期刊文献+
共找到9,793篇文章
< 1 2 250 >
每页显示 20 50 100
Impact of well placement and flow rate on production efficiency and stress field in the fractured geothermal reservoirs
1
作者 Xinghui Wu Meifeng Cai +3 位作者 Xu Wu Ketong Zhang Ziqing Yin Yu Zhu 《Deep Underground Science and Engineering》 2024年第3期358-368,共11页
Geothermal energy has gained wide attention as a renewable alternative for mitigating greenhouse gas emissions.The advancements in enhanced geothermal system technology have enabled the exploitation of previously inac... Geothermal energy has gained wide attention as a renewable alternative for mitigating greenhouse gas emissions.The advancements in enhanced geothermal system technology have enabled the exploitation of previously inaccessible geothermal resources.However,the extraction of geothermal energy from deep reservoirs poses many challenges due to high‐temperature and high‐geostress conditions.These factors can significantly impact the surrounding rock and its fracture formation.A comprehensive understanding of the thermal–hydraulic–mechanical(THM)coupling effect is crucial to the safe and efficient exploitation of geothermal resources.This study presented a THM coupling numerical model for the geothermal reservoir of the Yangbajing geothermal system.This proposed model investigated the geothermal exploitation performance and the stress distribution within the reservoir under various combinations of geothermal wells and mass flow rates.The geothermal system performance was evaluated by the criteria of outlet temperature and geothermal productivity.The results indicate that the longer distance between wells can increase the outlet temperature of production wells and improve extraction efficiency in the short term.In contrast,the shorter distance between wells can reduce the heat exchange area and thus mitigate the impact on the reservoir stress.A larger mass flow rate is conducive to the production capacity enhancement of the geothermal system and,in turn causes a wider range of stress disturbance.These findings provide valuable insights into the optimization of geothermal energy extraction while considering reservoir safety and long‐term sustainability.This study deepens the understanding of the THM coupling effects in geothermal systems and provides an efficient and environmentally friendly strategy for a geothermal energy system. 展开更多
关键词 geothermal exploitation performance geothermal reservoir mass flow rate stress field well placementa
下载PDF
Comparison of the precision of glacier flow rates derived from offset-tracking using Sentinel-2 and Landsat-8/9 imagery
2
作者 YANG Zhibin CHEN Zhuoqi +3 位作者 LI Gang MAO Yanting FENG Xiaoman CHENG Xiao 《Advances in Polar Science》 CSCD 2024年第2期238-251,共14页
Offset-tracking is an essential method for deriving glacier flow rates using optical imagery.Sentinel-2(S2)and Landsat-8/9(L8/9)are popular optical satellites or constellations for polar studies,offering high spatial ... Offset-tracking is an essential method for deriving glacier flow rates using optical imagery.Sentinel-2(S2)and Landsat-8/9(L8/9)are popular optical satellites or constellations for polar studies,offering high spatial resolution with relatively short revisit time,wide swath width,and free accessibility.To evaluate and compare the precision of offset-tracking results yielded with these two kinds of data,in this study S2 and L8/9 imagery observed in Petermann Glacier in Greenland,Karakoram in High-Mountains Asia,and Amery Ice Shelf in the Antarctic are analyzed.Outliers and various systematic error sources in the offset-tracking results including orbital and strip errors were analyzed and eliminated at the pre-process stage.Precision at the off-glacier(bare rock)region was evaluated by presuming that no deformation occurred;then for both glacierized and the off-glacier regions,precision of velocity time series was evaluated based on error propagation theory.The least squares method based on connected components was used to solve flow rates time series based on multi-pair images offset-tracking.The results indicated that S2 achieved slightly higher precision than L8/9 in terms of both single-pair derived displacements and least square solved daily flow rates time series.Generally,the RMSE of daily velocity is 26%lower for S2 than L8/9.Moreover,S2 provided higher temporal resolution for monitoring glacier flow rates. 展开更多
