期刊文献+
共找到28,982篇文章
< 1 2 250 >
每页显示 20 50 100
基于Tanks4.0.9 d模型的储罐VOCs排放特性定量研究
1
作者 胡志军 王志良 《环境科学与管理》 CAS 2024年第11期61-66,共6页
采用Tanks4.0.9 d模型对储罐VOCs排放特征进行定量研究。结果表明,固定顶罐VOCs排放为静止损失和工作损失,浮顶罐VOCs排放为边缘密封损失、挂壁损失和浮盘配件损失,固定顶罐排放量最大,且是内浮顶罐的75倍;内壁锈蚀程度和密封形式是影... 采用Tanks4.0.9 d模型对储罐VOCs排放特征进行定量研究。结果表明,固定顶罐VOCs排放为静止损失和工作损失,浮顶罐VOCs排放为边缘密封损失、挂壁损失和浮盘配件损失,固定顶罐排放量最大,且是内浮顶罐的75倍;内壁锈蚀程度和密封形式是影响浮顶罐VOCs排放量的主要因素,降低内壁锈蚀程度和二次密封可大幅降低VOCs排放量;罐体颜色是影响固定顶罐VOCs排放量的主要因素,罐体颜色从白色加深至红色时,排放量增加55.31%;环境因素和年周转次数是影响储罐VOCs排放量的次要因素,温度的影响程度更显著;基于此,提出了涵盖“源头减排、过程管控、末端治理”的储罐VOCs减排策略。 展开更多
关键词 储罐 挥发性有机物 排放特性 tanks4.0.9 d模型 定量研究
下载PDF
Dynamic Response of A Group of Cylindrical Storage Tanks with Baffles Considering the Effect of Soil Foundation
2
作者 SUN Ying WANG Jia-dong +3 位作者 HUO Rui-li ZHOU Ding GU Zhen-yuan QIAN Wang-ping 《China Ocean Engineering》 SCIE EI CSCD 2024年第1期129-143,共15页
The sloshing in a group of rigid cylindrical tanks with baffles and on soil foundation under horizontal excitation is studied analytically.The solutions for the velocity potential are derived out by the liquid subdoma... The sloshing in a group of rigid cylindrical tanks with baffles and on soil foundation under horizontal excitation is studied analytically.The solutions for the velocity potential are derived out by the liquid subdomain method.Equivalent models with mass-spring oscillators are established to replace continuous fluid.Combined with the least square technique,Chebyshev polynomials are employed to fit horizontal,rocking and horizontal-rocking coupling impedances of soil,respectively.A lumped parameter model for impedance is presented to describe the effects of soil on tank structures.A mechanical model for the soil-foundation-tank-liquid-baffle system with small amount of calculation and high accuracy is proposed using the substructure technique.The analytical solutions are in comparison with data from reported literature and numerical codes to validate the effectiveness and correctness of the model.Detailed dynamic properties and seismic responses of the soil-tank system are given for the baffle number,size and location as well as soil parameter. 展开更多
关键词 cylindrical tanks multiple annular baffles equivalent analytical model soil−structure interaction subdomain method dynamic response
下载PDF
Theoretical Analysis of Biogas Production from Septic Tanks: The Case of the City of Kinshasa
3
作者 Ngondo Otshwe Josue Lutete Nzau Wilfrid Okolonga Djeli Dieumerci 《Natural Science》 CAS 2023年第4期149-166,共18页
As many think that respect for the environment, is not only a question intended for industrialists but has all the sectors of life, in particular sanitary also. In this regard, our article brings alternative managemen... As many think that respect for the environment, is not only a question intended for industrialists but has all the sectors of life, in particular sanitary also. In this regard, our article brings alternative management of human waste (excrement) to solve the problems that plague our dear beautiful capital, namely: 1) Lack of latrines that meet the standards;2) Emptying of septic tanks directly into the gutters and;3) Water pollution by sewage csompanies. In order to carry out the cartographic analysis of the study area, we used Shapefile data from the OpenStreetMap, Diva-Gis. These different data allowed us, analyzed, to categorize with the software ArArcGIS 0.8.1 to produce different zones according to the cases incurred in the city of Kinshasa. To do this, the analytical method uses the Buswell equation to determine the amount of gas contained in human excrement. Focusing on the analysis of the excrements produced by the population of age superior to 10 years, for 2023, we obtained: 138355.7283 m<sup>3</sup>/day of CH4 (885476.66 kWh/day or 885.476 MWh/day), which, energy can light: 138,355 lamps of 60 to 100 W for six hours or nearly 70,000 lamps of 60 to 100 W for 12 hours. Considering the last one which offers the lowest access rate, i.e. 3% of the district population to these latrines, we have: a) In Tshangu, we produce: 1618.762 <sup>3>/day (10360.07 kWh/day or 10.36 MWh/day) which can light nearly 1600 lamps from 60 to 100 W for six hours or nearly 800 lamps from 60 to 100 W for twelve hours. b) Mont-Amba, we produce 1402.927 <sup>3>/day (8978.73 kWh/day or 8.97 MWh/day) which can light nearly 1400 lamps from 60 to 100 W for six hours or nearly 700 lamps from 60 to 100 W for twelve hours;c) In Lukunga, we produce: 946.35 <sup>3>/day (6056.66 kWh/day or 6.056 MWh/day) which can light nearly 900 lamps from 60 to 100 W for six hours or nearly 450 lamps from 60 to 100 W for twelve hours. d) Funa, we produce: 182.629 <sup>3>/day (1168.83 kWh/day or 1.17 MWh/day) which can light almost 180 lamps from 60 to 100 W for six hours or almost 90 lamps from 60 to 100 W for twelve hours. 展开更多
