期刊文献+
共找到228篇文章
< 1 2 12 >
每页显示 20 50 100
Laser speckle contrast imaging to predict the effect of temporary spinal cord stimulation in postherpetic neuralgia patients: A prospective observational study
1
作者 Xiang Huang Dacheng Tang +3 位作者 Pan Chen Lumiao Chen Xiaohong Li Xiaoping Wang 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第1期69-75,共7页
Temporary spinal cord stimulation(tSCS)can effectively reduce the pain and severity of postherpetic neuralgia(PHN).However,there are no effective and objective methods for predicting the effects of tSCS on PHN.Laser s... Temporary spinal cord stimulation(tSCS)can effectively reduce the pain and severity of postherpetic neuralgia(PHN).However,there are no effective and objective methods for predicting the effects of tSCS on PHN.Laser speckle contrast imaging(LSCI)is frequently used in neurology to evaluate the effectiveness of treatment.To assess the accuracy of LSCI in predicting the impact of tSCS on PHN,14 adult patients receiving tSCS treatments for spinal nerve-innervated(C6-T2)PHN participated in this observational study.Visual analog scale(VAS)assessments and LSCI bloodflow images of the-ngers were recorded after the tSCS procedure.The results showed that the VAS scores of all patients decreased signi-cantly.Moreover,the bloodflow index(BFI)values were signi-cantly higher than they were before the procedure.Increased bloodflow and pain alleviation were positively correlated.The-ndings indicated that spinal nerve PHN(C6-T2)was signi-cantly reduced by tSCS.Pain alleviation by tSCS was positively correlated with increased bloodflow in the hand.The effect of tSCS on PHN may thus be predicted using an independent and consistent indicator such as LSCI. 展开更多
关键词 Laser speckle contrast imaging temporary spinal cord stimulation postherpetic neuralgia
下载PDF
Application of three-dimensional speckle tracking technique in measuring left ventricular myocardial function in patients with diabetes
2
作者 Zheng Li Ying Qian +1 位作者 Chun-Yun Fan Yong Huang 《World Journal of Diabetes》 SCIE 2024年第4期783-792,共10页
BACKGROUND Diabetic cardiomyopathy is considered as a chronic complication of diabetes mellitus(DM).Therefore,early detection of left ventricular systolic function(LVSF)damage in DM is essential.AIM To explore the use... BACKGROUND Diabetic cardiomyopathy is considered as a chronic complication of diabetes mellitus(DM).Therefore,early detection of left ventricular systolic function(LVSF)damage in DM is essential.AIM To explore the use of the three-dimensional speckle tracking technique(3D-STI)for measuring LVSF in DM patients via meta-analysis.METHODS The electronic databases were retrieved from the initial accessible time to 29 April 2023.The current study involved 9 studies,including 970 subjects.We carried out this meta-analysis to estimate myocardial function in DM compared with controls according to myocardial strain attained by 3D-STI.RESULTS Night articles including 970 subjects were included.No significant difference was detected in the left ventricular ejection fraction between the control and the diabetic group(P>0.05),while differences in global longitudinal strain,global circumferential strain,global radial strain,and global area strain were markedly different between the controls and DM patients(all P<0.05).CONCLUSION The 3D-STI could be applied to accurately measure early LVSF damage in patients with DM. 展开更多
关键词 Diabetes mellitus Left ventricular systolic dysfunction Three-dimensional speckle tracking echocardiography Meta analysis
下载PDF
A speckle noise suppression method based on surface waves investigation and monitoring data
3
作者 Jingwei Gu Xiuzhong Li Yijun He 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2023年第1期131-141,共11页
