The phytotoxicity of chlorobenzoic acids(CBAs) was studied and the biochemical endpoints' suitability and sensibility was evaluated. Two terrestrial plant species in the same family were exposed to different conce...The phytotoxicity of chlorobenzoic acids(CBAs) was studied and the biochemical endpoints' suitability and sensibility was evaluated. Two terrestrial plant species in the same family were exposed to different concentrations of CBAS and tested their germination according to the guideline of Organization for Economic Cooperation and Development(OECP, 1984). The results showed that CBA dose-inhibition rate of classical endpoint had the distinct linear relationship in the range of 10%—50% inhibition rate for root elongation(p<0.01), and the dose variances of CBAs had the greater influence on the inhibition rate of germination than on inhibition rate of root elongation. The CBA dose half effect concentration-inhibition rate of two antioxidant enzyme activity superoxide dismutase(SOD) and catalase (CAT) had the quadratic relationship, and CBA dose-inhibition rate of the peroxides(POD) activity had the linear relationship(p<0.05). Comparing the half effect concentration (EC_ 50) of two kinds of endpoints, the POD activity was more sensitive than classical endpoint, however, SOD and CAT activity were not sensitive in the experiment.展开更多
The paper presents a new method to determine the sensible effectiveness and pressure loss of rotary regenerative heat exchangers using computational fluid dynamics(CFD).It is based on CFD simulations of a single therm...The paper presents a new method to determine the sensible effectiveness and pressure loss of rotary regenerative heat exchangers using computational fluid dynamics(CFD).It is based on CFD simulations of a single thermal wheel microchannel with a small cross-sectional area and thin walls,with cyclic inlet and outlet boundary conditions.Two unique measurement set-ups were designed and built for the experimental measurement of the heat exchanger characteristics.Five different types of thermal wheels were manufactured,measured,and simulated in ANSYS Fluent.All wheels achieve an effectiveness greater than 73%under certain(air flow)conditions,which is the minimum effectiveness required by Ecodesign(in the EU).For the examined exchangers,the effectiveness ranges from 66.5%to 83.3%,depending on the boundary conditions and geometric parameters of the rotors.The highest sensible effectiveness is achieved by heat exchangers with the largest heat exchange surface Ac;on the other hand,these wheels have the largest pressure loss.The paper discusses the use of a simplifiedε-NTU correlation model for the HVAC systems(typically C*=1).The correlation model and CFD results were compared and found to be different from each other.The results of the CFD simulation were compared with measurements to prove that the proposed simulation method can predict the behaviour of the real heat exchanger as a whole.It was demonstrated that the sensible effectiveness and pressure loss of the rotary heat exchanger predicted by the CFD simulations correspond well to the measured values within the measurement uncertainty±1.3%.The proposed method can be used for the comparison of different rotary regenerative heat exchangers before their manufacturing and for verification that they meet the EU Ecodesign requirements set by the current legislation.It reduces the cost of the initial optimisation and testing of new designs.展开更多
基金The National Natural Science Foundation of China(No. 20337010) and the Major State Basic Research Development Program(973) of China (No.2004CB418506)
文摘The phytotoxicity of chlorobenzoic acids(CBAs) was studied and the biochemical endpoints' suitability and sensibility was evaluated. Two terrestrial plant species in the same family were exposed to different concentrations of CBAS and tested their germination according to the guideline of Organization for Economic Cooperation and Development(OECP, 1984). The results showed that CBA dose-inhibition rate of classical endpoint had the distinct linear relationship in the range of 10%—50% inhibition rate for root elongation(p<0.01), and the dose variances of CBAs had the greater influence on the inhibition rate of germination than on inhibition rate of root elongation. The CBA dose half effect concentration-inhibition rate of two antioxidant enzyme activity superoxide dismutase(SOD) and catalase (CAT) had the quadratic relationship, and CBA dose-inhibition rate of the peroxides(POD) activity had the linear relationship(p<0.05). Comparing the half effect concentration (EC_ 50) of two kinds of endpoints, the POD activity was more sensitive than classical endpoint, however, SOD and CAT activity were not sensitive in the experiment.
文摘The paper presents a new method to determine the sensible effectiveness and pressure loss of rotary regenerative heat exchangers using computational fluid dynamics(CFD).It is based on CFD simulations of a single thermal wheel microchannel with a small cross-sectional area and thin walls,with cyclic inlet and outlet boundary conditions.Two unique measurement set-ups were designed and built for the experimental measurement of the heat exchanger characteristics.Five different types of thermal wheels were manufactured,measured,and simulated in ANSYS Fluent.All wheels achieve an effectiveness greater than 73%under certain(air flow)conditions,which is the minimum effectiveness required by Ecodesign(in the EU).For the examined exchangers,the effectiveness ranges from 66.5%to 83.3%,depending on the boundary conditions and geometric parameters of the rotors.The highest sensible effectiveness is achieved by heat exchangers with the largest heat exchange surface Ac;on the other hand,these wheels have the largest pressure loss.The paper discusses the use of a simplifiedε-NTU correlation model for the HVAC systems(typically C*=1).The correlation model and CFD results were compared and found to be different from each other.The results of the CFD simulation were compared with measurements to prove that the proposed simulation method can predict the behaviour of the real heat exchanger as a whole.It was demonstrated that the sensible effectiveness and pressure loss of the rotary heat exchanger predicted by the CFD simulations correspond well to the measured values within the measurement uncertainty±1.3%.The proposed method can be used for the comparison of different rotary regenerative heat exchangers before their manufacturing and for verification that they meet the EU Ecodesign requirements set by the current legislation.It reduces the cost of the initial optimisation and testing of new designs.