期刊文献+
共找到8,243篇文章
< 1 2 250 >
每页显示 20 50 100
STRONGLY CONVERGENT INERTIAL FORWARD-BACKWARD-FORWARD ALGORITHM WITHOUT ON-LINE RULE FOR VARIATIONAL INEQUALITIES
1
作者 姚永红 Abubakar ADAMU Yekini SHEHU 《Acta Mathematica Scientia》 SCIE CSCD 2024年第2期551-566,共16页
This paper studies a strongly convergent inertial forward-backward-forward algorithm for the variational inequality problem in Hilbert spaces.In our convergence analysis,we do not assume the on-line rule of the inerti... This paper studies a strongly convergent inertial forward-backward-forward algorithm for the variational inequality problem in Hilbert spaces.In our convergence analysis,we do not assume the on-line rule of the inertial parameters and the iterates,which have been assumed by several authors whenever a strongly convergent algorithm with an inertial extrapolation step is proposed for a variational inequality problem.Consequently,our proof arguments are different from what is obtainable in the relevant literature.Finally,we give numerical tests to confirm the theoretical analysis and show that our proposed algorithm is superior to related ones in the literature. 展开更多
关键词 forward-backward-forward algorithm inertial extrapolation variational inequality on-line rule
下载PDF
Optimized online filter stack spectrometer for ultrashort X-ray pulses
2
作者 Jia-Xing Wen Ge Ma +17 位作者 Ming-Hai Yu Yu-Chi Wu Yong-Hong Yan Shao-Yi Wang Huai-Zhong Gao Lu-Shan Wang Yu-Gang Zhou Qiang Li Yue Yang Fang Tan Xiao-Hui Zhang Jie Zhang Wen-Bo Mo Jing-Qin Su Wei-Min Zhou Yu-Qiu Gu Ming Zeng Zong-Qing Zhao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第5期85-98,共14页
Currently,with the advent of high-repetition-rate laser-plasma experiments,the demand for online diagnosis for the X-ray spectrum is increasing because the laser-plasma-generated X-ray spectrum is very important for c... Currently,with the advent of high-repetition-rate laser-plasma experiments,the demand for online diagnosis for the X-ray spectrum is increasing because the laser-plasma-generated X-ray spectrum is very important for characterizing electron dynamics and applications.In this study,scintillators and silicon PIN(P-type–intrinsic-N-type semiconductor)diodes were used to construct a wideband online filter stack spectrometer.The X-ray sensor and filter arrangement was optimized using a genetic algorithm to minimize the condition number of the response matrix.Consequently,the unfolding error was significantly reduced based on numerical experiments.The detector responses were quantitatively calibrated by irradiating the scintillator and PIN diode with various nuclides and comparing the measuredγ-ray peaks.A prototype 15-channel spectrometer was developed by integrating an X-ray detector with front-and back-end electronics.The prototype spectrometer could record X-ray pulse signals at a repetition rate of 1 kHz.Furthermore,an optimized spectrometer was employed to record the real-time spectra of laser-driven bremsstrahlung sources.This optimized spectrometer offers a compact solution for spectrum diagnostics of ultrashort X-ray pulses,exhibiting improved accuracy in terms of spectrum measurements and repetition rates,and could be widely used in next-generation high-repetition-rate high-power laser facilities. 展开更多
关键词 Filter stack spectrometer Laser plasma diagnostics X-ray diagnostics Scintillator PIN diode
下载PDF