关键词 Sentinel-2 LANDSAT glacier flow rates offset-tracking PRECISION
下载PDF
Flow Rate Measurement of Gravity Infusion Set and Functional Evaluation of Drop Counter: A Pilot Study
3
作者 Rina Sakai Shuichi Tanaka +3 位作者 Kaya Murakami Tomomi Mizuhashi Kazuhiro Yoshida Masanobu Ujihira 《Journal of Biomedical Science and Engineering》 2024年第7期129-135,共7页
Developing a novel drop counter by introducing the Internet of Things concept has been vigorously conducted in recent years. Understanding the newly introduced drop counter’s flow rate control accuracy and flow rate ... Developing a novel drop counter by introducing the Internet of Things concept has been vigorously conducted in recent years. Understanding the newly introduced drop counter’s flow rate control accuracy and flow rate count feature is essential for improving safety in infusion management. This study aimed to verify if the new drop counters could secure accurate flow rate and drip count by conducting actual flow rate measurements using gravimetry and functional evaluation. A drop counter was attached to each drip chamber of the infusion set, and an IV drip was conducted at the 100 ml/h flow rate. The weight of discharged physiological saline was measured to plot trumpet curves. Next, three different types of drop counters were evaluated to determine if they maintained drip count accuracy according to the changes in their position angles. The flow rate errors in all conditions indicated trumpet-like curves, exhibiting an overall error range within ±10% in all observation windows. Although every drop counter successfully detected and measured dripping, it was challenging in some counters to detect dripping when the drip chamber was tilted. In comparing adult and pediatric IV sets, the adult IV set was found to be less likely to detect dripping in the angled position. No significant differences in results were confirmed between high and low flow rates, suggesting that the drop count function would not be affected by the flow rate in the ranges of typical infusion practices. Doppler sensors have a wide range of measurements and high sensitivity;the dripping was detected successfully even when the drip chamber was tilted, probably due to the advantages of these sensors. In contrast, miscounts occurred in those equipped with infrared sensors, which could not detect light intensity changes in tilted positions. Understanding the tendencies in flow rate errors in infusion can be valuable information for infusion management. 展开更多
关键词 Gravity Infusion Set Drop Counter IV Fluids flow rate Trumpet Curves
下载PDF
Secondary steady-state and time-periodic flows from a basic flow with square array of odd number of vortices
4
作者 Zhimin CHEN W.G.PRICE 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2023年第3期447-458,共12页
In a magnetohydrodynamic(MHD)driven fluid cell,a plane non-parallel flow in a square domain satisfying a free-slip boundary condition is examined.The energy dissipation of the flow is controlled by the viscosity and l... In a magnetohydrodynamic(MHD)driven fluid cell,a plane non-parallel flow in a square domain satisfying a free-slip boundary condition is examined.The energy dissipation of the flow is controlled by the viscosity and linear friction.The latter arises from the influence of the Hartmann bottom boundary layer in a three-dimensional(3D)MHD experiment in a square bottomed cell.The basic flow in this fluid system is a square eddy flow exhibiting a network of N~2 vortices rotating alternately in clockwise and anticlockwise directions.When N is odd,the instability of the flow gives rise to secondary steady-state flows and secondary time-periodic flows,exhibiting similar characteristics to those observed when N=3.For this reason,this study focuses on the instability of the square eddy flow of nine vortices.It is shown that there exist eight bi-critical values corresponding to the existence of eight neutral eigenfunction spaces.Especially,there exist non-real neutral eigenfunctions,which produce secondary time-periodic flows exhibiting vortices merging in an oscillatory manner.This Hopf bifurcation phenomenon has not been observed in earlier investigations. 展开更多