关键词 BIOGAS Septic tanks EXCREMENT ELECTRICITY KINSHASA
下载PDF
Experimental Investigation on the Effect of Seal Presence on the Behavior of Double-Deck Floating Roofs in Cylindrical Steel Storage Tanks
4
作者 Alireza Doustvandi Mehrzad Tahamouli Roudsari Behnoush Niazi 《Structural Durability & Health Monitoring》 EI 2023年第1期55-70,共16页
Liquid storage,particularly oil and petrochemical products which are considered hazardous liquid,are an important part of the oil industry.Thin-walled vertical cylindrical steel storage tanks are widely used in recent... Liquid storage,particularly oil and petrochemical products which are considered hazardous liquid,are an important part of the oil industry.Thin-walled vertical cylindrical steel storage tanks are widely used in recent years.Due to high sensitivity of these structures in an earthquake and other external excitations may lead to catastrophic consequences.For instance,huge economic losses,environmental damages,and casualities,many studies have been done about these structures.past studies showed that liquid storage tanks,equipped with a floating roof,are potentially vulnerable while subjected to seismic loads and earthquake has been considered as one of the most destructive natural hazards.The reason is that such tanks are made of two separated parts(shell and roof)which each may have its own responses;sometimes causing resonance phenomenon and so that,roof movements,rooffluid interaction,roof-shell interaction,and also the way they are attached should still be investigated.Experimental tests of floating roof’s vertical fluctuation was performed in a full-scale reservoir tank and assessing of the results demonstrated that presence of a seal between floating roof and shell plate can significantly increase damping ratio in liquid sloshing and also suppress the roof`s vertical displacements.In other words,seal can control a floating roof and make it stop moving vertically over few cycles. 展开更多
关键词 Floating roof tanks seal master SLOSHING vertical cylindrical tanks sloshing period damping
下载PDF
Enhanced structural damage behavior of liquid-filled tank by reactive material projectile impact 被引量:1
5
作者 Jianwen Xie Yuanfeng Zheng +4 位作者 Zhenyang Liu Chengzhe Liu Aoxin Liu Pengwan Chen Haifu Wang 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第1期211-229,共19页
A series of ballistic experiments were performed to investigate the damage behavior of high velocity reactive material projectiles(RMPs) impacting liquid-filled tanks,and the corresponding hydrodynamic ram(HRAM) was s... A series of ballistic experiments were performed to investigate the damage behavior of high velocity reactive material projectiles(RMPs) impacting liquid-filled tanks,and the corresponding hydrodynamic ram(HRAM) was studied in detail.PTFE/Al/W RMPs with steel-like and aluminum-like densities were prepared by a pressing/sintering process.The projectiles impacted a liquid-filled steel tank with front aluminum panel at approximately 1250 m/s.The corresponding cavity evolution characteristics and HRAM pressure were recorded by high-speed camera and pressure acquisition system,and further compared to those of steel and aluminum projectiles.Significantly different from the conical cavity formed by the inert metal projectile,the cavity formed by the RMP appeared as an ellipsoid with a conical front.The RMPs were demonstrated to enhance the radial growth velocity of cavity,the global HRAM pressure amplitude and the front panel damage,indicating the enhanced HRAM and structural damage behavior.Furthermore,combining the impact-induced fragmentation and deflagration characteristics,the cavity evolution of RMPs under the combined effect of kinetic energy impact and chemical energy release was analyzed.The mechanism of enhanced HRAM pressure induced by the RMPs was further revealed based on the theoretical model of the initial impact wave and the impulse analysis.Finally,the linear correlation between the deformation-thickness ratio and the non-dimensional impulse for the front panel was obtained and analyzed.It was determined that the enhanced near-field impulse induced by the RMPs was the dominant reason for the enhanced structural damage behavior. 展开更多