Design and implementation of the monochromator shielding for the cold neutron spectrometers XINGZHI and BOYA
3
作者 汪晋辰 刘娟娟 +6 位作者 徐大业 Florian Grünauer 郝丽杰 刘蕴韬 张红霞 程鹏 鲍威 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第5期96-102,共7页
An innovative monochromator shielding is designed and implemented for the cold neutron spectrometers XINGZHI and BOYA operated by Renmin University of China at China Advanced Research Reactor.Via Monte Carlo simulatio... An innovative monochromator shielding is designed and implemented for the cold neutron spectrometers XINGZHI and BOYA operated by Renmin University of China at China Advanced Research Reactor.Via Monte Carlo simulations and careful mechanical designs,a shielding configuration has been successfully developed to satisfy safety requirements of below 3μSv/h dose rate at its exterior,meanwhile fulfilling space,floor load and nonmagnetic requirements.Composite materials are utilized to form the sandwich-type shielding walls:the inner layer of boron carbide rubber,the middle layer of steel-encased lead and the outer layer of borated polyethylene.Special-shaped liftable shielding blocks are incorporated to facilitate a continuous adjustment of the neutron energy while preventing radiation leakage.Our work has demonstrated that by utilizing composite shielding materials,along with the sandwich structure and liftable shielding blocks,a compact and lightweight shielding solution can be achieved.This enables the realization of advanced neutron scattering instruments that provide expanded space of measurement,larger energy and momentum coverage,and higher flux on the sample.This shielding represents the first of its kind in neutron scattering instruments in China.Following its successful operation,it has been subsequently employed by other neutron instruments across the country. 展开更多
关键词 neutron scattering cold neutron spectrometer monochromator shielding sandwich shielding structure
下载PDF
Artificial neural network-based method for discriminating Compton scattering events in high-purity germaniumγ-ray spectrometer
4
作者 Chun-Di Fan Guo-Qiang Zeng +5 位作者 Hao-Wen Deng Lei Yan Jian Yang Chuan-Hao Hu Song Qing Yang Hou 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第2期64-84,共21页
To detect radioactive substances with low activity levels,an anticoincidence detector and a high-purity germanium(HPGe)detector are typically used simultaneously to suppress Compton scattering background,thereby resul... To detect radioactive substances with low activity levels,an anticoincidence detector and a high-purity germanium(HPGe)detector are typically used simultaneously to suppress Compton scattering background,thereby resulting in an extremely low detection limit and improving the measurement accuracy.However,the complex and expensive hardware required does not facilitate the application or promotion of this method.Thus,a method is proposed in this study to discriminate the digital waveform of pulse signals output using an HPGe detector,whereby Compton scattering background is suppressed and a low minimum detectable activity(MDA)is achieved without using an expensive and complex anticoincidence detector and device.The electric-field-strength and energy-deposition distributions of the detector are simulated to determine the relationship between pulse shape and energy-deposition location,as well as the characteristics of energy-deposition distributions for fulland