The internal energy distribution of waves can be described using ocean-wave spectra.In many ways,obtaining wave spectra on a global scale is critical.Surface waves investigation and monitoring onboard the Chinese-Fren... The internal energy distribution of waves can be described using ocean-wave spectra.In many ways,obtaining wave spectra on a global scale is critical.Surface waves investigation and monitoring onboard the Chinese-French oceanography satellite is the first space-borne instrument for detecting wave spectra specially,which was launched on October 29,2018.It can avoid the shortage of synthetic aperture radar detection results while still having some problems,especially with the effects of speckle noise.In this study,a method to suppress the speckle noise is proposed.First,the empirical formula for background speckle noise is established.Second,many spatio-temporal representative fluctuation spectra are classified and averaged.Third,rational transfer function filtering is used to obtain speckle noise close to the along-track direction.Finally,a signal-to-noise ratio threshold is used to suppress the abnormal speckle noise.This method solves the problems existing in previous denoising methods,such as excessive denoising in the along-track direction and the inability of some abnormal noises to be denoised in the two-dimensional directional wave spectra. 展开更多
关键词 speckle noise surface waves investigation and monitoring WaveWatch III wave spectra
下载PDF
High performance“non-local”generic face reconstruction model using the lightweight Speckle-Transformer(SpT)UNet
4
作者 Yangyundou Wang Hao Wang Min Gu 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2023年第2期1-9,共9页
Significant progress has been made in computational imaging(CI),in which deep convolutional neural networks(CNNs)have demonstrated that sparse speckle patterns can be reconstructed.However,due to the limited“local”k... Significant progress has been made in computational imaging(CI),in which deep convolutional neural networks(CNNs)have demonstrated that sparse speckle patterns can be reconstructed.However,due to the limited“local”kernel size of the convolutional operator,for the spatially dense patterns,such as the generic face images,the performance of CNNs is limited.Here,we propose a“non-local”model,termed the Speckle-Transformer(SpT)UNet,for speckle feature extraction of generic face images.It is worth noting that the lightweight SpT UNet reveals a high efficiency and strong comparative performance with Pearson Correlation Coefficient(PCC),and structural similarity measure(SSIM)exceeding 0.989,and 0.950,respectively. 展开更多
关键词 speckle reconstruction non-local model generic face images lightweight network
下载PDF
Transmissive multifocal laser speckle contrast imaging through thick tissue
5
作者 Ruoyu Chen Peng Miao Shanbao Tong 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2023年第5期129-138,共10页
Laser speckle contrast imaging(LSCI)is a powerful tool for monitoring blood flow changes in tissue or vessels in vivo,but its applications are limited by shallow penetration depth under reflective imaging configuratio... Laser speckle contrast imaging(LSCI)is a powerful tool for monitoring blood flow changes in tissue or vessels in vivo,but its applications are limited by shallow penetration depth under reflective imaging configuration.The traditional LSCI setup has been used in transmissive imaging for depth extension up to 2l_(t)–3l_(t)(l_(t)is the transport mean free path),but the blood flow estimation is biased due to the depth uncertainty in large depth of field(DOF)images.In this study,we propose a transmissive multifocal LSCI for depth-resolved blood flow in thick tissue,further extending the transmissive LSCI for tissue thickness up to 12lt.The limited-DOF imaging system is applied to the multifocal acquisition,and the depth of the vessel is estimated using a robust visibility parameter V_(r)in the coherent domain.The accuracy and linearity of depth estimation are tested by Monte Carlo simulations.Based on the proposed method,the model of contrast analysis resolving the depth information is established and verified in a phantom experiment.We demonstrated its effectiveness in acquiring depth-resolved vessel structures and flow dynamics in in vivo imaging of chick embryos. 展开更多
关键词 Transmissive imaging multifocal imaging DEPTH laser speckle contrast model.