关键词 two-dimensional(2D)Navier-Stokes equation non-parallel square vortex flow primary bifurcation secondary steady-state flow secondary time-periodic flow
下载PDF
Direct Calculation of Unsteady-State Weymouth Equations for Gas Volumetric Flow Rate with Different Friction Factors in Horizontal and Inclined Pipes 被引量:3
5
作者 Abayomi O. Olatunde Tunde A. Adeosun +4 位作者 Mohammed A. Usman Olabisi M. Odunlami Moses A. Olowofoyeku Testy E. Ekakitie Atanda M. Mohammed 《Engineering(科研)》 2012年第4期202-209,共8页
Direct calculations of unsteady-state Weymouth equations for gas volumetric flow rate occur more frequently in the design and operation analysis of natural gas systems. Most of the existing gas pipelines design proced... Direct calculations of unsteady-state Weymouth equations for gas volumetric flow rate occur more frequently in the design and operation analysis of natural gas systems. Most of the existing gas pipelines design procedures are based on a particular friction factor and steady-state flow analysis. This paper examined the behavior of different friction factors and the need to develop model analysis capable of calculating unsteady-state gas flow rate in horizontal and inclined pipes. The results show different variation in flow rate with Panhandle A and Panhandle B attaining stability in accurate time with initial unsteadiness at the instance of flow. Chen and Jain friction factors have opposition to flow with high flow rate: The prediction also reveals that Colebrook-White degenerated to Nikuradse friction factor at high Reynolds number. The horizontal and inclined flow equations are considerably enhanced on the usage of different friction factors with the aid of Matlab to handle these calculations. 展开更多
关键词 Unsteady-state flow rate Friction Factor Stability VARIATIONS UNSTEADINESS
下载PDF
Impact of Typical Steady-state Conditions and Transient Conditions on Flow Ripple and Its Test Accuracy for Axial Piston Pump 被引量:14
6
作者 XU Bing HU Min ZHANG Junhui 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2015年第5期1012-1022,共11页
The current research about the flow ripple of axial piston pump mainly focuses on the effect of the structure of parts on the flow ripple. Therein, the structure of parts are usually designed and optimized at rated wo... The current research about the flow ripple of axial piston pump mainly focuses on the effect of the structure of parts on the flow ripple. Therein, the structure of parts are usually designed and optimized at rated working conditions. However, the pump usually has to work in large-scale and time-variant working conditions. Therefore, the flow ripple characteristics of pump and analysis for its test accuracy with respect to variant steady-state conditions and transient conditions in a wide range of operating parameters are focused in this paper. First, a simulation model has been constructed, which takes the kinematics of oil film within friction pairs into account for higher accuracy. Afterwards, a test bed which adopts Secondary Source Method is built to verify the model. The simulation and tests results show that the angular position of the piston, corresponding to the position where the peak flow ripple is produced, varies with the different pressure. The pulsating amplitude and pulsation rate of flow ripple increase with the rise of pressure and the variation rate of pressure. For the pump working at a constant speed, the flow pulsation rate decreases dramatically with the increasing speed when the speed is less than 27.78% of the maximum speed, subsequently presents a small decrease tendency with the speed further increasing. With the rise of the variation rate of speed, the pulsating amplitude and pulsation rate of flow ripple increase. As the swash plate angle augments, the pulsating amplitude of flow ripple increases, nevertheless the flow pulsation rate decreases. In contrast with the effect of the variation of pressure, the test accuracy of flow ripple is more sensitive to the variation of speed. It makes the test accuracy above 96.20% available for the pulsating amplitude of pressure deviating within a range of ~6% from the mean pressure. However, with a variation of speed deviating within a range of ±2% from the mean speed, the attainable test accuracy of flow ripple is above 93.07%. The model constructed in this research proposes a method to determine the flow ripple characteristics of pump and its attainable test accuracy under the large-scale and time-variant working conditions. Meanwhile, a discussion about the variation of flow ripple and its obtainable test accuracy with the conditions of the pump working in wide operating ranges is given as well. 展开更多
