期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
A high resolution inversion method for fluid factor with dynamic dryrock V_(P)/V_(S) ratio squared
1
作者 Lin Zhou Jian-Ping Liao +3 位作者 Xing-Ye Liu Pu Wang Ya-Nan Guo Jing-Ye Li 《Petroleum Science》 SCIE EI CSCD 2023年第5期2822-2834,共13页
As an important indicator parameter of fluid identification,fluid factor has always been a concern for scholars.However,when predicting Russell fluid factor or effective pore-fluid bulk modulus,it is necessary to intr... As an important indicator parameter of fluid identification,fluid factor has always been a concern for scholars.However,when predicting Russell fluid factor or effective pore-fluid bulk modulus,it is necessary to introduce a new rock skeleton parameter which is the dry-rock VP/VS ratio squared(DVRS).In the process of fluid factor calculation or inversion,the existing methods take this parameter as a static constant,which has been estimated in advance,and then apply it to the fluid factor calculation and inversion.The fluid identification analysis based on a portion of the Marmousi 2 model and numerical forward modeling test show that,taking the DVRS as a static constant will limit the identification ability of fluid factor and reduce the inversion accuracy.To solve the above problems,we proposed a new method to regard the DVRS as a dynamic variable varying with depth and lithology for the first time,then apply it to fluid factor calculation and inversion.Firstly,the exact Zoeppritz equations are rewritten into a new form containing the fluid factor and DVRS of upper and lower layers.Next,the new equations are applied to the four parameters simultaneous inversion based on the generalized nonlinear inversion(GNI)method.The testing results on a portion of the Marmousi 2 model and field data show that dynamic DVRS can significantly improve the fluid factor identification ability,effectively suppress illusion.Both synthetic and filed data tests also demonstrate that the GNI method based on Bayesian deterministic inversion(BDI)theory can successfully solve the above four parameter simultaneous inversion problem,and taking the dynamic DVRS as a target inversion parameter can effectively improve the inversion accuracy of fluid factor.All these results completely verified the feasibility and effectiveness of the proposed method. 展开更多
关键词 Fluid factor Dry-rock V_(P)/V_(S)ratio squared(DVRS) Dynamic variable Multiple parameters simultaneous inversion Generalized nonlinear inversion(GNI)
下载PDF
Experimental study on the seismic behavior of high strength concrete fi lled double-tube columns 被引量:12
2
作者 Qian Jiaru Li Ningbo +1 位作者 Ji Xiaodong Zhao Zuozhou 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2014年第1期47-57,共11页
To study the seismic behavior of high strength concrete fi lled double-tube(CFDT) columns,each consisting of an external square steel tube and an internal circular steel tube,quasi-static tests on eight CFDT column sp... To study the seismic behavior of high strength concrete fi lled double-tube(CFDT) columns,each consisting of an external square steel tube and an internal circular steel tube,quasi-static tests on eight CFDT column specimens were conducted.The test variables included the width-to-thickness ratio(β1) and the area ratio(β2) of the square steel tube,the wall thickness of the circular steel tube,and the axial force(or the axial force ratio) applied to the CFDT columns.The test results indicate that for CFDT columns with a square steel tube with β1 of 50.1 and 24.5,local buckling of the specimen was found at a drift ratio of 1/150 and 1/50,respectively.The lateral force-displacement hysteretic loops of all specimens were plump and stable.Reducing the width-to-thickness ratio of the square steel tube,increasing its area ratio,or increasing the wall thickness of the internal circular steel tube,led to an increased fl exural strength and deformation capacity of the specimens.Increasing the design value of the axial force ratio from 0.8 to 1.0 may increase the fl exural strength of the specimens,while it may also decrease the ultimate deformation capacity of the specimen with β1 of 50.1. 展开更多
关键词 high strength concrete fi lled double-tube(CFDT)column seismic behavior area ratio of the square steel tube width-to-thickness ratio of the square steel tube axial force ratio quasi-static test
下载PDF
Blind spectrum sensing based on the ratio of mean square to variance 被引量:4
3
作者 Ye Yinghui Lu Guangyue 《The Journal of China Universities of Posts and Telecommunications》 EI CSCD 2016年第1期42-48,共7页
Anderson-Darling (AD) sensing, characteristic function (CF) sensing and order statistic (OS) sensing are three common spectrum sensing (SS) methods based on goodness of fit (GOF) testing. However, AD and OS ... Anderson-Darling (AD) sensing, characteristic function (CF) sensing and order statistic (OS) sensing are three common spectrum sensing (SS) methods based on goodness of fit (GOF) testing. However, AD and OS sensing needs the prior information of noise variance; CF and OS sensing have high computation complexity. To circumvent those difficulties, in this paper, the ratio of the mean square to variance (RM2V) of the samples, after deriving its probability density function (PDF), is employed as a test statistic to detect the availability of the vacant spectrum in the cognitive radio (CR) system. Then a blind SS method based on RM2V is proposed, which is dubbed as RM2V sensing, and its exact theoretical threshold is obtained via the derived PDF of RM2V. The performance of RM2V sensing is evaluated by theoretical analysis and Monte Carlo simulations. Comparing with the conventional energy detection (ED), AD, CF and OS sensing, RM2V sensing, with no need of noise variance, has advantages from the aspect of computation complexity and detection performance. 展开更多
关键词 cognitive radio spectrum sensing goodness of fit testing the ratio of the mean square to variance
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部