关键词 Reactive material projectile Hydrodynamic ram Enhanced structural damage Liquid-filled tank Impact
下载PDF
Corrosion of Basic Refractories for Glass Tanks Using Petrol Coke and Countermeasures
6
作者 XU Linlin LIU Zhao +2 位作者 WANG Jiezeng CHEN Songlin LIU Xijun 《China's Refractories》 CAS 2023年第3期1-5,共5页
Replacing heavy oil with petrol coke can greatly reduce the cost of glass production,but obviously shorten the service life of refractories used in the regenerator checker body of glass tanks.To prolong the service li... Replacing heavy oil with petrol coke can greatly reduce the cost of glass production,but obviously shorten the service life of refractories used in the regenerator checker body of glass tanks.To prolong the service life of the regenerator checker body,the slag chemical composition and alkali-sulfur ratio of glass tanks after using petrol coke and the damage mechanism of the residual magnesia bricks in the regenerator checker body were studied,as well as the corrosion resistance of three magnesia based bricks(direct bonded magnesia chrome bricks,fused rebonded magnesia chrome bricks,and fused rebonded high-purity magnesium aluminate spinel bricks).On this basis,a series of targeted countermeasures were adopted to optimize the configuration of refractories,significantly improving the service life of checker bricks and meeting the requirements of glass industry development. 展开更多
关键词 glass tanks petrol coke ash slag CORROSION alkali-sulfur ratio free alkali free sulfur trioxide
下载PDF
Explosion damage effects of aviation kerosene storage tank under strong ignition
7
作者 Shixiang Song Cheng Wang +1 位作者 Boyang Qiao Gongtian Gu 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第7期27-38,共12页
In order to study the blast damage effects of aviation kerosene storage tanks,the out-field explosion experiments of 8 m3fixed-roof tanks were carried out.The fragments,shock wave and fireball thermal radiation of the... In order to study the blast damage effects of aviation kerosene storage tanks,the out-field explosion experiments of 8 m3fixed-roof tanks were carried out.The fragments,shock wave and fireball thermal radiation of the tank in the presence of bottom oil,half oil and full oil,as well as empty tank,were investigated under internal explosion by various TNT charge contents(1.8 kg,3.5 kg and 6.2 kg).The results showed that the tank roof was the only fragment produced,and the damage forms could be divided into three types.The increase of TNT charge content and oil volume enlarged the deformation of the tank,while the hole ratio presented a trend of increase first and then decrease.The H_r,maxand V_(max)values positively increased as increasing the TNT charge content and oil volume(from empty to half oil),but decreased in full oil.The Pmaxvalues had a progressive increase with the increment of TNT charge content,but not the case with the increase in oil volumes.The development of fireball was divided into three stages:tank roof‘towed'flame,jet flow flame tumbling and rising,and jet flow flame extinguishing.The Dmaxand Hf,maxvalues both increased as increasing TNT charge content and oil volumes.The oscillation phenomenon of fireball temperature was observed in the cooling process.The average temperature of fireball surface was positively correlated with TNT charge content,and negatively correlated with oil volumes. 展开更多
关键词 Aviation kerosene Storage tank Internal explosion Shock wave FIREBALL
下载PDF
Effect of length-width ratio of rounded rectangle aquaculture tank in dual-diagonal-inlet layout on hydrodynamics
8
作者 Meng LI Xiaozhong REN +4 位作者 Shupeng DU Wei SUN Chenxu ZHAO Hangfei LIU Xianying SHI 《Journal of Oceanology and Limnology》 SCIE CAS CSCD 2024年第5期1695-1709,共15页
