期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Relative spectral response calibration using Ti plasma lines
1
作者 费腾 潘从元 +2 位作者 曾强 王秋平 杜学维 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第4期145-151,共7页
This work introduces the branching ratio(BR) method for determining relative spectral responses,which are needed routinely in laser induced breakdown spectroscopy(LIBS). Neutral and singly ionized Ti lines in the 250... This work introduces the branching ratio(BR) method for determining relative spectral responses,which are needed routinely in laser induced breakdown spectroscopy(LIBS). Neutral and singly ionized Ti lines in the 250–498 nm spectral range are investigated by measuring laser-induced micro plasma near a Ti plate and used to calculate the relative spectral response of an entire LIBS detection system. The results are compared with those of the conventional relative spectral response calibration method using a tungsten halogen lamp, and certain lines available for the BR method are selected. The study supports the common manner of using BRs to calibrate the detection system in LIBS setups. 展开更多
关键词 branching ratio relative spectral response calibration TITANIUM laser-induced breakdown spectroscopy
下载PDF
Online calibration of laser-induced breakdown spectroscopy for detection of heavy metals in water 被引量:2
2
作者 贾尧 赵南京 +5 位作者 方丽 马明俊 孟德硕 殷高方 刘建国 刘文清 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第9期127-132,共6页
In order to reduce the fluctuation of LIBS detection spectrum of liquid sample,the full-spectrum sum method and the internal standardization method is adopted,using an equal-RSD normalization algorithm to calibrate th... In order to reduce the fluctuation of LIBS detection spectrum of liquid sample,the full-spectrum sum method and the internal standardization method is adopted,using an equal-RSD normalization algorithm to calibrate the detection spectrum.Experiment result shows that the full-spectrum sum method reduced the RSD of parallel samples of Cd and Cr to 9.4% and 11.06% from 28.32% and 31.93% respectively,yielded better overall calibration than the singleelement internal standardization approach,thereby suggesting that the former method is convenient and effective for online calibration of LIBS for detection of aqueous heavy metals. 展开更多
关键词 LIBS aqueous heavy metals spectroscopic stability spectral calibration full-spectrum sum method equal-RSD normalization algorithm
下载PDF
Calibration and data restoration of light field modulated imaging spectrometer
3
作者 苏丽娟 严强强 +2 位作者 袁艳 王世丰 刘宇健 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第8期179-186,共8页
A light field modulated imaging spectrometer (LFMIS) can acquire the spatial-spectral datacube of targets of interest or a scene in a single shot. The spectral information of a point target is imaged on the pixels c... A light field modulated imaging spectrometer (LFMIS) can acquire the spatial-spectral datacube of targets of interest or a scene in a single shot. The spectral information of a point target is imaged on the pixels covered by a microlens. The pixels receive spectral information from different spectral filters to the diffraction and misalignments of the optical components. In this paper, we present a linear spectral multiplexing model of the acquired target spectrum. A calibration method is proposed for calibrating the center wavelengths and bandwidths of channels of an LFMIS system based on the liner-variable filter (LVF) and for determining the spectral multiplexing matrix. In order to improve the accuracy of the restored spectral data, we introduce a reconstruction algorithm based on the total least square (TLS) approach. Simulation and experimental results confirm the performance of the spectrum reconstruction algorithm and validate the feasibility of the proposed calibrating scheme. 展开更多
关键词 light field modulated imaging spectrometer linear-variable filter spectral calibration spectral re-construction
下载PDF
Middle and near ultraviolet spectrograph of the Scientific Experimental system in Near SpacE(SENSE)
4
作者 Xin Sun DaLian Shi +6 位作者 Zhen Chen Ran Li WeiWei Cao Jun Zhu YongLin Bai Le Wang Fei He 《Earth and Planetary Physics》 CAS CSCD 2023年第6期655-664,共10页
The Scientific Experimental system in Near SpacE(SENSE)consists of different types of instruments that will be installed on a balloon-based platform to characterize near-space environmental parameters.As one of the ma... The Scientific Experimental system in Near SpacE(SENSE)consists of different types of instruments that will be installed on a balloon-based platform to characterize near-space environmental parameters.As one of the main scientific payloads,the middle and near ultraviolet spectrograph(MN-UVS)will provide full spectra coverage from middle ultraviolet(MUV,200−300 nm)to near ultraviolet(NUV,300−400 nm)with a spectral resolution of 2 nm.Its primary mission is to acquire data regarding the UV radiation background of the upper atmosphere.The MN-UVS is made up of six primary components:a fore-optical module,an imaging grating module,a UV intensified focal plane module,a titanium alloy frame,a spectrometer control module,and a data processing module.This paper presents in detail the engineering design of each functional unit of the MN-UVS,as well as the instrument’s radiometric calibration,wavelength calibration,impact test,and low-pressure discharge test.Furthermore,we are able to report ground test and flight test results of high quality,showing that the MN-UVS has a promising future in upcoming near-space applications. 展开更多
关键词 ultraviolet spectrograph radiation background imaging grating intensified detector low-pressure discharge spectral calibration
下载PDF
Elemental and proximate analysis of coal by x-ray fluorescence assisted laser-induced breakdown spectroscopy 被引量:3
5
作者 田志辉 李晓林 +9 位作者 王钢 张雷 李佳轩 王树青 白禹 张婉飞 岳晗 马晓飞 尹王保 贾锁堂 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第8期55-63,共9页
Although laser-induced breakdown spectroscopy(LIBS),as a fast on-line analysis technology,has great potential and competitiveness in the analysis of chemical composition and proximate analysis results of coal in therm... Although laser-induced breakdown spectroscopy(LIBS),as a fast on-line analysis technology,has great potential and competitiveness in the analysis of chemical composition and proximate analysis results of coal in thermal power plants,the measurement repeatability of LIBS needs to be further improved due to the difficulty in controlling the stability of the generated plasmas at present.In this paper,we propose a novel x-ray fluorescence(XRF) assisted LIBS method for high repeatability analysis of coal quality,which not only inherits the ability of LIBS to directly analyze organic elements such as C and H in coal,but also uses XRF to make up for the lack of stability of LIBS in determining other inorganic ash-forming elements.With the combination of elemental lines in LIBS and XRF spectra,the principal component analysis and the partial least squares are used to establish the prediction model and perform multi-elemental and proximate analysis of coal.Quantitative analysis results show that the relative standard deviation(RSD) of C is 0.15%,the RSDs of other elements are less than 4%,and the standard deviations of calorific value,ash content,sulfur content and volatile matter are 0.11 MJ kg,0.17%,0.79% and 0.41%respectively,indicating that the method has good repeatability in determination of coal quality.This work is helpful to accelerate the development of LIBS in the field of rapid measurement of coal entering the power plant and on-line monitoring of coal entering the furnace. 展开更多
关键词 laser-induced breakdown spectroscopy(LIBS) x-ray fluorescence spectrometry(XRF) high repeatability measurement spectral calibration instability analysis
下载PDF
上一页 1 下一页 到第