期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Assessment the Optimal Effect of Time of Repetition: Extrinsic Pulse Parameter on Gd-DTPA Enhanced, Spin-Echo T1-Weighted MR Images under Low Magnetic Field Strength
1
作者 Bimali Sanjeevani Weerakoon Toshiaki Osuga Takehisa Konishi 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2016年第3期196-203,共9页
The contrast agent concentration, the time of repetition (TR) and magnetic field strength are significant parameters that influence for the accurate signal intensity (SI) in quantitative Magnetic Resonance Imaging (MR... The contrast agent concentration, the time of repetition (TR) and magnetic field strength are significant parameters that influence for the accurate signal intensity (SI) in quantitative Magnetic Resonance Imaging (MRI). Therefore, this study was conducted to investigate and refine the dependence and the optimal effect of Time of Repetition (TR) on the relationship between signal intensity and Gd-DTPA (Gadolinium-diethylene-triaminepenta-acetic acid) concentration, after applying two-dimensional (2D) Spin Echo (SE) pulse sequence under low-field MRI. In addition to that, the optimal concentration of Gd-DTPA at given sequence parameters at low-field MRI was also evaluated. A water-filled phantom was constructed for a range of Gd-DTPA concentrations (0 - 6 mmol/L) and the mean signal intensities (SIs) were assessed in the defined region of interest on T1-weighted images with different TR values (40 - 2000 ms). The generated signal-concentration curves for Gd-DTPA revealed that increasing TR was associated with the increase of the overall SIs and the maximum relationship between SI to concentration. Moreover, the required Gd-DTPA concentration to produce the maximum SI was associated to decrease with the increase of TR. In addition to this, the application of beyond 100 ms TR values in this study with relatively higher concentrations (beyond 1 - 2 mmol/L) has resulted predominantly non-linear patterns in the signal-concentration curves and it appears the saturation or decay of the SIs due to T2 effect. From these results, it can be suggested that the selection of relatively lower Gd-DTPA concentration ( mmol/L) with less than 800 ms (<800 ms) TR values can produce a better linear relationship between the concertation and SIs in T1-weighted SE low field contrast-enhanced MRI. Furthermore, this study also outlined the significance and necessity of the optimization of TR in SE sequence in low field MRI prior to a particular examination. 展开更多
关键词 Gd-DTPA Concentration Spin echo Pulse Sequence Signal Intensity Time of Repetition T1-Weighted Images Low Field MRI
下载PDF
NV色心磁测量研究现状及发展趋势 被引量:5
2
作者 马宗敏 郭卫军 +4 位作者 郑斗斗 王军旗 柴笑晗 牛刘敏 秦丽 《微纳电子技术》 北大核心 2020年第9期754-762,共9页
综述了金刚石氮空位(NV)色心磁测量研究现状及发展趋势。对NV色心DC磁测量和AC磁测量主要方法进行了系统的对比分析,着重介绍了采用连续波光探测磁共振(CW-ODMR)方法检测DC磁场的发展趋势并分析其优势和不足之处,以及利用Spin Echo技术... 综述了金刚石氮空位(NV)色心磁测量研究现状及发展趋势。对NV色心DC磁测量和AC磁测量主要方法进行了系统的对比分析,着重介绍了采用连续波光探测磁共振(CW-ODMR)方法检测DC磁场的发展趋势并分析其优势和不足之处,以及利用Spin Echo技术对AC磁测量的分析研究。然后介绍了NV色心在集成NV色心磁力计、体细胞NV色心磁测量以及硬盘驱动器检测等方面的应用,指出未来NV色心磁测量主要向高灵敏度、小型化、集成化、便携化的方向发展。最后分析得出NV色心DC磁测量存在微波和激光功率导致ODMR线宽展宽,延长退相位时间是提高DC磁灵敏度最主要的手段。NV色心AC磁测量则对系统电噪声和磁噪声等环境因素要求较高,延长退相干时间是提高AC磁灵敏度的关键因素。 展开更多
关键词 金刚石 氮空位(NV)色心 AC磁测量 DC磁测量 连续波光探测磁共振(CW-ODMR) Spin echo
下载PDF
APPLICATION VALUE OF MAGNETIC RESONANCE SEQUENCES IN DIAGNOSIS OF EARLY SPINAL METASTATIC TUMOR 被引量:1
3
作者 Li-xia Wang Xiang-quan Kong He-shui Shi Ding-xi Liu Yin Xiong 《Chinese Medical Sciences Journal》 CAS CSCD 2007年第1期9-12,共4页
Objective To investigate the clinical value of different magnetic resonance (MR) pulse sequences in diagnosis of spinal metastatic tumor. Methods Fifteen patients with clinically suspected spinal metastatic tumor were... Objective To investigate the clinical value of different magnetic resonance (MR) pulse sequences in diagnosis of spinal metastatic tumor. Methods Fifteen patients with clinically suspected spinal metastatic tumor were included in this study. These patients were with documented primary tumors. Four MR pulse sequences, T1-weighted spin echo (T1WI SE), T2-weighted fast spin echo (T2WI FSE), short time inversion recovery (STIR), and gradient echo 2-D multi echo data imaging combination (GE Me-2D) were used to detect spinal metastasis. Results Fifteen vertebral bodies were entire involvement, 38 vertebral bodies were section involvement, and totally 53 vertebral bodies were involved. There were 19 focal infections in pedicle of vertebral arch, 15 metastases in spinous process and transverse process. Fifty-three vertebral bodies were abnormal in T1WI SE and GE Me-2D, 35 vertebral bodies were found abnormal in T2WI FSE, and 50 vertebral bodies were found abnormal in STIR. The verges of focal signal of involved vertebral bodies were comparatively clear in T1WI SE, comparatively clear or vague in T2WI FSE, vague in STIR, and clear in GE Me-2D.Conclusions GE Me-2D may be the most sensitive technique to detect metastases. So three sequences (T1WI SE, T2WI FSE, GE Me-2D) can demonstrate the early changes of spinal metastasis roundly. 展开更多
关键词 spinal metastatic tumor T1-weighted spin echo T2-weighted fast spin echo gradient echo 2-D multi echo data imaging combination
下载PDF
Two methods to deal with an inhomogenous Rabi frequency in microwave transition
4
作者 程峰 王育竹 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第7期141-145,共5页