partial-energy deposition events.This relationship is used to develop a pulse-shape-discrimination algorithm based on an artificial neural network for pulse-feature identification.To accurately determine the relationship between the deposited energy of gamma(γ)rays in the detector and the deposition location,we extract four shape parameters from the pulse signals output by the detector.Machine learning is used to input the four shape parameters into the detector.Subsequently,the pulse signals are identified and classified to discriminate between partial-and full-energy deposition events.Some partial-energy deposition events are removed to suppress Compton scattering.The proposed method effectively decreases the MDA of an HPGeγ-energy dispersive spectrometer.Test results show that the Compton suppression factors for energy spectra obtained from measurements on ^(152)Eu,^(137)Cs,and ^(60)Co radioactive sources are 1.13(344 keV),1.11(662 keV),and 1.08(1332 keV),respectively,and that the corresponding MDAs are 1.4%,5.3%,and 21.6%lower,respectively. 展开更多
关键词 High-purity germaniumγ-ray spectrometer Pulse-shape discrimination Compton scattering Artificial neural network Minimum detectable activity
下载PDF
An empirical method for joint inversion of wave and wind parameters based on SAR and wave spectrometer data
5
作者 Yong Wan Xiaona Zhang +2 位作者 Shuyan Lang Ennan Ma Yongshou Dai 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2024年第5期133-144,共12页
Synthetic aperture radar(SAR)and wave spectrometers,crucial in microwave remote sensing,play an essential role in monitoring sea surface wind and wave conditions.However,they face inherent limitations in observing sea... Synthetic aperture radar(SAR)and wave spectrometers,crucial in microwave remote sensing,play an essential role in monitoring sea surface wind and wave conditions.However,they face inherent limitations in observing sea surface phenomena.SAR systems,for instance,are hindered by an azimuth cut-off phenomenon in sea surface wind field observation.Wave spectrometers,while unaffected by the azimuth cutoff phenomenon,struggle with low azimuth resolution,impacting the capture of detailed wave and wind field data.This study utilizes SAR and surface wave investigation and monitoring(SWIM)data to initially extract key feature parameters,which are then prioritized using the extreme gradient boosting(XGBoost)algorithm.The research further addresses feature collinearity through a combined analysis of feature importance and correlation,leading to the development of an inversion model for wave and wind parameters based on XGBoost.A comparative analysis of this model with ERA5 reanalysis and buoy data for of significant wave height,mean wave period,wind direction,and wind speed reveals root mean square errors of 0.212 m,0.525 s,27.446°,and 1.092 m/s,compared to 0.314 m,0.888 s,27.698°,and 1.315 m/s from buoy data,respectively.These results demonstrate the model’s effective retrieval of wave and wind parameters.Finally,the model,incorporating altimeter and scatterometer data,is evaluated against SAR/SWIM single and dual payload inversion methods across different wind speeds.This comparison highlights the model’s superior inversion accuracy over other methods. 展开更多
关键词 synthetic aperture radar(SAR) wave spectrometer extreme gradient boosting(XGBoost) joint inversion method wave and wind parameters
下载PDF