下载PDF
Speckle structured illumination endoscopy with enhanced resolution at wide field of view and depth of field
6
作者 Elizabeth Abraham Junxiao Zhou Zhaowei Liu 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2023年第7期10-17,共8页
Structured illumination microscopy(SIM)is one of the most widely applied wide field super resolution imaging techniques with high temporal resolution and low phototoxicity.The spatial resolution of SIM is typically li... Structured illumination microscopy(SIM)is one of the most widely applied wide field super resolution imaging techniques with high temporal resolution and low phototoxicity.The spatial resolution of SIM is typically limited to two times of the diffraction limit and the depth of field is small.In this work,we propose and experimentally demonstrate a low cost,easy to implement,novel technique called speckle structured illumination endoscopy(SSIE)to enhance the resolution of a wide field endoscope with large depth of field.Here,speckle patterns are used to excite objects on the sample which is then followed by a blind-SIM algorithm for super resolution image reconstruction.Our approach is insensitive to the 3D morphology of the specimen,or the deformation of illuminations used.It greatly simplifies the experimental setup as there are no calibration protocols and no stringent control of illumination patterns nor focusing optics.We demonstrate that the SSIE can enhance the resolution 2–4.5 times that of a standard white light endoscopic(WLE)system.The SSIE presents a unique route to super resolution in endoscopic imaging at wide field of view and depth of field,which might be beneficial to the practice of clinical endoscopy. 展开更多
关键词 speckle structured illumination endoscopy wide field of view large depth of field easy-to-implement low cost
下载PDF
Generation of high intensity speckles in overlapping laser beams
7
作者 Liang Hao Jie Qiu Wen Yi Huo 《Matter and Radiation at Extremes》 SCIE EI CAS CSCD 2023年第2期56-66,共11页
A new mechanism for the generation of high intensity speckles by coupling of overlapping beams is discovered and studied in detail.Using three-dimensional simulations,the coupling of overlapping beams smoothed by phas... A new mechanism for the generation of high intensity speckles by coupling of overlapping beams is discovered and studied in detail.Using three-dimensional simulations,the coupling of overlapping beams smoothed by phase plates and by polarization smoothing are investigated in the regime relevant to inertial confinement fusion studies.It is found that the intensity distribution of the laser beam spot can be changed by nonuniform spatial phase modulation,and the speckles formed by the phase plate can be split into smaller speckles with higher intensities,which is favorable for the generation of laser plasma instabilities.Stimulated Brillouin scattering is compared in simulations with and without coupling of the overlapping incident beams,and the results confirm the enhancement of stimulated Brillouin scattering due to this mechanism. 展开更多
