Similar to air reverberation chambers, non-anechoic water tanks are important acoustic measurement devices that can be used to measure the sound power radiated from complex underwater sound sources using diffusion fie...Similar to air reverberation chambers, non-anechoic water tanks are important acoustic measurement devices that can be used to measure the sound power radiated from complex underwater sound sources using diffusion field theory. However,the problem of the poor applicability of low-frequency measurements in these tanks has not yet been solved. Therefore,we propose a low-frequency acoustic measurement method based on sound-field correction(SFC) in an enclosed space that effectively solves the problem of measuring the sound power from complex sound sources below the Schroeder cutoff frequency in a non-anechoic tank. Using normal mode theory, the transfer relationship between the mean-square sound pressure in an underwater enclosed space and the free-field sound power of the sound source is established, and this is regarded as a correction term for the sound field between this enclosed space and the free field. This correction term can be obtained based on previous measurements of a known sound source. This term can then be used to correct the mean-square sound pressure excited by any sound source to be tested in this enclosed space and equivalently obtain its free-field sound power. Experiments were carried out in a non-anechoic water tank(9.0 m × 3.1 m × 1.7 m) to confirm the validity of the SFC method. Through measurements with a spherical sound source(whose free-field radiation characteristics are known),the correction term of the sound field between this water tank and the free field was obtained. On this basis, the sound power radiated from a cylindrical shell model under the action of mechanical excitation was measured. The measurement results were found to have a maximum deviation of 2.9 d B from the free-field results. These results show that the SFC method has good applicability in the frequency band above the first-order resonant frequency in a non-anechoic tank. This greatly expands the potential low-frequency applications of non-anechoic tanks.展开更多
目的研究在声场测试中,头戴式耳机和插入式耳机对不同频率声音的衰减作用。方法选取40名健听人,在声场条件下测试双耳裸耳听阈及双耳分别佩戴头戴式和插入式耳机双耳听阈,耳机均不给声。比较在声场条件下不同类型耳机对不同频率声音的...目的研究在声场测试中,头戴式耳机和插入式耳机对不同频率声音的衰减作用。方法选取40名健听人,在声场条件下测试双耳裸耳听阈及双耳分别佩戴头戴式和插入式耳机双耳听阈,耳机均不给声。比较在声场条件下不同类型耳机对不同频率声音的衰减作用。结果头戴式耳机在0.25~8 kHz每倍频程的声音衰减值分别为6.13±2.40 dB HL、7.00±3.36 dB HL、12.50±3.92 dB HL、18.75±5.03 dB HL、28.25±6.56 dB HL、17.50±5.99 dB HL;插入式耳机在0.25~8 kHz每倍频程的声音衰减值分别为16.88±5.27 dB HL、18.13±5.27 dB HL、22.38±4.08 dB HL、31.25±4.49 dB HL、36.13±5.49 dB HL、35.50±6.68 dB HL。结论两种不同类型耳机对不同频率声音的衰减均有显著效果,对声音的衰减值随着频率的升高而增加,在1~8 kHz范围内效果更显著,插入式耳机的衰减效果明显优于头戴式耳机。展开更多
基金the National Natural Science Foundation of China (Grant No. 11874131)Open Fund Project of Key Laboratory of Underwater Acoustic Countermeasures Technology (Grant No. 2021-JCJQ-LB033-05)。
文摘Similar to air reverberation chambers, non-anechoic water tanks are important acoustic measurement devices that can be used to measure the sound power radiated from complex underwater sound sources using diffusion field theory. However,the problem of the poor applicability of low-frequency measurements in these tanks has not yet been solved. Therefore,we propose a low-frequency acoustic measurement method based on sound-field correction(SFC) in an enclosed space that effectively solves the problem of measuring the sound power from complex sound sources below the Schroeder cutoff frequency in a non-anechoic tank. Using normal mode theory, the transfer relationship between the mean-square sound pressure in an underwater enclosed space and the free-field sound power of the sound source is established, and this is regarded as a correction term for the sound field between this enclosed space and the free field. This correction term can be obtained based on previous measurements of a known sound source. This term can then be used to correct the mean-square sound pressure excited by any sound source to be tested in this enclosed space and equivalently obtain its free-field sound power. Experiments were carried out in a non-anechoic water tank(9.0 m × 3.1 m × 1.7 m) to confirm the validity of the SFC method. Through measurements with a spherical sound source(whose free-field radiation characteristics are known),the correction term of the sound field between this water tank and the free field was obtained. On this basis, the sound power radiated from a cylindrical shell model under the action of mechanical excitation was measured. The measurement results were found to have a maximum deviation of 2.9 d B from the free-field results. These results show that the SFC method has good applicability in the frequency band above the first-order resonant frequency in a non-anechoic tank. This greatly expands the potential low-frequency applications of non-anechoic tanks.
文摘目的研究在声场测试中,头戴式耳机和插入式耳机对不同频率声音的衰减作用。方法选取40名健听人,在声场条件下测试双耳裸耳听阈及双耳分别佩戴头戴式和插入式耳机双耳听阈,耳机均不给声。比较在声场条件下不同类型耳机对不同频率声音的衰减作用。结果头戴式耳机在0.25~8 kHz每倍频程的声音衰减值分别为6.13±2.40 dB HL、7.00±3.36 dB HL、12.50±3.92 dB HL、18.75±5.03 dB HL、28.25±6.56 dB HL、17.50±5.99 dB HL;插入式耳机在0.25~8 kHz每倍频程的声音衰减值分别为16.88±5.27 dB HL、18.13±5.27 dB HL、22.38±4.08 dB HL、31.25±4.49 dB HL、36.13±5.49 dB HL、35.50±6.68 dB HL。结论两种不同类型耳机对不同频率声音的衰减均有显著效果,对声音的衰减值随着频率的升高而增加,在1~8 kHz范围内效果更显著,插入式耳机的衰减效果明显优于头戴式耳机。