Real-time monitoring of nitrogen status in rice and wheat plant is of significant importance for nitrogen diagnosis, fertilization recommendation, and productivity prediction. With 11 field experiments involving diffe...Real-time monitoring of nitrogen status in rice and wheat plant is of significant importance for nitrogen diagnosis, fertilization recommendation, and productivity prediction. With 11 field experiments involving different cultivars, nitrogen rates, and water regimes, time-course measurements were taken of canopy hyperspeetral reflectance between 350-2 500 nm and leaf nitrogen accumulation (LNA) in rice and wheat. A new spectral analysis method through the consideration of characteristics of canopy components and plant growth status varied with phenological growth stages was designed to explore the common central bands in rice and wheat. Comprehensive analyses were made on the quantitative relationships of LNA to soil adjusted vegetation index (SAVI) and ratio vegetation index (RVI) composed of any two bands between 350-2 500 nm in rice and wheat. The results showed that the ranges of indicative spectral reflectance were largely located in 770-913 and 729-742 nm in both rice and wheat. The optimum spectral vegetation index for estimating LNA was SAVI (R822, R738) during the early-mid period (from jointing to booting), and it was RVI (Rs22, R73s) during the mid-late period (from heading to filling) with the common central bands of 822 and 738 nm in rice and wheat. Comparison of the present spectral vegetation indices with previously reported vegetation indices gave a satisfactory performance in estimating LNA. It is concluded that the spectral bands of 822 and 738 nm can be used as common reflectance indicators for monitoring leaf nitrogen accumulation in rice and wheat.展开更多
We analyzed the infrared 0R)-near infrared (NIR) 2D correlation spectra of drugs perturbed by temperature. By identification of functional groups by IR spectrum and by the correlation analysis of IR-NIR spectrum, w...We analyzed the infrared 0R)-near infrared (NIR) 2D correlation spectra of drugs perturbed by temperature. By identification of functional groups by IR spectrum and by the correlation analysis of IR-NIR spectrum, we identified the characteristic spectral bands that were closely related to the structure of a drug substance of interest. These characteristic spectral bands were relatively less interfered by other ingredients for analysis by the NIR correlation coefficient method. With these characteristic spectral bands, the accuracy of screening illegally added Sildenafil citrate, Tadalafil and Metforrnin hydrochloride in Chinese patent drugs and healthcare products reached about 90%, which met the requirements of rapid screening.展开更多
The visible infrared radiometer(VIRR)is the first instrument with longest measurements equipped on the Fengyun(FY)polar-orbiting satellites.Through re-processing of the historic VIRR measurements,long-term(over 20 yr)...The visible infrared radiometer(VIRR)is the first instrument with longest measurements equipped on the Fengyun(FY)polar-orbiting satellites.Through re-processing of the historic VIRR measurements,long-term(over 20 yr)global data can be integrated from multiple participating VIRRs on a consistent radiometric scale,which are valuable to climate and climate change studies.Due to lack of an onboard calibration system for VIRR,the reflective solar bands must be vicariously calibrated.This study applied the multi-site vicarious approach for consistent calibration of the VIRR visible(VIS)and near-infrared(NIR)data,and produced calibration coefficients for five VIRRs on FY-1 C/D and FY-3 A/B/C.The data quality was then evaluated with observations.The reflectance predicted by using the radiative transfer model over multiple invariant desert and ocean targets was used to derive the calibration slope via a weighted fitting scheme,in which the weights are the inverse of the variance from a radiative transfer simulation evaluated with reference to Aqua moderate resolution imaging spectroradiometer(MODIS).The sensor-specific calibration coefficients were derived on a daily basis by using piecewise polynomials.The calibration reference of the VIRR solar band record was further traced to the Aqua MODIS Collection 6.1 reference calibration with a systematic correction derived from the Libya4 desert.The VIRR record was compared with the Aqua MODIS C6.1 calibration over the polar region based on simultaneous nadir overpass observations.The lifetime relative difference for each sensor are within 3.3%and 4.5%for channels 1 and 2.Invariant deserts were also employed to evaluate the stability and consistency of the VIRR record.In general,the means of the directional and spectral corrected reflectance for each sensor are within 1%of the 20-yr average,implying that the VIRR reflectance of the invariant targets is consistent to within 1%among the sensors for channels 1 and 2.The VIRR data thus derived are reliable.展开更多
On the basis of a wide range survey of various models or treatment methods for the calculation of radiative properties of gases, box model, which is similar to the gray band approximation of spectral band model, was a...On the basis of a wide range survey of various models or treatment methods for the calculation of radiative properties of gases, box model, which is similar to the gray band approximation of spectral band model, was applied to evaluate the gas properties in this paper. In order to compare the accuracy of box model with that of gray band approximation of spectral band models, a typical one-dimensional gas radiation problem was analyzed using discrete ordinate method. Comparing with the widely used gray band approximation of narrow band model or exponential wide band model, box model can well evaluate the radiation source term of the radiative problem. It also has the advantages of simplicity and easy to code, so it is practicable and useful for some complex engineering problems.展开更多