关键词 SCATTERING POLARIZATION speckle
下载PDF
Speckle Noise Suppression in Ultrasound Images Using Modular Neural Networks
8
作者 G.Karthiha Dr.S.Allwin 《Intelligent Automation & Soft Computing》 SCIE 2023年第2期1753-1765,共13页
In spite of the advancement in computerized imaging,many image modalities produce images with commotion influencing both the visual quality and upsetting quantitative image analysis.In this way,the research in the zone... In spite of the advancement in computerized imaging,many image modalities produce images with commotion influencing both the visual quality and upsetting quantitative image analysis.In this way,the research in the zone of image denoising is very dynamic.Among an extraordinary assortment of image restoration and denoising techniques the neural network system-based noise sup-pression is a basic and productive methodology.In this paper,Bilateral Filter(BF)based Modular Neural Networks(MNN)has been utilized for speckle noise sup-pression in the ultrasound image.Initial step the BFfilter is used tofilter the input image.From the output of BF,statistical features such as mean,standard devia-tion,median and kurtosis have been extracted and these features are used to train the MNN.Then,thefiltered images from the BF are again denoised using MNN.The ultrasound dataset from the Kaggle site is used for the training and testing process.The simulation outcomes demonstrate that the BF-MNNfiltering method performs better for the multiplicative noise concealment in UltraSound(US)images.From the simulation results,it has been observed that BF-MNN performs better than the existing techniques in terms of peak signal to noise ratio(34.89),Structural Similarity Index(0.89)and Edge Preservation Index(0.67). 展开更多
关键词 speckle noise bilateralfilter ultra-sound image MNN KURTOSIS
下载PDF
In-flight deformation measurement for high-aspect-ratio wing based on 3D speckle correlation
9
作者 张兴国 HU Binghua +3 位作者 WANG Yuanliang YAN Hui MA Xiaodong GE Quanbo 《High Technology Letters》 EI CAS 2023年第3期257-268,共12页
In order to get an effective solution of the in-flight wing deformation measurement for high-wing aircrafts with high-aspect-ratio,a method based on three-dimensional(3D)speckle correlation technique is proposed.First... In order to get an effective solution of the in-flight wing deformation measurement for high-wing aircrafts with high-aspect-ratio,a method based on three-dimensional(3D)speckle correlation technique is proposed.Firstly,an in-flight wing deformation measurement system with two sets of conjugate cameras is designed based on structural characteristics and test requirements of high-wing aircrafts with large-aspect-ratio.Secondly,the in-flight wing deformation measurement method based on 3D speckle correlation technique is introduced including three aspects:measuring system and wing datum calibration,speckle image matching and 3D reconstruction,and wing deformation