BACKGROUND: The accurate measurements of various data of the bone diameters of foramen ovale of living person can change the methods of puncturing trigeminal gasserian ganglion via foramen ovale for treating trifacia...BACKGROUND: The accurate measurements of various data of the bone diameters of foramen ovale of living person can change the methods of puncturing trigeminal gasserian ganglion via foramen ovale for treating trifacial neuralgia from the experience of puncture operator only to puncture by taking the objective data of measurement as the evidence, which is good for improving the accuracy of puncturing trigeminal ganglion and reducing side effects. OBJECTIVE : To observe the forms of foramen ovales in healthy adults displayed by volume rendering and multi-planar reconstruction after three-dimensional spiral CT thin-slice scan of skull base, and measure the longitudinal diameter and transverse diameter. DESIGN : A repetitive observation and measurement SETTINGS : Department of Neurosurgery and Department of Medical Imaging, Foshan Hospital of Traditional Chinese Medicine. PARTICIPANTS: Fifty healthy adults (100 sides), who were examined with three-dimensional spiral CT scan, were randomly selected from the Department of Medical Imaging, Foshan Hospital of Traditional Chinese Medicine from January 2005 to January 2006, including 26 males and 24 females, aged 25-68 years with an average of 48 years old. They were all informed and agreed with the examination. METHODS : The subjects were examined with the Philips 16-slice spiral CT-Mx 8000 IDT CT apparatus (Philips Company, Holland), the scanning ranged from 2 cm below the canthomeatal line to the level of suprasellar cistem. The width of collimator was 0.75 mm, pitch was 0.663; tube current was 350 mA, voltage was 120 kV, resolution was 512×512 matrix; slice thickness of reconstruction was 1 mm, and interval was 0.5 mm. After the three-dimensional spiral CT thin-slice scan of skull base, the image post-processing techniques including volume rendering and multi-planar reconstruction were applied to observe the forms of foramen ovales, and measure the size, longitudinal diameter and transverse diameter of the foramen ovales. The figures of the foramen ovales were drawn with mouse along the boundary of bone porous margin and soft tissue. According to the indications, the diameters were measured with computer to observe the forms of foramen ovales. MAIN OUTCOME MEASURES : The longitudinal diameter, transverse diameter and form of foramen ovales were observed. RESULTS: All the 50 healthy adults (100 sides) were involved in the analysis of results. (1) It was observed in the volume rendering images that foramen ovales had four forms of oval shape (77 sides), kidney shape (12 sides), round shape (7 sides), ribbon shape (4 sides). (2) The longitudinal diameters of left and right foramen ovales were (7.67±1.32) and (7.98±1.45) mm, and the transverse diameters were (4.04±0.83), (4.09±1.07) mm; There was no obvious difference between left and right longitudinal diameters (t = 1.63, P = 0.11 ), and left and right transverse diameters were close (t = 0.45, P= 0.65). CONCLUSION : The non-invasive techniques of volume rendering and multi-planar reconstruction after three-dimensional spiral CT thin-slice scan can clearly display the formand size of foramen ovale in healthy adults.展开更多
BACKGROUND: Surgeons are always concerned about the localization of pancreatic functioning islet cell tumor. If the tumor is accurately localized before operation, resection of the pancreatic body and tail without int...BACKGROUND: Surgeons are always concerned about the localization of pancreatic functioning islet cell tumor. If the tumor is accurately localized before operation, resection of the pancreatic body and tail without intention can be avoided. The purpose of this study was to evaluate spiral CT localization of pancreatic functioning islet cell tumors and CT techniques. METHODS: CT manifestations in 6 patients with clinically and pathologically proved pancreatic functioning islet cell tumors ware analyzed retrospectively. RESULTS: In 4 patients with insulinomas and 2 patients with glucagonomas, 5 were localized accurately by CT be- fore surgery and 1 was detected retrospectively. The en- hancement of tumors was greater than that of normal pan- creas in arterial phase and pancreatic parenchymal phase. Four patients showed mild high-density and 2, iso-density in the portal venous phase. CONCLUSION: Spiral CT multi-phase enhanced scan with 1.5 ml/kg contrast agent and 2-5 mm slice width can loca- lize functioning islet cell tumors accurately.展开更多