One-step Eco-friendly Fabrication of Antibacterial Polyester Via On-line Amination Reaction by Melt Coextrusion
6
作者 ZHANG Huan ZHAO Qinghua +4 位作者 ZHONG Yaping CAI Ruiyan LIU Ke WANG Dong LU Zhentan 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS CSCD 2023年第5期1205-1212,共8页
The work is dedicated to develop a one-step eco-friendly method to prepare antibacterial polyethylene terephthalate(PET).We report a one-step eco-friendly method to manufacture antibacterial PET via on-line amination ... The work is dedicated to develop a one-step eco-friendly method to prepare antibacterial polyethylene terephthalate(PET).We report a one-step eco-friendly method to manufacture antibacterial PET via on-line amination reaction by melt coextrusion.Beside evenly mixing of poly(hexamethylene guanidine)(PHMG)and PET in the melt coextrusion procedure,the amination reaction also occurred between PHMG and PET under high temperature(230-270℃).The antibacterial ability of composite PET showed obvious PHMG concentration dependence,and antibacterial activity reached more than 99%when PHMG content was 2.5 wt%.Moreover,LIVE/DEAD fluorescence test further confirmed that the composite PET could kill bacteria quickly and efiectively(within 30 min);while negligible cytotoxicity was observed to HSF and HUVEC cells.Onestep eco-friendly fabrication of composite antibacterial PET was accomplished by on-line melt coextrusion.The composite antibacterial PET has potential use in multiple fields to combat with pathogenic including textiles,packaging materials,decoration materials and biomedical devices,etc. 展开更多
关键词 antibacterial polyester one-step eco-friendly method on-line amination reaction melt coextrusion cytocompatibility
下载PDF
Rapid analysis of fifteen sulfonamide residues in pork and fish samples by automated on-line solid phase extraction coupled to liquid chromatography–tandem mass spectrometry 被引量:6
7
作者 Junmei Ma Sufang Fan +3 位作者 Lei Sun Liangna He Yan Zhang Qiang Li 《Food Science and Human Wellness》 SCIE 2020年第4期363-369,共7页
The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples... The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples were extracted with 0.2%formic acid acetonitrile solution,purified by on-line SPE device with HLB column,then separated by XBridge C18 column,using 0.1%formic acid solution and acetonitrile as the mobile phase.Mass spectrometric data was acquired under multiple reaction monitoring(MRM)mode using positive ionization electrospray.Internal standard method was used in the quantification,good linear relationship was got in range of 0.1–100 ng/mL and correlation coefficient was higher than 0.9990.The limits of detection were in the range of 0.125–2.00g/kg and the limits of quantitation were in the range of 0.250–5.00g/kg.Recoveries of the method were in range of 78.3%–99.3%,relative standard deviation were lower than 10%.The method was simple,sensitivity,and could be used for routine supervision and analysis of fifteen sulfonamides in pork and fish. 展开更多
关键词 Liquid chromatography–tandem mass spectrometRY on-line solid phase extraction SULFONAMIDES Internal standard quantification
下载PDF
Design and calibration of an elliptical crystal spectrometer for the diagnosis of proton-induced x-ray emission(PIXE)
8
作者 方言律 李东彧 +9 位作者 程浩 高原 申泽清 杨童 李昱泽 夏亚东 晏炀 颜莎 林晨 颜学庆 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第11期220-225,共6页