To adapt to the change of aquaculture workshop site,optimize the shape of aquaculture tanks and improve the utilization rate of breeding space,it is necessary to determine the appropriate length width ratio parameters... To adapt to the change of aquaculture workshop site,optimize the shape of aquaculture tanks and improve the utilization rate of breeding space,it is necessary to determine the appropriate length width ratio parameters of aquaculture tanks.In this paper,computational fluid dynamics(CFD)technology is adopted to study the flow field performance of aquaculture tanks with different L/B ratios(L:the length;B:the width,of aquaculture tank)and different jet direction conditions(lengthways jet and widthways jet).A three-dimensional numerical calculation model of turbulence in rounded rectangle aquaculture tanks in dual-diagonal-inlet layout was established.Jet directions are arranged lengthways and widthways,and the water flow velocity,resistance coefficient change,vorticity,etc.are analyzed under two working conditions.Results show that the flow field performance in aquaculture tank decreases with the increase of the L/B ratio.The flow field performed well when L/B was 1.0-1.3,sharply dropped at 1.4-1.6,and poor at 1.7-1.9.The results provided a theoretical basis for the design and optimization in flow field performance of the industrialized circulating aquaculture tanks. 展开更多
关键词 aquaculture tank length-width ratio computational fluid dynamic hydrodynamic
下载PDF
Rotating tank experiments for the study of geophysical fluid dynamics
9
作者 Changming DONG Xiaojie LU +6 位作者 Yuli LIU Guoqing HAN Minghan FU Qian CAO Yang ZHANG Xu CHEN Yeping YUAN 《Journal of Oceanology and Limnology》 SCIE CAS CSCD 2024年第5期1385-1398,共14页
Geophysical fluid dynamics(GFD)is an interdisciplinary field that studies the large-scale motion of fluids in the natural world.With a wide range of applications such as weather forecasts and climate prediction,GFD em... Geophysical fluid dynamics(GFD)is an interdisciplinary field that studies the large-scale motion of fluids in the natural world.With a wide range of applications such as weather forecasts and climate prediction,GFD employs various research approaches including in-situ observations,satellite measurements,numerical simulations,theoretical analysis,artificial intelligence,and physical model experiments in laboratory.Among these approaches,rotating tank experiments provide a valuable tool for simulating naturally-occurring fluid motions in laboratories.With proportional scaling and proper techniques,scientists can reproduce multi-scale physical processes of stratified fluids in the rotation system,which allows for the simulation of essential characteristics of fluid motions in the atmosphere and oceans.In this review,rotating tanks of various scales in the world are introduced,as these tanks have been actively used to explore fundamental scientific questions in ocean and atmosphere dynamics.To illustrate the GFD experiments,three representative cases are presented to demonstrate the frontier achievements in the the GFD study by using rotating tank experiments:mesoscale eddies in the ocean,convection processes,and plume dynamics.Detailed references for the experimental procedures are provided.Future studies are encouraged to further explore the utilization of rotating tanks with improvements in experimental design and integration of other research methods.This is a promising direction of GFD to help enhance our understanding of the complex nature of fluid motions in the natural world and to address the challenges posed by global environmental changes. 展开更多
关键词 laboratory experiment rotating tank geophysical fluid dynamics(GFD)
下载PDF
Numerical Simulation of the Seismic Response of a Horizontal Storage Tank Based on a SPH-FEM Coupling Method
10
作者 Peilei Yan Endong Guo +1 位作者 HouliWu Liangchao Zhang 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第5期1655-1678,共24页
A coupled numerical calculation method combining smooth particle hydrodynamics(SPH)and the finite element method(FEM)was implemented to investigate the seismic response of horizontal storage tanks.Anumericalmodel of a... A coupled numerical calculation method combining smooth particle hydrodynamics(SPH)and the finite element method(FEM)was implemented to investigate the seismic response of horizontal storage tanks.Anumericalmodel of a horizontal storage tank featuring a free liquid surface under seismic action was constructed using the SPH–FEM coupling method.The stored liquid was discretized using SPH particles,while the tank and supports were discretized using the FEM.The interaction between the