As for the present situation of coronal mass ejection (CME) triggering models, the distributions of Alfv@n waves in flux ropes are different from model to model, and thus examining those distributions in interplanet...As for the present situation of coronal mass ejection (CME) triggering models, the distributions of Alfv@n waves in flux ropes are different from model to model, and thus examining those distributions in interplanetary coronal mass ejection (ICME) is an effective way to connect ICME observations with these theoretical models of CME triggering. However, previous observations of Alfv@nic fluctuations in ICMEs were rare with locations ranging from 0.3 AU to 0.68 AU only, which is usually explained as rapid dissipation of those remnant waves. Here we present an observation of Alfv@n waves in a magnetic cloud (MC) near 1 AU, in situ detected by WIND in February 17,-~20, 2011. The MC was generated by a CME accompanied with the first X-class flare in the 24th solar cycle. The slope of the power spectral densities of magnetic fluctuation in the MC, are similar to those modes in ambient solar wind, but more anisotropic. The results will also be helpful for studies of CME theories and ICME thermodynamics.展开更多
Plasma source performance parameters, including plasma ejection density and velocity, greatly affect the operation of a short-conduction-time plasma opening switch (POS). In this paper, the plasma source used in the...Plasma source performance parameters, including plasma ejection density and velocity, greatly affect the operation of a short-conduction-time plasma opening switch (POS). In this paper, the plasma source used in the POS of Qiangguang I generator is chosen as the study object. At first the POS working process is analyzed. The result shows that the opening performance of the POS can be improved by increasing the plasma ejection velocity and decreasing the plasma density. The influence of the cable plasma gun structure and number on the plasma ejection parameters is experimentally investigated with two charge collectors. Finally a semi-empirical model is proposed to describe the experimental phenomenon.展开更多
为满足更长间隙距离、更高电压等级气体开关在较低工作系数下的可靠触发,设计了一种基于毛细管放电的大气压等离子体射流喷射装置,即两间隙毛细管等离子体喷射装置(two gap capillary,TGC)。通过引入中间电极将毛细管通道分为触发通道...为满足更长间隙距离、更高电压等级气体开关在较低工作系数下的可靠触发,设计了一种基于毛细管放电的大气压等离子体射流喷射装置,即两间隙毛细管等离子体喷射装置(two gap capillary,TGC)。通过引入中间电极将毛细管通道分为触发通道和主通道,借助触发通道在放电初始时的弱毛细管放电引燃主通道的放电,实现了重复放电。等离子体射流在触发后的169μs时达到了11 cm左右。主通道电弧电阻呈现"U型"分布,电阻值开始时随主通道电弧电流的增长快速减小,最低时不到200 m?,而后随着电流的跌落快速增加。同时,主通道电弧电阻值在电流增长时要高于电流跌落时,这一差异在流过主通道电弧电流较小时十分明显,而后随着电流幅值的增加逐渐减小。由于没有传统放电结构金属丝电爆的过程,电容器所储能量主要释放于喷射装置主通道,主通道电弧能量沉积效率几乎是传统放电结构的2倍,达到了62.7%。喷射装置寿命大概在300次左右,使用扫描电子显微镜(SEM)拍摄触发通道表面,发现喷射装置TGC中间电极的烧蚀和触发通道的碳化是影响TGC寿命的关键因素,对TGC的寿命优化设计还需做进一步的努力。展开更多
基金supported by National Natural Science Foundation of China (Nos.40974104,40731056,and 10975012)Doctoral Fund of Ministry of Education of China (20090001110012)National Key Basic Research Science Foundation of China (2011CB811400,2009GB105004)
文摘As for the present situation of coronal mass ejection (CME) triggering models, the distributions of Alfv@n waves in flux ropes are different from model to model, and thus examining those distributions in interplanetary coronal mass ejection (ICME) is an effective way to connect ICME observations with these theoretical models of CME triggering. However, previous observations of Alfv@nic fluctuations in ICMEs were rare with locations ranging from 0.3 AU to 0.68 AU only, which is usually explained as rapid dissipation of those remnant waves. Here we present an observation of Alfv@n waves in a magnetic cloud (MC) near 1 AU, in situ detected by WIND in February 17,-~20, 2011. The MC was generated by a CME accompanied with the first X-class flare in the 24th solar cycle. The slope of the power spectral densities of magnetic fluctuation in the MC, are similar to those modes in ambient solar wind, but more anisotropic. The results will also be helpful for studies of CME theories and ICME thermodynamics.
文摘Plasma source performance parameters, including plasma ejection density and velocity, greatly affect the operation of a short-conduction-time plasma opening switch (POS). In this paper, the plasma source used in the POS of Qiangguang I generator is chosen as the study object. At first the POS working process is analyzed. The result shows that the opening performance of the POS can be improved by increasing the plasma ejection velocity and decreasing the plasma density. The influence of the cable plasma gun structure and number on the plasma ejection parameters is experimentally investigated with two charge collectors. Finally a semi-empirical model is proposed to describe the experimental phenomenon.
文摘为满足更长间隙距离、更高电压等级气体开关在较低工作系数下的可靠触发,设计了一种基于毛细管放电的大气压等离子体射流喷射装置,即两间隙毛细管等离子体喷射装置(two gap capillary,TGC)。通过引入中间电极将毛细管通道分为触发通道和主通道,借助触发通道在放电初始时的弱毛细管放电引燃主通道的放电,实现了重复放电。等离子体射流在触发后的169μs时达到了11 cm左右。主通道电弧电阻呈现"U型"分布,电阻值开始时随主通道电弧电流的增长快速减小,最低时不到200 m?,而后随着电流的跌落快速增加。同时,主通道电弧电阻值在电流增长时要高于电流跌落时,这一差异在流过主通道电弧电流较小时十分明显,而后随着电流幅值的增加逐渐减小。由于没有传统放电结构金属丝电爆的过程,电容器所储能量主要释放于喷射装置主通道,主通道电弧能量沉积效率几乎是传统放电结构的2倍,达到了62.7%。喷射装置寿命大概在300次左右,使用扫描电子显微镜(SEM)拍摄触发通道表面,发现喷射装置TGC中间电极的烧蚀和触发通道的碳化是影响TGC寿命的关键因素,对TGC的寿命优化设计还需做进一步的努力。