Laser-driven proton-induced x-ray emission(laser-PIXE) is a nuclear analysis method based on the compact laser ion accelerator. Due to the transient process of ion acceleration, the laser-PIXE signals are usually spur... Laser-driven proton-induced x-ray emission(laser-PIXE) is a nuclear analysis method based on the compact laser ion accelerator. Due to the transient process of ion acceleration, the laser-PIXE signals are usually spurted within nanoseconds and accompanied by strong electromagnetic pulses(EMP), so traditional multi-channel detectors are no longer applicable.In this work, we designed a reflective elliptical crystal spectrometer for the diagnosis of laser-PIXE. The device can detect the energy range of 1 keV–11 ke V with a high resolution. A calibration experiment was completed on the electrostatic accelerator of Peking University using samples of Al, Ti, Cu, and ceramic artifacts. The detection efficiency of the elliptical crystal spectrometer was obtained in the order of 10-9. 展开更多
关键词 elliptical crystal spectrometer proton-induced x-ray emission applications of laser ion accelera-tion
下载PDF
Evaluation of Uncertainty in Determination of Ethyl Maltol in Vegetable Oil by Ultra-high Performance Liquid Chromatograph-Mass Spectrometer(UPLC-MS)
9
作者 Lei ZHANG 《Agricultural Biotechnology》 CAS 2023年第3期113-115,共3页
[Objectives]This study was conducted to establish an uncertainty evaluation method for the determination of ethyl maltol by ultra-high performance liquid chromatograph-mass spectrometer(UPLC-MS).[Methods]A mathematica... [Objectives]This study was conducted to establish an uncertainty evaluation method for the determination of ethyl maltol by ultra-high performance liquid chromatograph-mass spectrometer(UPLC-MS).[Methods]A mathematical model of uncertainty was established by analyzing the method for determining ethyl maltol using UPLC-MS.The sources of uncertainty were analyzed,and the components of uncertainty were calculated to evaluate the expanded uncertainty of the method.[Results]When the content of ethyl maltol in edible vegetable oil was 1657μg/kg,the expanded uncertainty was 22.4μg/kg(K=2,P=95%).[Conclusions]The uncertainty in this evaluation model mainly came from standard solution preparation,sample weighing,dilution of sample to constant volume,standard curve fitting,and repeated measurement. 展开更多
关键词 Ultra-high performance liquid chromatograph-mass spectrometer DETERMINATION Ethyl maltol Uncertainty
下载PDF
Accuracy analysis of iron content of galvanized coating using an X-ray fluorescence spectrometer with an L-spectrum
10
作者 WANG Jingjing CHEN Yanfei 《Baosteel Technical Research》 CAS 2023年第4期35-40,共6页
The accuracy(repeatability and reproducibility) of the iron content analysis of galvanized coating using an X-ray fluorescence spectrometer with an L-spectrum is not better than that of flame atomic absorption spectro... The accuracy(repeatability and reproducibility) of the iron content analysis of galvanized coating using an X-ray fluorescence spectrometer with an L-spectrum is not better than that of flame atomic absorption spectrometry, sometimes it exceeds the quality control limit.Influences, such as current, voltage, equipment(internal circulating water, 10%CH4+90%Ar, and vacuum) checking, instrument monitoring, sample cleaning, and oper-ators, were investigated by means of 6-sigma and lean operations to improve accuracy. 展开更多