Objectives: To evaluate the specific manifestations of pancreatic carcinoma on spiral multi-phase CT and its resectability before operation. Methods: Ninety-seven patients were confirmed oper- atively and pathological...Objectives: To evaluate the specific manifestations of pancreatic carcinoma on spiral multi-phase CT and its resectability before operation. Methods: Ninety-seven patients were confirmed oper- atively and pathologically. Enhanced CT scan was performed with intravenous injection bolus of ap- proximately 75-120 ml (1-1.5 ml/kg body weight) contrast medium at a rate of 2.5-3 ml/s. In 68 pa- tients receiving dual-phase scan, the delayed scan time of arterial and venous phases was 18-20 s and 60-70 s, respectively, and in 29 patients receiving three-phase scan, the delayed scan time of arterial, pancreatic and portal venous phases was 18 s, 40 s and 75 s, respectively, with a slice of 3-5 mm thick- ness, a pitch of 1-1.5, and a reconstruction interval of 2.5-4.8 mm. Results: Positive and negative predictive values of un- resectable tumors were 97.65% and 75.86%, respec- tively. The sensitivity and accuracy were 90.67% and 90. 72%, respectively. Positive predictive values of dual-phase and three-phase were 95.83% and 100%, respectively; negative predictive values were 75% and 77.78%, respectively. Conclusions: Spiral multi-phase CT is superior in re- vealing the involvement of peripancreatic vessels, the invasion of the neighboring organs, the size, shape and range of carcinoma, and the metastasis of liver and lymph node. The predictability of resection is obviously increased for patients with pancreatic car- cinoma.展开更多
Objectives: To evaluate the value of the arterial phase(AP) of biphase enhanced spiral CT(SCT) in the di-agnosis of small HCC and to investigate the criteria,initial time, ending time and duration of AP.Methods: From ...Objectives: To evaluate the value of the arterial phase(AP) of biphase enhanced spiral CT(SCT) in the di-agnosis of small HCC and to investigate the criteria,initial time, ending time and duration of AP.Methods: From May 1995 to March 1999, patients withsmall HCC proved surgically and pathologically in-cluding 49 patients (n=53) in group A, 148 (n=186) ingroup B and 52 (n=52) in group C were collected.Biphase dynamic enhanced SCT scans were performedin all patients of the three groups and additional sin-gle-level dynamic scans only done in the group C. Thedetectability, diagnostic accuracy of lesions and en-hancement of the lesions in AP were analyzed statisti-cally. In addition, the initial time, ending time andduration of AP were measured.Results: The results of the group A showed the de-tectability of small HCC was 88.68% in AP and90.57% in both phases, higher than those by ultra-sound. Markedly enhanced lesions in AP accounted for76% and 78% in the groups B and C respectively. Theinitial time, ending time and duration of AP measuredon single-level dynamic scans were 16.9s, 39.6s and22.7s on average respectively.Conclusions: The biphase dynamic SCT especially itsarterial phase appears to be very valuable in diagnosingsmall HCCs. In light of short duration of AP, under-standing and strict control of AP is obviously impera-tive.展开更多
Objective: To compare and analyze the image quality and radiation dose of three scanning modes of dual-source CT coronary artery retrospectively, and to discuss the application value of TurboFlash coarse pitch scannin...Objective: To compare and analyze the image quality and radiation dose of three scanning modes of dual-source CT coronary artery retrospectively, and to discuss the application value of TurboFlash coarse pitch scanning mode. Methods: The imaging data of 100 patients who underwent CT coronary angiography (CCTA) using Siemens force CT retrospective gated triggering spiral scan (RES-SPIRAL), adaptive prospective gated triggering sequence scan (SEQ) and prospective coarse pitch scan (TurboFlash) retrospectively was collected. The image quality was evaluated by objective and subjective methods. The effective radiation dose of patients was compared and analyzed, and the indications of the three scanning modes were analyzed. The application value of dual-source CT TurboFlash coarse pitch scanning in coronary artery imaging was evaluated. Results: The results showed that the left main coronary artery, the right coronary artery and their tertiary branches could be clearly displayed in the three groups of images: the left anterior descending branch, the left circumflex branch, and their three-level branches. There was no statistical difference in subjective image quality among the three groups of pictures (P > 0.05). There was no statistical difference in objective evaluation indexes, such as CT value, SNR, CNR and Noise among the three groups (P > 0.05). The patient radiation dose results showed that the effective radiation dose ED of RES-SPIRA scan was (9.22 ± 1.33) mSv. The dose of SEQ was (2.88 ± 2.47) mSv, and the dose of TurboFlash was (0.51 ± 0.16) mSv. There was significant difference in comparison of the three groups (P 0.05). RES-spiral scanning had the highest radiation dose and TurboFlash coarse pitch scanning (TurboFlash) had the lowest radiation dose. Conclusion: TurboFlash coarse pitch scanning is low in dosage, fast in speed and wide in adaptability. It is especially suitable for the elderly, children, coma and other patients who cannot cooperate with breath-holding examination, as well as for the screening and examination of coronary artery diseases in asymptomatic population. Undoubtedly, it is a worthy method of heart coronary artery examination.展开更多