关键词 axial piston pump flow ripple test accuracy steady-state condition transient condition wide operating ranges
下载PDF
System Energy and Efficiency Analysis of 12.5 W VRFB with Different Flow Rates
7
作者 Kehuan Xie Longhai Yu Chuanchang Li 《Energy Engineering》 EI 2023年第12期2903-2915,共13页
Vanadium redox flow battery(VRFB)is considered one of the most potential large-scale energy storage technolo-gies in the future,and its electrolyte flow rate is an important factor affecting the performance of VRFB.To... Vanadium redox flow battery(VRFB)is considered one of the most potential large-scale energy storage technolo-gies in the future,and its electrolyte flow rate is an important factor affecting the performance of VRFB.To study the effect of electrolyte flow rate on the performance of VRFB,the hydrodynamic model is established and a VRFB system is developed.The results show that under constant current density,with the increase of electrolyte flow rate,not only the coulombic efficiency,energy efficiency,and voltage efficiency will increase,but also the capacity and energy discharged by VRFB will also increase.But on the other hand,as the flow rate increases,the power of the pump also increases,resulting in a decrease in system efficiency.The energy discharged by the system does not increase with the increase in flow rate.Considering the balance between efficiency and pump power loss,it is experimentally proved that 120 mL·min-1 is the optimal working flow rate of the VRFB system,which can maximize the battery performance and discharge more energy. 展开更多
关键词 Vanadium redox flow battery flow rate system energy EFFICIENCY
下载PDF
Relation of tea ingestion to salivary redox and flow rate in healthy subjects
8
作者 Pik Han Chong Qiaojuan He +4 位作者 Suyun Zhang Jianwu Zhou Pingfan Rao Min Zhang Lijing Ke 《Food Science and Human Wellness》 SCIE CSCD 2023年第6期2336-2343,共8页
The biochemistry of human saliva can be altered by food intake.The benefits of tea drinking were extensively studied but the influence of tea ingestion on human saliva has not been revealed.The work aimed to investiga... The biochemistry of human saliva can be altered by food intake.The benefits of tea drinking were extensively studied but the influence of tea ingestion on human saliva has not been revealed.The work aimed to investigate the immediate and delayed effect of vine tea,oolong tea and black tea intake on certain salivary biochemistry and flow rate.The saliva samples of healthy subjects were collected before,after and 30 min after tea ingestion.The chemical compositions and antioxidant capacity of tea samples were analyzed to correlate with salivary parameters.Principal component analysis indicated that the effects of vine tea consumption were dominated by increasing salivary flow rate(SFR),production rate of total protein(TPC),thiol(SH),malondialdehyde,catalase activity and antioxidant capacity(FRAP)in saliva.The antioxidant profile of studied tea samples(FRAP,polyphenols,flavonoids)was positively correlated with salivary SFR,TPC,SH and FRAP but negatively correlated with salivary uric acid concentration in saliva. 展开更多
关键词 Black tea flow rate Oolong tea Salivary redox status Vine tea
下载PDF
Pedestrian flow through exit:Study focused on evacuation pattern
9
作者 张博思 余志红 +2 位作者 孙柏林 郭紫钰 陈默 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期755-764,共10页