关键词 X-ray fluorescence spectrometer Lspectrum galvanized coating iron content
下载PDF
Cobalt Determination by Means of Flow Injection On-line Sorbent Preconcentration-Flame Atomic Absorption Spectrometry with 1-Nitroso-2-naphthol as a Complexing Reagent
11
作者 YIN Xue-feng ALI Akbar +3 位作者 XU Guang-ming LING Yun-yang GAO Jian YE Mei-ying 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2001年第3期264-270,共7页
The suitability of 1-nitroso-2-naphthol(NN) as a complexing agent for on-line preconcentration of cobalt eluted on the C_(18) microcolumn by means of the FI-FAAS system was tested. Various parameters affecting the com... The suitability of 1-nitroso-2-naphthol(NN) as a complexing agent for on-line preconcentration of cobalt eluted on the C_(18) microcolumn by means of the FI-FAAS system was tested. Various parameters affecting the complex formation and its elution were optimized. A 2.3×10^(-3) mol/L reagent solution and the aqueous sample solution acidified with 0.1% (volume fraction) nitric acid were on-line mixed (6.4 mL/min) on a reaction coil set at (65±1)℃ and flowed through the microcolumn for 30 s. The pH of the mixed solution was adjusted to 3—4 with HNO_3(1 mol/L) or NaOH(1 mol/L). The adsorbed complexes in the microcolumn were eluted into the nebulizer of FAAS in 10 s with ethanol acidified with 1% HNO_3(3.0 mL/min). A good precision(1.6% for 100μg/L Co(Ⅱ), n=10), a high enrichment factor 17.2, with detection limit (3σ) 3.2μg/L, and sample throughput (90 h^(-1)) were obtained. The method was applied to the certified reference materials(CRMs), NBS-362 and NBS-364, for the determination of cobalt and the results were in good agreement with the certified values. 展开更多
关键词 Cobalt FI on-line preconcentration AAS 1-Nitroso-2-naphthol
下载PDF
DETERMINATION OF ANTIMONY IN WATER SAMPLES BY FLOW-INJECTION HYDRIDE GENERATION ATOMIC ABSORPTION SPECTROMETRY WITH ON-LINE ION-EXCHANGE COLUMN PRECONCENTRATION
12
作者 Shu Kun XU and Zhao Lun FANG Institute of Applied Ecology, Academia Sinica, Shenyang, 110015 《Chinese Chemical Letters》 SCIE CAS CSCD 1992年第11期915-918,共4页
On-line ion-exchange separation and preconcentration were combined with flow-injection hydride generation atomic absorption spectrometry (HGAAS) to determine ultra-trace amounts of antimony in water samples. Antimony(... On-line ion-exchange separation and preconcentration were combined with flow-injection hydride generation atomic absorption spectrometry (HGAAS) to determine ultra-trace amounts of antimony in water samples. Antimony(Ⅲ) was preconcentrated on a micro-column packed with CPG-8Q chelating ion-exchanger using time-based sample loading and eluted by 4 mol l^(-1) HCl directly into the hydride generation AAS system. A detection limit (3σ) of 0.0015μg l^(-1) Sb(Ⅲ) was obtained on the basis of a 20 fold enrichment and with a sampling frequency of 60h^(-1). The precision was 1.0% r.s.d.(n=11) at the 0.5μg l^(-1) Sb(Ⅲ) level. Recoveries for the analysis of antimony in tap water, snow water and sea water samples were in the range 97-102%. 展开更多
关键词 Zhang DETERMINATION OF ANTIMONY IN WATER SAMPLES BY FLOW-INJECTION HYDRIDE GENERATION ATOMIC ABSORPTION spectrometRY WITH on-line ION-EXCHANGE COLUMN PRECONCENTRATION SQ CPG ION LINE
下载PDF
On-line机行血液透析滤过两种稀释模式效果的临床观察 被引量:2
13
作者 易铁钢 祁爱蓉 程淑碧 《中国血液净化》 2004年第1期41-42,47,共3页
关键词 on-line 血液透析滤过 稀释模式 HDF 治疗 血液净化
下载PDF
On-line hemodiafiltration技术和临床应用 被引量:25
14