基金a grant fromTackle Key Problems in Sci-ence and Technology of FoshanCity, No. 200505075
文摘BACKGROUND: The accurate measurements of various data of the bone diameters of foramen ovale of living person can change the methods of puncturing trigeminal gasserian ganglion via foramen ovale for treating trifacial neuralgia from the experience of puncture operator only to puncture by taking the objective data of measurement as the evidence, which is good for improving the accuracy of puncturing trigeminal ganglion and reducing side effects. OBJECTIVE : To observe the forms of foramen ovales in healthy adults displayed by volume rendering and multi-planar reconstruction after three-dimensional spiral CT thin-slice scan of skull base, and measure the longitudinal diameter and transverse diameter. DESIGN : A repetitive observation and measurement SETTINGS : Department of Neurosurgery and Department of Medical Imaging, Foshan Hospital of Traditional Chinese Medicine. PARTICIPANTS: Fifty healthy adults (100 sides), who were examined with three-dimensional spiral CT scan, were randomly selected from the Department of Medical Imaging, Foshan Hospital of Traditional Chinese Medicine from January 2005 to January 2006, including 26 males and 24 females, aged 25-68 years with an average of 48 years old. They were all informed and agreed with the examination. METHODS : The subjects were examined with the Philips 16-slice spiral CT-Mx 8000 IDT CT apparatus (Philips Company, Holland), the scanning ranged from 2 cm below the canthomeatal line to the level of suprasellar cistem. The width of collimator was 0.75 mm, pitch was 0.663; tube current was 350 mA, voltage was 120 kV, resolution was 512×512 matrix; slice thickness of reconstruction was 1 mm, and interval was 0.5 mm. After the three-dimensional spiral CT thin-slice scan of skull base, the image post-processing techniques including volume rendering and multi-planar reconstruction were applied to observe the forms of foramen ovales, and measure the size, longitudinal diameter and transverse diameter of the foramen ovales. The figures of the foramen ovales were drawn with mouse along the boundary of bone porous margin and soft tissue. According to the indications, the diameters were measured with computer to observe the forms of foramen ovales. MAIN OUTCOME MEASURES : The longitudinal diameter, transverse diameter and form of foramen ovales were observed. RESULTS: All the 50 healthy adults (100 sides) were involved in the analysis of results. (1) It was observed in the volume rendering images that foramen ovales had four forms of oval shape (77 sides), kidney shape (12 sides), round shape (7 sides), ribbon shape (4 sides). (2) The longitudinal diameters of left and right foramen ovales were (7.67±1.32) and (7.98±1.45) mm, and the transverse diameters were (4.04±0.83), (4.09±1.07) mm; There was no obvious difference between left and right longitudinal diameters (t = 1.63, P = 0.11 ), and left and right transverse diameters were close (t = 0.45, P= 0.65). CONCLUSION : The non-invasive techniques of volume rendering and multi-planar reconstruction after three-dimensional spiral CT thin-slice scan can clearly display the formand size of foramen ovale in healthy adults.
文摘BACKGROUND: Surgeons are always concerned about the localization of pancreatic functioning islet cell tumor. If the tumor is accurately localized before operation, resection of the pancreatic body and tail without intention can be avoided. The purpose of this study was to evaluate spiral CT localization of pancreatic functioning islet cell tumors and CT techniques. METHODS: CT manifestations in 6 patients with clinically and pathologically proved pancreatic functioning islet cell tumors ware analyzed retrospectively. RESULTS: In 4 patients with insulinomas and 2 patients with glucagonomas, 5 were localized accurately by CT be- fore surgery and 1 was detected retrospectively. The en- hancement of tumors was greater than that of normal pan- creas in arterial phase and pancreatic parenchymal phase. Four patients showed mild high-density and 2, iso-density in the portal venous phase. CONCLUSION: Spiral CT multi-phase enhanced scan with 1.5 ml/kg contrast agent and 2-5 mm slice width can loca- lize functioning islet cell tumors accurately.
基金This study was supported by the grant from the Program of Social Development Fund of the Jiangsu Provincial Science and Technology Commission (BS97046).