analysis.Fi-nally,ground simulation test of dynamic deformation measurement of a scaled model wing and flight test of dynamic deformation measurement of a large transport wing are carried out.The test results show that the measuring accuracy of single point coordinate in ground simulation test is better than 0.1 mm/m,in the airborne vibration environment,the static single-point positioning accuracy is bet-ter than 5 mm,and the in-flight wing deformation measurement data is well received by the flight test engineers.This method can satisfy the requirements of stability,reliability,high precision,non-con-tact and full-field measurement for dynamic deformation measurement of aircraft wing with high-as-pect-ratio. 展开更多
关键词 HIGH-ASPECT-RATIO three-dimensional(3D)speckle wing datum
下载PDF
Numerical model for evaluating the speckle activity and characteristics of bone tissue under the biospeckle laser system
10
作者 Xin Tang Ping Zhong +1 位作者 Yinrui Gao Haowei Hu 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2021年第6期102-118,共17页
This paper discusses and studies the composition and characteristics of biospeckle on the surface of bone tissues.We used a laser speckle device to capture biospeckle patterns from fresh pig bone tissue.Traditional sp... This paper discusses and studies the composition and characteristics of biospeckle on the surface of bone tissues.We used a laser speckle device to capture biospeckle patterns from fresh pig bone tissue.Traditional speckle activity metrics were used to measure the speckle activity of ex vivo bone tissue over time.Both Gaussian and Lorentzian correlation functions were used to char-acterize the ordered and disordered motion of the bone surface,together with volume scattering,to construct the model.Using the established mathematical model of the spatio-temporal evo-lution of the biospeckle pattern,it is possible to account for the presence of volume scattering from the biospeckle of bones,quantify the ordered or disordered motions in the biological speckle activity at the current time,and assess the ability of laser speckle correlation technique to determine biological activity. 展开更多
关键词 speckle metrology biospeckle speckle correlation computer simulation osteogenic activity biomedical optics
下载PDF
海洋SAR图像小波Speckle滤波及边缘信息提取 被引量:10
11
作者 郭子祺 卢刚 +1 位作者 王超 潘广东 《遥感学报》 EI CSCD 北大核心 2001年第6期428-433,T002,共7页
以海洋SAR图像的speckle滤波和边缘信息提取为研究目标 ,构造了以低通带通窄和时域冲击响应系数分布呈左右对称为特征的小波滤波器。这些特征使该小波滤波器在处理突变信号方面具有优良的特性。应用该小波滤波器 ,采用Wiener滤波算法 ,... 以海洋SAR图像的speckle滤波和边缘信息提取为研究目标 ,构造了以低通带通窄和时域冲击响应系数分布呈左右对称为特征的小波滤波器。这些特征使该小波滤波器在处理突变信号方面具有优良的特性。应用该小波滤波器 ,采用Wiener滤波算法 ,对海洋SAR图像进行了speckle滤波及采用Prewitt算子对边缘信息进行提取。用几种经典小波基函数采用相同的滤波算法和边缘增强算子进行了处理 ,并将它们的结果进行了对比分析。结果表明 ,虽然小波基函数在用于speckle滤波方面 ,稍逊其它几种经典小波基函数 ,但是在边缘信息保留方面 ,效果要明显优于其他小波基函数。 展开更多
关键词 SAR图像 speckle滤波 边缘提取 海洋 小波滤波器 噪斑信号 突变信号
下载PDF
小波软阈值算法去除SAR图像中的Speckle噪声 被引量:11
12
作者 池明旻 卢刚 +1 位作者 黄盛璋 李郁 《厦门大学学报(自然科学版)》 CAS CSCD 北大核心 2002年第6期756-758,共3页