Experiments are conducted on the evacuation rate of pedestrians through exits with queued evacuation pattern and random evacuation pattern. The experimental results show that the flow rate of pedestrians is larger wit... Experiments are conducted on the evacuation rate of pedestrians through exits with queued evacuation pattern and random evacuation pattern. The experimental results show that the flow rate of pedestrians is larger with the random evacuation pattern than with the queued evacuation pattern. Therefore, the exit width calculated based on the minimum evacuation clear width for every 100 persons, which is on the assumption that the pedestrians pass through the exit in one queue or several queues, is conservative. The number of people crossing the exit simultaneously is greater in the random evacuation experiments than in the queued evacuation experiments, and the time interval between the front row and rear row of people is shortened in large-exit conditions when pedestrians evacuate randomly. The difference between the flow rate with a queued evacuation pattern and the flow rate with a random evacuation pattern is related to the surplus width of the exit, which is greater than the total width of all accommodated people streams. Two dimensionless quantities are defined to explore this relationship. It is found that the difference in flow rate between the two evacuation patterns is stable at a low level when the surplus width of the exit is no more than 45% of the width of a single pedestrian stream. There is a great difference between the flow rate with the queued evacuation pattern and the flow rate with the random evacuation pattern in a scenario with a larger surplus width of the exit. Meanwhile, the pedestrians crowd extraordinarily at the exit in these conditions as well, since the number of pedestrians who want to evacuate through exit simultaneously greatly exceeds the accommodated level. Therefore, the surplus width of exit should be limited especially in the narrow exit condition, and the relationship between the two dimensionless quantities mentioned above could provide the basis to some extent. 展开更多
关键词 EVACUATION exit width flow rate queued evacuation pattern random evacuation pattern
下载PDF
Rate transient analysis methods for water-producing gas wells in tight reservoirs with mobile water
10
作者 Qingyan Yu Ying Jia +2 位作者 Pengcheng Liu Xiangyang Hu Shengye Hao 《Energy Geoscience》 EI 2024年第1期311-320,共10页
Tight gas reservoirs with mobile water exhibit multi-phase flow and high stress sensitivity.Accurately analyzing the reservoir and well parameters using conventional single-phase rate transient analysis methods proves... Tight gas reservoirs with mobile water exhibit multi-phase flow and high stress sensitivity.Accurately analyzing the reservoir and well parameters using conventional single-phase rate transient analysis methods proves challenging.This study introduces novel rate transient analysis methods incorporating evaluation processes based on the conventional flowing material balance method and the Blasingame type-curve method to examine fractured gas wells producing water.By positing a gas-water two-phase equivalent homogenous phase that considers characteristics of mobile water,gas,and high stress sensitivity,the conventional single-phase rate transient analysis methods can be applied by integrating the phase's characteristics and defining the phase's normalized parameters and material balance pseudotime.The rate transient analysis methods based on the equivalent homogenous phase can be used to quantitatively assess the parameters of wells and gas reservoirs,such as original gas-in-place,fracture half-length,reservoir permeability,and well drainage radius.This facilitates the analysis of production dynamics of fractured wells and well-controlled areas,subsequently aiding in locating residual gas and guiding the configuration of well patterns.The specific evaluation processes are detailed.Additionally,a numerical simulation mechanism model was constructed to verify the reliability of the developed methods.The methods introduced have been successfully implemented in field water-producing gas wells within tight gas reservoirs containing mobile water. 展开更多
关键词 Gas reservoirs with mobile water Gas-water two phase flow High stress sensitivity Equivalent homogenous phase rate transient analysis
下载PDF
Steady-State Radial Flow Modeling through the Production Well in the Confined Aquifer of Monzoungoudo,Benin
11
作者 Francois de Paule Codo Babilas Hountondji Martin P.Aina 《Open Journal of Fluid Dynamics》 2019年第2期107-118,共12页
