A novel method for on-site determination of trace iron was developed using membrane preconcentration and spectrophotometric detection. Fe(II)-ferrozine complex was reacted with cetyltrimethylammonium bromide (CTAB...A novel method for on-site determination of trace iron was developed using membrane preconcentration and spectrophotometric detection. Fe(II)-ferrozine complex was reacted with cetyltrimethylammonium bromide (CTAB) to form a Fe(II)-ferrozine-CTAB paired compound, which was collected on a membrane by filtration under vacuum. The membrane was immersed in 2 mL of ethanol-nitric acid and the absorbance of the solution measured for quantitative analysis. Various factors affecting the iron collection and determination were investigated. With different sample preconcentration volumes, the range of determination was broadened to 0.5-120 ~tg/L. The detection limit of this method reached 0.19 ktg/L and the recoveries were between 97.2 and 109% when the concentration enrichment was about 45. The relative standard deviation (n = 7) was 1.9% for samples containing 10 ~g/L Fe. Twelve seawater samples were analyzed on-site using the proposed method, and two were also analyzed in inductively coupled plasma mass spectrometry. No significant difference was shown between the two methods by the Student's t-test. The method has also been used on-site for iron enrichment experiments with phytoplankton and concluded to be simple, accurate and inexpensive.展开更多
A rapid and sensitive on-line preconcentration method for spectrophotometric determination of chromium (VI) in nature water is described. Preconcentration and determination are based on (i) the quantitative and fast a...A rapid and sensitive on-line preconcentration method for spectrophotometric determination of chromium (VI) in nature water is described. Preconcentration and determination are based on (i) the quantitative and fast adsorption of chromium (VI) on the high surface area nanometer-size TiO2 (anatase) powders, which prepared by a sol-gel method from hydrolysis of TiCI4 and (ii) the quantitative and reproducible elution of Cr (VI) by 2. 0 mol. L-1 HCI. A mini-column system for preconcentration is developed, Cr(VI)on the mini-column is eluted and merged with a stream water and DPCB (1, 5-diphenylcarbazide ) as the chromogenic reagent. The Proposed system permits throughputs of 6 sample h--l (0. 001 μg mL-1 Cr(VI) ) or 20 sample h-1 (0. 1 μg mL-1Cr (VI) . The preconcentration factor is 55. The detection limit is 0. 8 ng·mL-1 Cr(VI). The reproducibility is satisfactory with a relative standard deviation of less than 3. 35% (0. Of μg'mL-1Cr (VI), n = 5).展开更多
基金Supported by State Key Laboratory of Marine Environmental Science(MEL)Funds(No.MELRI1001)
文摘A novel method for on-site determination of trace iron was developed using membrane preconcentration and spectrophotometric detection. Fe(II)-ferrozine complex was reacted with cetyltrimethylammonium bromide (CTAB) to form a Fe(II)-ferrozine-CTAB paired compound, which was collected on a membrane by filtration under vacuum. The membrane was immersed in 2 mL of ethanol-nitric acid and the absorbance of the solution measured for quantitative analysis. Various factors affecting the iron collection and determination were investigated. With different sample preconcentration volumes, the range of determination was broadened to 0.5-120 ~tg/L. The detection limit of this method reached 0.19 ktg/L and the recoveries were between 97.2 and 109% when the concentration enrichment was about 45. The relative standard deviation (n = 7) was 1.9% for samples containing 10 ~g/L Fe. Twelve seawater samples were analyzed on-site using the proposed method, and two were also analyzed in inductively coupled plasma mass spectrometry. No significant difference was shown between the two methods by the Student's t-test. The method has also been used on-site for iron enrichment experiments with phytoplankton and concluded to be simple, accurate and inexpensive.
文摘A rapid and sensitive on-line preconcentration method for spectrophotometric determination of chromium (VI) in nature water is described. Preconcentration and determination are based on (i) the quantitative and fast adsorption of chromium (VI) on the high surface area nanometer-size TiO2 (anatase) powders, which prepared by a sol-gel method from hydrolysis of TiCI4 and (ii) the quantitative and reproducible elution of Cr (VI) by 2. 0 mol. L-1 HCI. A mini-column system for preconcentration is developed, Cr(VI)on the mini-column is eluted and merged with a stream water and DPCB (1, 5-diphenylcarbazide ) as the chromogenic reagent. The Proposed system permits throughputs of 6 sample h--l (0. 001 μg mL-1 Cr(VI) ) or 20 sample h-1 (0. 1 μg mL-1Cr (VI) . The preconcentration factor is 55. The detection limit is 0. 8 ng·mL-1 Cr(VI). The reproducibility is satisfactory with a relative standard deviation of less than 3. 35% (0. Of μg'mL-1Cr (VI), n = 5).