stored liquid and the tank was simulated by using the meshless particle contact method.Then,the numerical simulation results were compared and analyzed against seismic simulation shaking table test data to validate the method.Subsequently,a series of numerical models,considering different liquid storage volumes and seismic effects,were constructed to obtain time history data of base shear and top center displacement,which revealed the seismic performance of horizontal storage tanks.Numerical simulation results and experimental data showed good agreement,with an error rate of less than 18.85%.And this conformity signifies the rationality of the SPH-FEM coupling method.The base shear and top center displacement values obtained by the coupled SPH-FEM method were only 53.3% to 69.1% of those calculated by the equivalent mass method employed in the current code.As the stored liquid volume increased,the seismic response of the horizontal storage tank exhibited a gradual upward trend,with the seismic response increasing from 73% to 388% for every 35% increase in stored liquid volume.The maximum von Mises stress of the tank and the supports remained below the steel yield strength during the earthquake.The coupled SPH-FEM method holds certain advantages in studying the seismic problems of tanks with complex structural forms,particularly due to the representation of the flow field distribution during earthquakes by involving reservoir fluid participation. 展开更多
关键词 SPH-FEM coupling method horizontal storage tank seismic response SLOSHING
下载PDF
Numerical simulation of inlet placement on sewage characteristics in the rounded square aquaculture tank with single inlet
11
作者 Xiaozhong REN Yixuan HU +5 位作者 Yinxin ZHOU Shupeng DU Wei SUN Hangfei LIU Chenxu ZHAO Ying LIU 《Journal of Oceanology and Limnology》 SCIE CAS CSCD 2024年第4期1359-1382,共24页
To improve the self-cleaning ability of aquaculture tank and the efficiency of circulating water,physical and numerical experiments were conducted on the influence of inlet structure on sewage discharge in a rounded s... To improve the self-cleaning ability of aquaculture tank and the efficiency of circulating water,physical and numerical experiments were conducted on the influence of inlet structure on sewage discharge in a rounded square aquaculture tank with a single inlet.Based on the physical model of the tank,analysis of how inlet structure adjustment affects sewage discharge efficiency and flow field characteristics was conducted to provide suitable flow field conditions for sinkable solid particle discharge.In addition,an internal flow field simulation was conducted using the RNG k-εturbulence model in hydraulic drive mode.Then a solid-fluid multiphase model was created to investigate how the inlet structure affects sewage collection in the rounded square aquaculture tank with single inlet and outlet.The finding revealed that the impact of inlet structure is considerably affecting sewage collection.The conditions of C/B=0.07-0.11(the ratio of horizontal distance between the center of the inlet pipe and the tank wall(C)to length of the tank(B))andα=25°(αis the angle between the direction of the jet and the tangential direction of the arc angle)resulted in optimal sewage collection,which is similar to the flow field experiment in the rounded square aquaculture tank with single inlet and outlet.An excellent correlation was revealed between sewage collection and fluid circulation stability in the aquaculture tank.The present study provided a reference for design and optimization of circulating aquaculture tanks in aquaculture industry. 展开更多
关键词 rounded square aquaculture tank sewage collection characteristic inlet structure computational fluid dynamic
下载PDF
The prediction of projectile-target intersection for moving tank based on adaptive robust constraint-following control and interval uncertainty analysis
12
作者 Cong Li Xiuye Wang +2 位作者 Yuze Ma Fengjie Xu Guolai Yang 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第1期351-363,共13页