文摘Objectives: To evaluate the specific manifestations of pancreatic carcinoma on spiral multi-phase CT and its resectability before operation. Methods: Ninety-seven patients were confirmed oper- atively and pathologically. Enhanced CT scan was performed with intravenous injection bolus of ap- proximately 75-120 ml (1-1.5 ml/kg body weight) contrast medium at a rate of 2.5-3 ml/s. In 68 pa- tients receiving dual-phase scan, the delayed scan time of arterial and venous phases was 18-20 s and 60-70 s, respectively, and in 29 patients receiving three-phase scan, the delayed scan time of arterial, pancreatic and portal venous phases was 18 s, 40 s and 75 s, respectively, with a slice of 3-5 mm thick- ness, a pitch of 1-1.5, and a reconstruction interval of 2.5-4.8 mm. Results: Positive and negative predictive values of un- resectable tumors were 97.65% and 75.86%, respec- tively. The sensitivity and accuracy were 90.67% and 90. 72%, respectively. Positive predictive values of dual-phase and three-phase were 95.83% and 100%, respectively; negative predictive values were 75% and 77.78%, respectively. Conclusions: Spiral multi-phase CT is superior in re- vealing the involvement of peripancreatic vessels, the invasion of the neighboring organs, the size, shape and range of carcinoma, and the metastasis of liver and lymph node. The predictability of resection is obviously increased for patients with pancreatic car- cinoma.
文摘Objectives: To evaluate the value of the arterial phase(AP) of biphase enhanced spiral CT(SCT) in the di-agnosis of small HCC and to investigate the criteria,initial time, ending time and duration of AP.Methods: From May 1995 to March 1999, patients withsmall HCC proved surgically and pathologically in-cluding 49 patients (n=53) in group A, 148 (n=186) ingroup B and 52 (n=52) in group C were collected.Biphase dynamic enhanced SCT scans were performedin all patients of the three groups and additional sin-gle-level dynamic scans only done in the group C. Thedetectability, diagnostic accuracy of lesions and en-hancement of the lesions in AP were analyzed statisti-cally. In addition, the initial time, ending time andduration of AP were measured.Results: The results of the group A showed the de-tectability of small HCC was 88.68% in AP and90.57% in both phases, higher than those by ultra-sound. Markedly enhanced lesions in AP accounted for76% and 78% in the groups B and C respectively. Theinitial time, ending time and duration of AP measuredon single-level dynamic scans were 16.9s, 39.6s and22.7s on average respectively.Conclusions: The biphase dynamic SCT especially itsarterial phase appears to be very valuable in diagnosingsmall HCCs. In light of short duration of AP, under-standing and strict control of AP is obviously impera-tive.
文摘Objective: To compare and analyze the image quality and radiation dose of three scanning modes of dual-source CT coronary artery retrospectively, and to discuss the application value of TurboFlash coarse pitch scanning mode. Methods: The imaging data of 100 patients who underwent CT coronary angiography (CCTA) using Siemens force CT retrospective gated triggering spiral scan (RES-SPIRAL), adaptive prospective gated triggering sequence scan (SEQ) and prospective coarse pitch scan (TurboFlash) retrospectively was collected. The image quality was evaluated by objective and subjective methods. The effective radiation dose of patients was compared and analyzed, and the indications of the three scanning modes were analyzed. The application value of dual-source CT TurboFlash coarse pitch scanning in coronary artery imaging was evaluated. Results: The results showed that the left main coronary artery, the right coronary artery and their tertiary branches could be clearly displayed in the three groups of images: the left anterior descending branch, the left circumflex branch, and their three-level branches. There was no statistical difference in subjective image quality among the three groups of pictures (P > 0.05). There was no statistical difference in objective evaluation indexes, such as CT value, SNR, CNR and Noise among the three groups (P > 0.05). The patient radiation dose results showed that the effective radiation dose ED of RES-SPIRA scan was (9.22 ± 1.33) mSv. The dose of SEQ was (2.88 ± 2.47) mSv, and the dose of TurboFlash was (0.51 ± 0.16) mSv. There was significant difference in comparison of the three groups (P 0.05). RES-spiral scanning had the highest radiation dose and TurboFlash coarse pitch scanning (TurboFlash) had the lowest radiation dose. Conclusion: TurboFlash coarse pitch scanning is low in dosage, fast in speed and wide in adaptability. It is especially suitable for the elderly, children, coma and other patients who cannot cooperate with breath-holding examination, as well as for the screening and examination of coronary artery diseases in asymptomatic population. Undoubtedly, it is a worthy method of heart coronary artery examination.