This paper proposes a novel control approach for fault-tolerant control of dual three-phase permanent magnet synchronous motor(PMSM) under one-phase open-circuit fault.A modified six-phase static coordinate transforma...This paper proposes a novel control approach for fault-tolerant control of dual three-phase permanent magnet synchronous motor(PMSM) under one-phase open-circuit fault.A modified six-phase static coordinate transformation matrix and an extended rotating coordinate transformation matrix are investigated considering the influence of the fifth harmonic space on fault-tolerant control. These mathematical models are further analyzed in the fundamental space and the fifth harmonic space after the fault and to eliminate the coupling between the d-q axis voltage equation in the fundamental wave space and the d-q axis voltage equation in the fifth harmonic space, a secondary rotation coordinate transformation matrix is proposed. To achieve the purpose of reducing torque ripple, the fault-tolerant control method proposed in this paper not only takes the minimum copper loss as the constraint condition, but also injects the fifth harmonic current. The experimental result of current and torque is used to verify the accuracy of fault-tolerant control.展开更多
For a ring A, an extension ring B, a fixed right A-module M, the endomorphism ring D formed by M, the endomorphism ring E formed by , and the endomorphism ring F formed by HomA (B,M), we present equivalences and duali...For a ring A, an extension ring B, a fixed right A-module M, the endomorphism ring D formed by M, the endomorphism ring E formed by , and the endomorphism ring F formed by HomA (B,M), we present equivalences and dualities between subcategories of B-modules which are finitely cogenerated injective as A-modules and E-modules and F-modules which are finitely generated projective as D-modules.展开更多
Static security assessment(SSA) is an important procedure to ensure the static security of the power system.Researches recently show that cyber-attacks might be a critical hazard to the secure and economic operations ...Static security assessment(SSA) is an important procedure to ensure the static security of the power system.Researches recently show that cyber-attacks might be a critical hazard to the secure and economic operations of the power system. In this paper, the influences of false data injection attack(FDIA) on the power system SSA are studied. FDIA is a major kind of cyber-attacks that can inject malicious data into meters, cause false state estimation results, and evade being detected by bad data detection. It is firstly shown that the SSA results could be manipulated by launching a successful FDIA, which can lead to incorrect or unnecessary corrective actions. Then,two kinds of targeted scenarios are proposed, i.e., fake secure signal attack and fake insecure signal attack. The former attack will deceive the system operator to believe that the system operates in a secure condition when it is actually not. The latter attack will deceive the system operator to make corrective actions, such as generator rescheduling, load shedding, etc. when it is unnecessary and costly. The implementation of the proposed analysis is validated with the IEEE-39 benchmark system.展开更多
The reverse snapback phenomena (RSP) on I-V characteristics of static induction thyristors (SITH) are physically researched. The I-V curves of the power SITH exhibit reverse snapback phenomena, and even turn to th...The reverse snapback phenomena (RSP) on I-V characteristics of static induction thyristors (SITH) are physically researched. The I-V curves of the power SITH exhibit reverse snapback phenomena, and even turn to the conducting-state,when the anode voltage in the forward blocking-state is increased to a critical value. The RSP I-V characteristics of the power SITH are analyzed in terms of operating mechanism, double carrier injection effect, space charge effect, electron-hole plasma in the channel, and the variation in carrier lifetime. The reverse snapback mechanism is theoretically pro- posed and the mathematical expressions to calculate the voltage and current values at the snapback point are presented. The computing results are compared with the experiment values.展开更多
基金supported by the National Natural Science Foundation of China under Grant 61603263。
文摘This paper proposes a novel control approach for fault-tolerant control of dual three-phase permanent magnet synchronous motor(PMSM) under one-phase open-circuit fault.A modified six-phase static coordinate transformation matrix and an extended rotating coordinate transformation matrix are investigated considering the influence of the fifth harmonic space on fault-tolerant control. These mathematical models are further analyzed in the fundamental space and the fifth harmonic space after the fault and to eliminate the coupling between the d-q axis voltage equation in the fundamental wave space and the d-q axis voltage equation in the fifth harmonic space, a secondary rotation coordinate transformation matrix is proposed. To achieve the purpose of reducing torque ripple, the fault-tolerant control method proposed in this paper not only takes the minimum copper loss as the constraint condition, but also injects the fifth harmonic current. The experimental result of current and torque is used to verify the accuracy of fault-tolerant control.
文摘For a ring A, an extension ring B, a fixed right A-module M, the endomorphism ring D formed by M, the endomorphism ring E formed by , and the endomorphism ring F formed by HomA (B,M), we present equivalences and dualities between subcategories of B-modules which are finitely cogenerated injective as A-modules and E-modules and F-modules which are finitely generated projective as D-modules.
基金supported by the Hong Kong Polytechnic University(1-YW1Q)
文摘Static security assessment(SSA) is an important procedure to ensure the static security of the power system.Researches recently show that cyber-attacks might be a critical hazard to the secure and economic operations of the power system. In this paper, the influences of false data injection attack(FDIA) on the power system SSA are studied. FDIA is a major kind of cyber-attacks that can inject malicious data into meters, cause false state estimation results, and evade being detected by bad data detection. It is firstly shown that the SSA results could be manipulated by launching a successful FDIA, which can lead to incorrect or unnecessary corrective actions. Then,two kinds of targeted scenarios are proposed, i.e., fake secure signal attack and fake insecure signal attack. The former attack will deceive the system operator to believe that the system operates in a secure condition when it is actually not. The latter attack will deceive the system operator to make corrective actions, such as generator rescheduling, load shedding, etc. when it is unnecessary and costly. The implementation of the proposed analysis is validated with the IEEE-39 benchmark system.
文摘The reverse snapback phenomena (RSP) on I-V characteristics of static induction thyristors (SITH) are physically researched. The I-V curves of the power SITH exhibit reverse snapback phenomena, and even turn to the conducting-state,when the anode voltage in the forward blocking-state is increased to a critical value. The RSP I-V characteristics of the power SITH are analyzed in terms of operating mechanism, double carrier injection effect, space charge effect, electron-hole plasma in the channel, and the variation in carrier lifetime. The reverse snapback mechanism is theoretically pro- posed and the mathematical expressions to calculate the voltage and current values at the snapback point are presented. The computing results are compared with the experiment values.