作者 谢红浪 季大玺 《肾脏病与透析肾移植杂志》 CAS CSCD 2005年第4期377-381,共5页
关键词 血液净化 肾脏疾病 临床 on-line 临床应用 肾脏替代治疗 终末期肾脏疾病 血液透析滤过 常规血液透析 生物相容性
下载PDF
On-line血液透析滤过对移植肾功能延迟恢复的影响 被引量:1
15
作者 余权星 刘强 +2 位作者 杜艺 李宓 彭莉 《中国血液净化》 2004年第4期192-193,200,共3页
目的 研究On -line血液透析滤过 (HDF)在移植肾功能延迟恢复患者中的应用。方法 我院2 0 0 2年 1月至 2 0 0 3年 7月肾移植术后发生移植肾功能延迟恢复患者 38例 ,2 9例采用Freseniuson -lineHDF透析机 ,F6 0透析器 ,透析滤过时间 3~... 目的 研究On -line血液透析滤过 (HDF)在移植肾功能延迟恢复患者中的应用。方法 我院2 0 0 2年 1月至 2 0 0 3年 7月肾移植术后发生移植肾功能延迟恢复患者 38例 ,2 9例采用Freseniuson -lineHDF透析机 ,F6 0透析器 ,透析滤过时间 3~ 4h ,血流量在 180~ 2 5 0ml/min ,置换液采取前稀释法 ,9例行HD治疗 ,采用GambroAK2 0 0透析机 ,F7透析器。结果  38例移植肾功能延迟恢复患者 ,2 9例用联机血液透析滤过 ,平均肾功能恢复时间为 ( 11.2± 5 .6 )天 ,治疗期间收缩压变化在 110~ 170mmHg,透析期间低血压发生率为 2 .6 % ,9例HD治疗者平均肾功能恢复时间为 ( 2 2 .3± 15 .7)天 ,透析期间低血压发生率为 13.2 %。结论 与HD比较 ,On -lineHDF对血压影响较小 ,可缩短移植肾功能恢复的时间。 展开更多
关键词 on-line血液透析 肾功能 肾移植 HDF
下载PDF
平行机的实时到达on-line算法下界的改进 被引量:1
16
作者 陈仕平 姚恩瑜 《高校应用数学学报(A辑)》 CSCD 北大核心 1999年第3期315-318,共4页
本文考虑了平行机实时到达的在线问题.模型中,工件是陆续到达的,工件的个数、到达时间是事先未知的,而且只有当工件到达,才知其加工时间,目标是使所有工件都加工完的时间达到最小.Chen与Vestjens(1996年)证明... 本文考虑了平行机实时到达的在线问题.模型中,工件是陆续到达的,工件的个数、到达时间是事先未知的,而且只有当工件到达,才知其加工时间,目标是使所有工件都加工完的时间达到最小.Chen与Vestjens(1996年)证明了该在线问题不存在性能比小于1.3473的on-line算法.本文将此界改进为(5-5)/2. 展开更多
关键词 排序 on-line算法 平行机 组合最优化 实时到达
下载PDF
On-line血液透析滤过对维持性血液透析患者心率变异性的影响 被引量:5
17
作者 侯丹丹 王淑领 尚赛男 《临床和实验医学杂志》 2017年第17期1761-1764,共4页
目的探讨On-line血液透析滤过技术对维持性血液透析患者心率变异性(HRV)的影响。方法 50例维持性血液透析(MHD)患者随机分为常规血液透析治疗组(HD组)和On-line血液透析滤过治疗组(OL-HDF组),每组各25例。患者每周行3次、每次4 h的血液... 目的探讨On-line血液透析滤过技术对维持性血液透析患者心率变异性(HRV)的影响。方法 50例维持性血液透析(MHD)患者随机分为常规血液透析治疗组(HD组)和On-line血液透析滤过治疗组(OL-HDF组),每组各25例。患者每周行3次、每次4 h的血液透析治疗或OL-HDF,治疗24个月。比较两组常规的实验室检查和24h动态心电图监测结果。结果治疗24个月后,OL-HDF组的β2-微球蛋白(β2-MG)由基线值30.1±7.2 mg/dl降至21.7±6.1 mg/dl(P<0.05),HD组的β2-MG则无明显下降。OL-HDF组HRV的时域性和频域性指标均值高于基线值(P<0.05),HD组的HRV指标则无显著性变化(P>0.05)。结论与普通血液透析比较,OL-HDF能更好地改善MHD患者的HRV,改善自主神经功能。 展开更多
关键词 维持性血液透析 on-line血液透析滤过心率变异性
下载PDF
On-line置换液与生理盐水在血液透析滤过回血中的应用效果比较 被引量:5
18
作者 祝喜鹰 刘金凤 肖静 《护理研究(上旬版)》 2014年第7期2370-2372,共3页
[目的]探讨On-line置换液与生理盐水在血液透析滤过(HDF)病人回血中的应用效果,以期为临床护理工作提供理论依据。[方法]选取30例规律HDF病人为研究对象,采用自身对照方法,每例病人每周依次采用On-line置换液和生理盐水回血,比较回血过... [目的]探讨On-line置换液与生理盐水在血液透析滤过(HDF)病人回血中的应用效果,以期为临床护理工作提供理论依据。[方法]选取30例规律HDF病人为研究对象,采用自身对照方法,每例病人每周依次采用On-line置换液和生理盐水回血,比较回血过程中残余血量、静脉壶液体温度、护士的工作量及经济效益。[结果]采用On-line置换液回血法残余血量及回血后静脉壶温度分别为(1.89±0.91)mL,(33.36±0.15)℃,而采用生理盐水法为(2.88±0.23)mL、(27.13±0.14)℃,差异均有统计学意义(P<0.01);而透析器凝血状况比较差异无统计学意义(P=0.08);采用On-line置换液回血时护士工作量减少,回血液体成本降低。[结论]应用接近生理温度的On-line置换液回血能稀释血液、降低血液黏稠度,减少血路管残余血量,增加病人舒适感,提高工作效率。 展开更多
关键词 联机血液透析滤过 液体回血 on-line置换液 生理盐水 残余血量 工作量
下载PDF
On-lineHDF的临床观察及护理 被引量:1
19
作者 李虹 张永勤 汪吉平 《实用全科医学》 2004年第3期280-281,共2页
目的 探讨应用On -lineHDF治疗慢性肾衰尿毒症患者的临床效果及护理对策。方法 回顾性分析 15例维持性HD患者应用On -lineHDF的治疗及护理过程。结果  15例患者经每 1~ 2周 1次的On -lineHDF治疗后 ,病情稳定 ,部分患者心功能、血... 目的 探讨应用On -lineHDF治疗慢性肾衰尿毒症患者的临床效果及护理对策。方法 回顾性分析 15例维持性HD患者应用On -lineHDF的治疗及护理过程。结果  15例患者经每 1~ 2周 1次的On -lineHDF治疗后 ,病情稳定 ,部分患者心功能、血压、食欲、体力及睡眠不同成度得到改善 ,在促红细胞生成素使用量不变的情况下 ,4例病人的血红蛋白有所增加。结论 On -lineHDF是当今最佳的肾脏替代疗法技术之一。 展开更多
关键词 on-line HDF 护理措施 血液透析 置换液 治疗
下载PDF
On-line HDF治疗维持性透析患者并发症的护理
20
作者 孙静 安茂竹 +2 位作者 毛继芳 秦美华 马芳 《当代护士(中旬刊)》 2007年第10期32-33,共2页
对20例维持性透析并发难治性高血压、顽固性瘙痒、不安腿综合征等患者,采用每周2次血液透析+1次on-line HDF,加强观察和护理。患者血压得到良好的控制,皮肤瘙痒得到明显改善,不安腿症状有所好转,贫血、食欲减退、精神和神经症状得到改善... 对20例维持性透析并发难治性高血压、顽固性瘙痒、不安腿综合征等患者,采用每周2次血液透析+1次on-line HDF,加强观察和护理。患者血压得到良好的控制,皮肤瘙痒得到明显改善,不安腿症状有所好转,贫血、食欲减退、精神和神经症状得到改善,生活质量明显提高。 展开更多
关键词 透析 并发症 on-line HDF 护理
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部