Baosteel developed a digital automatic analysis technique for maceral specification in 2002. This analysis system combines digital image processing, graphics, databases, expert systems, artificial intelligence and oth...Baosteel developed a digital automatic analysis technique for maceral specification in 2002. This analysis system combines digital image processing, graphics, databases, expert systems, artificial intelligence and other advanced technologies. After 6 years of application in coke production, the system proved itself successful in coal quality testing and coal blending guidance on maceral. However,during this long process, some inadequacies were found that impacted the precision and accuracy of the analysis. So ,in 2008 Baosteel began to work on improving the coal maceral analysis system. The improvements included the following:further upgrading and enhancing the analysis performance of microscopic images ;extending the gray levels to increase the reflectance measurement accuracy 64 times;changing the focus method and effectively eliminating the interference of halo. In addition, an improved image recognition method was adopted to make the extraction of vitrinite more accurate and a new model of coal constituent algorithm was added which can accurately determine the composition of maceral (exinite, vitrinite,inertinite). Since these improvements were completed, the system has achieved higher automation, speed and accuracy, collected more information and performed more accurate maceral analysis for coke production. Meanwhile, the improved system has provided a reliable analytical basis for the further study on the relationship between coke quality and coal blending.展开更多
Theoretical minimum and actual specific energy consumptions (SEC) of typical manufacturing process (SMP) were studied. Firstly, a process division of a typical SMP in question was conducted with the theory of SEC ...Theoretical minimum and actual specific energy consumptions (SEC) of typical manufacturing process (SMP) were studied. Firstly, a process division of a typical SMP in question was conducted with the theory of SEC analysis. Secondly, an exergy analysis model of a subsystem consisting of several parallel processes and a SEC analysis model of SMP were developed. And finally, based on the analysis models, the SEC of SMP was analyzed by means of the statistical significance. The results show that the SEC of typical SMP comprises the theoretical minimum SEC and the additional SEC derived from the irreversibility~ and the SMP has a theoretical minimum SEC of 6.74 GJ/t and an additional SEC of 19.32 GJ/t, which account for 25.88% and 74.12% of the actual SEC, respectively.展开更多
Requirements analysis is an important phase in a software project. The analysis is often performed in an informal way by specialists who review documents looking for ambiguities, technical inconsistencies and incomple...Requirements analysis is an important phase in a software project. The analysis is often performed in an informal way by specialists who review documents looking for ambiguities, technical inconsistencies and incomplete parts. Automation is still far from being applied in requirements analyses, above all since natural languages are informal and thus difficult to treat automatically. There are only a few tools that can analyse texts. One of them, called QuARS, was developed by the Istituto di Scienza e Tecnologie dell'Informazione and can analyse texts in terms of ambiguity. This paper describes how QuARS was used in a formal empirical experiment to assess the impact in terms of effectiveness and efficacy of the automation in the requirements review process of a software company.展开更多
The aim of this work is to describe and compare three exploratory chemometrical tools,principal components analysis,independent components analysis and common components analysis,the last one being a modification of t...The aim of this work is to describe and compare three exploratory chemometrical tools,principal components analysis,independent components analysis and common components analysis,the last one being a modification of the multi-block statistical method known as common components and specific weights analysis.The three methods were applied to a set of data to show the differences and similarities of the results obtained,highlighting their complementarity.展开更多
文摘Baosteel developed a digital automatic analysis technique for maceral specification in 2002. This analysis system combines digital image processing, graphics, databases, expert systems, artificial intelligence and other advanced technologies. After 6 years of application in coke production, the system proved itself successful in coal quality testing and coal blending guidance on maceral. However,during this long process, some inadequacies were found that impacted the precision and accuracy of the analysis. So ,in 2008 Baosteel began to work on improving the coal maceral analysis system. The improvements included the following:further upgrading and enhancing the analysis performance of microscopic images ;extending the gray levels to increase the reflectance measurement accuracy 64 times;changing the focus method and effectively eliminating the interference of halo. In addition, an improved image recognition method was adopted to make the extraction of vitrinite more accurate and a new model of coal constituent algorithm was added which can accurately determine the composition of maceral (exinite, vitrinite,inertinite). Since these improvements were completed, the system has achieved higher automation, speed and accuracy, collected more information and performed more accurate maceral analysis for coke production. Meanwhile, the improved system has provided a reliable analytical basis for the further study on the relationship between coke quality and coal blending.
基金Item Sponsored by Fundamental Research Funds for the Central Universities of China(N090602007)National Key Technology Research and Development Program in 11th Five-Year Plan Project of China(2006BAE03A09)
文摘Theoretical minimum and actual specific energy consumptions (SEC) of typical manufacturing process (SMP) were studied. Firstly, a process division of a typical SMP in question was conducted with the theory of SEC analysis. Secondly, an exergy analysis model of a subsystem consisting of several parallel processes and a SEC analysis model of SMP were developed. And finally, based on the analysis models, the SEC of SMP was analyzed by means of the statistical significance. The results show that the SEC of typical SMP comprises the theoretical minimum SEC and the additional SEC derived from the irreversibility~ and the SMP has a theoretical minimum SEC of 6.74 GJ/t and an additional SEC of 19.32 GJ/t, which account for 25.88% and 74.12% of the actual SEC, respectively.
文摘Requirements analysis is an important phase in a software project. The analysis is often performed in an informal way by specialists who review documents looking for ambiguities, technical inconsistencies and incomplete parts. Automation is still far from being applied in requirements analyses, above all since natural languages are informal and thus difficult to treat automatically. There are only a few tools that can analyse texts. One of them, called QuARS, was developed by the Istituto di Scienza e Tecnologie dell'Informazione and can analyse texts in terms of ambiguity. This paper describes how QuARS was used in a formal empirical experiment to assess the impact in terms of effectiveness and efficacy of the automation in the requirements review process of a software company.
文摘The aim of this work is to describe and compare three exploratory chemometrical tools,principal components analysis,independent components analysis and common components analysis,the last one being a modification of the multi-block statistical method known as common components and specific weights analysis.The three methods were applied to a set of data to show the differences and similarities of the results obtained,highlighting their complementarity.