flame ionization detector ( GC-FID ). Conditions for obtaining optimum extraction efficiency such as extraction solvents, morphologies of adsorbent, ion strength and pH were investigated and optimized in detail. Under the optimized conditions, the limits of detection (LODs) found for dibutyl phthalate (DBP) , butyl benzyl phthalate (BBP), diethyl hexyl phthalate (DEHP) and di-n-octyl phthalate (DNOP) were 50, 25, 50 and 25 ng/g, respectively. Good linearity of four PAEs was achieved in the range of 50 to 4 000 ng/g. The proposed method was applied for analyzing different kinds of fat-containing samples. PAEs in commercial fat-containing samples can be highly extracted by a packed solid-phase extraction column of 5 mg polystyrene ( PS) nanofibers. The satisfactory average recoveries were obtained in the range of 96. 7% to 102. 3% , and the relative standard deviations (RSDs) below 5% were achieved. The proposed method reduces the organic solvent consumption, the complex and tedious procedures for sample pretreatment, and achieves high sensitivity and reproducibility for the investigated PAEs. 展开更多
关键词 phthalate esters (PAEs nanofibers solid-phase extraction gas chromatography fat-containing foods
下载PDF
上一页 1 2 15 下一页 到第
使用帮助 返回顶部