在详细分析了Donoho小波软阈值的基础上 ,应用小波变换技术对SAR图像进行分析处理 .使用“小波局部软阈值算法”来计算阈值 ,对高频小波系数进行阈值确定 .求得估计小波系数 ,对其取小波反变换后 ,去除SAR图像中的Speckle噪声 .实验结... 在详细分析了Donoho小波软阈值的基础上 ,应用小波变换技术对SAR图像进行分析处理 .使用“小波局部软阈值算法”来计算阈值 ,对高频小波系数进行阈值确定 .求得估计小波系数 ,对其取小波反变换后 ,去除SAR图像中的Speckle噪声 .实验结果表明此方法对去除Speckle噪声十分有效 。 展开更多
关键词 小波软阈值算法 SAR图像 speckle噪声 小波变换 图像去噪 边缘检测 合成孔径雷达
下载PDF
一种基于相对标准差的SAR图像Speckle滤波方法 被引量:13
13
作者 徐新 廖明生 卜方玲 《遥感学报》 EI CSCD 2000年第3期214-218,共5页
通过分析SAR影像的Speckle局部统计特性和现有的空间滤波算法 ,提出了一种新的Speckle滤波方法 ,该方法以局部相对标准差为主要依据 ,采用特殊的滤波窗口邻域划分方法 ,自适应地调整窗口尺寸和窗口内的滤波区域。该方法被用于多幅ERS 1/... 通过分析SAR影像的Speckle局部统计特性和现有的空间滤波算法 ,提出了一种新的Speckle滤波方法 ,该方法以局部相对标准差为主要依据 ,采用特殊的滤波窗口邻域划分方法 ,自适应地调整窗口尺寸和窗口内的滤波区域。该方法被用于多幅ERS 1/ 2SAR图像去Speckle处理 ,并与以往的典型算法进行了比较实验 ,取得了令人满意的结果。 展开更多
关键词 相对标准差 遥感图像 SAR图像 speckle滤波
下载PDF
基于非线性加权均值的多方向广义形态滤波算法的Speckle噪声抑制 被引量:1
14
作者 蒋立辉 赵春晖 王骐 《信号处理》 CSCD 2003年第2期145-148,共4页
本文提出了一种新的用于散斑噪声抑制的非线性加权均值多方向广义形态滤波算法。对实际激光雷达图像处理结果表明:本文算法具备了小波阈值算法图像边缘保持好和局部统计滤波算法散斑噪声抑制能力强的优点,在算法复杂度降低的前提下具有... 本文提出了一种新的用于散斑噪声抑制的非线性加权均值多方向广义形态滤波算法。对实际激光雷达图像处理结果表明:本文算法具备了小波阈值算法图像边缘保持好和局部统计滤波算法散斑噪声抑制能力强的优点,在算法复杂度降低的前提下具有了与F.Safa的改进算法(广义并行加权多方向形态滤波算法)相当的效果,即有效地抑制了散斑噪声,又保持了图像的几何结构。 展开更多
关键词 激光雷达 非线性加权均值 多方向广义形态滤波算法 speckle噪声抑制 图像处理
下载PDF
基于CxImage库的SAR图像Speckle噪声抑制 被引量:1
15
作者 陈海花 张亮 陈鹏 《电子科技》 2013年第7期54-58,共5页
合成孔径雷达图像的相干斑噪声抑制是SAR信息处理中的一个重要环节。经典的Speckle噪声抑制通常作为一个处理模块集成在软件中,但现有软件代码封装无法二次开发。针对文中提出了一种基于开源图像库CxImage的空间域自适应Speckle噪声抑... 合成孔径雷达图像的相干斑噪声抑制是SAR信息处理中的一个重要环节。经典的Speckle噪声抑制通常作为一个处理模块集成在软件中,但现有软件代码封装无法二次开发。针对文中提出了一种基于开源图像库CxImage的空间域自适应Speckle噪声抑制算法的应用与集成。将CxImage图像库链接入MFC应用程序框架中,利用其图像管理、维护、处理功能对SAR图像进行维护管理,集成多种经典的空间域自适应滤波方法,并以ERS-2卫星的PRISAR数据为例,进行Speckle噪声滤波处理,选取适当的滤波效果评价参数,对滤波结果进行比较,最终得出各滤波算法应用于SAR图像滤波的优劣。 展开更多
关键词 遥感信息处理 SAR speckle噪声 Cximage库
下载PDF
Laser speckle contrast imaging for monitoring of acutepancreatitis at ischemia-reperfusion injury of thepancreas in rats 被引量:4
16
作者 P.A.Dyachenko(Timoshina) A.N.Bashkatov +2 位作者 D.A.Alexandrov V.I.Kochubey V.V.Tuchin 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2022年第1期90-102,共13页
The influence of ischemia-reperfusion(I/R)action on pancreatic blood flow(PBF)and the development of acute pancreatitis(AP)in laboratory rats is evaluated in vivo by using the laser speckle contrast imaging(LSCI).Addi... The influence of ischemia-reperfusion(I/R)action on pancreatic blood flow(PBF)and the development of acute pancreatitis(AP)in laboratory rats is evaluated in vivo by using the laser speckle contrast imaging(LSCI).Additionally,the optical properties in norm and under condition of AP in rats were assessed using a modied integrating sphere spectrometer and inverse Monte Carlo(IMC)software.The results of the experimental study of microcirculation of the pancreas in 82 rats in the ischemic model are presented.The data obtained conrm the fact that local ischemia and changes in the blood°ow velocity of the main vessels cause and provoke acute pancreatitis. 展开更多
关键词 Laser speckles contrast of speckle images adaptive algorithm MICROCIRCULATION blood flow acute pancreatitis PANCREAS RATS optical properties integrating sphere spectroscopy
