This paper presents the model cavity tune and cold test of an S-band 2MeV on-axis coupling SW accelerator. The measurement of the model cavity's frequency,degree of coupling,Q value and on-axis field distribution ...This paper presents the model cavity tune and cold test of an S-band 2MeV on-axis coupling SW accelerator. The measurement of the model cavity's frequency,degree of coupling,Q value and on-axis field distribution are described in detail.In addition,the results of cavity tune and cold test of the accelerating tube are given.The frequency consistency of the accelerator is within±0.3MHz,the coupling degree in the supersaturation state 1.14,the quality factor of the accelerator 12000±200,and the field distribution ratio 1:2.2:2.All the results observed show that the accelerator satisfies the physics design with microwave debugging.展开更多
文摘This paper presents the model cavity tune and cold test of an S-band 2MeV on-axis coupling SW accelerator. The measurement of the model cavity's frequency,degree of coupling,Q value and on-axis field distribution are described in detail.In addition,the results of cavity tune and cold test of the accelerating tube are given.The frequency consistency of the accelerator is within±0.3MHz,the coupling degree in the supersaturation state 1.14,the quality factor of the accelerator 12000±200,and the field distribution ratio 1:2.2:2.All the results observed show that the accelerator satisfies the physics design with microwave debugging.