This study aims to develop a mathematical analysis for one-dimensional modeling of a radial flow through a production well drilled in a confined aquifer, in the case of steady-state flow conditions. An analytical solu... This study aims to develop a mathematical analysis for one-dimensional modeling of a radial flow through a production well drilled in a confined aquifer, in the case of steady-state flow conditions. An analytical solution has derived from that expression for estimation of drawdowns according to different flowrates. Through that process, the evaluation of static pressure, the calculation of hydraulic charge due to the waterflow through the well is evaluated, the drawdowns curves are drawn and at last, the obtained curves are analyzed. The curves obtained for the different flow rates have an asymptotic direction, the axis of the hydraulic charges. The variation of the hydraulic charge depends on the radial distance for different flow rates. The P point, is a common point of all curves obtained for different production flowrates in the well. This point is where the well production flowrate is optimum for the optimal hydraulic charge. 展开更多
关键词 Confined Aquifer Production Well Radial flow steady-state flow DRAWDOWN Cone of Depression
下载PDF
MODFLOW-CFPv2 模型在岩溶隧道突涌水及对地下水环境影响中的应用: 以云南鹤庆锰矿沟岩溶水系统为例
12
作者 肖竞 万军伟 +4 位作者 成建梅 李仲夏 余杭 李槿鸿 袁帅 《地质科技通报》 CAS CSCD 北大核心 2024年第3期301-310,共10页
滇中地区构造复杂、岩溶发育,隧洞突涌水及泉流量衰减是隧洞施工过程中最棘手的问题之一。锰矿沟岩溶水系统岩溶管道化程度高,岩溶裂隙与岩溶管道2种含水介质差异显著。采用MODFLOW-CFPv2双重介质数值模型对锰矿沟岩溶水系统展开数值模... 滇中地区构造复杂、岩溶发育,隧洞突涌水及泉流量衰减是隧洞施工过程中最棘手的问题之一。锰矿沟岩溶水系统岩溶管道化程度高,岩溶裂隙与岩溶管道2种含水介质差异显著。采用MODFLOW-CFPv2双重介质数值模型对锰矿沟岩溶水系统展开数值模拟研究,精细刻画岩溶管道与引水隧洞,进而掌握隧洞施工对地下水流场影响以及泉流量变化的规律。结果表明:(1)MODFLOW-CFPv2模型能够刻画岩溶地区复杂的地质结构,较好地模拟研究区地下水位的动态特征和岩溶泉流量响应特征。(2)在强排工况下隧洞单位长度最大涌水量为164 m^(3)/(d·m),单位长度稳定涌水量为69 m^(3)/(d·m),锰矿沟岩溶泉流量也出现显著下降的趋势,在模拟期内平均泉流量从天然条件下1578 L/s下降至1098 L/s,总体减少了30.4%;峰值泉流量从2133 L/s下降至1375 L/s,减少了35.5%,强排工况施工会对隧洞工程施工和地下水环境造成显著影响;限排工况下隧洞单位长度最大涌水量为39 m^(3)/(d·m),单位长度稳定涌水量为24 m^(3)/(d·m),隧洞单位长度涌水量显著降低,锰矿沟岩溶泉流量的下降趋势也得到了一定程度的改善,模拟期内平均泉流量降低至1284 L/s,减少了18.6%,峰值泉流量降低至1617 L/s,减少了22.1%。采用的MODFLOW-CFPv2双重介质模型具有较精确刻画岩溶区管道、溶洞、裂隙共存的高度非均质岩溶水系统的能力,能够定量评价香炉山隧洞施工对锰矿沟岩溶水系统地下水流场及泉流量的影响,为香炉山隧洞工程的突涌水灾害防治提供参考依据,也为岩溶地区复杂地质条件下地下水研究提供借鉴经验。 展开更多
关键词 双重介质 数值模拟 引水隧洞 泉流量 MODflow-CFPv2模型 岩溶隧道 突涌水 云南锰矿沟岩溶水系统
下载PDF
基于Flowmaster的发动机滑油供油系统流量压力换热特性建模与仿真
13
作者 冷子昊 程荣辉 +2 位作者 郁丽 苏壮 李国权 《机械工程师》 2024年第2期112-116,共5页
为了分析滑油从滑油泵组流经燃滑油散热器、喷嘴至轴承腔内的流动换热特性,基于Flowmaster流体系统仿真平台,以发动机滑油供油系统为研究对象,通过各支点喷嘴模型建立及仿真计算,验证喷嘴设计符合性。根据燃滑油散热器结构特点,计算流... 为了分析滑油从滑油泵组流经燃滑油散热器、喷嘴至轴承腔内的流动换热特性,基于Flowmaster流体系统仿真平台,以发动机滑油供油系统为研究对象,通过各支点喷嘴模型建立及仿真计算,验证喷嘴设计符合性。根据燃滑油散热器结构特点,计算流阻和换热特性,建立仿真计算模型,验证散热器流阻特性及换热性能;建立滑油供油系统模型,仿真计算轴承腔、附件机匣、转接齿轮箱等处供油流量、供油压力及供油温度,分析评估系统流量压力换热特性,支撑滑油系统正向设计。 展开更多
关键词 滑油供油系统 燃滑油散热器 流量 压力 换热 flowmaster
下载PDF
Flow behavior and microstructure of ZK60 magnesium alloy compressed at high strain rate 被引量:5
14
作者 吴远志 严红革 +3 位作者 朱素琴 陈吉华 刘安民 刘先兰 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2014年第4期930-938,共9页
Flow behavior and microstructure of a homogenized ZK60 magnesium alloy were investigated during compression in the temperature range of 250-400 ℃ and the strain rate range of 0.1-50 s^-1. The results showed that dyna... Flow behavior and microstructure of a homogenized ZK60 magnesium alloy were investigated during compression in the temperature range of 250-400 ℃ and the strain rate range of 0.1-50 s^-1. The results showed that dynamic recrystallization (DRX) developed mainly at grain boundaries at lower strain rate (0.1-1 s^-1), while in the case of higher strain rate (10-50 s^-1), DRX occurred extensively both at twins and grain boundaries at all temperature range, especially at temperature lower than 350 ℃, which resulted in a more homogeneous microstructure than that under other deformation conditions. The DRX extent determines the hot workability of the workpiece, therefore, hot deformation at the strain rate of 10-50 s^-1 and in the temperature range of 250-350 ℃ was desirable for ZK60 alloy. Twin induced DRX during high strain rate compression included three steps. Firstly, twins with high dislocation subdivided the initial grain, then dislocation arrays subdivided the twins into subgrains, and after that DRX took place with a further increase of strain. 展开更多
关键词 ZK60 magnesium alloy high strain rate compression flow behavior MICROSTRUCTURE twin induced DRX
下载PDF
A study of hydrate plug formation in a subsea natural gas pipeline using a novel high-pressure flow loop 被引量:12
15
作者 Li Wenqing Gong Jing +3 位作者 Lü Xiaofang Zhao Jiankui Feng Yaorong Yu Da 《Petroleum Science》 SCIE CAS CSCD 2013年第1期97-105,共9页