To improve the hit probability of tank at high speed,a prediction method of projectile-target intersection based on adaptive robust constraint-following control and interval uncertainty analysis is proposed.The method... To improve the hit probability of tank at high speed,a prediction method of projectile-target intersection based on adaptive robust constraint-following control and interval uncertainty analysis is proposed.The method proposed provides a novel way to predict the impact point of projectile for moving tank.First,bidirectional stability constraints and stability constraint-following error are constructed using the Udwadia-Kalaba theory,and an adaptive robust constraint-following controller is designed considering uncertainties.Second,the exterior ballistic ordinary differential equation with uncertainties is integrated into the controller,and the pointing control of stability system is extended to the impact-point control of projectile.Third,based on the interval uncertainty analysis method combining Chebyshev polynomial expansion and affine arithmetic,a prediction method of projectile-target intersection is proposed.Finally,the co-simulation experiment is performed by establishing the multi-body system dynamic model of tank and mathematical model of control system.The results demonstrate that the prediction method of projectile-target intersection based on uncertainty analysis can effectively decrease the uncertainties of system,improve the prediction accuracy,and increase the hit probability.The adaptive robust constraint-following control can effectively restrain the uncertainties caused by road excitation and model error. 展开更多
关键词 tank stability control Constraint-following Adaptive robust control Uncertainty analysis Prediction of projectile-target intersection
下载PDF
Modern Corrosion Mapping of Storage Tank Bottoms--Notable Advancements in Critical Zone Coverage,Inspection Efficiency and Data Integrity
13
作者 Andrew J.Simpson Matthew A.Boat 《Journal of Civil Engineering and Architecture》 2024年第3期148-153,共6页
Every day,an NDT(Non-Destructive Testing)report will govern key decisions and inform inspection strategies that could affect the flow of millions of dollars which ultimately affects local environments and potential ri... Every day,an NDT(Non-Destructive Testing)report will govern key decisions and inform inspection strategies that could affect the flow of millions of dollars which ultimately affects local environments and potential risk to life.There is a direct correlation between report quality and equipment capability.The more able the equipment is-in terms of efficient data gathering,signal to noise ratio,positioning,and coverage-the more actionable the report is.This results in optimal maintenance and repair strategies providing the report is clear and well presented.Furthermore,when considering tank floor storage inspection it is essential that asset owners have total confidence in inspection findings and the ensuing reports.Tank floor inspection equipment must not only be efficient and highly capable,but data sets should be traceable and integrity maintained throughout.Corrosion mapping of large surface areas such as storage tank bottoms is an inherently arduous and time-consuming process.MFL(magnetic flux leakage)based tank bottom scanners present a well-established and highly rated method for inspection.There are many benefits of using modern MFL technology to generate actionable reports.Chief among these includes efficiency of coverage while gaining valuable information regarding defect location,severity,surface origin and the extent of coverage.More recent advancements in modern MFL tank bottom scanners afford the ability to scan and record data sets at areas of the tank bottom which were previously classed as dead zones or areas not scanned due to physical restraints.An example of this includes scanning the CZ(critical zone)which is the area close to the annular to shell junction weld.Inclusion of these additional dead zones increases overall inspection coverage,quality and traceability.Inspection of the CZ areas allows engineers to quickly determine the integrity of arguably the most important area of the tank bottom.Herein we discuss notable developments in CZ coverage,inspection efficiency and data integrity that combines to deliver an actionable report.The asset owner can interrogate this report to develop pertinent and accurate maintenance and repair strategies. 展开更多
关键词 Storage tank tank bottom CZ MFL stars CORROSION corrosion-mapping EFFICIENCY COVERAGE paperless reporting data traceability
下载PDF
Smoothed-Particle Hydrodynamics Simulation of Ship Motion and Tank Sloshing under the Effect of Regular Waves