We analyse the influence of an inhomogenous microwave field on the coherence of atom ensembles. Two methods are proposed to suppress the dephasing generated by the inhomogenous Rabi frequency. One of them is realized ... We analyse the influence of an inhomogenous microwave field on the coherence of atom ensembles. Two methods are proposed to suppress the dephasing generated by the inhomogenous Rabi frequency. One of them is realized by using a spin echo, and the other one is based on the identical spin rotation effect. The calculation results show that the contrast of a signal acquired in experiment can be improved by using the two methods. Their advantages and drawbacks are discussed. We hope they can be used to improve the contrast of experimental signals in situations where microwave fields are very inhomogenous. Finally, we discuss the case of a continuous working microwave field and show that the dipole force raised with the inhomogeneitv can be eased by slain flip. 展开更多
关键词 inhomogenous microwave field spin echo identical spin rotation effect
下载PDF
Contrast Optimization for an Animal Model of Prostate Cancer MRI at 3T
5
作者 Christopher Brian Abraham Boguslaw Tomanek Laura Curiel 《Journal of Modern Physics》 2016年第8期819-826,共8页
Purpose: To optimize contrast to noise ratio (CNR) in magnetic resonance imaging (MRI) of prostate cancer using at 3T. Methods: CNR was expressed as a difference in MR signals of two samples. Amulti-echo spin-echo (ME... Purpose: To optimize contrast to noise ratio (CNR) in magnetic resonance imaging (MRI) of prostate cancer using at 3T. Methods: CNR was expressed as a difference in MR signals of two samples. Amulti-echo spin-echo (MESE) pulse sequence was used. The theoretical value of the maximum CNR was obtained using the derivative of CNR with echo time (TE) as a variable. The T<sub>1</sub> relaxation time was ignored as repetition time (TR) was assumed to be very long (TR >> T<sub>1</sub>). The theoretical calculations were confirmed with in vitro and in vivo experiments. For in vitro experiments we used samples with different T<sub>2</sub> values using various concentrations of super paramagnetic iron oxide (SPIO) and for in vivo experiments we used an animal model of prostate cancer. Results: CNR was maximized by selecting the optimum TE for a multi-echo spin-echo (MESE) pulse sequence based on theoretical predictions. MR images of prostate cancer at 3T were obtained and showed maximum CNR at the predicted TE. Conclusions: It was possible to maximize CNR of prostate tumour by selecting the optimal TE based on simple theoretical calculations. The proposed method can be applied to other pulse sequences and tissues. It can be applied to any MRI system at any magnetic field. However the method requires knowledge of T<sub>2</sub> relaxation times. 展开更多
关键词 MRI Tissue Contrast Prostate Cancer Spin echo
下载PDF
Magnetic Resonance Three-dimensional Cube Technique in the Measurement of Piglet Femoral Anteversion 被引量:2
6
作者 Dong-Mei Sun Shi-Nong Pan +3 位作者 En-Bo Wang Li-Qiang Zheng Wen-Li Guo Xi-Hu Fu 《Chinese Medical Journal》 SCIE CAS CSCD 2016年第13期1584-1591,共8页
Background: The accurate measurement of the femoral anteversion (FA) angle is always a topic of much debate in the orthopedic surgery and radiology research. We aimed to explore a new FA measurement method to acqui... Background: The accurate measurement of the femoral anteversion (FA) angle is always a topic of much debate in the orthopedic surgery and radiology research. We aimed to explore a new FA measurement method to acquire accurate results without radiation damage using piglet model. Methods: A total of thirty piglets were assigned to two groups based on the age. Bilateral femora were imaged with 3.0-T magnetic resonance (MR) and 64-slice computed tomography (CT) examinations on all piglets. FA was measured on MR-three-dimensional (3D) postprocessing software with a four-step method: initial validation of the femoral condylar axis, validation of the condylar plane, validation of the femoral neck axis, and line-plane angle measurement of FA. After MR and CT examinations, all piglets were sacrificed and their degree of FA was measured using their excised, dried femora. MR, CT, and dried-femur measurement results were analyzed statistically; M R and CT measurements were compared for accuracy against each other and against the gold standard dried femur measurement. Results: In both groups, the mean FA value measured by MR was lower than that measured by CT. A statistically significant difference was observed between CT- and dried-femur measurements but not between MR- and dried-femur measurements. A higher correlation (0.783 vs. 0.408) and a higher consistency (0.863 vs. 0.578) with dried-femur measurement results were seen for MR measurements than CT measurements in the 1 -week age group. However, in the 8-week age group, similar correlations (0.707 vs. 0.669) and consistencies (0.864 vs. 0.82 l ) were observed. Conclusions: Noninvasive MR-3D-Cube reconstruction was able to accurately measure FA in piglets. Particularly in the 1-week age group with a larger proportion of cartilaginous structures, the correlation and consistency between MR- and dried-femur measurement results were higher than those between CT- and dried-femur measurements, suggesting that MR may be a new useful examination tool for FA-related diseases in children. 展开更多
关键词 Femoral Anteversion HIP Magnetic Resonance Imaging PIGLET Three-dimensional Fast Spin echo Cube
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部