The natural gas pipeline from Platform QKI8-1 in the southwest of Bohai Bay to the onshore processing facility is a subsea wet gas pipeline exposed to high pressure and low temperature for a long distance. Blockages i... The natural gas pipeline from Platform QKI8-1 in the southwest of Bohai Bay to the onshore processing facility is a subsea wet gas pipeline exposed to high pressure and low temperature for a long distance. Blockages in the pipeline occur occasionally. To maintain the natural gas flow in the pipeline, we proposed a method for analyzing blockages and ascribed them to the hydrate formation and agglomeration. A new high-pressure flow loop was developed to investigate hydrate plug formation and hydrate particle size, using a mixture of diesel oil, water, and natural gas as experimental fluids. The influences of pressure and initial flow rate were also studied. Experimental results indicated that when the flow rate was below 850 kg/h, gas hydrates would form and then plug the pipeline, even at a low water content (10%) of a water/oil emulsion. Furthermore, some practical suggestions were made for daily management of the subsea pipeline. 展开更多
关键词 Natural gas hydrate BLOCKAGE flow assurance high-pressure loop water cut flow rate
下载PDF
Impact of stretching-segment on saturated flow rate of signalized intersection using cellular automation 被引量:4
16
作者 李岩 陈宽民 过秀成 《Journal of Central South University》 SCIE EI CAS 2013年第10期2887-2896,共10页
In order to analyze the impact of stretching-segment on the saturated flow rate of signalized intersection approach, an improved cellular automation model was proposed to estimate its saturated flow rate. The NaSch mo... In order to analyze the impact of stretching-segment on the saturated flow rate of signalized intersection approach, an improved cellular automation model was proposed to estimate its saturated flow rate. The NaSch model was improved by adding different slow probabilities, turning deceleration rules and modified lane changing rules. The relationship between the saturated flow rate of stretching-segments and adjacent lanes was tested in numerical simulation. The length of stretching-segment, cycle length and green time were selected as impact factors of the cellular automation model. The simulation result indicates that the geometrics design of stretching-segment and the traffic signal timing scenario have major effects on the saturated flow rate of the intersection approach. The saturated flow rate will continually increase with increasing stretching-segment length until it reaches a threshold. After reaching the threshold, the stretching-segment can be treated as a separate lane. The green time is approximately linearly related to the threshold length of the stretching-segment. An optimum cycle length exists when the length of the stretching-segment is not long enough, and it is approximately linearly related to the length of stretching-segment. 展开更多
关键词 traffic engineering saturated flow rate stretching-segment cellular automation model
下载PDF
Influences of gas flow rates on melting of particles of HVOF sprayed CoCrW coating and coating properties 被引量:3
17
作者 YANGZhongyuan 《Rare Metals》 SCIE EI CAS CSCD 2004年第1期53-58,共6页
This paper discussed influences of flow rates of O_2, C_3H_8, and compressedair on the melting degree of particles during HVOF (high velocity oxy-fuel) sprayed CoCrW coating.The O_2 flow rate has the maximal effect on... This paper discussed influences of flow rates of O_2, C_3H_8, and compressedair on the melting degree of particles during HVOF (high velocity oxy-fuel) sprayed CoCrW coating.The O_2 flow rate has the maximal effect on the melting of particles, the C_3H_8 flow rate has thesecond, and the compressed air flow rate has the minimal effect. The bond strength of the HVOFsprayed CoCrW coating is over 54 MPa. The porosity ratio of the HVOF sprayed CoCrW coating afteroptimization of gas flow rates is less than 2%. The average microhardness of the coating is up toHV_(0.1) 545. The oxidation amount per unit area of the HVOF sprayed CoCrW coating increases withthe holding time increasing at 800℃. In the same way, the oxidation amount of the coating increasesas the temperature increases. Particularly, the oxidation of the coating drastically increases over850℃. 展开更多