14
作者 Mingming Zhao Jialong Jiao 《Fluid Dynamics & Materials Processing》 EI 2024年第5期1045-1061,共17页
Predicting the response of liquefied natural gas(LNG)contained in vessels subjected to external waves is extremely important to ensure the safety of the transportation process.In this study,the coupled behavior due to... Predicting the response of liquefied natural gas(LNG)contained in vessels subjected to external waves is extremely important to ensure the safety of the transportation process.In this study,the coupled behavior due to ship motion and liquid tank sloshing has been simulated by the Smoothed-Particle Hydrodynamics(SPH)method.Firstly,the sloshing flow in a rectangular tank was simulated and the related loads were analyzed to verify and validate the accuracy of the present SPH solver.Then,a three-dimensional simplified LNG carrier model,including two prismatic liquid tanks and a wave tank,was introduced.Different conditions were examined corresponding to different wave lengths,wave heights,wave heading angles,and tank loading rates.Finally,the effects of liquid tank loading rate on LNG ship motions and sloshing loading were analyzed,thereby showing that the SPH method can effectively provide useful indications for the design of liquid cargo ships. 展开更多
关键词 LNG carrier tank sloshing SEAKEEPING inner and external fluid coupling Smoothed Particle Hydrodynamics(SPH)
下载PDF
Identification of the Diffusion Coefficients of Pollutants ( N O 3 - and Mn2+) through the Walls of Concrete Tank and Vulnerability of the Stored Water Quality
15
作者 Narcisse Malanda Bienvenu Ebata Ndion +2 位作者 Christian Tathy Thibault Mongo Paul Louzolokimbembe 《Engineering(科研)》 2024年第9期246-274,共29页
The populations of urban centers in Congo-Brazzaville have decided to develop various methods of water storage (concrete or masonry underground tanks) for domestic use, due to shortages in the distribution of water th... The populations of urban centers in Congo-Brazzaville have decided to develop various methods of water storage (concrete or masonry underground tanks) for domestic use, due to shortages in the distribution of water through the public network. However, questions remain as to the physico-chemical quality of the water stored in these tanks, when these structures are built in wet and relatively polluted areas. This paper presents a model of pollutant diffusion through the cementitious matrix (concrete) of tank walls simulated at a buried reservoir. The results of the experimental and numerical simulations show that certain concrete parameters, such as porosity, permeability and diffusivity, have a significant influence on the transfer of pollutants through the concrete walls, thus altering the physico-chemical quality of the stored water. The numerical models (1D) used to predict pollutant transfer and the quality of the stored water are consistent with those of the optimal control for identifying the diffusion coefficient. Major ion concentrations appear to be correlated with system porosity and diffusion coefficient. Nevertheless, the identification of the diffusion coefficient from the optimal control method, based on an explicit numerical resolution of a finite volume PDE for the approximation of the experiment, is not consistent with that of the optimal control method. 展开更多
关键词 Buried tank Water CONCRETE Modelling Optimal Control Diffusion Coefficient
下载PDF
基于Tanks 4.0.9d模型的储罐VOCs排放特征定量研究 被引量:2
16
作者 杨悦 徐家洛 +1 位作者 黄银芝 修光利 《石油炼制与化工》 CAS CSCD 北大核心 2020年第12期85-91,共7页
基于美国EPA发布的Tanks 4.0.9d模型,对储罐VOCs的排放特征及影响因素进行定量研究,并分析与实测数据的差异。研究表明:储罐VOCs排放受结构特征、环境因素及操作条件的影响;内浮顶罐VOCs排放量最小,固定顶罐VOCs排放量是内浮顶罐的110.5... 基于美国EPA发布的Tanks 4.0.9d模型,对储罐VOCs的排放特征及影响因素进行定量研究,并分析与实测数据的差异。研究表明:储罐VOCs排放受结构特征、环境因素及操作条件的影响;内浮顶罐VOCs排放量最小,固定顶罐VOCs排放量是内浮顶罐的110.5倍;对罐外壁修补白色的底漆,定时进行水喷淋或设置隔热挡板,罐内壁使用防锈防腐材料涂层;运用LDAR(泄漏检测与修复)技术对储罐及其配件进行定期定量的泄漏排查并及时修复等方式均是减少储罐VOCs排放的措施。实地监测得到的VOCs排放量高于模型计算结果,内浮顶汽油罐实测数据是模型计算结果的3.5倍,实测与模型计算等核算方法均存在局限性,建议相关部门根据我国的实际情况开发相应的计算软件,对核算公式进行优化。 展开更多
关键词 储罐 VOCs排放 tanks4.0.9d模型 排放核算方法
下载PDF
Investigation of factors affecting on viscosity reduction of sludge from Iranian crude oil storage tanks 被引量:14
17
作者 Masoumeh Hassanzadeh Leila Tayebi Hedieh Dezfouli 《Petroleum Science》 SCIE CAS CSCD 2018年第3期634-643,共10页