基金supported by the National High-Tech R&D Program of China(2011AA100703)the National Natural Science Foundation of China(30900868)+2 种基金the Natural Science Foundation of Jiangsu Province, China(BK2010453)the Academic Program Development of Jiangsu Higher Education Institutions, China(PAPD)the Science and Technology Support Plan of Jiangsu Province, China(BE2011351)
文摘Real-time monitoring of nitrogen status in rice and wheat plant is of significant importance for nitrogen diagnosis, fertilization recommendation, and productivity prediction. With 11 field experiments involving different cultivars, nitrogen rates, and water regimes, time-course measurements were taken of canopy hyperspeetral reflectance between 350-2 500 nm and leaf nitrogen accumulation (LNA) in rice and wheat. A new spectral analysis method through the consideration of characteristics of canopy components and plant growth status varied with phenological growth stages was designed to explore the common central bands in rice and wheat. Comprehensive analyses were made on the quantitative relationships of LNA to soil adjusted vegetation index (SAVI) and ratio vegetation index (RVI) composed of any two bands between 350-2 500 nm in rice and wheat. The results showed that the ranges of indicative spectral reflectance were largely located in 770-913 and 729-742 nm in both rice and wheat. The optimum spectral vegetation index for estimating LNA was SAVI (R822, R738) during the early-mid period (from jointing to booting), and it was RVI (Rs22, R73s) during the mid-late period (from heading to filling) with the common central bands of 822 and 738 nm in rice and wheat. Comparison of the present spectral vegetation indices with previously reported vegetation indices gave a satisfactory performance in estimating LNA. It is concluded that the spectral bands of 822 and 738 nm can be used as common reflectance indicators for monitoring leaf nitrogen accumulation in rice and wheat.
基金National Key Technology R & D Program-On-site Rapid Identification of Drug Research Project (Grant No. 2008BAI55B06)
文摘We analyzed the infrared 0R)-near infrared (NIR) 2D correlation spectra of drugs perturbed by temperature. By identification of functional groups by IR spectrum and by the correlation analysis of IR-NIR spectrum, we identified the characteristic spectral bands that were closely related to the structure of a drug substance of interest. These characteristic spectral bands were relatively less interfered by other ingredients for analysis by the NIR correlation coefficient method. With these characteristic spectral bands, the accuracy of screening illegally added Sildenafil citrate, Tadalafil and Metforrnin hydrochloride in Chinese patent drugs and healthcare products reached about 90%, which met the requirements of rapid screening.
基金Supported by the National Key Research and Development Program of China(2018YFB0504905 and 2018YFB0504900)。
文摘The visible infrared radiometer(VIRR)is the first instrument with longest measurements equipped on the Fengyun(FY)polar-orbiting satellites.Through re-processing of the historic VIRR measurements,long-term(over 20 yr)global data can be integrated from multiple participating VIRRs on a consistent radiometric scale,which are valuable to climate and climate change studies.Due to lack of an onboard calibration system for VIRR,the reflective solar bands must be vicariously calibrated.This study applied the multi-site vicarious approach for consistent calibration of the VIRR visible(VIS)and near-infrared(NIR)data,and produced calibration coefficients for five VIRRs on FY-1 C/D and FY-3 A/B/C.The data quality was then evaluated with observations.The reflectance predicted by using the radiative transfer model over multiple invariant desert and ocean targets was used to derive the calibration slope via a weighted fitting scheme,in which the weights are the inverse of the variance from a radiative transfer simulation evaluated with reference to Aqua moderate resolution imaging spectroradiometer(MODIS).The sensor-specific calibration coefficients were derived on a daily basis by using piecewise polynomials.The calibration reference of the VIRR solar band record was further traced to the Aqua MODIS Collection 6.1 reference calibration with a systematic correction derived from the Libya4 desert.The VIRR record was compared with the Aqua MODIS C6.1 calibration over the polar region based on simultaneous nadir overpass observations.The lifetime relative difference for each sensor are within 3.3%and 4.5%for channels 1 and 2.Invariant deserts were also employed to evaluate the stability and consistency of the VIRR record.In general,the means of the directional and spectral corrected reflectance for each sensor are within 1%of the 20-yr average,implying that the VIRR reflectance of the invariant targets is consistent to within 1%among the sensors for channels 1 and 2.The VIRR data thus derived are reliable.
基金the National Natural Science Foundation of China (No.50074006)
文摘On the basis of a wide range survey of various models or treatment methods for the calculation of radiative properties of gases, box model, which is similar to the gray band approximation of spectral band model, was applied to evaluate the gas properties in this paper. In order to compare the accuracy of box model with that of gray band approximation of spectral band models, a typical one-dimensional gas radiation problem was analyzed using discrete ordinate method. Comparing with the widely used gray band approximation of narrow band model or exponential wide band model, box model can well evaluate the radiation source term of the radiative problem. It also has the advantages of simplicity and easy to code, so it is practicable and useful for some complex engineering problems.