关键词 CoCrW flow rate HVOF bond strength OXIDATION ORTHOGONALITY
下载PDF
Influence of temperature and strain rate on flow stress behavior of twin-roll cast, rolled and heat-treated AZ31 magnesium alloys 被引量:11
18
作者 F.BERGE L.KRüGER +1 位作者 H.OUAZIZ C.ULLRICH 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2015年第1期1-13,共13页
The effects of temperature and strain rate on the flow stress behavior of twin-roll cast, rolled and heat-treated AZ31 magnesium alloys were investigated under uniaxial tension. At high temperatures, dynamic recovery,... The effects of temperature and strain rate on the flow stress behavior of twin-roll cast, rolled and heat-treated AZ31 magnesium alloys were investigated under uniaxial tension. At high temperatures, dynamic recovery, continuous dynamic recrystallization, grain boundary sliding and the activation of additional slip systems lead to an improvement of the ductility of the alloys. The elongation to failure is nearly independent of the strain rate between 473 and 523 K at 10-2 s-1 and 10-1 s-1, which is related to the strain rate dependence of the critical resolved shear stress(CRSS) for nonbasal slip. Despite the high temperature, twins are even observed at 573 K and 10-3 s-1 because they have a low CRSS. 展开更多
关键词 AZ31 magnesium alloy twin-roll casting strain rate TEMPERATURE dynamic recrystallization flow stress
下载PDF
Investigation of oil-air two-phase mass flow rate measurement using Venturi and void fraction sensor 被引量:5
19
作者 张宏建 岳伟挺 黄志尧 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2005年第6期601-606,共6页
Oil-air two-phase flow measurement was investigated with a Venturi and void fraction meters in this work. This paper proposes a new flow rate measurement correlation in which the effect of the velocity ratio between g... Oil-air two-phase flow measurement was investigated with a Venturi and void fraction meters in this work. This paper proposes a new flow rate measurement correlation in which the effect of the velocity ratio between gas and liquid was considered. With the pressure drop across the Venturi and the void fraction that was measured by electrical capacitance tomography apparatus, both mixture flow rate and oil flow rate could be obtained by the correlation. Experiments included bubble-, slug-, wave and annular flow with the void fraction ranging from 15% to 83%, the oil flow rate ranging from 0.97 kg/s to 1.78 kg/s, the gas flow rate ranging up to 0.018 kg/s and quality ranging nearly up to 2.0%. The root-mean-square errors of mixture mass flow rate and that of oil mass flow rate were less than 5%. Furthermore, coefficients of the correlation were modified based on flow regimes, with the results showing reduced root-mean-square errors. 展开更多
关键词 Oil-air two-phase flow rate VENTURI Void fraction flow regime Electrical capacitance tomography
下载PDF
Relationship between Formation Water Rate,Equivalent Penetration Rate and Volume Flow Rate of Air in Air Drilling 被引量:2
20
作者 Wang Kexiong Zhang Laibin Jiang Hongwei 《Petroleum Science》 SCIE CAS CSCD 2007年第4期62-65,共4页
Formation water invasion is the most troublesome problem associated with air drilling. However, it is not economical to apply mist drilling when only a small amount of water flows into wellbore from formation during a... Formation water invasion is the most troublesome problem associated with air drilling. However, it is not economical to apply mist drilling when only a small amount of water flows into wellbore from formation during air drilling. Formation water could be circulated out of the wellbore through increasing the gas injection rate. In this paper, the Angel model was modified by introducing Nikurade friction factor for the flow in coarse open holes and translating formation water rate into equivalent penetration rate. Thus the distribution of annular pressure and the relationship between minimum air injection rate and formation water rate were obtained. Real data verification indicated that the modified model is more accurate than the Angel model and can provide useful information for air drilling. 展开更多
关键词 Air drilling Angel model modified model formation water rate minimum volume flow rate equivalent penetration rate
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部