In this paper, the suitability and construction technology of self-insulation walls were studied under the specific climatic conditions and regional resources of Hanzhong and Ankang in the hot summer and cold winter z...In this paper, the suitability and construction technology of self-insulation walls were studied under the specific climatic conditions and regional resources of Hanzhong and Ankang in the hot summer and cold winter zone of Southern Shaanxi. Through the calculation of heat transfer coefficient and thermal inertia index, combined with the specifications of the shale hollow brick and aerated concrete block of Hanzhong and Ankang in southern Shaanxi, the thermal performance and suitable thickness of the external wall using self-insulation materials that meet the Design Standard for Energy Efficiency of Residential Buildings(DBJ61-65-2011) in Shaanxi Province were obtained. The results showed that the self-insulation wall had technical suitability in the hot summer and cold winter zone. The research results provide not only a theoretical basis for the external wall insulation design of urban residential buildings in the hot summer and cold winter zone of southern Shaanxi, but also a reference for designers to carry out energy-saving design of external walls of residential buildings in other similar climate zones.展开更多
This paper investigated the applicability and effects of infrared reflective coating on energy consumption of factory building in hot summer and warm winter zone.It first resorted to theoretical calculation,which demo...This paper investigated the applicability and effects of infrared reflective coating on energy consumption of factory building in hot summer and warm winter zone.It first resorted to theoretical calculation,which demonstrated the beneficial effects of infrared reflective coating on reducing building energy consumption.Then it analyzed a field measurement done on two identical rooms respectively with ordinary coated roof and infrared reflective coated roof from November 2006 to October 2007,on a 24h basis.The measured data include exterior and interior roof surface temperature,indoor air temperature,and indoor globe temperature.The related weather data is from a weather station near the measured area.The continuous measurement has been accomplished in southern China,and the measured data indicate that roof surface temperature and heat gain are significantly decreased in summer while slight negative effects in winter are induced by adopting infrared reflective coating.Thus it is simple and applicable to reduce building energy consumption in this area by applying infrared reflective coating.Regress equation between reduced roof thermal property,such as surface temperature and heat gain,and reduction in absorbed solar radiation shows their highly linear relationship.Based on the measured data,it is estimated that the reduced power consumption is 3.45 kWh/m2·month in June.展开更多
文摘In this paper, the suitability and construction technology of self-insulation walls were studied under the specific climatic conditions and regional resources of Hanzhong and Ankang in the hot summer and cold winter zone of Southern Shaanxi. Through the calculation of heat transfer coefficient and thermal inertia index, combined with the specifications of the shale hollow brick and aerated concrete block of Hanzhong and Ankang in southern Shaanxi, the thermal performance and suitable thickness of the external wall using self-insulation materials that meet the Design Standard for Energy Efficiency of Residential Buildings(DBJ61-65-2011) in Shaanxi Province were obtained. The results showed that the self-insulation wall had technical suitability in the hot summer and cold winter zone. The research results provide not only a theoretical basis for the external wall insulation design of urban residential buildings in the hot summer and cold winter zone of southern Shaanxi, but also a reference for designers to carry out energy-saving design of external walls of residential buildings in other similar climate zones.
文摘This paper investigated the applicability and effects of infrared reflective coating on energy consumption of factory building in hot summer and warm winter zone.It first resorted to theoretical calculation,which demonstrated the beneficial effects of infrared reflective coating on reducing building energy consumption.Then it analyzed a field measurement done on two identical rooms respectively with ordinary coated roof and infrared reflective coated roof from November 2006 to October 2007,on a 24h basis.The measured data include exterior and interior roof surface temperature,indoor air temperature,and indoor globe temperature.The related weather data is from a weather station near the measured area.The continuous measurement has been accomplished in southern China,and the measured data indicate that roof surface temperature and heat gain are significantly decreased in summer while slight negative effects in winter are induced by adopting infrared reflective coating.Thus it is simple and applicable to reduce building energy consumption in this area by applying infrared reflective coating.Regress equation between reduced roof thermal property,such as surface temperature and heat gain,and reduction in absorbed solar radiation shows their highly linear relationship.Based on the measured data,it is estimated that the reduced power consumption is 3.45 kWh/m2·month in June.