下载PDF
Speckle噪声滤波算法的研究与设计
17
作者 景慧丽 杨宝珍 +1 位作者 赵伟舟 刘华 《西北师范大学学报(自然科学版)》 CAS 北大核心 2013年第5期51-53,69,共4页
针对Speckle噪声的复杂性和真值图像的不可知性,结合奇异值分解和曲面拟合进行了消噪算法的研究与设计.首先对局部图像的奇异值分解结果采用中值滤波进行消噪,其次引入参数修正过程以替代传统的阈值处理方法,最后利用曲面拟合技术恢复... 针对Speckle噪声的复杂性和真值图像的不可知性,结合奇异值分解和曲面拟合进行了消噪算法的研究与设计.首先对局部图像的奇异值分解结果采用中值滤波进行消噪,其次引入参数修正过程以替代传统的阈值处理方法,最后利用曲面拟合技术恢复局部图像并获得消噪结果.实验表明,与传统的滤波方法相比,从定性和定量方面进行分析,文中算法对Speckle噪声获得了较为满意的结果. 展开更多
关键词 speckle噪声 奇异值分解 曲面拟合
下载PDF
基于奇异值分解的Speckle噪声滤波算法研究
18
作者 赵伟舟 杨宝珍 景慧丽 《电视技术》 北大核心 2013年第23期12-14,26,共4页
Speckle噪声的复杂性和真值图像的不可知性增加了消噪算法设计的难度,传统算法在设计时借助污染像素估计灰度真值,同时忽略了位置信息对灰度估计的影响。借助奇异值分解和曲面拟合进行了消噪算法的研究与设计,首先在局部窗口进行奇异值... Speckle噪声的复杂性和真值图像的不可知性增加了消噪算法设计的难度,传统算法在设计时借助污染像素估计灰度真值,同时忽略了位置信息对灰度估计的影响。借助奇异值分解和曲面拟合进行了消噪算法的研究与设计,首先在局部窗口进行奇异值分解,并对酉矩阵采用中值滤波进行消噪,其次引入参数修正奇异值以替代传统的阈值处理方法,最后在局部区域利用灰度曲面拟合技术重构消噪图像。实验表明,与传统的均值滤波、中值滤波相比,该算法能获得较为满意的消噪结果,具有较高的峰值信噪比和边缘保留指数。 展开更多
关键词 speckle噪声 奇异值分解 曲面拟合 峰值信噪比 边缘保留指数
下载PDF
一种基于模糊神经网络的Speckle图像滤波器
19
作者 刘忠仁 孙圣和 《遥测遥控》 2003年第6期35-38,65,共5页
提出一种新的基于模糊神经网络 (FNN)的 Speckle噪声自适应滤波器 ,以实时处理 SAR图像。讨论了模糊神经网络滤波器结构的设计、模糊规则的选取以及采用改进遗传算法进行参数优化的方法 ,最后 ,结合图像处理应用实例 ,与其它传统图像滤... 提出一种新的基于模糊神经网络 (FNN)的 Speckle噪声自适应滤波器 ,以实时处理 SAR图像。讨论了模糊神经网络滤波器结构的设计、模糊规则的选取以及采用改进遗传算法进行参数优化的方法 ,最后 ,结合图像处理应用实例 ,与其它传统图像滤波器进行比较 ,验证所述滤波器在滤除噪声和保持细节纹理方面的有效性。 展开更多
关键词 图像滤波 模糊神经网络 模糊系统 SAR speckle噪声
下载PDF
Ultrasound Speckle Reduction Based on Histogram Curve Matching and Region Growing
20
作者 Jinrong Hu Zhiqin Lei +2 位作者 Xiaoying Li Yongqun He Jiliu Zhou 《Computers, Materials & Continua》 SCIE EI 2020年第10期705-722,共18页
The quality of ultrasound scanning images is usually damaged by speckle noise.This paper proposes a method based on local statistics extracted from a histogram to reduce ultrasound speckle through a region growing alg... The quality of ultrasound scanning images is usually damaged by speckle noise.This paper proposes a method based on local statistics extracted from a histogram to reduce ultrasound speckle through a region growing algorithm.Unlike single statistical moment-based speckle reduction algorithms,this method adaptively smooths the speckle regions while preserving the margin and tissue structure to achieve high detectability.The criterion of a speckle region is defined by the similarity value obtained by matching the histogram of the current processing window and the reference window derived from the speckle region in advance.Then,according to the similarity value and tissue characteristics,the entire image is divided into several levels of speckle-content regions,and adaptive smoothing is performed based on these classification characteristics and the corresponding window size determined by the proposed region growing technique.Tests conducted from phantoms and in vivo images have shown very promising results after a quantitative and qualitative comparison with existing work. 展开更多
关键词 Ultrasound speckle histogram matching speckle reduction tissue characterization region growing
下载PDF
上一页 1 2 12 下一页 到第