Crude oil is a kind of water/oil emulsion, which the oil phase consists of organic molecules with different molecular weights such as alkanes, paraffin, asphaltene, and resins. Due to the change in physicochemical con... Crude oil is a kind of water/oil emulsion, which the oil phase consists of organic molecules with different molecular weights such as alkanes, paraffin, asphaltene, and resins. Due to the change in physicochemical conditions during the production, transportation, storage, and refining, heavier molecules can precipitate from crude oil. Thus, viscous sludge formed at the bottom of storage tanks can cause many problems including reduction of storage capacity of tank, oil contamination, corrosion, repair costs, environmental pollution, etc. The reduction of sludge viscosity can be achieved by reduction of its interfacial tension. In this study, different chemical and physical factors, influencing prepared emulsions(made of sludge, water and surfactant), such as surfactants, solvents, temperature, pressure, and mixing conditions were investigated. Results showed that non-ionic surfactants(like bitumen emulsifier), and solvents(such as mixed xylene, AW-400, and AW-402), injection of additives, applying pressure, and mixing operations had a positive effect on reduction of emulsion viscosity. All experiments were carried out with sludge obtained from crude oil storage tanks at Kharg Island,Iran. 展开更多
关键词 SURFACTANT EMULSION SLUDGE Storage tank Crude oil
下载PDF
Seismic assessment of unanchored steel storage tanks by endurance time method 被引量:4
18
作者 M. Alembagheri H.E. Estekanchi 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2011年第4期591-603,共13页
Liquid storage tanks are essential structures that are often located in residential and industrial areas; thus an assessment of their seismic performance is an important engineering issue. In this paper, the seismic r... Liquid storage tanks are essential structures that are often located in residential and industrial areas; thus an assessment of their seismic performance is an important engineering issue. In this paper, the seismic response ofunanchored steel liquid storage tanks is investigated using the endurance time (ET) dynamic analysis procedure and compared to responses obtained for anchored tanks under actual ground motions and intensifying ET records. In most cases, the results from ground motions are properly obtained with negligible differences using ET records. It is observed that uplifting of the tank base, which is closely related to the tank aspect ratio, has the greatest significance in the responses of the tank and can be predicted with reasonable accuracy by using currently available ET records. 展开更多
关键词 steel liquid storage tanks endurance time method seismic assessment intensifying dynamic excitation tank base uplifting
下载PDF
Application of numerical simulation on optimum design of two-dimensional sedimentation tanks in the wastewater treatment plant 被引量:4
19
作者 ZENG Guang-ming,ZHANG Shuo-fu, QIN Xiao-sheng, HUANG Guo-he, LI Jian-bing (Department of Environmental Science and Engineering of Hunan University, Changsha 410082, China.) 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2003年第3期346-350,共5页
The paper establishes the relationship between the settling efficiency and the sizes of the sedimentation tank through the process of numerical simulation, which is taken as one of the constraints to set up a simple o... The paper establishes the relationship between the settling efficiency and the sizes of the sedimentation tank through the process of numerical simulation, which is taken as one of the constraints to set up a simple optimum designing model of sedimentation tank. The feasibility and advantages of this model based on numerical calculation are verified through the application of practical case. 展开更多
关键词 numerical simulation sedimentation tank optimum design
下载PDF
Tank模型在中小河流洪水气象风险预警中的应用 被引量:6
20
作者 旷兰 田茂举 +3 位作者 肖蕾 陈茜茜 海川 葛的霆 《水电能源科学》 北大核心 2023年第2期74-78,共5页
结合蒲河流域的气候条件和洪水特性,利用Tank模型模拟了该流域2019~2020年10次暴雨洪水过程,构建了适用于该流域的概念性暴雨致洪气象风险预警模型,并进行仿真模拟和精度评定。结果表明,改进后的水箱模型能直观地模拟出石角水文站不同... 结合蒲河流域的气候条件和洪水特性,利用Tank模型模拟了该流域2019~2020年10次暴雨洪水过程,构建了适用于该流域的概念性暴雨致洪气象风险预警模型,并进行仿真模拟和精度评定。结果表明,改进后的水箱模型能直观地模拟出石角水文站不同时间尺度、不同基础水位条件下的水位变化过程曲线,能减少面雨量阈值的不确定性,预报精度为乙等;根据模拟结果逐级发布气象风险预警,技巧评分和命中率为100%;平均预警发布时间提前3 h以上,可代入预测降水进一步延长洪水预报预见期。 展开更多
关键词 tank模型 中小河流洪水 气象风险预警 洪水预警
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部